Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 281
Filtrar
1.
ESC Heart Fail ; 2024 Sep 23.
Artículo en Inglés | MEDLINE | ID: mdl-39308333

RESUMEN

AIMS: Mitral transcatheter edge-to-edge repair (M-TEER) is a valid treatment option for severe mitral regurgitation (MR), necessitating accurate risk stratification of M-TEER candidates for effective patient selection, optimal periprocedural care and improved long-term outcomes. The body mass index (BMI) is a simple and practical prognostic index, and the obesity paradox has been widely reported. METHODS AND RESULTS: Between April 2018 and June 2021, 2149 patients undergoing M-TEER were registered in the prospective multicentre registry and classified into three groups: underweight (BMI < 18.5 kg/m2), normal weight (18.5 â‰¦ BMI < 25 kg/m2) and overweight and obese (25 kg/m2 â‰¦ BMI). The impact of underweight on the all-cause, cardiovascular and non-cardiovascular mortality following M-TEER was evaluated [follow-up duration: 436 (363-733) days]. The participants (median BMI: 21.1 kg/m2) were categorized as underweight (n = 450, 20.9%), normal weight (n = 1409, 65.6%) and overweight and obese (n = 290, 13.5%). Compared with the other two groups, the underweight group exhibited several negative prognostic factors, including older age, frailty, no dyslipidaemia, hypoalbuminaemia, residual MR and non-home discharge. Underweight patients had the highest rate of all-cause, cardiovascular and non-cardiovascular mortality, whereas those in the other two groups were similar. As per the multivariate analysis, underweight itself was associated with all-cause mortality (hazard ratio: 1.52, 95% confidence interval: 1.17-1.97, P = 0.009) and cardiovascular mortality (hazard ratio: 1.45, 95% confidence interval: 1.04-2.01, P = 0.028). CONCLUSIONS: Underweight patients had the highest mortality rate after M-TEER. Comorbidities, residual MR, discharge disposition and underweight status were correlated with postprocedural outcome.

2.
Int J Cardiol ; 418: 132595, 2024 Sep 24.
Artículo en Inglés | MEDLINE | ID: mdl-39326702

RESUMEN

BACKGROUND: Optimal medical therapy for patients with secondary mitral regurgitation (SMR) undergoing transcatheter edge-to-edge mitral valve repair (M-TEER) remains unclear. This study aimed to investigate the association between beta-blocker uptitration and clinical outcomes after M-TEER. METHODS: Using data from the Japanese multicenter registry, we examined 1474 patients who underwent M-TEER for SMR between April 2018 and June 2021. Beta-blocker uptitration was defined as an increased dose of beta-blockers 1 month after M-TEER compared with that before M-TEER. The 2-year clinical outcomes were compared between patients with and without beta-blocker uptitration, utilizing multivariable Cox regression analyses and propensity score matching (PSM). RESULTS: Of the 1474 patients who underwent M-TEER, 272 (18.4 %) were receiving increasing doses of beta-blockers at the 1-month follow-up. These patients had lower left ventricular ejection fraction (LVEF) and higher B-type natriuretic peptide levels. Most patients in the beta-blocker uptitration group received less than the target dose of beta-blockers. Multivariable Cox regression analyses showed that beta-blocker uptitration was significantly associated with a lower risk of all-cause (adjusted hazard ratio [HR]: 0.55; 95 % confidence interval [CI]: 0.36-0.84; P = 0.006) and cardiovascular mortalities (adjusted HR: 0.45, 95 % CI: 0.26-0.79, P = 0.006). PSM analyses revealed consistent findings. Subgroup analyses revealed a significant interaction between beta-blocker uptitration and LVEF≤40 % (interaction P = 0.018). CONCLUSIONS: In patients with SMR, beta-blocker uptitration after M-TEER was associated with better clinical outcomes, especially in the group with an LVEF≤40 %. Efforts to uptitrate guideline-directed medical therapy after M-TEER for SMR may be necessary, even if reaching the target dose proves challenging.

3.
JACC Cardiovasc Interv ; 17(18): 2126-2137, 2024 Sep 23.
Artículo en Inglés | MEDLINE | ID: mdl-39322363

RESUMEN

BACKGROUND: The mechanism and impact of mismatch between residual mitral regurgitation (MR) and postprocedural left atrial pressure (LAP) after transcatheter edge-to-edge repair (TEER), which may adversely affect clinical outcome, is of great interest. OBJECTIVES: This study aimed to examine the effect of hemodynamic mismatch after TEER on clinical outcomes in patients with heart failure due to severe MR and investigate the predictive factors for the mismatch using a prospective multicenter registry. METHODS: We categorized 1,477 patients into optimal (residual MR grade ≤1 and postprocedural LAP ≤15 mm Hg), mismatched (residual MR grade >1 or postprocedural LAP >15 mm Hg), and poor (residual MR grade >1 and postprocedural LAP >15 mm Hg) groups and examined their prognosis. The primary endpoint was a composite of all-cause mortality and heart failure hospitalization. RESULTS: There were 927 (62.7%), 459 (31.1%), and 91 (6.2%) patients categorized into optimal, mismatched, and poor groups, respectively. Cox regression analysis, referenced to the optimal group, revealed that the mismatched and poor groups exhibited a higher risk for the primary endpoint (HR: 1.55; 95% CI: 1.28-1.88; and HR: 1.95; 95% CI: 1.38-2.74, respectively). Six risk factors were identified as predictors of hemodynamic mismatch after TEER: body mass index, baseline left atrial volume index, atrial fibrillation, tricuspid annular plane systolic excursion value, preprocedural mean left atrial pressure, and postprocedural mean mitral valve pressure gradient. CONCLUSIONS: Post-TEER hemodynamic mismatch between residual MR and postprocedural LAP was associated with a poor prognosis. Six readily accessible perioperative parameters predict the hemodynamic mismatch. (OCEAN-Mitral registry; UMIN000023653).


Asunto(s)
Función del Atrio Izquierdo , Presión Atrial , Cateterismo Cardíaco , Insuficiencia Cardíaca , Insuficiencia de la Válvula Mitral , Válvula Mitral , Sistema de Registros , Humanos , Insuficiencia de la Válvula Mitral/fisiopatología , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/mortalidad , Femenino , Masculino , Anciano , Cateterismo Cardíaco/efectos adversos , Factores de Riesgo , Válvula Mitral/fisiopatología , Válvula Mitral/cirugía , Válvula Mitral/diagnóstico por imagen , Resultado del Tratamiento , Estudios Prospectivos , Factores de Tiempo , Anciano de 80 o más Años , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/etiología , Insuficiencia Cardíaca/mortalidad , Insuficiencia Cardíaca/diagnóstico , Medición de Riesgo , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Índice de Severidad de la Enfermedad , Persona de Mediana Edad , Recuperación de la Función , Japón
4.
Artículo en Inglés | MEDLINE | ID: mdl-39255370

RESUMEN

BACKGROUND: In patients undergoing transcatheter aortic valve implantation (TAVI) for severe aortic stenosis (AS), data on the differences in subsequent cardiac structure and function among stratified groups with flow gradient patterns through the aortic valve are insufficient. METHODS: In this large multicenter study, 4,523 patients undergoing TAVI for severe AS between 2013 and 2019 were divided into 3 groups according to the following criteria: (1) high-gradient AS (HG-AS) (mean pressure gradient [MPG] ≥40 mmHg), (2) classical low-flow low-gradient AS (cLFLG-AS) (MPG <40 mmHg, left ventricular [LV] ejection fraction [LVEF] <50%), and (3) paradoxical low-flow low-gradient AS (pLFLG-AS) (MPG <40 mmHg, LVEF ≥50% but stroke volume index [SVi] <35 mL/m2). Echocardiography was performed at baseline, post-procedure, and 1 year post-TAVI. RESULTS: 3,697, 507, and 319 patients had HG-AS, cLFLG-AS, and pLFLG-AS, respectively. After adjusting for clinical factors, cLFLG-AS and pLFLG-AS had an approximately 1.5-fold higher 2-year all-cause mortality compared with HG-AS. During 1 year following TAVI, compared with HG-AS, cLFLG-AS showed greater reduction of LV systolic diameter (LVDs) and LV diastolic diameter (LVDd) and greater increase of LVEF (p<0.001 for all), and changes in LV mass index (LVMi) and SVi were comparable (p=0.915 and p=0.821, respectively). However, pLFLG-AS demonstrated less reduction of LVDs and LVDd (p=0.039 and p=0.001, respectively), less improvement of LVEF and LVMi (p=0.045 and p<0.001, respectively), and comparable change in SVi (p=0.364). CONCLUSIONS: During 1 year post-TAVI, compared with HG-AS, cLFLG-AS achieves smaller LV diameters, greater increase in LVEF, and comparable regression of LVMi, whereas pLFLG-AS does not.

5.
JACC Asia ; 4(7): 536-544, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-39101119

RESUMEN

Background: Navitor, an intra-annular self-expanding heart valve (IA-SEV), is the third transcatheter heart valve introduced in Japan (in April 2022) as the next generation of the Portico valve ahead of other Asian countries. Objectives: The purpose of this study was to assess the patient-prosthesis mismatch (PPM) after IA-SEV implantation in Asian patients. Methods: All clinical data were collected from the database of an ongoing prospective Japanese multicenter registry (OCEAN-TAVI [Optimised Catheter Valvular Intervention transcatheter aortic valve implantation]). The primary endpoint was the rate of no PPM; the secondary endpoint included the rate of in-hospital mortality and hemodynamics after IA-SEV implantation. Results: A total of 463 patients (median age 86; 69.7% female) were enrolled in the registry. The percentages of implanted valves sized 23 mm, 25 mm, 27 mm, and 29 mm were 26.1% (n = 121), 41.7% (n = 193), 22.9% (n = 106), and 9.3% (n = 43), respectively. The primary endpoint of no PPM was achieved in 91.7% of the entire cohort and in 87.3%, 94.2%, 91.4%, and 93.0% of each valve size. The rate of in-hospital mortality was 1.9%. Postprocedural mean pressure gradient was 8.3 ± 4.3 mm Hg. The overall rate of pacemaker implantation was 9.7%; the incidence of pacemaker rate tended to be reduced when dividing the first and second half of operator experiences (13.0% vs. 8.0%; P = 0.08). Conclusions: The initial results for the IA-SEV were excellent regarding hemodynamics and reduction of paravalvular leakage regardless of valve size. The IA-SEV is a useful transcatheter heart valve, especially for Asian patients with a high prevalence of small annulus.

7.
ESC Heart Fail ; 2024 Aug 21.
Artículo en Inglés | MEDLINE | ID: mdl-39167499

RESUMEN

AIMS: Mitral stenosis (MS) occasionally coexists with aortic stenosis (AS). Limited data are available regarding the functional class and clinical outcomes of patients who undergo transcatheter aortic valve implantation (TAVI) for combined AS and MS. This study compared the clinical outcomes in patients with and without MS who underwent TAVI for severe AS and assessed the impact of mitral annulus calcification (MAC) severity, transmitral gradient (TMG) and mitral valve area (MVA) on outcomes in patients with combined AS and MS. METHODS: We investigated patients in the OCEAN-TAVI registry who underwent TAVI. MS was defined as an MVA ≤ 1.5 cm2 or TMG ≥ 5 mmHg. The composite of all-cause death and admission for heart failure was compared between patients with and without MS. The impact of MAC, TMG and MVA on outcomes was assessed in patients with combined AS and MS. RESULTS: We identified 106 patients with MS (MAC 84%; TMG 6.4 ± 2.6 mmHg; MVA 1.10 ± 0.31 cm2) and 6570 without MS as controls. The MS group was older (85 ± 5 vs. 84 ± 5 years, P = 0.033), more of women (85 vs. 67%, P < 0.01), and had a higher risk of surgery (the Society of Thoracic Surgeons Mortality Score 8.7 ± 5.1 vs. 7.6 ± 5.9, P = 0.047) than the controls. In the MS group, the New York Heart Association Functional Class was 3 or 4 in 56% of the patients at baseline and 6% at 1 year after TAVI. Thirty-day mortality (2.8% vs. 1.3%, P = 0.18) and early composite outcomes (17% vs. 15%, P = 0.56) were comparable between patients with and without MS. During a median follow-up of 2.1 years, the presence of MS was associated with a higher incidence of adverse events compared with controls (adjusted hazard ratio [HR] 1.84; 95% confidence interval [CI] 1.34-2.51, P < 0.01), even on propensity score matched analysis (adjusted HR 1.91; 95% CI 1.14-3.22, P < 0.01). Moderate or severe MAC contributed to increased risk of adverse events in patients with MS (adjusted HR 2.89; 95% CI 1.20-6.99, P = 0.018), but TMG and MVA did not. CONCLUSIONS: In patients undergoing TAVI for severe AS, those with moderate or severe MS experienced worse outcomes after TAVI compared with those without MS. Patients with combined AS and MS sustained symptom improvement at 1-year post-TAVI. MAC severity was a useful predictor of adverse events compared with MS haemodynamics such as TMG and MVA in patients with combined AS and MS.

8.
Int J Cardiol Heart Vasc ; 53: 101449, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39022741

RESUMEN

Background: Percutaneous left atrial appendage closure (LAAC) is an effective therapy to prevent thromboembolic events among patients with atrial fibrillation (AF). However, since the left atrial appendage (LAA) contributes to left atrial volume and serves as a buffer for increasing left atrial pressure, this procedure may impair left atrium (LA) compliance, enlarge LA, and deteriorate diastolic function. In this study, we sought to investigate the change in left atrial volume index (LAVI) following LAAC and its effect on prognosis. Methods and Results: We analyzed 225 patients from the OCEAN-LAAC registry, an ongoing, multicenter Japanese study. Comparing LAVI measurements at baseline and 6 months after LAAC, no significant increase was observed (55.0 [44.0, 70.0] ml/m2 vs. 55.0 [42.0, 75.6] ml/m2; P = 0.31). However, some patients underwent LAVI increase. Particularly, a smaller LAVI (odds ratio [OR]: 0.98 [95 % confidence interval (CI): 0.97-0.996]) and elevated tricuspid regurgitation pressure (TRPG) at baseline (OR: 1.04 [95 % CI: 1.00 - 1.08]) were significantly related to the increase in LAVI at 6-month follow-up. In addition, a 5 ml/m2 increase in LAVI was significantly associated with subsequent heart failure hospitalization (HFH) (hazard ratio: 3.37 [95 % CI: 1.18-9.65]). This association, however, was not observed in patients with lower baseline LAVI (≤55 ml/m2) but was only seen in those with a baseline LAVI over 55 ml/m2. Conclusion: Our study demonstrated an increase in LAVI after LAAC was related to smaller LAVI or elevated TRPG at baseline. The LAVI increase was significantly associated with subsequent HFH.

9.
Photochem Photobiol Sci ; 23(8): 1509-1519, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38981991

RESUMEN

[32](1,4)Naphthalenophanes, bearing carbon-bridge chains (syn- and anti-NPs) and nitrogen-bridge chains (syn- and anti-ANPs), were synthesized, and their X-ray structures and photoreactions were investigated. The intramolecular separation distance between the naphthalene cores for ANPs was shorter than that for NPs, suggesting that intramolecular interactions between the naphthalene rings  were more efficient for ANPs compared to NPs. Upon photoirradiation at 300 nm, anti-NP, syn-ANP and anti-ANP produced the corresponding intramolecular [π4s + π4s] cycloadducts, whereas syn-NP gave an unidentified complex product mixture. Quantum yields for the photo-consumption (ΦPC) of NPs and ANPs were evaluated to quantitatively compare their photoreactivity. The ΦPC values of ANPs were approximately two-fold higher than those of ANPs.Noteworthily, the ΦPC value of syn-ANP was estimated to be unity. Based on these results we discuss the effects of the alignments of the naphthalene cores (anti vs. syn) and the bridging elements (C-bridge vs. N-bridge) on the photoreaction efficiencies of [32](1,4)naphthalenophanes.

12.
EuroIntervention ; 20(9): 579-590, 2024 May 10.
Artículo en Inglés | MEDLINE | ID: mdl-38726714

RESUMEN

BACKGROUND: Data on the performance of the latest-generation SAPIEN 3 Ultra RESILIA (S3UR) valve in patients who undergo transcatheter aortic valve replacement (TAVR) are scarce. AIMS: We aimed to assess the clinical outcomes, including valve performance, of the S3UR. METHODS: Registry data of 618 consecutive patients with S3UR and of a historical pooled cohort of 8,750 patients who had a SAPIEN 3 (S3) valve and underwent TAVR were collected. The clinical outcomes and haemodynamics, including patient-prosthesis mismatch (PPM), were compared between the 2 groups and in a propensity-matched cohort. RESULTS: The incidence of in-hospital death, vascular complications, and new pacemaker implantation was similar between the S3UR and the S3 groups (allp>0.05). However, both groups showed significant differences in the degrees of paravalvular leakage (PVL) (none-trivial: 87.0% vs 78.5%, mild: 12.5% vs 20.5%, ≥moderate: 0.5% vs 1.1%; p<0.001) and the incidence of PPM (none: 94.3% vs 85.1%, moderate: 5.2% vs 12.8%, severe: 0.5% vs 2.0%; p<0.001). The prevalence of a mean pressure gradient ≥20 mmHg was significantly lower in the S3UR group (1.6% vs 6.2%; p<0.001). Better haemodynamics were observed with the smaller 20 mm and 23 mm S3UR valves. The results were consistent in a matched cohort of patients with S3UR and with S3 (n=618 patients/group). CONCLUSIONS: The S3UR has equivalent procedural complications to the S3 but with lower rates of PVL and significantly better valve performance. The better valve performance of the S3UR, particularly in smaller valve sizes, overcomes the remaining issue of balloon-expandable valves after TAVR.


Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica , Prótesis Valvulares Cardíacas , Sistema de Registros , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Femenino , Masculino , Anciano de 80 o más Años , Anciano , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/fisiopatología , Resultado del Tratamiento , Válvula Aórtica/cirugía , Válvula Aórtica/fisiopatología , Válvula Aórtica/diagnóstico por imagen , Diseño de Prótesis , Hemodinámica , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Mortalidad Hospitalaria
14.
Circ J ; 88(7): 1187-1197, 2024 06 25.
Artículo en Inglés | MEDLINE | ID: mdl-38763735

RESUMEN

BACKGROUND: Limited data are available regarding clinical outcomes after percutaneous left atrial appendage closure using WATCHMAN FLX (WM-FLX) and WATCHMAN-2.5 (WM2.5) devices in Asian patients. METHODS AND RESULTS: Data of 1,464 consecutive patients (WM-FLX, n=909; WM2.5, n=555) were extracted from a Japanese multicenter registry, and clinical data were compared between the 2 groups. No in-hospital deaths, periprocedural stroke, or device embolization occurred. Procedural success was significantly higher in the WM-FLX than WM2.5 group (95.8% vs. 91.9%; P=0.002) owing to the lower incidence of periprocedural pericardial effusion (0.55% vs. 1.8%; P=0.021). No significant differences in all-cause death, postprocedural stroke, and device-related thrombus were observed between the 2 groups. However, the cumulative bleeding rate at 1 year was substantially lower in the WM-FLX group (7.8% vs. 16.4%; P<0.001). Landmark analysis of bleeding events highlighted lower bleeding rates in the WM-FLX than WM2.5 group within the first 6 months (6.4% vs. 14.8%; P<0.001), with comparable bleeding rates over the 6- to 12-month period (1.5% vs. 3.2%, respectively; P=0.065). CONCLUSIONS: This study demonstrated higher early safety and lower 1-year bleeding rates in the WM-FLX than WM2.5 group. The lower bleeding events with WM-FLX are likely due to multiple factors other than purely difference in devices, such as postprocedural drug regimen.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Sistema de Registros , Humanos , Anciano , Apéndice Atrial/cirugía , Masculino , Femenino , Anciano de 80 o más Años , Fibrilación Atrial/cirugía , Japón , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control , Resultado del Tratamiento , Persona de Mediana Edad , Cierre del Apéndice Auricular Izquierdo
15.
Am J Cardiol ; 223: 156-164, 2024 07 15.
Artículo en Inglés | MEDLINE | ID: mdl-38797196

RESUMEN

The hemodynamic performance of self-expandable valves (SEVs) is a preferable choice for small aortic annuli in transcatheter aortic valve replacement (TAVR). However, no data are, so far, available regarding the relation between the size of SEVs and clinical outcomes. This study aimed to evaluate the impact of prosthesis size on adverse events after TAVR using SEVs. We retrospectively analyzed 1,400 patients (23-mm SEV: 13.6%) who underwent TAVR using SEVs at 12 centers. The impact of SEV size on all-cause death and heart failure (HF) after TAVR was evaluated by multivariate Cox regression and propensity score (PS) matching analysis. During the follow-up period (median 511 days), 201 all-cause deaths and 87 HF rehospitalizations were observed. The incidence of all-cause death was comparable between small- (23-mm SEV) and larger-sized (26- or 29-mm SEV) (16.8% vs 13.9%, log-rank p = 0.29). The size of SEV was not associated with a higher incidence of all-cause death (hazard ratio [HR] 1.21, 95% confidence interval [CI] 0.79 to 1.86 in Cox regression; HR 1.31, 95% CI 0.77 to 2.23 in PS matching) and HF after TAVR (subdistribution HR 0.79, 95% CI 0.37 to 1.72 in Cox regression; subdistribution HR 1.00, 95% CI 0.44 to 2.30 in PS matching). The multivariate model including postprocedural prosthesis-patient mismatch showed consistent results. In conclusion, small SEVs had comparable midterm clinical outcomes to larger-sized SEVs, even if the prosthesis-patient mismatch was observed after TAVR.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Complicaciones Posoperatorias , Diseño de Prótesis , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Causas de Muerte/tendencias , Estudios de Seguimiento , Insuficiencia Cardíaca , Incidencia , Complicaciones Posoperatorias/epidemiología , Puntaje de Propensión , Estudios Retrospectivos , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
16.
Heart Vessels ; 39(8): 687-695, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38710808

RESUMEN

BACKGROUND: Severe aortic valve stenosis (AS) and atrial fibrillation (AF) are risk factors of hemodynamic instability in heart failure (HF) management due to low cardiac output, respectively. Therefore, the treatment of HF due to severe AS complicated with AF is anticipated to be difficult. Tolvaptan, a vasopressin V2 receptor inhibitor, is effective in controlling acute decompensated heart failure (ADHF) with hemodynamic stability. However, its clinical efficacy against ADHF caused by AS with AF remains to be determined. METHODS: Clinical information (from September 2014 to December 2017) of 59 patients diagnosed with ADHF due to severe AS (20 patients with AF; 39 patients with sinus rhythm [SR]) was obtained from the LOHAS registry. The registry collected data from seven hospitals and assessed the short-term effects of tolvaptan in patients hospitalized for ADHF with severe AS. We attempted to identify clinical differences from baseline up to 4 days, comparing patients with AF (AF group) versus those with SR (SR group). RESULTS: There were no significant differences between the groups in age (83.7 ± 4.5 vs. 85.8 ± 6.9 years, respectively; p = 0.11) and aortic valve area (0.60 [0.46-0.73] vs. 0.56 [0.37-0.70] cm2, respectively; p = 0.50). However, left atrial volume was larger (104 [85-126] vs. 87 [64-103] mL, respectively; p < 0.01), whereas stroke volume was lower (51.6 ± 14.8 vs. 59.0 ± 18.7 mL, respectively; p = 0.08) in the AF group versus the SR group. Body weight decreased daily from baseline up to day 4 in both groups (from 55.4 to 53.2 kg [p < 0.01] and from 53.5 to 51.0 kg [p < 0.01], respectively) without change in heart rate. Notably, the systolic blood pressure decreased slightly in the AF group after 2 days of treatment with tolvaptan. CONCLUSIONS: Short-term treatment with tolvaptan improved HF in patients hospitalized for severe AS, regardless of the presence of AF or SR. After achieving sufficient diuresis, a slight decrease in blood pressure was observed in the AF group, suggesting an appropriate timeframe for safe and effective use of tolvaptan.


Asunto(s)
Antagonistas de los Receptores de Hormonas Antidiuréticas , Estenosis de la Válvula Aórtica , Fibrilación Atrial , Insuficiencia Cardíaca , Sistema de Registros , Tolvaptán , Humanos , Tolvaptán/uso terapéutico , Masculino , Fibrilación Atrial/tratamiento farmacológico , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico , Femenino , Insuficiencia Cardíaca/tratamiento farmacológico , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/etiología , Insuficiencia Cardíaca/complicaciones , Insuficiencia Cardíaca/diagnóstico , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/tratamiento farmacológico , Estenosis de la Válvula Aórtica/diagnóstico , Antagonistas de los Receptores de Hormonas Antidiuréticas/uso terapéutico , Anciano de 80 o más Años , Resultado del Tratamiento , Índice de Severidad de la Enfermedad , Estudios Retrospectivos , Anciano , Enfermedad Aguda , Japón/epidemiología , Hemodinámica/efectos de los fármacos
17.
Circ Cardiovasc Interv ; 17(6): e013794, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38629311

RESUMEN

BACKGROUND: The extent of cardiac damage and its association with clinical outcomes in patients undergoing transcatheter edge-to-edge repair (TEER) for degenerative mitral regurgitation remains unclear. This study was aimed to investigate cardiac damage in patients with degenerative mitral regurgitation treated with TEER and its association with outcomes. METHODS: We analyzed patients with degenerative mitral regurgitation treated with TEER in the Optimized Catheter Valvular Intervention-Mitral registry, which is a prospective, multicenter observational data collection in Japan. The study subjects were classified according to the extent of cardiac damage at baseline: no extravalvular cardiac damage (stage 0), mild left ventricular or left atrial damage (stage 1), moderate left ventricular or left atrial damage (stage 2), or right heart damage (stage 3). Two-year mortality after TEER was compared using Kaplan-Meier analysis. RESULTS: Out of 579 study participants, 8 (1.4%) were classified as stage 0, 76 (13.1%) as stage 1, 319 (55.1%) as stage 2, and 176 (30.4%) as stage 3. Two-year survival was 100% in stage 0, 89.5% in stage 1, 78.9% in stage 2, and 75.3% in stage 3 (P=0.013). Compared with stage 0 to 1, stage 2 (hazard ratio, 3.34 [95% CI, 1.03-10.81]; P=0.044) and stage 3 (hazard ratio, 4.51 [95% CI, 1.37-14.85]; P=0.013) were associated with increased risk of 2-year mortality after TEER. Significant reductions in heart failure rehospitalization rate and New York Heart Association functional scale were observed following TEER (both, P<0.001), irrespective of the stage of cardiac damage. CONCLUSIONS: Advanced cardiac damage is associated with an increased risk of mortality in patients undergoing TEER for degenerative mitral regurgitation. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: UMIN000023653.


Asunto(s)
Cateterismo Cardíaco , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Válvula Mitral , Sistema de Registros , Humanos , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/mortalidad , Insuficiencia de la Válvula Mitral/fisiopatología , Masculino , Femenino , Anciano , Válvula Mitral/cirugía , Válvula Mitral/fisiopatología , Válvula Mitral/diagnóstico por imagen , Japón , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/mortalidad , Resultado del Tratamiento , Factores de Tiempo , Estudios Prospectivos , Factores de Riesgo , Anciano de 80 o más Años , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Medición de Riesgo , Recuperación de la Función , Lesiones Cardíacas/mortalidad , Lesiones Cardíacas/etiología , Lesiones Cardíacas/terapia , Lesiones Cardíacas/diagnóstico por imagen
18.
JACC Asia ; 4(4): 306-319, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38660100

RESUMEN

Background: Few reports on pre-existing left bundle branch block (LBBB) in patients undergoing transcatheter aortic valve replacement (TAVR) are currently available. Further, no present studies compare patients with new onset LBBB with those with pre-existing LBBB. Objectives: This study aimed to investigate the association between pre-existing or new onset LBBB and clinical outcomes after TAVR. Methods: Using data from the Japanese multicenter registry, 5,996 patients who underwent TAVR between October 2013 and December 2019 were included. Patients were classified into 3 groups: no LBBB, pre-existing LBBB, and new onset LBBB. The 2-year clinical outcomes were compared between 3 groups using Cox proportional hazards models and propensity score analysis to adjust the differences in baseline characteristics. Results: Of 5,996 patients who underwent TAVR, 280 (4.6%) had pre-existing LBBB, while 1,658 (27.6%) experienced new onset LBBB. Compared with the no LBBB group, multivariable Cox regression analysis showed that pre-existing LBBB was associated not only with a higher 2-year all-cause (adjusted HR: 1.39; 95% CI: 1.06-1.82; P = 0.015) and cardiovascular (adjusted HR: 1.60; 95% CI: 1.04-2.48; P = 0.031) mortality, but also with higher all-cause (adjusted HR: 1.43, 95% CI: 1.07-1.91; P = 0.016) and cardiovascular (adjusted HR: 1.81, 95% CI:1.12-2.93; P = 0.014) mortality than the new onset LBBB group. Heart failure was the most common cause of cardiovascular death, with more heart failure deaths in the pre-existing LBBB group. Conclusions: Pre-existing LBBB was independently associated with poor clinical outcomes, reflecting an increased risk of cardiovascular mortality after TAVR. Patients with pre-existing LBBB should be carefully monitored.

19.
ESC Heart Fail ; 11(4): 2159-2171, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38607328

RESUMEN

AIMS: A considerable proportion of candidates for transcatheter aortic valve implantation (TAVI) have underlying heart failure (HF) with preserved ejection fraction (HFpEF), which can be challenging for diagnosis because significant valvular heart disease should be excluded before diagnosing HFpEF. This study investigated the long-term prognostic value of the pre-procedural H2FPEF score in patients with preserved ejection fraction (EF) undergoing TAVI. METHODS AND RESULTS: Patients who underwent TAVI between October 2013 and May 2017 were enrolled from the Optimized CathEter vAlvular iNtervention-Transcatheter Aortic Valve Implantation Japanese multicentre registry. After excluding 914 patients, 1674 patients with preserved EF ≥ 50% (median age: 85 years, 72% female) were selected for calculation of the H2FPEF score and were dichotomized into two groups: the low H2FPEF score [0-5 points; n = 1399 (83.6%)] group and the high H2FPEF score [6-9 points; n = 275 (16.4%)] group. Patients with high H2FPEF scores were associated with a higher prevalence of New York Heart Association Functional Class III/IV (59.3% vs. 43.7%, P < 0.001), diabetes (24.4% vs. 18.5%, P = 0.03), and paradoxical low-flow, low-gradient aortic stenosis (15.9% vs. 6.2%, P < 0.001). These patients showed worse prognoses than those with low H2FPEF scores regarding the cumulative 2 year all-cause mortality (26.3% vs. 15.5%, log-rank P < 0.001), cardiovascular mortality (10.5% vs. 5.4%, log-rank P < 0.001), HF hospitalization (16.2% vs. 6.7%, log-rank P < 0.001), and the composite endpoint of cardiovascular mortality and HF hospitalization (23.8% vs. 10.8%, log-rank P < 0.001). After adjustment for several confounders, the high H2FPEF scores were independently associated with increased risk for all-cause mortality [adjusted hazard ratio (HR), 1.48; 95% confidence interval (CI), 1.09-2.00; P = 0.011] and for the composite endpoint of cardiovascular mortality and HF hospitalization (adjusted HR, 1.95; 95% CI, 1.38-2.74; P < 0.001). Subgroup analysis confirmed the excess risk of high H2FPEF scores relative to low H2FPEF scores for the composite endpoint of cardiovascular mortality and HF hospitalization increased with a lower Society of Thoracic Surgeons (STS) score (STS score <8%: adjusted HR, 2.40; 95% CI, 1.50-3.85; P < 0.001; STS score ≥8%: adjusted HR, 1.34; 95% CI, 0.79-2.28; P = 0.28; Pinteraction = 0.030). CONCLUSIONS: The H2FPEF score is useful for predicting long-term adverse outcomes after TAVI, including all-cause mortality, cardiovascular mortality, and HF hospitalization for patients with preserved EF. More aggressive interventions targeting HFpEF in addition to the TAVI procedure might be relevant in patients with high H2FPEF scores, particularly in those with a lower surgical risk.


Asunto(s)
Estenosis de la Válvula Aórtica , Volumen Sistólico , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Femenino , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Masculino , Anciano de 80 o más Años , Pronóstico , Estenosis de la Válvula Aórtica/cirugía , Volumen Sistólico/fisiología , Estudios de Seguimiento , Factores de Tiempo , Sistema de Registros , Insuficiencia Cardíaca/epidemiología , Japón/epidemiología , Tasa de Supervivencia/tendencias , Estudios Retrospectivos , Factores de Riesgo , Anciano , Medición de Riesgo/métodos
20.
Chem Sci ; 15(6): 1953-1965, 2024 Feb 07.
Artículo en Inglés | MEDLINE | ID: mdl-38332834

RESUMEN

Precise template synthesis will realize three-dimensionally ordered nanoporous graphenes (NPGs) with a spatially controlled seamless graphene structure and fewer edges. These structural features result in superelastic nature, high electrochemical stability, high electrical conductivity, and fast diffusion of gases and ions at the same time. Such innovative 3D graphene materials are conducive to solving energy-related issues for a better future. To further improve the attractive properties of NPGs, we review the template synthesis and its mechanism by chemical vapor deposition of hydrocarbons, analysis of the nanoporous graphene structure, and applications in electrochemical and mechanical devices.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA