Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
J Endovasc Ther ; 14(5): 650-60, 2007 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-17924730

RESUMEN

PURPOSE: To investigate the morphological effects of suprarenal fixation of aortic stent-grafts on the renal artery ostia (RaO) by analysis of suprarenal stent wire distribution and vascular calcification across the RaO using virtual intravascular endoscopy (VIE). METHODS: Fourteen consecutive patients (11 men; mean age 75 years) from a single institution were studied following endovascular aortic aneurysm repair (EVAR) using the Zenith endograft system from September 1999 to March 2002. Imaging assessment included computed tomographic (CT) measurement of renal artery intraluminal ostial diameter and quantification and analysis of uncovered stent struts across the RaO and radiological determination of RaO calcification. Morphological changes following EVAR at 3 time points (before and within 1 week after stent-grafting, and at the most recent follow-up) were compared for each patient to determine whether suprarenal stent struts or RaO calcification affected intraluminal ostial diameter. Renal function was assessed by temporal measurements of serum creatinine concentration and creatinine clearance. RESULTS: The renal ostium was distorted to variable degrees in all cases at a mean follow-up of 41+/-6.6 months. An increase in ostial diameter was identified in most patients if the right RaO was calcified when comparing the 1-week postoperative and most recent follow-up CT images (p<0.05). There was no direct relationship between the number of stent struts crossing the RaO and the morphological/dimensional changes (p>0.05). Renal function was not significantly affected. CONCLUSION: Patients undergoing suprarenal fixation of aortic stent-grafts experienced morphological changes of the RaO to a variable extent at midterm follow-up. Although the presence of stent struts did not significantly affect dimensional changes, we observed that calcification at the renal artery ostium may influence the development of atherosclerotic effects as a direct relationship between the calcification and ostial diameter. Future studies utilizing VIE to determine the long-term safety of this technique in these particular patients requires investigation.


Asunto(s)
Aneurisma de la Aorta Abdominal/cirugía , Implantación de Prótesis Vascular/métodos , Prótesis Vascular , Endoscopía/métodos , Arteria Renal/diagnóstico por imagen , Stents , Tomografía Computarizada por Rayos X , Interfaz Usuario-Computador , Anciano , Anciano de 80 o más Años , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/instrumentación , Calcinosis/diagnóstico por imagen , Femenino , Estudios de Seguimiento , Migración de Cuerpo Extraño/diagnóstico por imagen , Migración de Cuerpo Extraño/etiología , Migración de Cuerpo Extraño/prevención & control , Humanos , Masculino , Persona de Mediana Edad , Interpretación de Imagen Radiográfica Asistida por Computador , Arteria Renal/cirugía , Proyectos de Investigación , Factores de Tiempo , Resultado del Tratamiento
2.
J Vasc Surg ; 45(4): 694-700, 2007 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-17398377

RESUMEN

OBJECTIVE: The effect of suprarenal stent fixation during endovascular aortic aneurysm repair (EVAR) on renal function remains unclear. A unique validated three-dimensional intraluminal imaging technique was used to analyze the effect of suprarenal stent position relative to renal artery orifices. Also analyzed was its medium-term to long-term effects on renal function. METHODS: The study cohort comprised 29 of 34 consecutive patients who underwent EVAR with the Zenith endograft system from September 1999 to March 2002 at a single institution. The precise locations of the uncovered suprarenal stent struts were assessed by a virtual endoscopic imaging technique. Anatomic and quantitative categorization of patients was made according to the configuration of uncovered stent struts across the renal artery ostia (RAO). The anatomic subgroups were defined as struts located centrally or peripherally across both RAO. The quantitative subgroups were defined as RAO crossed by multiple struts, a solitary strut, or no struts. The subgroups were compared for their renal function, as assessed by temporal measurements of serum creatinine concentration and creatinine clearance, and renal parenchymal perfusion defects, as assessed using contrast-enhanced computed tomography (CT). RESULTS: Mean follow-up was 52.7 months. Separate subgroup analysis for both anatomic and quantitative configurations did not demonstrate any significant difference in renal function between the different strut permutations (P > .05). Follow-up imaging confirmed one case of renal infarction secondary to an occluded accessory renal artery, although this patient had normal serum creatinine levels. CONCLUSION: RAO coverage by suprarenal uncovered stents does not appear to have a significant effect on renal function as evaluated by creatinine measurements in patients with normal preoperative renal function.


Asunto(s)
Angioscopía/métodos , Aneurisma de la Aorta Abdominal/cirugía , Implantación de Prótesis Vascular/efectos adversos , Enfermedades Renales/etiología , Enfermedades Renales/fisiopatología , Arteria Renal/diagnóstico por imagen , Stents , Anciano , Anciano de 80 o más Años , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/fisiopatología , Implantación de Prótesis Vascular/instrumentación , Estudios de Cohortes , Creatinina/sangre , Femenino , Estudios de Seguimiento , Humanos , Procesamiento de Imagen Asistido por Computador , Imagenología Tridimensional , Enfermedades Renales/sangre , Enfermedades Renales/diagnóstico por imagen , Pruebas de Función Renal , Masculino , Estudios Prospectivos , Diseño de Prótesis , Obstrucción de la Arteria Renal/diagnóstico por imagen , Obstrucción de la Arteria Renal/etiología , Obstrucción de la Arteria Renal/fisiopatología , Circulación Renal , Reproducibilidad de los Resultados , Factores de Tiempo , Tomografía Computarizada Espiral , Resultado del Tratamiento
3.
Comput Med Imaging Graph ; 30(3): 139-45, 2006 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-16631349

RESUMEN

Diabetic retinopathy (DR) is a leading cause of blindness in people of working age in developed countries. DR is characterized by lesions of the retinal microvasculature. This paper describes a technique for visualizing the changes which occur in retinal pathology over a 1 year interval. Pairs of retinal images of the same eye were acuired 12 months apart within a DR screening programme. The images were normalized, registered and subtracted to generate a contrast-enhanced difference image displaying changes in retinal appearance. The normalization factor and registration error were quantified for 104 pairs of retinal images.


Asunto(s)
Retinopatía Diabética/patología , Diagnóstico por Imagen/métodos , Tamizaje Masivo , Adulto , Anciano , Algoritmos , Retinopatía Diabética/diagnóstico , Humanos , Persona de Mediana Edad , Estudios Retrospectivos
4.
J Endovasc Ther ; 11(1): 13-25, 2004 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-14748633

RESUMEN

PURPOSE: To investigate the diagnostic value of postprocessing techniques for 3-dimensional (3D) computed tomography (CT), with emphasis on CT virtual intravascular endoscopy (VIE), in patients with abdominal aortic aneurysms (AAA) treated with suprarenal stent-grafts. METHODS: The preprocedural and postprocedural CT datasets from 47 AAA patients (40 men; mean age 75 years, range 61-87) undergoing aortic stent-grafting with suprarenal fixation were examined. The CT datasets were processed to create various 3D reconstructions: shaded surface display (SSD), maximum intensity projection (MIP), and VIE. Three independent radiologists assessed various diagnostic parameters for each 3D reconstruction method and compared them to axial CT images. RESULTS: Scores for VIE reconstructions were inferior to axial CT images in the visualization of normal arterial branches, measurement of the aneurysm diameter and neck length, as well as assessment of vessel patency and presence of endoleaks. VIE was rated superior to axial CT and other 3D imaging methods in visualizing the configuration of stent struts relative to the aortic branch ostia and the number of stent wires crossing the ostia in >80% of cases. CONCLUSIONS: VIE was not found to play a role in most preoperative situations compared to axial CT images. However, VIE provided additional postgrafting information on the 3D relationship of the suprarenal stent struts to the aortic branch ostia (in particular the renal and superior mesenteric arteries). VIE findings might aid clinicians in accurately assessing the effect of suprarenal stent-grafting on the renal arteries.


Asunto(s)
Angioscopía/métodos , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Implantación de Prótesis Vascular , Radiografía Intervencional , Tomografía Computarizada Espiral , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador , Imagenología Tridimensional , Masculino , Persona de Mediana Edad , Stents
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA