1.
Acad Radiol ; 6(2): 94-101, 1999 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-12680431

RESUMEN

RATIONALE AND OBJECTIVES: The authors evaluated the use of MRX-320, a low-attenuation, expansile oral contrast agent, for the demonstration of intestinal ischemia in an animal model. MATERIALS AND METHODS: Nine dogs were given either MRX-320, water, or diatrizoate as an oral contrast agent through a jejunostomy tube. Two dogs received no oral contrast agent. Helical computed tomography (CT) was performed before the intravenous injection of 2.5 mL/kg iohexol at 4 mL/sec, during the arterial phase, and during the portal venous phase. Mesenteric ischemia was surgically induced, and the imaging protocol was repeated. Three readers rated the randomly assigned images for quality and demonstration of ischemia. Attenuation values for the intestinal lumen and wall were recorded. RESULTS: Examinations performed with MRX-320 provided the best discrimination between ischemic and nonischemic conditions (P < .05), followed by examinations with no oral contrast medium, examinations with water, and examinations with diatrizoate. Images obtained with MRX-320 also scored significantly higher on measures of image quality than those obtained with water or no oral contrast medium (P < .05). On images obtained with MRX-320, the bowel lumen measured -836.5 HU (P < .05 compared with other techniques). Water provided the least uniformity of distention, and diatrizoate provided the least mucosal detail. CONCLUSION: The use of MRX-320 as an oral contrast agent with an intravenous bolus of iohexol at CT increased reader confidence for the diagnosis of intestinal ischemia and improved subjective measures of image quality.


Asunto(s)
Medios de Contraste/administración & dosificación , Fluorocarburos , Intestinos/irrigación sanguínea , Isquemia/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Administración Oral , Análisis de Varianza , Animales , Modelos Animales de Enfermedad , Perros , Inyecciones Intravenosas , Yohexol/administración & dosificación , Estadísticas no Paramétricas
2.
Skeletal Radiol ; 24(7): 495-8, 1995 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-8545644

RESUMEN

PURPOSE: To determine the effect of decreasing the field of view (FOV) on the accuracy of MR for diagnosing rotator cuff tears. MATERIAL AND METHODS: One hundred shoulder MR scans with surgical correlation were evaluated for the presence or absence of a cuff tear. The sensitivity and specificity of MR relative to the surgical results were determined for the 59 patients scanned with a 24-cm FOV, and the 41 patients scanned with an 18-cm FOV. All other imaging parameters including acquisition time were identical. The sensitivity and specificity of the two groups were compared using a t-test. RESULTS: The specificity of MR for diagnosing a rotator cuff tear improved from 0.65 for the 24-cm FOV group to 0.89 for the 18-cm FOV group (P = 0.04). The sensitivity changed from 0.91 to 0.96 (P = 0.25). CONCLUSION: Reducing the FOV from 24 cm to 18 cm results in a statistically significant improvement in specificity of MR for diagnosing rotator cuff tears.


Asunto(s)
Imagen por Resonancia Magnética , Lesiones del Manguito de los Rotadores , Adulto , Artroscopía , Femenino , Humanos , Masculino , Manguito de los Rotadores/patología , Sensibilidad y Especificidad , Traumatismos de los Tendones/diagnóstico , Traumatismos de los Tendones/patología
3.
AJR Am J Roentgenol ; 164(6): 1391-5, 1995 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-7754880

RESUMEN

Abdominal hernias remain a common and vexing problem for both clinicians and radiologists. Unlike inguinal hernias, which are usually diagnosed clinically and are amenable to minor surgical repair, internal hernias can be difficult to diagnose, require more extensive surgical intervention, and have an increased risk of serious complications. Additionally, it is important to recognize structures contained within a hernia sac, so that precautions are taken at surgery. Therefore, accurate preoperative diagnosis can lead to more timely and appropriate surgical management. Abdominal imaging is often the first clue to the correct diagnosis. In the past, the diagnosis of a hernia was either made clinically, with plain radiographs, or with barium studies [1]. Currently, specific diagnoses are made more frequently by CT in patients with nonspecific abdominal complaints [2]. The CT findings may be subtle or confusing; therefore, familiarity with a broad range of imaging appearances can help the radiologist make an early and specific diagnosis of abdominal hernia.


Asunto(s)
Hernia Ventral/diagnóstico por imagen , Tomografía Computarizada por Rayos X , Adolescente , Adulto , Anciano , Niño , Femenino , Humanos , Masculino , Persona de Mediana Edad
4.
Skeletal Radiol ; 23(7): 541-5, 1994 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-7824983

RESUMEN

Most magnetic resonance (MR) studies evaluating the rotator cuff for tears have used T2-weighted imaging in the coronal oblique and sagittal oblique planes. T2*-weighted gradient echo imaging, however, has advantages over spin echo imaging, including contiguous slices without cross-talk, high contrast around the cuff, and intrinsically shorter imaging times which can be used to increase the number of signals averaged and thus improve the signal-to-noise ratio. We reviewed the shoulder MR scans of 87 consecutive patients who underwent both a MR scan and a shoulder arthroscopy during which the size of tears, if present, was graded. The reviewers were blinded as to the history and arthroscopic results. The MR scans included oblique coronal T2*-weighted gradient echo and oblique sagittal T2-weighted spin echo images. MR cuff grades were correlated with arthroscopic findings. For complete tears, the sensitivity of MR was 0.91 and the specificity 0.95. For partial tears, the sensitivity was 0.74 and the specificity 0.87. This accuracy is similar to two-plane T2-weighted imaging as previously reported in the literature. There was a statistically significant correlation (p < 0.0005) between the cuff grade as determined by MR and the arthroscopic findings.


Asunto(s)
Imagen por Resonancia Magnética , Lesiones del Manguito de los Rotadores , Heridas y Lesiones/diagnóstico , Adulto , Artroscopía , Femenino , Humanos , Imagen por Resonancia Magnética/métodos , Masculino , Manguito de los Rotadores/cirugía , Sensibilidad y Especificidad , Articulación del Hombro/patología , Heridas y Lesiones/cirugía
5.
AJR Am J Roentgenol ; 161(1): 101-7, 1993 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-8517286

RESUMEN

OBJECTIVE: The presence of intrameniscal signal in contact with the surface is a commonly used criterion for the diagnosis of meniscal tear. This signal presumably represents the actual tear in the meniscus. However, some menisci with signal that contacts the surface are noted to be intact at arthroscopy whereas other menisci that have no signal in contact with the surface are found to be torn. We investigated the relationship between the presence of a meniscal tear at arthroscopy and the location within the menisci of signal that contacted the surface. We hypothesized that patterns were present that would improve the accuracy of MR diagnosis of a meniscal tear. MATERIALS AND METHODS: We reviewed the MR and arthroscopic findings from 200 consecutive patients who had both knee MR examinations and knee arthroscopy. There were 108 medial and 58 lateral meniscal tears on arthroscopy. Each MR examination was reviewed for three aspects of intrameniscal signal: the number of images showing signal possibly or definitely contacting the surface, the specific surfaces involved, and the signal location. The coronal and sagittal images were evaluated separately. We correlated each of these features with the presence of a meniscal tear at arthroscopy. RESULTS: Menisci with signal possibly contacting the surface had the same frequency of tears (three tears in 33 menisci) as menisci without signal contacting the surface (15 tears in 194 menisci). More than 90% of menisci with signal contacting the surface on more than one image were torn, but only 55% of medial and 30% of lateral menisci with such signal on only one image were torn. In the torn menisci with signal contacting the surface, such signal was seen only on sagittal MR images in 31% of the medial menisci and 45% of the lateral menisci. Sixteen percent of the torn lateral menisci had signal contacting the meniscal surface in only the anterior two thirds of the meniscus, whereas this was true in only 2% of the torn medial menisci. Distinct patterns were not seen in the association between tears and signal contacting either the superior or the inferior surface. CONCLUSION: We found definite patterns in the location of intrameniscal signal that comes in contact with the meniscal surface. These patterns vary in the frequency of associated meniscal tears. Although menisci with internal signal in contact with the surface are usually torn, a tear is less likely if such signal is present on only one image. Tears may be identifiable on only one image plane. Tears in the anterior horn of the lateral meniscus are not uncommon. Knowledge of these patterns should help in the MR diagnosis of meniscal tears.


Asunto(s)
Imagen por Resonancia Magnética , Lesiones de Menisco Tibial , Adolescente , Adulto , Anciano , Niño , Preescolar , Femenino , Humanos , Traumatismos de la Rodilla/diagnóstico , Masculino , Meniscos Tibiales/patología , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Retrospectivos , Sensibilidad y Especificidad
6.
AJR Am J Roentgenol ; 160(3): 555-9, 1993 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-8430552

RESUMEN

OBJECTIVE: A wide range in the efficacy of MR imaging for the diagnosis of meniscal tears of the knee has been reported. To evaluate two possible causes for this variation, we studied how sensitivity and specificity are affected when different observers and sample sizes are used. MATERIALS AND METHODS: Two hundred MR examinations of the knee in patients for whom the results of arthroscopy were available were used for the study. One hundred eight medial meniscal tears and 58 lateral meniscal tears were found at arthroscopy. The sensitivity and specificity for detection of meniscal tears were determined for the original interpretations and retrospective evaluations by three observers. Comparisons were also made between sample sizes of 25 and 100. chi 2 analysis was used for unmatched data sets and McNemar's statistic was used for matched sets. RESULTS: For the 200 examinations, the sensitivity was 0.89-0.93 for medial meniscal tears and 0.79-0.83 for lateral meniscal tears. The specificity was 0.86 for medial meniscal tears and 0.90-0.92 for lateral meniscal tears. Sensitivity and specificity varied widely among different observers and different sample sizes. However, we found no significant difference between any of the comparisons at the p < .05 level. The largest interobserver variation occurred in the detection of lateral meniscal tears, with a sensitivity of 0.71 for one observer and 0.88 for another observer (p = .16). The largest variation between sets of 100 examinations was a change in sensitivity for detection of lateral meniscal tears from 0.74 to 0.88 for the original interpretations (p = .10). For the sample sets of 25 cases, the variation was even larger, with the sensitivity for detection of lateral meniscal tears varying from 0.5 for one set to 1.0 for another. CONCLUSION: We conclude that chance variation related to sample size can cause large but not statistically significant variations in sensitivity and specificity in this setting. These variations are of sufficient magnitude to explain many of the differences in reported sensitivity and specificity for MR imaging in the diagnosis of meniscal tears. We found no significant difference in observer performance.


Asunto(s)
Imagen por Resonancia Magnética , Meniscos Tibiales/patología , Lesiones de Menisco Tibial , Adolescente , Adulto , Anciano , Niño , Preescolar , Femenino , Humanos , Traumatismos de la Rodilla/diagnóstico , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Muestreo , Sensibilidad y Especificidad
8.
Radiology ; 164(3): 867-8, 1987 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-3615889

RESUMEN

Knee arthrography, as performed at the authors' institution, was simulated and scattered radiation exposure to a radiologist's gonads, thyroid, and eye lens was measured with a sensitive ionization chamber. Results show that radiologists who regularly conduct knee arthrography examinations can incur doses to the gonads that are less than 6% of the U.S. limits, and to the thyroid and eye that are approximately 10% of the U.S. limits. Since the scatter radiation from overhead imaging of stress views constituted most (greater than or equal to 60%) of the dose to the lens of the eye and the thyroid, spot imaging was evaluated as a substitute for overhead imaging in the assessment of the anterior cruciate ligament. This substitution resulted in no loss of clinical information and has now completely replaced overhead imaging of stress views at this institution.


Asunto(s)
Artrografía , Articulación de la Rodilla/diagnóstico por imagen , Enfermedades Profesionales/prevención & control , Traumatismos por Radiación/prevención & control , Monitoreo de Radiación , Humanos , Dosis de Radiación , Riesgo , Dispersión de Radiación
9.
J Bone Joint Surg Am ; 69(1): 100-5, 1987 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-3543017

RESUMEN

Fifty patients who had a palpable soft-tissue mass and an apparently normal radiograph were studied with ultrasound imaging before excision or biopsy of the lesion was done. As shown by the sonograms, thirty-five lesions had a discrete echo pattern (usually reduced echoes and a clearly defined lesional margin) and fifteen had an ill defined pattern (similar to the pattern of the surrounding normal tissues with no definable lesional margin). Fourteen lesions were malignant and thirty-six, benign. The sonograms of all fourteen malignant lesions showed a discrete pattern, while the sonograms of the benign ones showed twenty-one discrete and fifteen ill defined patterns. Therefore, the malignant lesions produced a discrete pattern in every instance, and every lesion that produced an ill defined pattern was benign. Fourteen of the fifty lesions were cystic; of these, thirteen were benign and one was malignant. The sonograms correctly identified the cyst in seven of the thirteen benign lesions and in the one malignant cystic lesion. Based on these findings, we concluded that all palpable soft-tissue masses that appear to be discrete on a sonogram should be diagnosed without delay by examination of a specimen taken at biopsy, whereas lesions that have an ill defined appearance on a sonogram may be assumed to be benign and may safely be observed in selected patients.


Asunto(s)
Neoplasias de los Tejidos Blandos/diagnóstico , Ultrasonografía , Algoritmos , Biopsia , Quistes/diagnóstico , Humanos , Neoplasias de los Tejidos Blandos/patología , Neoplasias de los Tejidos Blandos/cirugía
10.
Radiology ; 157(1): 239-41, 1985 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-3898219

RESUMEN

We have developed a method for acquiring multiple tomographic subtraction images using a rapid, repetitive, circular tomographic motion. The method combines the principles of digital subtraction angiography (DSA) and electronic tomosynthesis. Fifteen patients were examined with the technique using single intravenous bolus injections of contrast material. The image sequence obtained during each injection was first processed with a nontomographic mask subtraction, and the result was then compared with the tomographic DSA scans synthesized from the same sequence. The effective section thickness was approximately 0.5 cm, with each section being 0.5-1.0 cm apart. Twelve of the intravenous DSA scans provided the necessary diagnostic or clinically useful information. Two of the three nondiagnostic scans were caused by avoidable technical reasons. In eight cases, the tomographic DSA scans were superior in quality to the nontomographic scans, exhibited significantly less artifact from patient motion and overlying bowel gas, and were effective in separating overlapping vessels. Tomosynthesis permits multiple electronic imaging of the area of interest without reinjection of contrast material and appears to be more informative than nontomographic intravenous DSA imaging.


Asunto(s)
Angiografía/métodos , Técnica de Sustracción , Tomografía por Rayos X , Arterias Carótidas/diagnóstico por imagen , Angiografía Coronaria , Oclusión de Injerto Vascular/diagnóstico por imagen , Humanos , Arteria Renal/diagnóstico por imagen , Tecnología Radiológica
11.
J Comput Assist Tomogr ; 8(6): 1190-1, 1984 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-6501631

RESUMEN

Spontaneous osteoporotic sacral fractures are an uncommon entity. They are difficult to image on plain films. Clinically, they may be confused with metastatic disease. A peculiar H-shaped uptake pattern on bone scan should suggest the condition, and CT can then demonstrate the fracture. In this case this combination of radionuclide scan and CT permitted differentiation of a sacral fracture from presumed bony metastases.


Asunto(s)
Fracturas Espontáneas/diagnóstico por imagen , Osteoporosis/diagnóstico por imagen , Sacro/diagnóstico por imagen , Tomografía Computarizada por Rayos X , Diagnóstico Diferencial , Femenino , Fracturas Espontáneas/etiología , Humanos , Persona de Mediana Edad , Osteoporosis/complicaciones , Cintigrafía , Sacro/lesiones , Neoplasias de la Columna Vertebral/diagnóstico por imagen , Neoplasias de la Columna Vertebral/secundario
12.
J Comput Assist Tomogr ; 7(6): 1112-3, 1983 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-6630649

RESUMEN

A case is reported of a wedge-shaped defect in the anterolateral portion of the femoral head following an anterior dislocation of the obturator type. This hatchet-like defect is similar to the Hill-Sachs defect of the humerus.


Asunto(s)
Cabeza Femoral/lesiones , Luxación de la Cadera/complicaciones , Fracturas de Cadera/etiología , Adulto , Femenino , Cabeza Femoral/diagnóstico por imagen , Luxación de la Cadera/diagnóstico por imagen , Fracturas de Cadera/diagnóstico por imagen , Humanos , Tomografía Computarizada por Rayos X
13.
Radiology ; 149(1): 73-4, 1983 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-6611954

RESUMEN

Obstruction of the inferior vena cava (IVC) was observed as an abdominal mass on the plain radiograph in an asymptomatic patient. The obstruction had developed immediately below the renal veins, and markedly dilated varices were present. The appearance differed from that of the usual congenital caval variants and may have been the result of caval thrombosis in utero.


Asunto(s)
Neoplasias Abdominales/diagnóstico por imagen , Trombosis/diagnóstico por imagen , Vena Cava Inferior/diagnóstico por imagen , Adulto , Diagnóstico Diferencial , Humanos , Masculino , Tomografía Computarizada por Rayos X
14.
Pediatr Radiol ; 12(6): 269-78, 1982.
Artículo en Inglés | MEDLINE | ID: mdl-7162878

RESUMEN

A typical case of congenital generalized fibromatosis (CGF) is presented and the literature on this entity is reviewed. CGF is a rare condition which is probably heritable. It is manifested in infancy. Because of the unusual biological behavior of the fibromata, two clinical courses occur--death, if vital viscera are involved, or regression of the lesions and survival without significant disability. Including the present example, 63 cases have been reported.


Asunto(s)
Neoplasias Óseas/congénito , Fibroma/congénito , Neoplasias Óseas/diagnóstico por imagen , Fibroma/diagnóstico por imagen , Humanos , Lactante , Masculino , Radiografía
15.
Radiology ; 137(2): 543-4, 1980 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-6776588

RESUMEN

Localization of the pancreatic head for biopsy under fluoroscopy was accomplished using carbon dioxide-producing pills. This technique proved useful when other modalities were unsuccessful. Gas can be a useful contrast agent for localization, has no side effects, and causes little interference with further procedures. A case report is presented.


Asunto(s)
Adenocarcinoma/patología , Biopsia con Aguja/métodos , Neoplasias Pancreáticas/patología , Adulto , Anciano , Dióxido de Carbono , Medios de Contraste , Fluoroscopía/métodos , Humanos , Masculino , Persona de Mediana Edad , Neoplasias Pancreáticas/diagnóstico por imagen
SELECCIÓN DE REFERENCIAS