Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Diabetes Res Clin Pract ; 93(1): e49-52, 2011 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-21529979

RESUMEN

This brief report discusses the introduction of routine Glutamic Acid Decarboxylase Antibody (GADA) testing in primary care for newly diagnosed diabetes. GADA testing is well used and the majority of people found to be positive are initiated on insulin rapidly and progress to require a basal bolus regime.


Asunto(s)
Autoanticuerpos/análisis , Diabetes Mellitus Tipo 1/diagnóstico , Diabetes Mellitus Tipo 1/enzimología , Glutamato Descarboxilasa/inmunología , Adulto , Anciano , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Femenino , Humanos , Insulina/uso terapéutico , Masculino , Persona de Mediana Edad
2.
Int J Lab Hematol ; 29(4): 279-83, 2007 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-17617078

RESUMEN

Accurate, reliable laboratory reference ranges are essential for effective clinical evaluation and monitoring. We present robust reference ranges established for haematology, coagulation and haematinic parameters using the Sysmex XE 2100, CA 1500 and Beckman-Coulter Access analysers. Blood samples were taken from 250 healthy laboratory personnel and routine haematology, coagulation and haematinic parameter analysis performed. Our data represent findings from an extensive study to establish reference ranges in healthy adults.


Asunto(s)
Hematología/normas , Adulto , Recuento de Células Sanguíneas/normas , Factores de Coagulación Sanguínea/normas , Ferritinas/sangre , Ácido Fólico/sangre , Humanos , Valores de Referencia , Vitamina B 12/sangre
3.
Clin Lab Haematol ; 22(5): 279-85, 2000 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-11122269

RESUMEN

This study describes a method of measuring the INR on native whole blood capillary samples using Innovin recombinant thromboplastin. Modification of the reagent was necessary to compensate for the nonoptimal level of calcium in the sample/reagent mixture. Ninety-five percent of results obtained by the capillary blood method were no more than 0.42 INR higher or 0.38 INR lower than the venous blood method. The effect of changes in haematocrit was minimal. Significant differences in results were found between the Innovin and Thrombotest capillary blood methods. Provided the reagent was properly stored, there was no reagent drift and satisfactory results were obtained on samples supplied by UKNEQAS (coagulation) from previous trials. The method described is a convenient, simple and accurate method of measuring the INR using native capillary whole blood and Innovin recombinant thromboplastin.


Asunto(s)
Pruebas de Coagulación Sanguínea/métodos , Relación Normalizada Internacional , Pruebas de Coagulación Sanguínea/normas , Recolección de Muestras de Sangre/métodos , Capilares , Hematócrito , Humanos , Tiempo de Protrombina , Estándares de Referencia , Reproducibilidad de los Resultados
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...