Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 59
Filtrar
1.
Int J Oral Maxillofac Surg ; 53(7): 600-606, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38494409

RESUMEN

Zygomatic implants (ZI) are a valuable option for supporting an obturator prosthesis after maxillary resection. This study was performed to assess the clinical outcomes of a digitally validated guided technique for ZI placement, followed by immediate prosthetic obturation. The primary objective was to evaluate implant survival, while the secondary objective was to assess patient-reported quality of life post-rehabilitation. Twelve patients treated for head and neck cancer received a total of 36 ZI after ablative surgery. The mean duration of ZI follow-up was 30.1 months. The survival rate of ZI placed in non-irradiated patients was 100%, while it was 85% in irradiated patients. Patient-reported outcomes were evaluated using the Liverpool Oral Rehabilitation Questionnaire (LORQv3) and the University of Washington Quality of Life Questionnaire (UW-QOL v4). Most patients reported satisfactory outcomes in the oral function domain of the LORQv3 (mean score 17.7 ± 4.5; possible range 12-48, with lower scores indicating better outcomes). Regarding the UW-QOL v4, the swallowing and chewing domains had the highest scores (mean 97.5 ± 8.7 and 95.8 ± 14.4, respectively; maximum possible score of 100). In conclusion, this treatment approach improves function and quality of life after maxillary ablative surgery. However, irradiated patients showed a noticeable trend of higher implant failure, and this was influenced by tumour position and size impacting the radiation dose to the zygomatic bone.


Asunto(s)
Neoplasias de Cabeza y Cuello , Calidad de Vida , Cigoma , Humanos , Masculino , Femenino , Persona de Mediana Edad , Cigoma/cirugía , Neoplasias de Cabeza y Cuello/cirugía , Neoplasias de Cabeza y Cuello/radioterapia , Anciano , Resultado del Tratamiento , Estudios de Seguimiento , Encuestas y Cuestionarios , Adulto , Cirugía Asistida por Computador/métodos , Implantes Dentales , Medición de Resultados Informados por el Paciente , Maxilar/cirugía , Prótesis Dental de Soporte Implantado
3.
Oral Oncol ; 140: 106392, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-37084567

RESUMEN

BACKGROUND: Intensity modulated proton beam therapy (IMPT) for head and neck cancer offers dosimetric benefits for the organs at risk when compared to photon-based volumetric modulated arch therapy (VMAT). However, limited data exists about the potential benefits of IMPT for tooth-bearing regions. The aim of this study was to compare the IMPT and VMAT radiation dosimetrics of the tooth-bearing regions in head and neck cancer patients. Also, we aimed to identify prognostic factors for a cumulative radiation dose of ≥40 Gy on the tooth-bearing areas, which is considered the threshold dose for prophylactic dental extractions. METHODS: A total of 121 head and neck cancer patients were included in this retrospective analysis of prospectively collected data. We compared the average Dmean values of IMPT versus VMAT of multiple tooth-bearing regions in the same patients. Multivariate logistic regression analysis was performed for receiving a cumulative radiation dose of ≥40 Gy to the tooth-bearing regions (primary endpoint) in both VMAT and IMPT. RESULTS: A lower Dmean was seen after applying IMPT to the tooth-bearing tumour regions (p < 0.001). Regarding VMAT, oral cavity tumours, T3-T4 tumours, molar regions in the mandible, and regions ipsilateral to the tumour were risk factors for receiving a cumulative radiation dose of ≥40 Gy. CONCLUSIONS: IMPT significantly reduces the radiation dose to the tooth-bearing regions.


Asunto(s)
Neoplasias de Cabeza y Cuello , Terapia de Protones , Radioterapia de Intensidad Modulada , Humanos , Terapia de Protones/efectos adversos , Estudios Retrospectivos , Dosificación Radioterapéutica , Radioterapia de Intensidad Modulada/efectos adversos , Neoplasias de Cabeza y Cuello/radioterapia , Planificación de la Radioterapia Asistida por Computador
4.
Photoacoustics ; 26: 100362, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-35541024

RESUMEN

Oral cancer patients undergo diagnostic surgeries to detect occult lymph node metastases missed by preoperative structural imaging techniques. Reducing these invasive procedures that are associated with considerable morbidity, requires better preoperative detection. Multispectral optoacoustic tomography (MSOT) is a rapidly evolving imaging technique that may improve preoperative detection of (early-stage) lymph node metastases, enabling the identification of molecular changes that often precede structural changes in tumorigenesis. Here, we characterize the optoacoustic properties of cetuximab-800CW, a tumor-specific fluorescent tracer showing several photophysical properties that benefit optoacoustic signal generation. In this first clinical proof-of-concept study, we explore its use as optoacoustic to differentiate between malignant and benign lymph nodes. We characterize the appearance of malignant lymph nodes and show differences in the distribution of intrinsic chromophores compared to benign lymph nodes. In addition, we suggest several approaches to improve the efficiency of follow-up studies.

5.
Sci Rep ; 11(1): 18294, 2021 09 14.
Artículo en Inglés | MEDLINE | ID: mdl-34521962

RESUMEN

The assessment of gaps and steps in acetabular fractures is challenging. Data from various imaging techniques to enable accurate quantification of acetabular fracture displacement are limited. The aim of this study was to assess the accuracy of pelvic radiographs, intraoperative fluoroscopy, and computed tomography (CT) in detecting gaps and step-offs in acetabular fractures. Sixty patients, surgically treated for acetabular fractures, were included. Five observers (5400 measurements) measured the gaps and step-offs on radiographs and CT scans. Intraoperative fluoroscopy images were reassessed for the presence of gaps and/or step-offs. Preoperatively, 25% of the gaps and 40% of the step-offs were undetected on radiographs compared to CT. Postoperatively, 52% of the gaps and 80% of the step-offs were missed on radiographs compared to CT. Radiograph analysis led to a significantly smaller gap and step-off compared to the CT measurements, an underestimation by a factor of two. Approximately 70% of the residual gaps and step-offs was not detected using intraoperative fluoroscopy. Gaps and step-offs that exceed the critical cut-off indicating worse prognosis often remained undetected on radiographs compared to CT scans. Less-experienced observers tend to overestimate gaps and step-offs compared to the more-experienced observers. In acetabular fracture treatment, gaps and step-offs were often undetected and underestimated on radiographs and intraoperative fluoroscopy in comparison with CT scans. This means that CT is superior to radiographs in detecting acetabular fracture displacement, which is clinically relevant for patient counselling regarding treatment decisions and prognosis.


Asunto(s)
Acetábulo/lesiones , Fracturas Óseas/diagnóstico por imagen , Acetábulo/diagnóstico por imagen , Acetábulo/cirugía , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Fluoroscopía , Fijación Interna de Fracturas/métodos , Fracturas Óseas/diagnóstico , Fracturas Óseas/cirugía , Humanos , Cuidados Intraoperatorios , Masculino , Persona de Mediana Edad , Reducción Abierta/métodos , Radiografía , Tomografía Computarizada por Rayos X , Resultado del Tratamiento , Adulto Joven
6.
Int J Implant Dent ; 7(1): 54, 2021 06 14.
Artículo en Inglés | MEDLINE | ID: mdl-34121148

RESUMEN

BACKGROUND: The aim of this study was to introduce a complete 3D workflow for immediate implant retained prosthetic rehabilitation following maxillectomy in cancer surgery. The workflow consists of a 3D virtual surgical planning for tumor resection, zygomatic implant placement, and for an implant-retained prosthetic-obturator to fit the planned outcome situation for immediate loading. MATERIALS AND METHODS: In this study, 3D virtual surgical planning and resection of the maxilla, followed by guided placement of 10 zygomatic implants, using custom cutting and drill/placement-guides, was performed on 5 fresh frozen human cadavers. A preoperatively digitally designed and printed obturator prosthesis was placed and connected to the zygomatic implants. The accuracy of the implant positioning was obtained using 3D deviation analysis by merging the pre- and post-operative CT scan datasets. RESULTS: The preoperatively designed and manufactured obturator prostheses matched accurately the per-operative implant positions. All five obturators could be placed and fixated for immediate loading. The mean prosthetic point deviation on the cadavers was 1.03 ± 0.85 mm; the mean entry point deviation was 1.20 ± 0.62 mm; and the 3D angle deviation was 2.97 ± 1.44°. CONCLUSIONS: It is possible to 3D plan and accurately execute the ablative surgery, placement of zygomatic implants, and immediate placement of an implant-retained obturator prosthesis with 3D virtual surgical planning.The next step is to apply the workflow in the operating room in patients planned for maxillectomy.


Asunto(s)
Cirugía Asistida por Computador , Cigoma , Cadáver , Humanos , Maxilar/diagnóstico por imagen , Prótesis e Implantes , Cigoma/diagnóstico por imagen
7.
J Oral Maxillofac Surg ; 79(9): 1943.e1-1943.e10, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-34033801

RESUMEN

BACKGROUND: Oral and maxillofacial surgery currently relies on virtual surgery planning based on image data (CT, MRI). Three-dimensional (3D) visualizations are typically used to plan and predict the outcome of complex surgical procedures. To translate the virtual surgical plan to the operating room, it is either converted into physical 3D-printed guides or directly translated using real-time navigation systems. PURPOSE: This study aims to improve the translation of the virtual surgery plan to a surgical procedure, such as oncologic or trauma surgery, in terms of accuracy and speed. Here we report an augmented reality visualization technique for image-guided surgery. It describes how surgeons can visualize and interact with the virtual surgery plan and navigation data while in the operating room. The user friendliness and usability is objectified by a formal user study that compared our augmented reality assisted technique to the gold standard setup of a perioperative navigation system (Brainlab). Moreover, accuracy of typical navigation tasks as reaching landmarks and following trajectories is compared. RESULTS: Overall completion time of navigation tasks was 1.71 times faster using augmented reality (P = .034). Accuracy improved significantly using augmented reality (P < .001), for reaching physical landmarks a less strong correlation was found (P = .087). Although the participants were relatively unfamiliar with VR/AR (rated 2.25/5) and gesture-based interaction (rated 2/5), they reported that navigation tasks become easier to perform using augmented reality (difficulty Brainlab rated 3.25/5, HoloLens 2.4/5). CONCLUSION: The proposed workflow can be used in a wide range of image-guided surgery procedures as an addition to existing verified image guidance systems. Results of this user study imply that our technique enables typical navigation tasks to be performed faster and more accurately compared to the current gold standard. In addition, qualitative feedback on our augmented reality assisted technique was more positive compared to the standard setup.?>.


Asunto(s)
Realidad Aumentada , Cirugía Asistida por Computador , Cirugía Bucal , Humanos , Imagenología Tridimensional , Quirófanos , Flujo de Trabajo
8.
Oral Oncol ; 118: 105350, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-34030108

RESUMEN

OBJECTIVES: As a result of the increasing number of diagnostic scans, incidental findings (IFs) are more frequently encountered during oncological work-up in patients with head and neck squamous cell carcinomas (HNSCC). IFs are unintentional discoveries found on diagnostic imaging. Relevant IFs implicate clinical consequences, resulting in delay in oncologic treatment initiation, which is associated with unfavorable outcomes. This study is the first to investigate the incidence and nature of IFs over the years and establish the effect of relevant IFs on delay. MATERIAL AND METHODS: This retrospective study compared two time periods (2010-2011 and 2016-2017), described associations between relevant IFs and delay in carepathway interval (days between first visit and treatment initiation) and assessed the effect of relevant IFs on overall two-year survival. RESULTS: In total, 592 patients were included. At least one IF was found in 61.5% of the patients, most frequently on chest-CT. In 128 patients (21.6%) a relevant IF was identified, resulting for the majority in radiologist recommendations (e.g. additional scanning). Presence of a relevant IF was an independent significant factor associated with delay in treatment initiation. The risk of dying was higher for patients with a relevant IF, although not significant in the multivariable model (HR: 1.46, p = 0.079). CONCLUSION: In diagnostic work-up for HNSCC patients, relevant IFs are frequently encountered. As the frequency of additional imaging rises over the years, the number of IFs increased simultaneously. These relevant IFs yield clinical implications and this study described that relevant IFs result in significant delay in treatment initiation.


Asunto(s)
Neoplasias de Cabeza y Cuello , Hallazgos Incidentales , Carcinoma de Células Escamosas de Cabeza y Cuello , Tiempo de Tratamiento , Neoplasias de Cabeza y Cuello/diagnóstico por imagen , Neoplasias de Cabeza y Cuello/terapia , Humanos , Estudios Retrospectivos , Carcinoma de Células Escamosas de Cabeza y Cuello/diagnóstico por imagen , Carcinoma de Células Escamosas de Cabeza y Cuello/terapia
9.
Int J Oral Maxillofac Surg ; 50(4): 538-545, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-32943309

RESUMEN

Total joint replacement (TJR) with a prosthesis can be indicated for patients with severe temporomandibular joint (TMJ) dysfunction. Surgical accuracy is necessary for correct translation of the preoperatively predicted functional outcome, wear, and biomechanical behaviour of the patient-specific TMJ-TJR prosthesis. This study describes the first clinical applications of the patient-specific TMJ-TJR prosthesis according to the Groningen principles (G-TMJ-TJR), which was developed and validated in a prior human cadaver test study. The aim of this study was to validate the accuracy of placement of the patient-specific G-TMJ-TJR in the clinical setting. It was hypothesized that a virtual surgical plan (VSP) combined with guided placement of the patient-specific G-TMJ-TJR would be performed as predictably and accurately as in the prior cadaver series. All patients who received a VSP-based patient-specific G-TMJ-TJR between December 2017 and March 2020 were included in this study. The accuracy analysis was based on postoperative cone beam computed tomography (CBCT) data. All 11 prostheses could be inserted using routine pre-auricular and retromandibular surgical approaches. Analysis of the VSPs and postoperative CBCTs showed an average three-dimensional deviation of 1.07mm (standard deviation 0.46mm, range 0.33-1.91mm) for all of the fossa and mandibular components. The patient-specific G-TMJ-TJR can be applied predictably and accurately in a clinical setting.


Asunto(s)
Artroplastia de Reemplazo , Prótesis Articulares , Humanos , Mandíbula , Prótesis Mandibular , Diseño de Prótesis , Articulación Temporomandibular/diagnóstico por imagen , Articulación Temporomandibular/cirugía
10.
Nat Commun ; 11(1): 3257, 2020 06 26.
Artículo en Inglés | MEDLINE | ID: mdl-32591522

RESUMEN

Cancer cell metabolism leads to a uniquely acidic microenvironment in solid tumors, but exploiting the labile extracellular pH differences between cancer and normal tissues for clinical use has been challenging. Here we describe the clinical translation of ONM-100, a nanoparticle-based fluorescent imaging agent. This is comprised of an ultra-pH sensitive amphiphilic polymer, conjugated with indocyanine green, which rapidly and irreversibly dissociates to fluoresce in the acidic extracellular tumor microenvironment due to the mechanism of nanoscale macromolecular cooperativity. Primary outcomes were safety, pharmacokinetics and imaging feasilibity of ONM-100. Secondary outcomes were to determine a range of safe doses of ONM-100 for intra-operative imaging using commonly used fluorescence camera systems. In this study (Netherlands National Trial Register #7085), we report that ONM-100 was well tolerated, and four solid tumor types could be visualized both in- and ex vivo in thirty subjects. ONM-100 enables detection of tumor-positive resection margins in 9/9 subjects and four additional otherwise missed occult lesions. Consequently, this pH-activatable optical imaging agent may be clinically beneficial in differentiating previously unexploitable narrow physiologic differences.


Asunto(s)
Acidosis/complicaciones , Nanopartículas/química , Neoplasias/metabolismo , Neoplasias/cirugía , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Fluorescencia , Humanos , Concentración de Iones de Hidrógeno , Masculino , Márgenes de Escisión , Persona de Mediana Edad , Imagen Óptica , Microambiente Tumoral
11.
Ned Tijdschr Tandheelkd ; 127(1): 19-27, 2020 Jan.
Artículo en Holandés | MEDLINE | ID: mdl-32159525

RESUMEN

the bone can still be present long after patients have stopped taking the medication. Patients are often able to report accurately what disorder(s) they have and certain disorders should cause dentists to be alert. Patients who can be defined as the Big Five users of bone-modulating medicaments are: 1. patients with osteoporosis, 2. patients who have been long-term users of glucocorticoids, 3. patients with solid tumours, 4. patients with multiple myeloma and 5. patients with congenital or hereditary bone disorders. These patient groups have an indication for bone-modulating medicaments. These are anti-resorptive medications (such as bisphosphonates and denosumab) or anti-angiogenic medications. By recognising the correct patient group, dentists can ask appropriate questions about the use of medicaments in the present or in the past. A dentist can recognise patients with a risk of medication-related osteonecrosis by using this method.


Asunto(s)
Conservadores de la Densidad Ósea , Efectos Colaterales y Reacciones Adversas Relacionados con Medicamentos , Osteonecrosis , Denosumab , Difosfonatos , Humanos
12.
Int J Oral Maxillofac Surg ; 49(4): 454-460, 2020 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-31506186

RESUMEN

The accuracy of orthognathic surgery has improved with three-dimensional virtual planning. The translation of the planning to the surgical result is reported to vary by >2mm. The aim of this randomized controlled multi-centre trial was to determine whether the use of splintless patient-specific osteosynthesis can improve the accuracy of maxillary translation. Patients requiring a Le Fort I osteotomy were included in the trial. The intervention group was treated using patient-specific osteosynthesis and the control group with conventional osteosynthesis and splint-based positioning. Fifty-eight patients completed the study protocol, 27 in the patient-specific osteosynthesis group and 31 in the control group. The per protocol median anteroposterior deviation was found to be 1.05mm (interquartile range (IQR) 0.45-2.72mm) in the patient-specific osteosynthesis group and 1.74mm (IQR 1.02-3.02mm) in the control group. The cranial-caudal deviation was 0.87mm (IQR 0.49-1.44mm) and 0.98mm (IQR 0.28-2.10mm), respectively, whereas the left-right translation deviation was 0.46mm (IQR 0.19-0.96mm) in the patient-specific osteosynthesis group and 1.07mm (IQR 0.62-1.55mm) in the control group. The splintless patient-specific osteosynthesis method improves the accuracy of maxillary translations in orthognathic surgery and is clinically relevant for planned anteroposterior translations of more than 3.70mm.


Asunto(s)
Procedimientos Quirúrgicos Ortognáticos , Cirugía Asistida por Computador , Diseño Asistido por Computadora , Humanos , Imagenología Tridimensional , Maxilar , Osteotomía Le Fort
13.
Sci Rep ; 9(1): 14395, 2019 10 07.
Artículo en Inglés | MEDLINE | ID: mdl-31591466

RESUMEN

Fracture gap and step-off measurements on 2DCT-slices probably underestimate the complex multi-directional features of tibial plateau fractures. Our aim was to develop a quantitative 3D-CT (Q3DCT) fracture analysis of these injuries. CT-based 3D models were created for 10 patients with a tibial plateau fracture. Several 3D measures (gap area, articular surface involvement, 3D displacement) were developed and tested. Gaps and step-offs were measured in 2D and 3D. All measurements were repeated by six observers and the reproducibility was determined by intra-class correlation coefficients. Q3DCT measurements demonstrated a median gap of 5.3 mm, step-off of 5.2 mm, gap area of 235 mm2, articular surface involvement of 33% and 3D displacement of 6.1 mm. The inter-rater reliability was higher in the Q3DCT than in the 2DCT measurements for both the gap (0.96 vs. 0.81) and step-off (0.63 vs. 0.32). Q3DCT measurements showed excellent reliability (ICC of 0.94 for gap area, 1 for articular surface involvement and 0.99 for 3D displacement). Q3DCT fracture analysis of tibial plateau fractures is feasible and shows excellent reliability. 3D measurements could be used together with the current classification systems to quantify the true extent of these complex multi-directional fractures in a standardized way.


Asunto(s)
Imagenología Tridimensional , Fracturas de la Tibia/diagnóstico por imagen , Tomografía Computarizada por Rayos X , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Adulto Joven
14.
PLoS One ; 14(6): e0218612, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31216346

RESUMEN

INTRODUCTION: Acetabular fractures consist of complex fracture patterns whereby bone fragments are displaced in different directions. Two-dimensional computed tomography (2DCT) gap and step-off measurements tend to underestimate the multidirectional features of these fractures. The aim was to develop a three-dimensional computed tomography (3DCT) measurement method for acetabular fractures and validate whether this method will provide an observer independent fracture characterization. MATERIALS AND METHODS: Sixty patients, operated for an acetabular fracture between 2007 and 2018, were included. The displacement was measured on the pre- and postoperative CT scans. Pre- and postoperative CT-based 3D models were made for each patient. Multiple 3D measurements, namely the 3D step-off, gap and the total gap area were introduced to quantify the preoperative and postoperative displacement. The Wilcoxon signed rank analysis was used to compare the 2DCT and 3DCT measurements. RESULTS: The preoperative displacement was significantly underestimated by 2DCT measurements in comparison with 3DCT measurements (2D vs. 3D; step-off 8 vs. 16 mm with P < 0.001; gap 19 vs. 21 mm with P = 0.001). The same applies to the postoperative residual displacement (2D vs. 3D; step-off 0 vs. 6 mm; gap 3 vs. 8 mm; P < 0.001). The total gap area, defined as the surface area between all fracture lines in the 3D model, was measured for each patient, resulting in a median value of 722 mm2 preoperatively and 168 mm2 postoperatively, with excellent inter- and intra-rater reliability. CONCLUSION: 2DCT measurements tend to underestimate the initial and residual displacement in complex acetabular fractures. A 3DCT analysis of these injuries was developed to overcome this and should be used in addition to the Judet/Letournel and AO/OTA classification systems, in order to provide an observer independent quantifiable fracture description and accurate assessment of the fracture reduction.


Asunto(s)
Acetábulo/diagnóstico por imagen , Fracturas Óseas/diagnóstico por imagen , Modelación Específica para el Paciente , Tomografía Computarizada por Rayos X/métodos , Acetábulo/lesiones , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad
15.
Transplant Proc ; 50(10): 2997-3009, 2018 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-30577159

RESUMEN

BACKGROUND: To increase the number of postmortem organ and tissue donors, donor registries (DRs) have been introduced. The aim of this review was to understand why people in nations with an Opt-in system, who are for or against donation after death, do not register in the DR. Knowing these barriers will help in developing policies to increase the registration rate in the DR. METHODS: For this review, 2 authors independently assessed the eligibility of the identified studies from 2000 to 2015 in the Pubmed- Medline database. Included were observational and interventional studies concerned with reported barriers to residents joining the national DR in Denmark, The Netherlands, and the United Kingdom. RESULTS: We included 15 relevant articles for the review. The main barriers to signing the DR in nations using the Opt-in system were: religion; medical mistrust, anxiety, and affective emotions; lack of information; concern about insufficient time to mourn, and that the funeral may be delayed and the deceased not look presentable; physical integrity; ignorance about how to register in the DR; own benefit; and social status. CONCLUSIONS: The outcome suggests that the main barriers to enrolling in the DR are based on people's doubts about their own ability to perform the registration and cope with the consequences, knowledge, outcome expectations, and concerns about what others will think of them for agreeing to donation. However, not all barriers are easily modifiable, owing to their association with affect or emotions.


Asunto(s)
Sistema de Registros , Donantes de Tejidos/psicología , Donantes de Tejidos/provisión & distribución , Obtención de Tejidos y Órganos/métodos , Dinamarca , Humanos , Países Bajos , Religión , Reino Unido
16.
Ned Tijdschr Tandheelkd ; 125(10): 517-523, 2018 Oct.
Artículo en Holandés | MEDLINE | ID: mdl-30317372

RESUMEN

A 48-year-old man was referred for an evaluation of deviations in the pigmentation of the lower lip, intra-oral swelling and persistent numbness of the sensory area of the left mental nerve. In 2011, the diagnosis lentigo maligna of the lower lip was missed by histopathology of a biopsy performed elsewhere. In 2016, the numbness of the lower lip and chin was diagnosed by a neurologist as numb chin of unknown cause. A biopsy in 2017 showed lentigo maligna of the lower lip alongside a primary mucosal melanoma with significant local invasion. Treatment consisted of a hemimandibulectomy with a supraomohyoid neck dissection of the left side. This case shows the importance of the alarm symptom 'a numb lip' and the corresponding necessity of additional investigation. This article shows avoidable pitfalls that general practitioners, dentists and medical specialists need to be vigilant about.


Asunto(s)
Peca Melanótica de Hutchinson/diagnóstico , Hipoestesia/diagnóstico , Labio/patología , Neoplasias Cutáneas/diagnóstico , Humanos , Hipoestesia/etiología , Masculino , Persona de Mediana Edad , Pigmentación
17.
Oral Oncol ; 81: 22-28, 2018 06.
Artículo en Inglés | MEDLINE | ID: mdl-29884410

RESUMEN

OBJECTIVES: 3D virtual surgical planning (VSP) and guided surgery has been proven to be an effective tool for resection and reconstruction of the mandible. Currently, most widely used 3D VSP approaches to mandibular resection do not include detailed tumour information in the VSP. This manuscript presents a strategy where the aim was to incorporate tumour visualisation into the 3D virtual plan. Three-dimensional VSP of the mandibular resections was based on the fusion of CT and MRI data which was subsequently applied in clinical practice. METHODS: All patients diagnosed with oral squamous cell carcinoma between 2014 and 2017 at the University Medical Centre Groningen were included. The tumour was delineated on the MRI data, after which this dataset was fused with the CT bone data in order to construct a 3D bone and tumour model for virtual resection planning. Guided resections were performed and post-operative evaluation quantified the accuracy of the resection. The histopathological findings and patient and tumour characteristics were compared to those of a historical cohort (2009-2014) of conventional mandibular continuity resections. RESULTS: Twenty-four patients were included in the cohort. The average deviation from planned resection was found to be 2.2 mm. Histopathologic analysis confirmed all resection planes (bone) were tumour free, compared to 96.4% in the historic cohort. CONCLUSION: MRI-CT base tumour visualisation and 3D resection planning is a safe and accurate method for oncologic resection of the mandible. It is an improvement on the current methods reported for 3D resection planning based solely on CT data.


Asunto(s)
Neoplasias de Cabeza y Cuello/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Mandíbula/diagnóstico por imagen , Imagen Multimodal/métodos , Tomografía Computarizada por Rayos X/métodos , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad
18.
J Craniomaxillofac Surg ; 46(6): 1037-1040, 2018 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-29716816

RESUMEN

PURPOSE: In mandibular reconstructive surgery, the osteosynthesis plates require contouring according to the patients' individual anatomical situation. These plates are frequently contoured around a three-dimensional (3D) printed model. However, the translation to the actual patient can introduce inaccuracies and unwanted rotations in the condyles and mandibular ramus, due to malpositioning of the pre-contoured plate. MATERIALS AND METHODS: This article describes an easy-access method for exact translation of the pre-contoured plate to the patient's mandible. This is done by using 3D printed guides that allow pre-drilling of screw holes in both the contour model and the patients' mandible. The accuracy of the Key Printed Solution was analysed by comparing the anatomical landmarks on both the 3D planned and post-operative models. RESULTS: The method was applied to 4 cases. All landmarks were identified on both the 3D planning and post-operative computed tomographic data. This showed an average deviation of 1.0 mm between planning and the post-operative result. The inter-observer variation was 0.6 mm (intra-class correlation, 0.75). CONCLUSION: This article presents an easy-to-use method for pre-bending the osteosynthesis plate and subsequent accurate translation of the intended contour with corresponding screw hole locations. The method was proved to be accurate and time-efficient.


Asunto(s)
Placas Óseas , Fijación Interna de Fracturas/métodos , Mandíbula/cirugía , Reconstrucción Mandibular/métodos , Procedimientos de Cirugía Plástica/métodos , Impresión Tridimensional , Puntos Anatómicos de Referencia , Desviación Ósea/cirugía , Tornillos Óseos , Huesos/anatomía & histología , Huesos/cirugía , Humanos , Mandíbula/anatomía & histología , Tomografía Computarizada por Rayos X
19.
J Craniomaxillofac Surg ; 46(5): 779-784, 2018 May.
Artículo en Inglés | MEDLINE | ID: mdl-29627367

RESUMEN

OBJECTIVES: Patients suffering from osteoarthritis, ankylosis (e.g. post-trauma or tumour) in the temporomandibular joint (TMJ) can present with symptoms such as severely restricted mouth opening, pain or other dynamic restrictions of the mandible. To alleviate the symptoms, a total joint prosthesis can be indicated, such as the Groningen TMJ prosthesis. This was developed as a stock device with a lowered centre of rotation for improved translational and opening capacity. This study aimed to improve the design of the prosthesis, and produce a workflow for a customized Groningen TMJ prosthesis, in order to make it more accurate and predictable. METHODS: The fossa and mandibular components of the Groningen TMJ prosthesis were customized. A series of five human cadavers was operated and bilateral TMJ prostheses were placed using custom cutting and drilling guides. Placement accuracy was evaluated based on post-operative CT data. RESULTS: A total of N = 10 prostheses were placed and analysed. The average Euclidean distance deviation from planned to actual position was 0.81 mm (SD 0.21). All prostheses were placed according to the routine surgical approaches and had an excellent alignment with the bony structures. CONCLUSION: The newly developed custom Groningen TMJ prosthesis can be placed with great accuracy and is the first step for improving TMJ total joint replacement surgery.


Asunto(s)
Prótesis Articulares , Diseño de Prótesis/métodos , Articulación Temporomandibular/cirugía , Humanos , Trastornos de la Articulación Temporomandibular/cirugía
20.
Clin Otolaryngol ; 43(4): 1080-1087, 2018 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-29575685

RESUMEN

OBJECTIVES: In cT1-2N0, oral squamous cell carcinoma (OSCC) occult metastases are detected in 23%-37% of cases. Sentinel lymph node biopsy (SLNB) was introduced in head and neck cancer as a minimally invasive alternative for an elective neck dissection in neck staging. Meta-analyses of SLNB accuracy show heterogeneity in the existing studies for reference standards, imaging techniques and pathological examination. The aim of this study was to assess the sensitivity and negative predictive value (NPV) of the SLNB in detecting occult metastases in cT1-2N0 OSCC in a well-defined cohort. DESIGN: Retrospective study. The SLNB procedure consisted of lymphoscintigraphy, SPECT/CT-scanning and gamma probe detection. Routine follow-up was the reference standard for the SLNB negative neck. Histopathological examination of sentinel lymph nodes (SLN) consisted of step serial sectioning, haematoxylin-eosin and cytokeratin AE1/3 staining. SETTING: Two comprehensive oncology centres. PARTICIPANTS: A total of 91 consecutive patients with primary cT1-2N0 OSCC treated by primary resection and neck staging by SLNB procedure between 2008 and 2016. MAIN OUTCOME MEASURES: Sensitivity and negative predictive value. RESULTS: In all cases, SLNs were harvested. A total of 25 (27%) patients had tumour-positive SLNs. The median follow-up was 32 months (range 2-104). Four patients were diagnosed with an isolated regional recurrence in the SLNB negative neck side resulting in an 85% sensitivity and a 94% NPV. CONCLUSION: In our cohort, the SLNB detected occult metastases in early OSCC with 85% sensitivity and 94% NPV. This supports that SLNB is a reliable procedure for surgical staging of the neck in case of oral cT1-2N0 SCC.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA