Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
J Thorac Cardiovasc Surg ; 122(3): 592-9, 2001 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-11547315

RESUMEN

OBJECTIVES: Residual stress is the stress (force per unit area) that remains when all external loads (eg, left ventricular chamber and pericardial pressures) are removed. It has been suggested that ventricular volume reduction surgery can reconstitute the residual stress-strain state of the left ventricle. To determine the extent to which residual stress is involved, we used a mathematical (finite element) model to simulate the effect of volume reduction operations on left ventricular stroke volume/end-diastolic pressure (Starling) relationships, as well as on regional distributions of stress in the local muscle fiber direction (fiber stress). METHODS: The nonlinear stress-strain relationship for the diastolic myocardium was anisotropic with respect to the local muscle fiber direction. An elastance model for active fiber stress was incorporated in an axisymmetric geometric model of the dilated, poorly contractile left ventricular wall. RESULTS: When residual stress is implemented in the model simulation of volume reduction operations, the additional decrease in stroke volume at fixed left ventricular end-diastolic pressure is small (10% volume reduction: 2.0% at 1 mm Hg and 2.0% at 20 mm Hg; 20% volume reduction: 2.2% at 1 mm Hg and 3.1% at 20 mm Hg). Furthermore, there is little change in the mean fiber stress throughout the left ventricular wall (10% volume reduction: +1.0% at end-diastole and -0.3% at end-systole; 20% volume reduction: +2.1% at end-diastole and -1.0% at end-systole). CONCLUSIONS: These results suggest that residual stress produced by volume reduction operations has little effect on left ventricular function and the mean fiber stresses at end-diastole and end-systole.


Asunto(s)
Cardiomiopatía Dilatada/fisiopatología , Cardiomiopatía Dilatada/cirugía , Análisis de Elementos Finitos , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/cirugía , Ventrículos Cardíacos/cirugía , Modelos Cardiovasculares , Dinámicas no Lineales , Volumen Sistólico , Función Ventricular Izquierda , Presión Ventricular , Anisotropía , Diástole , Elasticidad , Humanos , Estrés Mecánico , Sístole , Resultado del Tratamiento
2.
Ann Thorac Surg ; 70(4): 1301-7, 2000 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-11081889

RESUMEN

BACKGROUND: This study tested the hypothesis that induction and reperfusion with warm substrate-enriched (IRWSE) blood cardioplegia improves postoperative left ventricular (LV) function in patients undergoing elective coronary bypass surgery (CABG). METHODS: After giving informed consent, 67 patients scheduled for CABG surgery were randomized to either IRWSE + cold blood (CB) or CB alone. IRWSE cardioplegia consisted of 37 degrees C substrate-enriched (glutamate, aspartate, hyperkalemic) anterograde and retrograde blood cardioplegic solution followed by non-substrate-enriched cardioplegic solution given at 4 degrees C to 8 degrees C. LV function was measured with ventriculograms, volume conductance catheters, echocardiography, and multiple gated (image) acquisition. RESULTS: The end-systolic pressure-volume relationship was improved postbypass in the IRWSE + CB group (CB, 1.5 +/- 0.74 mm Hg/mL vs IRWSE + CB, 2.1 +/- 1.2 mm Hg/mL; p = 0.042). The postoperative ejection fraction (EF%) was better preserved in the CB group (CB, 65 +/- 11.53% vs IRWSE + CB, 58.62 +/- 11.75%; p < 0.04). CONCLUSIONS: Our results demonstrate a transient improvement in LV systolic function in the immediate postbypass period in CABG patients in the IRWSE + CB group. The intraoperative benefits of the IRWSE + CB technique did not persist in the postoperative period.


Asunto(s)
Soluciones Cardiopléjicas , Puente de Arteria Coronaria , Hipotermia Inducida , Reperfusión Miocárdica/métodos , Función Ventricular Izquierda/fisiología , Adulto , Anciano , Sangre , Femenino , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/fisiopatología , Método Simple Ciego , Volumen Sistólico/fisiología , Sístole/fisiología , Temperatura
3.
J Thorac Cardiovasc Surg ; 119(6): 1194-204, 2000 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-10838539

RESUMEN

OBJECTIVE: Myocardial infarct expansion and subsequent left ventricular remodeling are associated with increased incidence of congestive failure and mortality. Collagen is known to denature and contract when heated above 65 degrees C. We therefore tested the hypothesis that radio frequency heating of myocardial infarct tissue with application of a restraining patch causes a sustained reduction in myocardial infarct area and left ventricular volume. METHODS: Thirteen male Dorset sheep underwent surgical coronary artery ligation. At least 14 weeks later, animals were randomized to either radio frequency infarct heating (95 degrees C) with application of a restraining patch or a sham operation. Before treatment, after treatment, and 10 weeks later, left ventricular volume was measured with transdiaphragmatic echocardiography and myocardial infarct area was measured with an array of sonomicrometry crystals. RESULTS: Radio frequency infarct heating causes an acute decrease of 34% (-215 +/- 82 mm(2); P =.0002) in infarct area at end-diastole that is maintained at 10 weeks (-144 +/- 79 mm(2); P =.0002). Radio frequency infarct heating causes a downward trend in end-diastolic left ventricular volume measured by echocardiography of 20% (-15.7 +/- 6.3 mL; P = no significant difference) and end-systolic left ventricular volume of 32% (-17.1 +/- 9.8 mL; P =.09), which are significantly decreased at 10 weeks (-13.6 +/- 22.3 mL; P =.007 and -15.3 +/- 21.9 mL; P =.008, respectively). Radio frequency infarct heating causes an acute improvement in systolic function (P <.001), a sustained increase in left ventricular ejection fraction (+0.11%; P =.06), and preserved stroke volume. CONCLUSION: Radio frequency heating of chronic left ventricular myocardial infarct causes a sustained reduction in infarct area and left ventricular volume. This technique may beneficially reverse infarct expansion and left ventricular remodeling after myocardial infarction.


Asunto(s)
Diatermia , Ventrículos Cardíacos/patología , Infarto del Miocardio/patología , Infarto del Miocardio/terapia , Animales , Enfermedad Crónica , Masculino , Ovinos
4.
Anesth Analg ; 90(4): 840-6, 2000 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-10735785

RESUMEN

UNLABELLED: We tested the hypothesis that L-arginine (the substrate for nitric oxide production)-combined with amrinone, milrinone (Type III phosphodiesterase [PDE] inhibitors), zaprinast, or sildenafil (Type V PDE inhibitors)-would vasodilate synergistically. Internal mammary artery segments were excised from anesthetized swine, divided into rings, and suspended in a tissue bath at 37 degrees C. Force of contraction was measured during dose-response testing of combinations of L-arginine and amrinone, milrinone, zaprinast, or sildenafil. Amrinone and milrinone were additive to L-arginine. N(G)-methyl-L-arginine (L-NMA) inhibited the effects of milrinone but not amrinone. The effective concentration of amrinone eliciting 50% relaxation (EC(50)) was 3.8E-05M (n = 6) when given alone and 4. 4E-05M (n = 6) with L-NMA. Milrinone had EC(50) = 6.0E-06M alone (n = 6) and 2.8E-05M (n = 6) with L-NMA. Zaprinast (EC(50) = 6.5E-05M, n = 6) and sildenafil (EC(30) = 1.8E-05M, n = 6) were synergistic with L-arginine. L-NMA blocked their effects, increasing the EC(50) for zaprinast to 9.9E-03M and the EC(30) for sildenafil to 6.1E+02M. In conclusion, L-arginine is additive to the vasodilation of the type III PDE inhibitors, amrinone and milrinone, but synergistic with the type V PDE inhibitors, zaprinast and sildenafil. IMPLICATIONS: Amrinone and milrinone, Type III cAMP-dependent phosphodiesterase inhibitors, are additive to L-arginine-dependent vasodilation. Zaprinast and sildenafil, Type V cGMP-dependent phosphodiesterase inhibitors, are synergistic with L-arginine.


Asunto(s)
Arginina/farmacología , Arterias Mamarias/efectos de los fármacos , Inhibidores de Fosfodiesterasa/farmacología , Vasodilatación/efectos de los fármacos , Animales , GMP Cíclico/fisiología , Relación Dosis-Respuesta a Droga , Sinergismo Farmacológico , Arterias Mamarias/fisiología , Porcinos , omega-N-Metilarginina/farmacología
5.
ASAIO J ; 46(1): 111-6, 2000.
Artículo en Inglés | MEDLINE | ID: mdl-10667728

RESUMEN

Partial ventriculectomy (PV) has been proposed by Batista and colleagues to improve cardiac function in patients with dilated cardiomyopathy (DCM); however, results have been mixed. We tested the hypothesis that preoperative diastolic function affects the stroke volume/end-diastolic pressure (Starling) relationship after PV. A previously described finite element simulation of DCM and PV was used. Diastole and end systole were represented by separate elastic finite element models with different unloaded shapes and nonlinear material properties. Left ventricular (LV) end-systolic elastance (E(ES)), diastolic compliance (DC), and Starling relationships were calculated. DC was varied by changing Ogden material property alpha(i) from 12 (compliant) to 20 (stiff). PV was simulated at 20% LV mass reduction. The slope of the Starling relationship increased from 1.82 to 1.21 as alpha(i) increased from 12 to 20. Partial ventriculectomy increased the Starling relationship in each case from 1.34 to 1.01 respectively. However, the net result in each case is a decrement in the Starling relationship with resection, and the smallest decrement was associated with the highest diastolic stiffness (alpha(i) = 20). Partial ventriculectomy depressed the Starling relationship for all values of diastolic compliance. It is expected that patients with a higher diastolic stiffness should do better.


Asunto(s)
Cardiomiopatía Dilatada/cirugía , Diástole , Ventrículos Cardíacos/cirugía , Función Ventricular , Cardiomiopatía Dilatada/fisiopatología , Humanos
6.
Anesthesiology ; 92(1): 178-89, 2000 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-10638915

RESUMEN

BACKGROUND: The endotracheal cardiac output monitor (ECOM) is a new device that uses an endotracheal tube with multiple electrodes to measure cardiac output (CO). It measures the changes in electrical impedance caused by pulsatile blood flow in the aorta. The system was tested for safety and efficacy in 10 swine. METHODS: Swine (60-80 kg) were chronically instrumented with a transit time flow probe on the ascending aorta and vascular occluders on the vena cava and pulmonary artery. After a minimum recovery of 4 days, the animals were anesthetized and intubated with an ECOM endotracheal tube. CO measurements from the ECOM system were compared to transit time flow probe measurements using linear regression and Bland-Altman analysis. Three different inotropic states were studied: (1) baseline; (2) increased (dobutamine); and (3) decreased (esmolol). CO was changed at each inotropic state by impeding left ventricular filling with the vena cava or pulmonary artery occluders. CO values between 0 and 15 l/min were studied. Pigs were studied for 24 h consecutively. RESULTS: There was no deterioration of the impedance signal with time and no tracheal injury from the ECOM electrodes. There is a linear relationship between the ECOM and transit time flow probe CO between 0 and 15 l/min (slope = 0.94; intercept = 0.15 l/min; R2= 0.77). The mean difference between the two measures (bias) is 0.15 l/min and the SD is 1.34 l/min. The limits of agreement are -2.53 to 2.82 l/min. CONCLUSION: Endotracheal CO monitor is a promising technology that needs further evaluation in clinical trials.


Asunto(s)
Antagonistas Adrenérgicos beta/farmacología , Gasto Cardíaco/efectos de los fármacos , Cardiotónicos/farmacología , Dobutamina/farmacología , Intubación Intratraqueal/instrumentación , Monitoreo Fisiológico/instrumentación , Propanolaminas/farmacología , Algoritmos , Animales , Impedancia Eléctrica , Electrodos , Diseño de Equipo , Femenino , Intubación Intratraqueal/efectos adversos , Porcinos , Tráquea/lesiones , Tráquea/patología
7.
J Thorac Cardiovasc Surg ; 119(1): 115-24, 2000 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-10612769

RESUMEN

OBJECTIVE: The success of left ventricular aneurysm plication depends on how the procedure affects both end-systolic elastance and diastolic compliance and how those changes affect ventricular function (stroke work/end-diastolic volume [PRSW] and stroke volume/end-diastolic pressure [Starling] relationships). METHODS: Five male Dorsett sheep were surgically instrumented with coronary artery snares, an inferior vena caval occluder, and an ascending aortic ultrasonic flow probe. One week later an anteroapical myocardial infarction was produced by tightening the coronary snares. Ten weeks after myocardial infarction, the left ventricular aneurysm was plicated. Absolute left ventricular volume was measured by long-axis transdiaphragmatic echocardiography, and relative changes in left ventricular volume were measured with a conductance catheter. End-systolic elastance, diastolic compliance, PRSW, and Starling relationships were measured immediately before myocardial infarction, 10 weeks after myocardial infarction (immediately before plication), and immediately after and 6 weeks after aneurysm plication. RESULTS: After plication, end-diastolic and end-systolic left ventricular volumes return to preinfarction values. The slopes of end-systolic elastance, diastolic compliance, and PRSW decrease 10 weeks after myocardial infarction, increase with aneurysm plication, and then decrease 6 weeks after aneurysm plication. The Starling relationship undergoes a downward parallel shift with aneurysm plication. CONCLUSION: Aneurysm plication abruptly decreases left ventricular volume and diastolic compliance, increases end-systolic elastance and PRSW, but decreases the Starling relationship. The net effect on left ventricular function is mixed. Furthermore, left ventricular remodeling 6 weeks after aneurysm plication causes left ventricular volume, end-systolic elastance, diastolic compliance, PRSW, and the Starling relationship to return to preplication values.


Asunto(s)
Aneurisma Cardíaco/fisiopatología , Aneurisma Cardíaco/cirugía , Función Ventricular/fisiología , Animales , Cateterismo Cardíaco , Adaptabilidad , Diástole/fisiología , Modelos Animales de Enfermedad , Ecocardiografía/métodos , Elasticidad , Aneurisma Cardíaco/diagnóstico por imagen , Modelos Lineales , Masculino , Infarto del Miocardio/patología , Ovinos , Volumen Sistólico/fisiología , Sístole/fisiología , Presión Ventricular/fisiología , Remodelación Ventricular/fisiología
8.
Anesthesiology ; 90(6): 1577-86, 1999 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-10360855

RESUMEN

BACKGROUND: Nitric oxide-dependent factors (serotonin, activated platelets, acetylcholine) cause vasodilation in normal coronary arteries but vasoconstrict atherosclerotic vessels. This experiment tested the hypothesis that intravenous systemic infusions of L-arginine, a precursor for nitric oxide production, dilate the coronary vascular bed of patients undergoing coronary artery bypass graft surgery. METHODS: Twenty patients scheduled for coronary artery bypass graft surgery surgery were studied in a prospective, blinded, randomized clinical trial. Saphenous vein graft blood flow was measured with a transit time flow probe, and coronary vascular resistance was calculated. After weaning from bypass, patients were given a venous infusion (placebo or 10% arginine hydrochloride [30 g]) over 15 min. Arterial blood samples for the determination of L-arginine and L-citrulline levels were drawn before, 10 min after starting infusion, and 10 min after end of infusion. RESULTS: The placebo group experienced an increase in mean arterial pressure and coronary vascular resistance and a decrease in graft blood flow. Patients in the L-arginine group maintained their baseline values. Mean arterial pressure (L-arginine, 88+/-17 to 92+/-13 mmHg vs. placebo, 80+/-12 to 92+/-9 mmHg, P = 0.021), coronary vascular resistance (L-arginine, 97,000+/-60,000 to 99,600+/-51,000 dynes x s x cm(-5) vs. placebo, 81,000+/-69,000 to 117,000+/-64,000 dynes x s x cm(-5), P = 0.05), and graft blood flow (L-arginine, 55+/-25 to 50+/-19 ml/min vs. placebo, 60+/-34 to 46+/-18, P = 0.05) remained more stable in the L-arginine-treated patients. CONCLUSIONS: Systemic L-arginine infusion reduced postbypass coronary vasoconstriction. There were no adverse events associated with the drug infusion.


Asunto(s)
Arginina/farmacología , Puente de Arteria Coronaria , Vasos Coronarios/efectos de los fármacos , Vasodilatación/efectos de los fármacos , Anciano , Arginina/sangre , Citrulina/sangre , Vasos Coronarios/fisiología , Humanos , Persona de Mediana Edad , Óxido Nítrico/fisiología , Estudios Prospectivos
9.
J Thorac Cardiovasc Surg ; 116(4): 566-77, 1998 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-9766584

RESUMEN

OBJECTIVES: Ventricular volume reduction surgery has been proposed by Batista to improve cardiac function in patients with dilated cardiomyopathy. However, limited clinical data exist to determine the efficacy of this operation. A finite element simulation is therefore used to determine the effect of volume reduction surgery on left ventricular end-systolic elastance, diastolic compliance, stroke work/end-diastolic volume (preload recruitable stroke work), and stroke work/end-diastolic pressure (Starling) relationships. METHODS: End-diastole and end-systole were represented by elastic finite element models with different unloaded shapes and nonlinear material properties. End-systolic elastance, diastolic compliance, preload recruitable stroke work, and Starling relationships, as well as energy expenditure per gram of unresected myocardium, were calculated. Two different types of volume reduction surgery (apical and lateral) were simulated at 10% and 20% left ventricular mass reduction. RESULTS: Ventricular volume reduction surgery causes diastolic compliance to shift further to the left on the pressure-volume diagram than end-systolic elastance. Volume reduction surgery increases the slope of the preload recruitable stroke work relationship (dilated cardiomyopathy 0.006 J/mL; 20% lateral volume reduction surgery 0.009 J/mL) but decreases the slope of the Starling relationship (dilated cardiomyopathy 0.028 J/mm Hg; 20% lateral volume reduction 0.023 J/mm Hg). For a given amount of resection, lateral volume reduction has a greater effect than apical volume reduction. Ten-percent and 20% lateral volume reduction reduces energy expenditure by 7% and 17%, respectively. CONCLUSION: Ventricular volume reduction surgery shifts end-systolic elastance and diastolic compliance to the left on the pressure-volume diagram. The net effect on ventricular function is mixed. Volume reduction surgery increases the slope of preload recruitable stroke work, but increased diastolic compliance causes a small decrease in the Starling relationship (3 mm Hg difference between dilated cardiomyopathy and volume reduction surgery at stroke work = 0.5 J).


Asunto(s)
Cardiomiopatía Dilatada/cirugía , Simulación por Computador , Ventrículos Cardíacos/cirugía , Modelos Teóricos , Contracción Miocárdica/fisiología , Disfunción Ventricular Izquierda/cirugía , Adulto , Volumen Cardíaco/fisiología , Cardiomiopatía Dilatada/fisiopatología , Gráficos por Computador , Diástole/fisiología , Metabolismo Energético/fisiología , Ventrículos Cardíacos/fisiopatología , Humanos , Complicaciones Posoperatorias/fisiopatología , Programas Informáticos , Volumen Sistólico/fisiología , Sístole/fisiología , Disfunción Ventricular Izquierda/fisiopatología , Función Ventricular Izquierda/fisiología
10.
Am J Physiol ; 257(4 Pt 2): H1228-34, 1989 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-2801982

RESUMEN

The direct effects of vasopressin on the resistance and capacitance properties of the pulmonary and systemic vasculature were studied in nine aneural dogs on systemic and pulmonary bypass. The systemic and pulmonary pressure-flow, the systemic and pulmonary arterial pressure-volume, and the systemic and pulmonary venous pressure-volume relationships were determined for five levels of infused vasopressin. Vasopressin levels of approximately 10, 30, 150, 300, and 500 pg/ml were achieved by intravenous infusions. Samples of venous blood were drawn before and after each set of pressure-flow and pressure-volume relationships for the determination of vasopressin level by radioimmunoassay. A linear relationship was found between vasopressin level and systemic vascular resistance. Systemic vascular resistance increased 0.072 +/- 0.011 mmHg.kg.min.ml-1 for a change in vasopressin level of 100 pg/ml. Vasopressin did not affect pulmonary vascular resistance or any vascular compliance. High doses of infused arginine vasopressin were necessary to elicit substantial vasoconstriction.


Asunto(s)
Arginina Vasopresina/farmacología , Circulación Sanguínea/efectos de los fármacos , Músculo Liso Vascular/fisiología , Arteria Pulmonar/fisiología , Circulación Pulmonar/efectos de los fármacos , Resistencia Vascular/efectos de los fármacos , Animales , Presión Sanguínea/efectos de los fármacos , Perros , Músculo Liso Vascular/efectos de los fármacos , Arteria Pulmonar/efectos de los fármacos , Valores de Referencia
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA