1.
PLoS One ; 19(8): e0309131, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39208284

RESUMEN

OBJECTIVES: Accurate subtyping of breast cancer is crucial for its diagnosis, management, and prognostication. This study aimed to determine the association of magnetic resonance imaging (MRI) breast features with the molecular subtype and aggressiveness of breast cancer in a multi-ethnic population. METHODS: Treatment-naive patients with invasive breast carcinoma were included in this retrospective study. Breast MRI features were recorded based on the American College of Radiology-Breast Imaging Reporting and Data System (ACR-BIRADS) criteria, with tumour size, and apparent diffusion coefficient value (ADC). The statistical association was tested with Pearson Chi-Square Test of Independence for categorical data or the Kruskal-Wallis/ Mann Whitney U test for numerical data between the MRI features and molecular subtype, receptor status, tumour grade, lymphovascular infiltration (LVI) and axillary lymph node (ALN). Multinomial logistic regression was used to test the predictive likelihood of the significant features. The breast cancer subtypes were determined via immunohistochemistry (IHC) and dual-color dual-hapten in-situ hybridization (D-DISH). The expression statuses of ER, PR, and HER-2, LVI, and ALN were obtained from the histopathology report. The ER / PR / HER-2 was evaluated according to the American Society of Clinical Oncology / College of American Pathologists. RESULTS: The study included 194 patients; 41.8% (n = 81) Chinese, 40.7% (n = 79) Malay, and 17.5% (n = 34) Indian, involving 71.6%(n = 139) luminal-like, 12.9%(n = 25) HER-2 enriched, and 15.5%(n = 30) Triple-negative breast cancer (TNBC). TNBC was associated with rim enhancement (p = 0.002) and peritumoral oedema (p = 0.004). HER-2 enriched tumour was associated with larger tumour size (p = 0.041). Luminal-like cancer was associated with irregular shape (p = 0.005) with circumscribed margin (p = 0.003). Other associations were ER-negative tumour with circumscribed margin (p = 0.002) and PR-negative with round shape (p = 0.001). Tumour sizes were larger in ER-negative (p = 0.044) and PR-negative (p = 0.022). Rim enhancement was significantly associated with higher grade (p = 0.001), and moderate peritumoral oedema with positive axillary lymph node (p = 0.002). CONCLUSION: Certain MRI features can be applied to differentiate breast cancer molecular subtypes, receptor status and aggressiveness, even in a multi-ethnic population.


Asunto(s)
Neoplasias de la Mama , Imagen por Resonancia Magnética , Humanos , Femenino , Neoplasias de la Mama/patología , Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/genética , Persona de Mediana Edad , Imagen por Resonancia Magnética/métodos , Adulto , Estudios Retrospectivos , Anciano , Receptores de Estrógenos/metabolismo , Receptor ErbB-2/metabolismo , Receptor ErbB-2/genética , Receptores de Progesterona/metabolismo , Etnicidad
2.
J Clin Med ; 13(16)2024 Aug 22.
Artículo en Inglés | MEDLINE | ID: mdl-39201109

RESUMEN

Background/Objectives: Radiography is an essential and low-cost diagnostic method in pulmonary medicine that is used for the early detection and monitoring of lung diseases. An adequate and consistent image quality (IQ) is crucial to ensure accurate diagnosis and effective patient management. This pilot study evaluates the feasibility and effectiveness of the International Atomic Energy Agency (IAEA)'s remote and automated quality control (QC) methodology, which has been tested in multiple imaging centers. Methods: The data, collected between April and December 2022, included 47 longitudinal data sets from 22 digital radiographic units. Participants submitted metadata on the radiography setup, exposure parameters, and imaging modes. The database comprised 968 exposures, each representing multiple image quality parameters and metadata of image acquisition parameters. Python scripts were developed to collate, analyze, and visualize image quality data. Results: The pilot survey identified several critical issues affecting the future implementation of the IAEA method, as follows: (1) difficulty in accessing raw images due to manufacturer restrictions, (2) variability in IQ parameters even among identical X-ray systems and image acquisitions, (3) inconsistencies in phantom construction affecting IQ values, (4) vendor-dependent DICOM tag reporting, and (5) large variability in SNR values compared to other IQ metrics, making SNR less reliable for image quality assessment. Conclusions: Cross-comparisons among radiography systems must be taken with cautious because of the dependence on phantom construction and acquisition mode variations. Awareness of these factors will generate reliable and standardized quality control programs, which are crucial for accurate and fair evaluations, especially in high-frequency chest imaging.

3.
J Appl Clin Med Phys ; 25(6): e14387, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38778567

RESUMEN

INTRODUCTION: Radiation dose measurement is an essential part of radiotherapy to verify the correct delivery of doses to patients and ensure patient safety. Recent advancements in radiotherapy technology have highlighted the need for fast and precise dosimeters. Technologies like FLASH radiotherapy and magnetic-resonance linear accelerators (MR-LINAC) demand dosimeters that can meet their unique requirements. One promising solution is the plastic scintillator-based dosimeter with high spatial resolution and real-time dose output. This study explores the feasibility of using the LuSy dosimeter, an in-house developed plastic scintillator dosimeter for dose verification across various radiotherapy techniques, including conformal radiotherapy (CRT), intensity-modulated radiation therapy (IMRT), volumetric-modulated arc therapy (VMAT), and stereotactic radiosurgery (SRS). MATERIALS AND METHODS: A new dosimetry system, comprising a new plastic scintillator as the sensing material, was developed and characterized for radiotherapy beams. Treatment plans were created for conformal radiotherapy, IMRT, VMAT, and SRS and delivered to a phantom. LuSy dosimeter was used to measure the delivered dose for each plan on the surface of the phantom and inside the target volumes. Then, LuSy measurements were compared against an ionization chamber, MOSFET dosimeter, radiochromic films, and dose calculated using the treatment planning system (TPS). RESULTS: For CRT, surface dose measurement by LuSy dosimeter showed a deviation of -5.5% and -5.4% for breast and abdomen treatment from the TPS, respectively. When measuring inside the target volume for IMRT, VMAT, and SRS, the LuSy dosimeter produced a mean deviation of -3.0% from the TPS. Surface dose measurement resulted in higher TPS discrepancies where the deviations for IMRT, VMAT, and SRS were -2.0%, -19.5%, and 16.1%, respectively. CONCLUSION: The LuSy dosimeter was feasible for measuring radiotherapy doses for various treatment techniques. Treatment delivery verification enables early error detection, allowing for safe treatment delivery for radiotherapy patients.


Asunto(s)
Estudios de Factibilidad , Aceleradores de Partículas , Fantasmas de Imagen , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Radioterapia de Intensidad Modulada , Humanos , Radioterapia de Intensidad Modulada/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Aceleradores de Partículas/instrumentación , Radiocirugia/métodos , Dosímetros de Radiación , Radioterapia Conformacional/métodos , Radioterapia Conformacional/instrumentación , Radiometría/métodos , Radiometría/instrumentación , Órganos en Riesgo/efectos de la radiación , Neoplasias/radioterapia
4.
Phys Eng Sci Med ; 47(3): 821-832, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38526646

RESUMEN

The use of Al2O3:C-based optically stimulated luminescent dosimeters (OSLDs) in diagnostic X-ray is a challenge because of their energy dependence (ED) and variability of element sensitivity factors (ESFs). This study aims to develop a method to determine ED and ESFs of Landauer nanoDot™ OSLDs for clinical X-ray and investigate the uncertainties associated with ESF and ED correction factors. An area of 2 × 2 cm2 at the central axis of the X-ray field was used to establish the ESFs. A total of 80 OSLDs were categorized into "controlled" (n = 40) and "less-controlled" groups (n = 40). The ESFs of the OSLDs were determined using an 80 kVp X-ray beam quality in free-air geometry. The OSLDs were cross-calibrated with an ion chamber to establish the average calibration coefficient and ESFs. The OSLDs were then irradiated at tube potentials ranging from 50 to 150 kVp to determine their ED. The uniformity of the X-ray field was ± 1.5% at 100 cm source-to-surface distance. The batch homogeneities of user-defined ESFs were 2.4% and 8.7% for controlled and less-controlled OSLDs, respectively. The ED of OSLDs ranged from 1.125 to 0.812 as tube potential increased from 50 kVp to 150 kVp. The total uncertainty of OSLDs, without ED correction, could be as high as 16%. After applying ESF and ED correction, the total uncertainties were reduced to 6.3% in controlled OLSDs and 11.6% in less-controlled ones. OSLDs corrected with user-defined ESF and ED can reduce the uncertainty of dose measurements in diagnostic X-rays, particularly in managing less-controlled OSLDs.


Asunto(s)
Óxido de Aluminio , Dosimetría con Luminiscencia Ópticamente Estimulada , Óxido de Aluminio/química , Incertidumbre , Rayos X , Calibración , Carbono/química , Radiometría , Dosímetros de Radiación , Luminiscencia
5.
Singapore Med J ; 2024 Feb 02.
Artículo en Inglés | MEDLINE | ID: mdl-38305361

RESUMEN

INTRODUCTION: Multiphase computed tomography (CT) using fixed volume contrast media may lead to high radiation exposure and toxicity in patients with low body weight. We evaluated a customised weight-based protocol for multiphase CT in terms of radiation exposure, image quality and cost savings. METHODS: A total of 224 patients were recruited. An optimised CT protocol was applied using 100 kV and 1 mL/kg of contrast media dosing. The image quality and radiation dose exposure of this CT protocol were compared to those of a standard 120 kV, 80 mL fixed volume protocol. The radiation dose information and CT Hounsfield units were recorded. The signal-to-noise ratio, contrast-to-noise ratio (CNR) and figure of merit (FOM) were used as comparison metrics. The images were assessed for contrast opacification and visual quality by two radiologists. The renal function, contrast media volume and cost were also evaluated. RESULTS: The median effective dose was lowered by 16% in the optimised protocol, while the arterial phase images achieved significantly higher CNR and FOM. The radiologists' evaluation showed more than 97% absolute agreement with no significant differences in image quality. No significant differences were found in the pre- and post-CT estimated glomerular filtration rate. However, contrast media usage was significantly reduced by 1,680 mL, with an overall cost savings of USD 421 in the optimised protocol. CONCLUSION: The optimised weight-based protocol is cost-efficient and lowers radiation dose while maintaining overall contrast enhancement and image quality.

6.
Phys Med Biol ; 69(6)2024 Mar 12.
Artículo en Inglés | MEDLINE | ID: mdl-38373345

RESUMEN

Objective.Generally, due to a lack of explainability, radiomics based on deep learning has been perceived as a black-box solution for radiologists. Automatic generation of diagnostic reports is a semantic approach to enhance the explanation of deep learning radiomics (DLR).Approach.In this paper, we propose a novel model called radiomics-reporting network (Radioport), which incorporates text attention. This model aims to improve the interpretability of DLR in mammographic calcification diagnosis. Firstly, it employs convolutional neural networks to extract visual features as radiomics for multi-category classification based on breast imaging reporting and data system. Then, it builds a mapping between these visual features and textual features to generate diagnostic reports, incorporating an attention module for improved clarity.Main results.To demonstrate the effectiveness of our proposed model, we conducted experiments on a breast calcification dataset comprising mammograms and diagnostic reports. The results demonstrate that our model can: (i) semantically enhance the interpretability of DLR; and, (ii) improve the readability of generated medical reports.Significance.Our interpretable textual model can explicitly simulate the mammographic calcification diagnosis process.


Asunto(s)
Aprendizaje Profundo , Radiómica , Redes Neurales de la Computación , Mamografía/métodos , Informe de Investigación
7.
Skeletal Radiol ; 53(3): 455-463, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37594519

RESUMEN

OBJECTIVE: To establish the scanning protocol for 2-dimensional shear wave elastography (SWE) on normal entheses by investigating the possible confounding factors that may increase the variability of measured elasticity. MATERIAL AND METHODS: 30 normal quadriceps entheses were scanned using SWE to compare the stiffness and coefficient variation by changing the ultrasonic coupling gel thickness, knee position, region of interest size, and scanning plane. RESULTS: No significant difference in median shear wave velocity (SWV) was observed in different coupling gel thicknesses. The median SWV was higher in the knee flexion position than in the extended position (p < 0.001). Increased knee flexion led to stiffer quadriceps enthesis and higher SWV (ρ = 0.8, p < 0.001). The median SWV was higher when the diameter region of interest was 4.0 mm than 2.0 mm (p = 0.001). The median SWV was higher in the transverse plane than in the longitudinal plane (p < 0.001). Strong correlation was found between SWV and the degree of the shear wave to muscle fiber direction (ρ = 0.8, p < 0.001). The coefficient variation was lower in a gel thickness of 2.5 cm, with an extended knee, a region of interest of 2.0 mm, and a longitudinal plane (p > 0.05). For interobserver reliability for the proposed protocol, the intraclass correlation coefficients was 0.763. CONCLUSION: In this study, we determined supine position with the knee extended; using 2.0 mm diameter region of interest and image acquisition at the longitudinal plane with thicker layer coupling gel seems most appropriate to reliably image healthy quadriceps entheses with SWE.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Humanos , Diagnóstico por Imagen de Elasticidad/métodos , Reproducibilidad de los Resultados
8.
Phys Eng Sci Med ; 47(1): 17-29, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38078996

RESUMEN

Chronic kidney disease is a leading public health problem worldwide. The global prevalence of chronic kidney disease is nearly five hundred million people, with almost one million deaths worldwide. Estimated glomerular filtration rate, imaging such as conventional ultrasound, and histopathological findings are necessary as each technique provides specific information which, when taken together, may help to detect and arrest the development of chronic kidney disease, besides managing its adverse outcomes. However, estimated glomerular filtration rate measurements are hampered by substantial error margins while conventional ultrasound involves subjective assessment. Although histopathological assessment is the best tool for evaluating the severity of the renal pathology, it may lead to renal insufficiency and haemorrhage if complications occurred. Ultrasound shear wave elastography, an emerging imaging that quantifies tissue stiffness non-invasively has gained interest recently. This method applies acoustic force pulses to generate shear wave within the tissue that propagate perpendicular to the main ultrasound beam. By measuring the speed of shear wave propagation, the tissue stiffness is estimated. This paper reviews the literature and presents our combined experience and knowledge in renal shear wave elastography research. It discusses and highlights the confounding factors on shear wave elastography, current and future possibilities in ultrasound renal imaging and is not limited to new sophisticated techniques.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Insuficiencia Renal Crónica , Humanos , Diagnóstico por Imagen de Elasticidad/métodos , Insuficiencia Renal Crónica/diagnóstico por imagen , Insuficiencia Renal Crónica/patología , Riñón/diagnóstico por imagen , Riñón/patología , Ultrasonografía/métodos , Física
9.
J Digit Imaging ; 36(4): 1533-1540, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37253893

RESUMEN

This study investigates the feasibility of using texture radiomics features extracted from mammography images to distinguish between benign and malignant breast lesions and to classify benign lesions into different categories and determine the best machine learning (ML) model to perform the tasks. Six hundred and twenty-two breast lesions from 200 retrospective patient data were segmented and analysed. Three hundred fifty radiomics features were extracted using the Standardized Environment for Radiomics Analysis (SERA) library, one of the radiomics implementations endorsed by the Image Biomarker Standardisation Initiative (IBSI). The radiomics features and selected patient characteristics were used to train selected machine learning models to classify the breast lesions. A fivefold cross-validation was used to evaluate the performance of the ML models and the top 10 most important features were identified. The random forest (RF) ensemble gave the highest accuracy (89.3%) and positive predictive value (66%) and likelihood ratio of 13.5 in categorising benign and malignant lesions. For the classification of benign lesions, the RF model again gave the highest likelihood ratio of 3.4 compared to the other models. Morphological and textural radiomics features were identified as the top 10 most important features from the random forest models. Patient age was also identified as one of the significant features in the RF model. We concluded that machine learning models trained against texture-based radiomics features and patient features give reasonable performance in differentiating benign versus malignant breast lesions. Our study also demonstrated that the radiomics-based machine learning models were able to emulate the visual assessment of mammography lesions, typically used by radiologists, leading to a better understanding of how the machine learning model arrive at their decision.


Asunto(s)
Mama , Mamografía , Humanos , Estudios Retrospectivos , Mama/diagnóstico por imagen , Mamografía/métodos , Aprendizaje Automático , Bosques Aleatorios
10.
Br J Radiol ; 96(1144): 20220288, 2023 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-36802861

RESUMEN

OBJECTIVE: Many studies have conflicting findings in using shear wave elastography (SWE) to assess renal fibrosis. This study reviews the use of SWE to evaluate pathological changes in native kidneys and renal allografts. It also tries to elucidate the confounding factors and care taken to ensure the results are consistent and reliable. METHODS: The review was carried out according to the Preferred Reporting Items for Systematic Reviews and Meta-Analysis guidelines. Literature search was conducted in Pubmed, Web of Science and Scopus database up to 23 October 2021. To evaluate risk and bias applicability, the Cochrane risk-of bias tool and GRADE was used. The review was registered under PROSPERO CRD42021265303. RESULTS: A total of 2921 articles were identified. 104 full texts were examined and 26 studies included in systematic review. 11 studies performed on native kidneys and 15 studies on transplanted kidney. A wide range of impact factors was found that affect the accuracy of SWE of renal fibrosis in adult patients. CONCLUSIONS: Compared to point SWE, two-dimensional SWE with elastogram could enable better selection of the region of interest in kidneys, leading to reproducible results. Tracking waves were attenuated as the depth from skin to region of interest increased, therefore, SWE is not recommended for overweight or obese patients. Variable transducer forces might also affect SWE reproducibility, thus, training of operators to ensure consistent operator-dependent transducer forces may be helpful. ADVANCES IN KNOWLEDGE: This review provides a holistic insight on the efficiency of using SWE in evaluating pathological changes in native and transplanted kidneys, thereby contributing to the knowledge of its utilisation in clinical practice.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Humanos , Adulto , Diagnóstico por Imagen de Elasticidad/métodos , Reproducibilidad de los Resultados , Ultrasonografía , Riñón/diagnóstico por imagen , Fibrosis , Cirrosis Hepática
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA