Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 135
Filtrar
2.
J Org Chem ; 89(14): 10327-10332, 2024 Jul 19.
Artículo en Inglés | MEDLINE | ID: mdl-38961650

RESUMEN

Nitrones are quite useful intermediates and have been broadly applied in organic synthesis, drug discovery, and photochemistry research. Many functional nitrones have been successfully prepared using various strategies. In this work, an efficient method for synthesizing novel quinolinoneylnitrone and coumarinylnitrone derivatives was developed. Preliminary mechanistic research suggests that this protocol included a cascade hydroamination and aza-MBH-type reaction.

3.
Ann Lab Med ; 2024 Jul 02.
Artículo en Inglés | MEDLINE | ID: mdl-38953114

RESUMEN

Background: The accurate measurement of α-fetoprotein (AFP) is critical for clinical diagnosis. However, different AFP immunoassays may yield different results. Appropriate AFP reference materials (RMs) were selected and assigned accurate values for applications with external quality assessment (EQA) programs to standardize AFP measurements. Methods: Forty individual clinical samples and six different concentrations of candidate RMs (Can-RMs, L1-L6) were prepared by the Beijing Center for Clinical Laboratories. The Can-RMs were assigned target values by performing five immunoassays, using WHO International Standard 72/225 as a calibrator, and sent to 45 clinical laboratories in Beijing for AFP measurements. The commutability of all RMs was assessed based on CLSI and the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) approaches. Analytical performance was assessed for compliance based on accuracy (total error, TE), trueness (bias), and precision (CV). Results: The Can-RMs were commutable for all immunoassays using the CLSI approach and for 6 of 10 assay combinations using the IFCC approach. RMs diluted in WHO RM 72/225 were commutable among all assays with the CLSI approach, except for serum matrix (Autolumo vs. Roche analyzer) and diluted water matrix (Abbott vs. Roche/Mindray analyzer), whereas some inconclusive and non-commutable results were found using the IFCC approach. The average pass rates based on the TE, bias, and CV were 91%, 81%, and 95%, respectively. Conclusions: The commutability of the RMs differed between both evaluation approaches. The Can-RMs exhibited good commutability with the CLSI approach, suggesting their suitability for use with that approach as commutable EQA materials with assigned values and for monitoring the performance of AFP measurements.

5.
ACS Omega ; 9(23): 24236-24251, 2024 Jun 11.
Artículo en Inglés | MEDLINE | ID: mdl-38882125

RESUMEN

There are several sets of coal-bearing source rocks within the Lower and Middle Jurassic (J1-2) in the southern Junggar sub-basin. To obtain a comprehensive understanding of hydrocarbon generation and the amount of potentially generated natural gas, Rock-Eval analysis was conducted on source rock samples to assess their kerogen types and quality. At the same time, maceral observation and gold-tube pyrolysis were carried out to quantify the different maceral groups and to predict the gas potential, respectively. The Rock-Eval data indicate that the investigated samples are dominated by type III kerogen and occasionally supplemented with type II kerogen. Among the six immature source rocks selected for gold-tube pyrolysis, they are vitrinite-dominated except for a dark mudstone from the Badaowan Formation that is liptinite-dominated. A positive relationship between the maximum gas yield and the liptinite content was observed. However, the accuracy of liptinite content estimation largely depends on the experience level of the organic petrographer. The optimized C1-5 generation activation energies for the six source rocks cover a broad range between 50 and 74 kcal/mol. A relatively larger proportion of higher activation energies (74 kcal/mol) for the carbonaceous mudstone from the Badaowan Formation and also for the dark mudstone from the Sangonghe Formation implies late gas generation. Under geological conditions, the modeled gas conversion from J1-2 source rocks in the central part of the southern Junggar sub-basin ranged from 52 to 74%, indicating good exploration potential. Notably, the computed gas generation from the dark mudstone from the Sangonghe Formation resembles that from the Xishanyao Formation. Gas generation from the Sangonghe Formation should be considered in the future.

7.
Heliyon ; 10(9): e30218, 2024 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-38707421

RESUMEN

Background: Epidural nonopioid adjuvants also reduce local anesthetic use. We aimed to test the hypothesis that, compared with the present standard fentanyl, the hourly consumption of local anesthetic was at least as good when dexmedetomidine or esketamine was combined with local anesthetic for patient-controlled epidural analgesia (PCEA). Methods: A total of 120 laboring nulliparous subjects requiring labor analgesia were recruited for the final statistical analysis. Subjects were randomized to receive 0.075 % ropivacaine added with one of three equivalent adjuvants: 0.4 µg/mL fentanyl, 0.4 µg/mL dexmedetomidine, or 1.0 mg/mL esketamine. The primary outcome was hourly ropivacaine consumption. Compared with the fentanyl group, a 20 % difference in hourly local anesthetic consumption between the dexmedetomidine and esketamine groups was considered a clinical difference (non-inferiority margin). Results: The hourly ropivacaine consumption of the fentanyl group was 12.4 (95 % confidence interval CI 11.2 to 13.6) ml/h, so the prespecified non-inferiority limit was 2.5 ml/h. The hourly ropivacaine consumption of the fentanyl group was not inferior to that of the dexmedetomidine group (12.4 ml/h vs. 11.9 ml/h, risk difference, 0.5; 95 % confidence interval CI, -1.0 to 2.0, meeting criteria for non-inferiority). However, the hourly ropivacaine consumption of the esketamine group was 14.3 ml/h, and that of the fentanyl group was 12.4 ml/h (risk difference, 1.9, 95 % CI, 0.2 to 3.6), failing to confirm non-inferiority with a non-inferiority margin of 20 %. The incidence of pruritus was highest in the fentanyl group, whereas the occurrence of mild dizziness was highest in the esketamine group. Conclusions: In setting of the conditions of this study, epidural dexmedetomidine was non-inferior compared with epidural fentanyl in combination with ropivacaine for PCEA during labor. Meanwhile, we failed to establish the non-inferiority of epidural esketamine compared with epidural fentanyl in combination with ropivacaine for labor analgesia.

8.
Clin Chem Lab Med ; 2024 May 16.
Artículo en Inglés | MEDLINE | ID: mdl-38748888

RESUMEN

OBJECTIVES: Patient-based real-time quality control (PBRTQC) is an alternative tool for laboratories that has gained increasing attention. Despite the progress made by using various algorithms, the problems of data volume imbalance between in-control and out-of-control results, as well as the issue of variation remain challenges. We propose a novel integrated framework using anomaly detection and graph neural network, combining clinical variables and statistical algorithms, to improve the error detection performance of patient-based quality control. METHODS: The testing results of three representative analytes (sodium, potassium, and calcium) and eight independent variables of patients (test date, time, gender, age, department, patient type, and reference interval limits) were collected. Graph-based anomaly detection network was modeled and used to generate control limits. Proportional and random errors were simulated for performance evaluation. Five mainstream PBRTQC statistical algorithms were chosen for comparison. RESULTS: The framework of a patient-based graph anomaly detection network for real-time quality control (PGADQC) was established and proven feasible for error detection. Compared with classic PBRTQC, the PGADQC showed a more balanced performance for both positive and negative biases. For different analytes, the average number of patient samples until error detection (ANPed) of PGADQC decreased variably, and reductions could reach up to approximately 95 % at a small bias of 0.02 taking calcium as an example. CONCLUSIONS: The PGADQC is an effective framework for patient-based quality control, integrating statistical and artificial intelligence algorithms. It improves error detection in a data-driven fashion and provides a new approach for PBRTQC from the data science perspective.

9.
Front Pharmacol ; 15: 1368222, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38595925

RESUMEN

Background: The aim of our study was to administer adequate local anesthetic in programmed intermittent epidural bolus (PIEB) to avoid breakthrough pain and decrease the use of manual and PCEA boluses. We, therefore, conducted this study to determine the effective PIEB interval time between boluses of ropivacaine 0.0625% with dexmedetomidine 0.4 µg/ml at a fixed volume of 10 mL in 90% of subjects (EI90), without the use of patient-controlled epidural analgesia (PCEA). Methods: A total of 80 subjects were included in the final statistical analysis from 23 August 2022 to 22 November 2022. The subjects were randomly assigned to one of four different PIEB time intervals: 40, 50, 60, and 70 min (groups 40, 50, 60, and 70), respectively. The primary outcome was the effective epidural labor analgesia, defined as no use of PCEA bolus or a manual bolus until the end of the first stage of labor or within 6 hours after loading dose administration. The PIEB EI90 (95% CI) between boluses of ropivacaine 0.0625% with dexmedetomidine 0.4 µg/ml at a fixed volume of 10 mL was estimated using probit regression. Results: The effective PIEB interval time between boluses of ropivacaine 0.0625% with dexmedetomidine 0.4 µg/ml at a fixed volume of 10 mL in 90% of subjects without the use of PCEA was 45.4 (35.5-50.5) minutes using probit regression. No statistical differences were found in the proportion of subjects with Bromage score > 0, hypotension, pruritus, nausea, and vomiting between groups. However, the highest sensory block (pinprick) in the 40-min group was significantly higher than that in the other groups. Conclusion: The estimated value for EI90 for PIEB between boluses of ropivacaine 0.0625% with dexmedetomidine 0.4 µg/ml at a fixed volume of 10 mL using probit regression was 45.4 (35.5-50.5) minutes. Furthermore, future studies are warranted to be established to determine the optimal parameters for different regimens in clinical practice.

10.
Chem Biodivers ; 21(5): e202400283, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38485665

RESUMEN

Fifteen bibenyls and four fluorenones, including five new bibenzyl-phenylpropane hybrids, were isolated from the aerial part of Dendrobium nobile Lindl. Their structures were determined by spectroscopic methods. Bioassay on the LPS-induced proliferations of mouse splenic B lymphocytes, and Con A-induced T lymphocytes showed that compounds 1, 2, and 14 showed excellent immunosuppressive activities with IC50 values of 1.23, 1.01, and 3.87 µM, respectively, while compounds 3-4, 7, 10, 13, and 15 exhibited moderate immunosuppressive activities with IC50 values ranging from 6.89 to 14.2 µM.


Asunto(s)
Bibencilos , Proliferación Celular , Dendrobium , Inmunosupresores , Dendrobium/química , Animales , Ratones , Inmunosupresores/farmacología , Inmunosupresores/química , Inmunosupresores/aislamiento & purificación , Bibencilos/química , Bibencilos/farmacología , Bibencilos/aislamiento & purificación , Proliferación Celular/efectos de los fármacos , Linfocitos T/efectos de los fármacos , Linfocitos B/efectos de los fármacos , Estructura Molecular , Relación Estructura-Actividad , Lipopolisacáridos/farmacología , Lipopolisacáridos/antagonistas & inhibidores , Relación Dosis-Respuesta a Droga , Concanavalina A/antagonistas & inhibidores , Concanavalina A/farmacología
11.
J Colloid Interface Sci ; 664: 893-901, 2024 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-38493654

RESUMEN

Electrocatalysts are useful in lowering the energy barrier in oxygen reduction reaction (ORR). In this study, a catalyst with neighboring Fe single-atom and cluster is created by adsorbing a bimetallic Fe complex onto N-doped carbon and then pyrolyzing it. The resulting catalyst has good performance and a half-wave potential of 0.89 V. When used in Zn-air batteries, the voltage drops by only 8.13 % after 145 h of cycling. Theoretical studies show that electrons transfer from neighboring clusters to single atoms and the catalyst has a lower d-band center. These reduce intermediate desorption energy, hence improving ORR performance. This work demonstrates the capacity to adjust the catalytic properties through the interaction of diverse metal structures, which helps to design more efficient catalysts.

12.
Heliyon ; 10(3): e25158, 2024 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-38322892

RESUMEN

Objective: This study aimed to assess the current status of carcinoembryonic antigen (CEA) detection. We evaluated the correlation, consistency, and comparability of CEA results among six automated immunoassays, and combined with the results of CEA trueness verification of the Beijing Center for Clinical Laboratories (BCCL) for further analysis. Methods: Abbott Architect i2000, Beckman DxI800, Roche Cobas E601, Diasorin Liaison XL, Maccura IS1200, and Autolumo A2000 were used to detect 40 individual serum CEA samples. Taking the optimal analytical quality specifications calculated from data on biological variation as the evaluation criterion. Passing-Bablok regression and Bland-Altman analysis were performed between each assay and all-assays median values to evaluate the correlation and relative difference. The concordance correlation coefficient (CCC) was used for consistency analysis. Additionally, the trueness verification program used samples at three concentration levels to assess the bias, coefficient of variation (CV), and total error (TE) between the average measured values and the target value. Results: The Spearman's rank correlation coefficient (rs) was ≥0.996 and the CCC ranged between 0.9448 and 0.9990 for each assay vs. all-assays median. Considering the all-assays median value of each sample as a reference, there were proportional and systematic differences according to the Passing-bablok regression analysis. The relative difference of the four assays (Abbott Architect i2000, Autolumo A2000, Diasorin Liaison XL, and Maccura IS1200) met the optimal analytical quality specifications. On the other hand, Beckman DxI800 (13.2 %) and Roche Cobas E601 (-9.0 %) were only able to fulfill the desirable analytical quality specifications. The average pass rates for bias, CV, and TE of the trueness verification program were 80 %, 98 %, and 96 %, respectively. Conclusions: The six automated immunoassays vs. all-assays median have a good correlation in CEA detection. However, there is a lack of comparability of CEA results. Further improvements are needed in harmonization among CEA detections.

13.
BMC Cardiovasc Disord ; 24(1): 43, 2024 Jan 13.
Artículo en Inglés | MEDLINE | ID: mdl-38218809

RESUMEN

BACKGROUND: Cardiac masses can encompass a variety of conditions, such as tumors, thrombi, vegetations, calcific lesions, and other rare diseases. Treatment and management of these types of cardiac masses differ considerably. Thus, accurately distinguishing among thrombi, benign tumors, and malignant tumors in the heart is of great importance. Contrast echocardiography (CE) has emerged as a promising technology. Although published guidelines suggest that CE can enhance image quality and assist in differentiating between benign and malignant lesions, most studies on CE diagnosis of cardiac masses are limited to case reports or retrospective/small-sample-sized prospective cohorts. This study aims to evaluate the diagnostic accuracy of CE in patients with suspected cardiac masses and address the insufficient evidence for differential diagnosis using CE. METHODS: Between April 2018 and July 2022, a prospective multicenter study was conducted, which included 145 consecutive patients suspected to have cardiac masses based on transthoracic echocardiography. All patients underwent CE examinations. The echocardiographic diagnosis relied on qualitative factors such as echogenicity, boundary, morphology of the base, mass perfusion, pericardial effusion, and motility as well as quantitative factors such as the area of the masses and the peak intensity ratio of the masses to adjacent myocardium (A1/A2). RESULTS: The final confirmed diagnoses were as follows: 2 patients had no cardiac mass, 4 patients had pseudomass, 43 patients had thrombus, 66 patients had benign tumors, and 30 patients had malignant tumors. The receiver operating characteristic (ROC) analysis indicated that an optimal A1/A2 cutoff value of 0.499 distinguished a cardiac tumor from a thrombus, with AUC, sensitivity, specificity, PPV, and NPV of 0.977, 97.9%, 90.7%, 95.9%, and 95.1%, respectively. The optimal A1/A2 cutoff value of 1.583 distinguished a cardiac tumor from a thrombus, with AUC, sensitivity, specificity, PPV, and NPV of 0.950, 93.3%, 93.9%, 87.5%, and 96.9%, respectively. CONCLUSIONS: Combined with qualitative and quantitative analyses, CE has the potential to accurately differentiate among different types of cardiac masses.


Asunto(s)
Neoplasias Cardíacas , Trombosis , Humanos , Estudios Retrospectivos , Estudios Prospectivos , Medios de Contraste , Ecocardiografía/métodos , Neoplasias Cardíacas/diagnóstico por imagen , Diagnóstico Diferencial , Sensibilidad y Especificidad
14.
Clin Chem Lab Med ; 62(4): 635-645, 2024 Mar 25.
Artículo en Inglés | MEDLINE | ID: mdl-37982680

RESUMEN

OBJECTIVES: Patient-based real-time quality control (PBRTQC), a laboratory tool for monitoring the performance of the testing process, has gained increasing attention in recent years. It has been questioned for its generalizability among analytes, instruments, laboratories, and hospitals in real-world settings. Our purpose was to build a machine learning, nonlinear regression-adjusted, patient-based real-time quality control (mNL-PBRTQC) with wide application. METHODS: Using computer simulation, artificial biases were added to patient population data of 10 measurands. An mNL-PBRTQC was created using eight hospital laboratory databases as a training set and validated by three other hospitals' independent patient datasets. Three different Patient-based models were compared on these datasets, the IFCC PBRTQC model, linear regression-adjusted real-time quality control (L-RARTQC), and the mNL-PBRTQC model. RESULTS: Our study showed that in the three independent test data sets, mNL-PBRTQC outperformed the IFCC PBRTQC and L-RARTQC for all measurands and all biases. Using platelets as an example, it was found that for 20 % bias, both positive and negative, the uncertainty of error detection for mNL-PBRTQC was smallest at the median and maximum values. CONCLUSIONS: mNL-PBRTQC is a robust machine learning framework, allowing accurate error detection, especially for analytes that demonstrate instability and for detecting small biases.


Asunto(s)
Aprendizaje Automático , Humanos , Simulación por Computador , Control de Calidad
15.
J Inflamm Res ; 16: 5779-5789, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38076333

RESUMEN

Purpose: Outcomes after autologous stem cell transplantation (ASCT) are quite variable and difficult to predict. Second-generation flow, second-generation sequencing, and other tests are invasive and expensive for patients. In this study, we aimed to analyze laboratory data before and after transplantation to look for laboratory indicators that could predict disease progression in patients with newly diagnosed multiple myeloma (NDMM) patients underwent ASCT. Patients and Methods: Standard complete blood count (CBC) parameters, clinical biochemical, and immunological indicators on day -5 and day 90 after ASCT were obtained. Receiver-operating characteristic (ROC) curve was used to determine the cutoff values, we evaluated the predictive abilities of laboratory parameters for progression-free survival (PFS). Univariate and multivariate analyses were performed to evaluate the prognostic significance of variables associated with the PFS of 166 NDMM who underwent ASCT. Results: At day-5, a low absolute monocyte count (AMC, p=0.001), systemic inflammation response index<1.56 (SIRI, P=0.03), serum calcium (p=0.02), and albumin (p=0.006) can predict for superior PFS. At Day +90, a high absolute neutrophil count (ANC, p = 0.008) and lymphocyte-to-monocyte ratio (LMR, p = 0.02), a low neutrophil-to-lymphocyte ratio (NLR, p =0.02) and SIRI<0.41 (p=0.02) predicted for superior PFS. Conclusion: There are inflammation-related indicators derived from peripheral blood cell count (WBCC) - ANC, NLR, SIRI, and LMR - which can serve as potential biomarkers for predicting PFS of NDMM patients underwent ASCT.

16.
Microbiol Spectr ; : e0185823, 2023 Sep 27.
Artículo en Inglés | MEDLINE | ID: mdl-37754782

RESUMEN

Public health threats posed by emerging respiratory infections are a significant concern, particularly in children and infants. Traditional culture-based detection methods are time-consuming and typically require 1-3 days. Herein, we developed and evaluated a 23-plex common respiratory pathogen mass spectrometry assay that enables the simultaneous detection of 18 common respiratory pathogens in children. This assay combines matrix-assisted laser desorption/ionization time of flight mass spectrometry with multiplex reverse transcription-PCR and targets 11 bacterial and 7 viral pathogens (including 10 subtypes), and two internal controls. The detection limit of the common respiratory pathogen mass spectrometry assay was as low as 1 copy/µL, with no cross-reactivity with other organisms. We assessed the clinical performance of the common respiratory pathogen mass spectrometry assay using respiratory samples from 450 children. The total 450 clinical specimens underwent analysis via matrix-assisted laser desorption/ionization time of flight mass spectrometry, and the outcomes were juxtaposed with those derived from real-time reverse-transcriptase PCR conducted concurrently. The concordance between these methods was 96.0%, and the multiple infection identification rate was 7.1%. This innovative approach enables the simultaneous analysis of numerous outcomes from a solitary examination across 192 specimens within a timeframe of approximately 7 hours, with a dramatically reduced sample use and cost. In summary, the common respiratory pathogen mass spectrometry assay is a sensitive, accurate, and cost-effective method for detecting common respiratory pathogens in children and has the potential to revolutionize the diagnosis of respiratory tract infections. IMPORTANCE This study aimed to present and evaluate a novel co-detection method that enables the simultaneous identification of 11 bacterial and 7 viral pathogens in about 7 hours using matrix-assisted laser desorption/ionization time of flight mass spectrometry. Our approach utilizes a combination of multiplex reverse transcription-PCR and matrix-assisted laser desorption/ionization time of flight mass spectrometry, which overcomes the limitations of conventional assays, which include a long assessment time, technical difficulty, and high costs. As a screening method for common respiratory pathogens in children, common respiratory pathogen mass spectrometry assay has the potential to revolutionize the diagnosis of respiratory tract infections by providing an accurate etiological diagnosis. The common respiratory pathogen mass spectrometry assay is expected to be a critical tool for the diagnosis of respiratory infections in children, offering a more efficient, cost-effective, and accurate approach for the detection of common respiratory pathogens.

17.
J Clin Lab Anal ; 37(13-14): e24955, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37571860

RESUMEN

BACKGROUND: This study aimed to assess the commutability of frozen pooled human serum (PHS), high concentration of Immunoglobulin M (IgM) pure diluted materials (HPDM), commercialized pure materials (CPM), and dilutions of ERM-DA470k/IFCC in IgM detection using the CLSI and IFCC approaches, to support standardization or harmonization of IgM measurement. METHODS: Twenty-four serum samples, relevant reference materials (PHS, HPDM, CPM), and different ERM-DA470k/IFCC dilutions were analyzed in triplicate using six routine methods. The commutability of the relevant reference materials was carried out following CLSI EP30-A and IFCC bias analysis. RESULTS: According to the CLSI approach, low, medium, and high concentrations of PHS, HPDM, and CPM were commutable on 10, 13, 15, 13, and 8 of 15 assay combinations, respectively. Using the IFCC approach, low, medium, and high concentrations of PHS, HPDM, and CPM were commutable on 10, 11, 9, 15, and 10 of 15 assay combinations, respectively. The ERM-DA470k/IFCC dilutions with D-PBS and RPMI-1640 Medium were commutable on 13 of 15 assay combinations according to CLSI and were commutable on all 15 assay combinations using IFCC approach. CONCLUSIONS: High concentration of PHS were commutable on all six detection systems using the CLSI approach. Low and medium concentration of PHS showed unsatisfied commutability. HPDM, not CPM have good commutability, has the potential to become reference materials. ERM-DA470k/IFCC diluted with different medium showed different commutability.


Asunto(s)
Suero , Humanos , Estándares de Referencia , Pruebas de Coagulación Sanguínea , Inmunoglobulina M , Técnicas de Dilución del Indicador
18.
Food Nutr Res ; 672023.
Artículo en Inglés | MEDLINE | ID: mdl-37533448

RESUMEN

Background: Recent studies from targeted and untargeted metabolomics have consistently revealed that diet-related metabolites, including carnitine (C0), several species of acylcarnitines (AcyCNs), amino acids, ceramides, and lysophosphatidylcholines (LPCs) may serve as potential multiple myeloma (MM) biomarkers. However, most of these approaches had some intrinsic limitations, namely low reproducibility and compromising the accuracy of the results. Objective: This study developed and validated a precise, efficient, and reliable liquid chromatography tandem mass spectrometric (LC-MS/MS) method for measuring these 28 metabolic risk factors in human serum. Design: This method employed isopropanol to extract the metabolites from serum, gradient elution on a hydrophilic interaction liquid chromatographic column (HILIC) for chromatographic separation, and multiple reaction monitor (MRM) mode with positive electrospray ionization (ESI) for mass spectrometric detection. Results: The correlation coefficients of linear response for this method were more than 0.9984. Analytical recoveries ranged from 91.3 to 106.3%, averaging 99.5%. The intra-run and total coefficients of variation were 1.1-5.9% and 2.0-9.6%, respectively. We have simultaneously determined the serological levels of C0, several subclasses of AcyCNs, amino acids, ceramides, and LPCs within 15 min for the first time. Conclusion: The established LC-MS/MS method was accurate, sensitive, efficient, and could be valuable in providing insights into the association between diet patterns and MM disease and added value in further clinical research.

19.
J Clin Lab Anal ; 37(11-12): e24936, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-37395487

RESUMEN

BACKGROUND: In this study, we explored the commutability of reference materials (RMs) for carcinoembryonic antigen (CEA), selected the appropriate diluent matrix of the first International Reference Preparation (IRP) 73/601 of the World Health Organization (WHO 73/601) for CEA, and improved the comparability of CEA measurement results among different assay systems. METHODS: Forty serum samples were divided into five aliquots. WHO 73/601 was diluted into nine concentrations using five diluents with different components, and the candidate RMs for CEA at five concentrations (C1-C5) were prepared by the Beijing Clinical Laboratory Center (BCCL). The samples were analyzed via five automated CEA immunoassays. RESULTS: Carcinoembryonic antigen candidate RMs were commutable among all immunoassays based on the CLSI approach and among 7 of 10 assay combinations based on the IFCC approach. WHO 73/601 diluted in phosphate-buffered saline (PBS) was commutable among all assays based on the CLSI approach and among 5 of 10 pairwise comparisons based on the IFCC approach with correction of bias at diluted concentrations, except for the lowest concentration, which had the smallest variation among systems. The median percentage biases among assays were decreased after calibration. CONCLUSION: The BCCL candidate RMs (C2-C5) for CEA were commutable among all immunoassays. WHO 73/601 RMs diluted in a PBS buffer matrix were selected as common calibrators for five immunoassays, which reduced bias, thereby effectively improving the harmonization of CEA detection; therefore, they could be used to assign values to CEA candidate RMs developed by BCCL. Our findings promote the harmonization of CEA detection in immunoassays.


Asunto(s)
Antígeno Carcinoembrionario , Servicios de Laboratorio Clínico , Humanos , Inmunoensayo , Laboratorios , Laboratorios Clínicos , Estándares de Referencia
20.
Front Plant Sci ; 14: 1225295, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37469776

RESUMEN

The leaf maximum rate of carboxylation (Vcmax) is a key parameter of plant photosynthetic capacity. The accurate estimation of Vcmax is crucial for correctly predicting the carbon flux in the terrestrial carbon cycle. Vcmax is correlated with plant traits including leaf nitrogen (Narea) and leaf photosynthetic pigments. Proxies for leaf chlorophyll (Chlarea) and carotenoid contents (Cararea) need to be explored in different ecosystems. In this study, we evaluated the relationship between leaf maximum rate of carboxylation (scaled to 25°C; Vcmax25) and both leaf Narea and photosynthetic pigments (Chlarea and Cararea) in winter wheat in a farmland ecosystem. Our results showed that Vcmax25 followed the same trends as leaf Chlarea. However, leaf Narea showed smaller dynamic changes before the flowering stage, and there were smaller seasonal variations in leaf Cararea. The correlation between leaf Vcmax25 and leaf Chlarea was the strongest, followed by leaf Cararea and leaf Narea (R2 = 0.69, R2 = 0.47 and R2 = 0.36, respectively). The random forest regression analysis also showed that leaf Chlarea and leaf Cararea were more important than leaf Narea for Vcmax25. The correlation between leaf Vcmax25 and Narea can be weaker since nitrogen allocation is dynamic. The estimation accuracy of the Vcmax25 model based on Narea, Chlarea, and Cararea (R2 = 0.75) was only 0.05 higher than that of the Vcmax25 model based on Chlarea and Cararea (R2 = 0.70). However, the estimation accuracy of the Vcmax25 model based on Chlarea and Cararea (R2 = 0.70) was 0.34 higher than that of the Vcmax25 model based on Narea (R2 = 0.36). These results highlight that leaf photosynthetic pigments can be a predictor for estimating Vcmax25, expanding a new way to estimate spatially continuous Vcmax25 on a regional scale, and to improve model simulation accuracy.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA