Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 33
Filtrar
1.
Transplant Proc ; 50(10): 3544-3548, 2018 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-30577234

RESUMEN

BACKGROUND: Orthotopic liver transplantation (OLT) is the definitive treatment for end-stage liver disease (ESLD). Patients with high acuity ESLD are frequently denied life-saving OLT by transplant centers due to reported inferior outcomes. We sought to analyze the impact of a specialized transplant critical care model (TCCM) on patient access to OLT and survival outcomes in high acuity patients. METHODS: From January 2009 to December 2016, 122 adults were wait-listed at our transplant center with laboratory Model for ESLD ≥35 or Status I. Outcomes in Era I (prior to TCCM) were compared to Era II (TCCM established October 1, 2012). RESULTS: Era II (TCCM) led to a significant increase in patients' access to OLT. Frequency and need to seek OLT at another center dropped 4-fold in Era II. Compared to Era I, the majority of patients in Era II required intensive care unit management (22% vs 83%, P < .01) and renal replacement therapy (11% vs 70%, P < .01) prior to OLT. Despite a higher acuity of illness in Era II, 1-year patient survival was comparable (89% Era I, 80% Era II, P = .35). CONCLUSION: Implementation of a specialized TCCM expanded OLT access to high acuity patients, reduced the need to seek higher level of care elsewhere, and achieved excellent short-term post-transplant survival outcomes.


Asunto(s)
Cuidados Críticos/métodos , Enfermedad Hepática en Estado Terminal/cirugía , Trasplante de Hígado/métodos , Selección de Paciente , Adulto , Enfermedad Hepática en Estado Terminal/mortalidad , Femenino , Supervivencia de Injerto , Humanos , Unidades de Cuidados Intensivos , Trasplante de Hígado/mortalidad , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Resultado del Tratamiento
6.
Anesthesiology ; 94(3): 453-6, 2001 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-11374605

RESUMEN

BACKGROUND: Parameters determining carbon monoxide (CO) concentrations produced by anesthetic breakdown have not been adequately studied in clinical situations. The authors hypothesized that these data will identify modifiable risk factors. METHODS: Carbon monoxide concentrations were measured when partially desiccated barium hydroxide lime was reacted with isoflurane (1.5%) and desflurane (7.5%) in a Draeger Narkomed 2 anesthesia machine with a latex breathing bag substituting for a patient. Additional experiments determined the effects of carbon dioxide (0 or 350 ml/min), fresh gas flow rates (1 or 4 l/min), minute ventilation (6 or 18 l/min), or absorbent quantity (1 or 2 canisters). End-tidal anesthetic concentrations were adjusted according to a monochromatic infrared monitor. RESULTS: Desflurane produced approximately 20 times more CO than isoflurane when completely dried absorbents were used. Peak CO concentrations approached 100,000 ppm with desflurane. Traces of water remaining after a 66-h drying time (one weekend) markedly reduced the generation of CO compared with 2 weeks of drying. Reducing the quantity of desiccated absorbent by 50% reduced the total CO production by 40% in the first hour. Increasing the fresh gas flow rate from 1 to 4 l/min increased CO production by 67% in the first hour but simultaneously decreased average inspiratory concentrations by 53%. Carbon dioxide decreased CO production by 12% in completely desiccated absorbents. CONCLUSION: Anesthetic identity, fresh gas flow rates, absorbent quantity, and water content are the most important factors determining patient exposures. Minute ventilation and carbon dioxide production by the patient are relatively unimportant.


Asunto(s)
Anestesia por Inhalación , Anestésicos por Inhalación/química , Monóxido de Carbono/química , Isoflurano/análogos & derivados , Isoflurano/química , Absorción , Dióxido de Carbono/química , Desflurano
7.
Anesthesiology ; 94(3): 457-60, 2001 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-11374606

RESUMEN

BACKGROUND: Carbon monoxide (CO) is produced by reaction of isoflurane, enflurane, and desflurane in desiccated carbon dioxide absorbents. The inspiratory CO concentration depends on the dryness and identity of the absorbent and anesthetic. The adaptation of existing mathematical models to a rebreathing circuit allows identification of patient factors that predispose to more severe exposures, as identified by carboxyhemoglobin concentration. METHODS: From our companion study, the authors used quantitative in vitro CO production data for 60 min at 7.5% desflurane or 1.5% isoflurane at 1 l/min fresh gas flow. The carboxyhemoglobin concentration was calculated by iteratively solving the Coburn Forster Kane equation modified for a rebreathing system that incorporates the removal of CO by patient absorption. Demonstrating good fit of predicted carboxyhemoglobin concentrations to published data from animal and human exposures validated the model. Carboxyhemoglobin concentrations were predicted for exposures of various severity, patients of different sizes, hematocrit, and fraction of inspired oxygen. RESULTS: The calculated carboxyhemoglobin concentrations closely predicted the experimental results of other investigators, thereby validating the model. These equations indicate the severity of CO poisoning is inversely related to the hemoglobin quantity of a subject. Fraction of inspired oxygen had the greatest effect in patients of small size with low hematocrit values, where equilibrium and not the rate of uptake determined carboxyhemoglobin concentrations. CONCLUSION: This model predicts that patients with low hemoglobin quantities will have more severe CO exposures based on the attainment of a higher carboxyhemoglobin concentration. This includes patients of small size (pediatric population) and patients with anemia.


Asunto(s)
Anestésicos por Inhalación/química , Monóxido de Carbono/química , Isoflurano/análogos & derivados , Isoflurano/química , Modelos Teóricos , Carboxihemoglobina/química , Desflurano , Hematócrito , Humanos , Respiración
11.
Anesth Analg ; 89(6): 1393-9, 1999 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-10589614

RESUMEN

UNLABELLED: Perioperative malignant ventricular tachyarrhythmias pose an imminent clinical danger by potentially precipitating myocardial ischemia and severely compromising hemodynamics. Thus, immediate and effective therapy is required, which is not always provided by currently recommended IV drug regimens, indicating a need for more effective drugs. We examined antiarrhythmic effects of the new benzofurane compound E 047/1 on spontaneous ventricular tachyarrhythmia in a conscious dog model. One day after experimental myocardial infarction, 40 dogs exhibiting tachyarrhythmia randomly received (bolus plus 1-h infusion) E 047/1 6 mg/kg plus 6 mg x kg(-1) x h(-1), lidocaine 1 mg/kg plus 4.8 mg x kg(-1) x h(-1), flecainide 1 mg/kg plus 0.05 mg x kg(-1) x h(-1), amiodarone 10 mg/kg plus 1.8 mg x kg(-1) x h(-1), or bretylium 10 mg/kg plus 20 mg x kg(-1) x h(-1). Electrocardiogram was evaluated for number of premature ventricular contractions (PVC), normally conducted beats originating from the sinoatrial node, and episodes of ventricular tachycardia. Immediately after the bolus, E 047/1 reduced PVCs by 46% and increased sinoatrial beats from 4 to 61 bpm. The ratio of PVCs to total beats decreased from 98% to 58%. Amiodarone and flecainide exhibited antiarrhythmic effects with delayed onset. Lidocaine did not suppress PVCs significantly, and bretylium was proarrhythmic. The antiarrhythmic E 047/1 has desirable features, suppressing ischemia-induced ventricular tachyarrhythmia quickly and efficiently, and may be a useful addition to current therapeutic regimens. IMPLICATIONS: Life-threatening arrhythmias of the heart after myocardial infarction or ischemia may be treated quickly and efficiently by the new drug E 047/1.


Asunto(s)
Antiarrítmicos/farmacología , Arritmias Cardíacas/tratamiento farmacológico , Benzofuranos/farmacología , Isquemia Miocárdica/complicaciones , Animales , Antiarrítmicos/sangre , Antiarrítmicos/farmacocinética , Arritmias Cardíacas/sangre , Arritmias Cardíacas/etiología , Benzofuranos/sangre , Benzofuranos/farmacocinética , Presión Sanguínea/efectos de los fármacos , Peso Corporal/efectos de los fármacos , Vasos Coronarios/cirugía , Perros , Excipientes/administración & dosificación , Frecuencia Cardíaca/efectos de los fármacos , Infusiones Intravenosas , Ligadura , Isquemia Miocárdica/sangre , Isquemia Miocárdica/etiología , Proyectos Piloto , Polisorbatos/administración & dosificación
12.
Anesth Analg ; 89(4): 856-60, 1999 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-10512255

RESUMEN

UNLABELLED: We tested the hypothesis that acute smoking is associated with ST segment depression during general anesthesia in patients without ischemic heart disease. The carbon monoxide (CO) concentration in expired gas and hemodynamic data was measured during general anesthesia for noncardiac or nonperipheral vascular surgery in patients without symptoms or evidence of ischemic heart disease. Increased expired CO concentrations are indicators of recent smoking. Logistic regression analysis identified significant predictors of ST segment depression > or = 1 mm. Both rate pressure product (odds ratio 1.20 for each increase of 1000, 95% confidence interval = 1.04-1.41, P = 0.007) and expired CO concentration (odds ratio 1.05 for each part per million increase, 95% confidence interval = 1.03-1.08, P = 0.001) were significant predictors of ST segment depression when considered simultaneously. Males demonstrated a lower probability of having an episode of ST depression (odds ratio = 0.16, P = 0.01), but this did not change the relationship between rate pressure product and CO as predictors of ST depression. Approximately 25% of chronically smoking patients smoked on the morning of surgery despite instructions not to smoke. IMPLICATIONS: Patients under age 65 without symptoms of ischemic heart disease who smoked shortly before surgery had more episodes of rate pressure product-related ST segment depression than nonsmokers, prior smokers, or chronic smokers who did not smoke before surgery. Females were at greater risk of ST depression than males.


Asunto(s)
Anestesia General , Electrocardiografía , Fumar/fisiopatología , Enfermedad Aguda , Adulto , Anestésicos por Inhalación/administración & dosificación , Presión Sanguínea/fisiología , Monóxido de Carbono/análisis , Enfermedad Crónica , Intervalos de Confianza , Desflurano , Femenino , Predicción , Frecuencia Cardíaca/fisiología , Humanos , Isoflurano/administración & dosificación , Isoflurano/análogos & derivados , Modelos Logísticos , Masculino , Éteres Metílicos/administración & dosificación , Persona de Mediana Edad , Oportunidad Relativa , Sevoflurano , Factores Sexuales , Fumar/metabolismo , Cese del Hábito de Fumar , Espirometría , Procedimientos Quirúrgicos Vasculares
13.
N Engl J Med ; 340(16): 1291; author reply 1292, 1999 Apr 22.
Artículo en Inglés | MEDLINE | ID: mdl-10215500
17.
Anesthesiology ; 87(2): 228-34, 1997 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-9286885

RESUMEN

BACKGROUND: Carbon monoxide forms via reaction of isoflurane, enflurane, and desflurane with dried CO2 absorbents. The authors hypothesize that interventions by nonphysician support personnel to decrease absorbent drying will decrease the exposure rate of patients to carbon monoxide from anesthetic breakdown. METHODS: In the control group, all anesthetizing personnel were made aware of the factors enabling CO generation from anesthetic breakdown, and prevention techniques were left to the anesthetizing personnel. After data collection was complete, the following interventions were initiated to reduce absorbent drying: Anesthesia technicians and housekeeping personnel were instructed to turn off all anesthesia machines after the last case of the day in each room, and the CO2 absorbent was changed each morning if fresh gas was found flowing. Baralyme was used in all phases of this study. RESULTS: Five cases of intraoperative carbon monoxide exposure occurred among 1,085 (0.46%) first cases in the control group. Postintervention, patient carbon monoxide exposures decreased (P < 0.05), with one exposure among 1,961 (0.051%) first cases in the main operating room. Two exposures among 68 (2.9%) first cases occurred in remote locations (P < 0.001) versus main operating room. Predisposing factors for absorbent drying include the prolonged use of anesthesia machines for monitored anesthesia care, inappropriate drying techniques for expiratory flowmeters, understaffing of support personnel, and anesthesia in remote locations. CONCLUSIONS: These interventions reduced patient exposure to carbon monoxide. Monitoring for carbon monoxide exposures during general anesthesia may be necessary to recognize and end patient exposures that occur despite preventative measures.


Asunto(s)
Anestesia General/métodos , Dióxido de Carbono/química , Intoxicación por Monóxido de Carbono/prevención & control , Enflurano/química , Isoflurano/análogos & derivados , Isoflurano/química , Adsorción , Anestesia General/instrumentación , Carboxihemoglobina/análisis , Desflurano , Estudios de Evaluación como Asunto , Humanos
18.
J Clin Monit ; 13(3): 149-55, 1997 May.
Artículo en Inglés | MEDLINE | ID: mdl-9234084

RESUMEN

OBJECTIVE: Trifluoromethane and CO are produced simultaneously during the breakdown of isoflurane and desflurane by dry CO2 absorbents. Trifluoromethane interferes with anesthetic agent monitoring, and the interference can be used as a marker to indicate anesthetic breakdown with CO production. This study tests representative types of gas monitors to determine their ability to provide a clinically useful warning of CO production in circle breathing systems. METHODS: Isoflurane and desflurane were reacted with dry Baralyme at 45 degrees C. Standardized samples of breakdown products were created from mixtures of reacted and unreacted gases to simulate the partial degrees of reaction which might result during clinical episodes of anesthetic breakdown using 1% or 2% isoflurane and 6% or 12% desflurane. These mixtures were measured by the monitors tested, and the indication of the wrong agent or a mixture of agents due to the presence of trifluoromethane was recorded and related to the CO concentration in the gas mixtures. RESULTS: When presented with trifluoromethane from anesthetic breakdown, monochromatic infrared monitors displayed inappropriately large amounts of isoflurane or desflurane. Agent identifying infrared and Raman scattering monitors varied in their sensitivity to trifluoromethane. Mass spectrometers measuring enflurane at mass to charge = 69 were most sensitive to trifluoromethane. CONCLUSION: Monochromatic infrared monitors were unable to indicate anesthetic breakdown via interference by trifluoromethane, but did indicate falsely elevated anesthetic concentrations. Agent identifying infrared and Raman monitors provided warning of desflurane breakdown via the interference of trifluoromethane by displaying the wrong agent or mixed agents, but may not be sensitive enough to warn of isoflurane breakdown Some mass spectrometers provided the most sensitive warnings to anesthetic breakdown via trifluoromethane, but additional data processing by some patients monitor units reduced their overall effectiveness.


Asunto(s)
Contaminantes Ocupacionales del Aire/análisis , Anestésicos por Inhalación , Monóxido de Carbono/análisis , Clorofluorocarburos de Metano , Monitoreo del Ambiente/instrumentación , Desflurano , Humanos , Isoflurano/análogos & derivados , Espectrometría de Masas , Espectrofotometría Infrarroja , Espectrometría Raman
19.
J Clin Monit ; 13(6): 357-62, 1997 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-9495287

RESUMEN

OBJECTIVE: The passage of volatile anesthetic agents through accidentally dried CO2 absorbents in anesthesia circuits can result in the chemical breakdown of anesthetics with production of greater than 10000 ppm carbon monoxide (CO). This study was designed to evaluate a portable CO monitor in the presence of volatile anesthetic agents. METHODS: Two portable CO monitors employing electrochemical sensors were tested to determine the effects of anesthetic agents, gas sample flow rates, and high CO concentrations on their electrochemical sensor. The portable CO monitors were exposed to gas mixtures of 0 to 500 ppm CO in either 70% nitrous oxide, 1 MAC concentrations of contemporary volatile anesthetics, or reacted isoflurane or desflurane (containing CO and CHF3) in oxygen. The CO measurements from the electrochemical sensors were compared to simultaneously obtained samples measured by gas chromatography (GC). Data were analyzed by linear regression. RESULTS: Overall correlation between the portable CO monitors and the GC resulted in an r2 value >0.98 for all anesthetic agents. Sequestered samples produced an exponential decay of measured CO with time, whereas stable measurements were maintained during continuous flow across the sensor. Increasing flow rates resulted in higher CO readings. Exposing the CO sensor to 3000 and 19000 ppm CO resulted in maximum reported concentrations of approximately 1250 ppm, with a prolonged recovery. CONCLUSIONS: Decrease in measured concentration of the sequestered samples suggests destruction of the sample by the sensor, whereas a diffusion limitation is suggested by the dependency of measured value upon flow. Any value over 500 ppm must be assumed to represent dangerous concentrations of CO because of the non-linear response of these monitors at very high CO concentrations. These portable electrochemical CO monitors are adequate to measure CO concentrations up to 500 ppm in the presence of typical clinical concentrations of anesthetics.


Asunto(s)
Anestésicos por Inhalación/análisis , Monóxido de Carbono/análisis , Electroquímica/instrumentación , Anestesia por Circuito Cerrado , Desflurano , Isoflurano/análogos & derivados , Isoflurano/análisis , Monitoreo Intraoperatorio/instrumentación
20.
Anesth Analg ; 83(1): 62-7, 1996 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-8659767

RESUMEN

Since bupivacaine and epinephrine may both precipitate dysrhythmias, circulating bupivacaine during regional anesthesia could potentiate dysrhythmogenic effects of epinephrine. We therefore examined whether bupivacaine alters the dysrhythmogenicity of subsequent administration of epinephrine in conscious, healthy dogs and in anesthetized dogs with myocardial infarction. Forty-one conscious dogs received 10 micrograms.kg-1.min-1 epinephrine. Seventeen animals responded with ventricular tachycardia (VT) within 3 min. After 3 h, these responders randomly received 1 or 2 mg/kg bupivacaine or saline over 5 min, followed by 10 micrograms.kg-1.min-1 epinephrine. In the bupivacaine groups, epinephrine caused fewer prodysrhythmic effects than without bupivacaine. VT appeared in fewer dogs and at a later time, and there were more sinoatrial beats and less ectopies. Epinephrine shortened QT less after bupivacaine than in control animals. One day after experimental myocardial infarction, six additional halothane-anesthetized dogs received 4 micrograms.kg-1.min-1 epinephrine until VT appeared. After 45 min, 1 mg/kg bupivacaine was injected over 5 min, again followed by 4 micrograms.kg-1.min-1 epinephrine. In these dogs, the prodysrhythmic response to epinephrine was also mitigated by preceding bupivacaine. Bupivacaine antagonizes epinephrine dysrhythmogenicity in conscious dogs susceptible to VT and in anesthetized dogs with spontaneous postinfarct dysrhythmias. There is no evidence that systemic subtoxic bupivacaine administration enhances the dysrhythmogenicity of subsequent epinephrine.


Asunto(s)
Anestésicos Locales/toxicidad , Bupivacaína/toxicidad , Epinefrina/toxicidad , Taquicardia Ventricular/inducido químicamente , Animales , Perros , Electrocardiografía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...