Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Mater Sci Eng C Mater Biol Appl ; 63: 301-7, 2016 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-27040223

RESUMEN

The objective of this study is to analyze the light power distribution along the tip end of the light guide of three LED-LCUs (Light Curing Units) and to evaluate its effect on the mechanical properties of a polymer based dental composite. Firstly, the light power distribution over the whole area of LED-LCU light guide surface was analyzed by three methods: visual projection observation, spectral measurement and optical spectral analysis (OSA). The light power distribution and the total irradiance were different for the three LEDs used, but the wavelength was within the camphorquinone absorption spectrum. The use of a blank sheet was quite on hand to make a qualitative analysis of a beam, and it is costless. Secondly, specimens of a hybrid composite with approximately 8mm diameter and 2mm thickness were produced and polymerized by 20s exposition time to each LED-LCU. Thirdly, the elastic modulus (E) and hardness (HV) were measured throughout the irradiated area by instrumented micro-indentation test (IIT), allowing to correlate localized power and mechanical properties. Both E and HV showed to be very sensitive to local power and wavelength dependent, but they followed the beam power profile. It was also shown that the mechanical properties could be directly correlated to the curing process. Very steep differences in mechanical properties over very short distances may impair the material performance, since residual stresses can easily be built over it.


Asunto(s)
Resinas Compuestas/química , Módulo de Elasticidad , Dureza , Luz , Polimerizacion
2.
Mater Sci Eng C Mater Biol Appl ; 47: 70-6, 2015 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-25492174

RESUMEN

This study proposes an alternative methodology for evaluating polymerization shrinkage of dental composites using an advanced video extensometer (AVE) system. This equipment measures the displacement between two points drawn on a tooth's wall without requiring physical contact with the tooth. By doing so, the polymerization process was monitored by the cusp deflection. This technique was used in human and bovine teeth, where the cavities were prepared under controlled conditions so that the volume of the composite used was the same in both types of teeth. After the cavity preparation, the specimens were acid etched, washed and dried, and then the adhesive was applied and polymerized. The composite was then inserted into the cavity. Polymerization was performed with two different light polymerizing units (LD Max and Optilight Max - Gnatus do Brasil), and the displacement curve of the tooth cusp was recorded for a period of 400 s. After a statistical analysis, it was concluded that the technique was capable of evaluating shrinkage by the deflection from the cusps and that the human and bovine teeth do not react in a similar manner towards the polymerization shrinkage of composites.


Asunto(s)
Materiales Dentales , Polimerizacion , Animales , Bovinos , Humanos , Ensayo de Materiales , Microscopía Electrónica de Rastreo , Óptica y Fotónica
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA