Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Clin Anesth ; 27(8): 638-45, 2015 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-26359017

RESUMEN

STUDY OBJECTIVE: Dilution is often required to obtain appropriate concentrations of intrathecal morphine for analgesia. We compared techniques of diluting by measuring the quantity of morphine actually obtained in the final solution. DESIGN: This is an experimental study by 3 experienced anesthesiologists. SETTING: The setting is at a university teaching hospital. PATIENTS: There are no patients. INTERVENTIONS: There are no interventions. MEASUREMENTS: Five techniques for obtaining 100 µg from 10 mg/mL were compared: technique 1 (T1) = extraction up to 0.1 graduation on a 1-mL syringe, followed by simple dilution (SD). Technique 2 (T2) = As for T1 but syringe was shaken to mix solution. Technique 3 (T3): SD with 10-mL syringe. Technique 4 (T4): Double dilution with 10-mL syringe. Technique 5 (T5): Extraction up to the 0.1 graduation of a 1-mL syringe, then SD, then shake solution by hand. Three tests using high-performance liquid chromatography with ultraviolet were performed on each syringe prepared 3 consecutive times, namely, at the first (beginning, B), fifth (middle, M) and last (end, E) milliliter or 0.1 mL (depending on syringe type). MAIN RESULTS: Average overall concentrations were 208 ±19, 199 ±24, 120 ±13, 136 ±9, and 119 ±16 µg/0.1 mL, T1-T5, respectively. By Kruskal-Wallis test, we classified the techniques according to the magnitude of the difference between the observed concentration of morphine and the desired (theoretical) concentration of 100 µg/0.1 mL. In ascending order, techniques ranked as follows: T5 (smallest difference), T3, T4, T2, and T1 (greatest difference) (P = .0001). CONCLUSIONS: There is significant variability in the concentration of morphine actually contained in final solutions after dilution. Morphine presented in different premixed concentrations increases the risk of error. We advocate technique 5 as described above, whereas technique 1 should be prohibited.


Asunto(s)
Analgésicos Opioides/administración & dosificación , Anestesia Raquidea/métodos , Composición de Medicamentos/métodos , Morfina/administración & dosificación , Analgésicos Opioides/química , Anestesiología/métodos , Cromatografía Líquida de Alta Presión/métodos , Hospitales Universitarios , Humanos , Inyecciones Espinales , Morfina/química , Jeringas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...