Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Clin Oral Investig ; 28(7): 371, 2024 Jun 13.
Artículo en Inglés | MEDLINE | ID: mdl-38869697

RESUMEN

OBJECTIVES: The purpose of this study is to evaluate the bond strength of different computer-aided design / computer-aided manufacturing (CAD/CAM) hybrid ceramic materials following different pretreatments. METHODS: A total of 306 CAD/CAM hybrid material specimens were manufactured, n = 102 for each material (VarseoSmile Crownplus [VSCP] by 3D-printing; Vita Enamic [VE] and Grandio Blocs [GB] by milling). Each material was randomly divided into six groups regarding different pretreatment strategies: control, silane, sandblasting (50 µm aluminum oxide particles), sandblasting + silane, etching (9% hydrofluorics acid), etching + silane. Subsequently, surface roughness (Ra) values, surface free energy (SFE) were measured. Each specimen was bonded with a dual-cured adhesive composite. Half of the specimens were subjected to thermocycling (5000 cycles, 5-55 °C). The shear bond strength (SBS) test was performed. Data were analyzed by using a two-way analysis of variance, independent t-test, and Mann-Whitney-U-test (α = 0.05). RESULTS: Material type (p = 0.001), pretreatment strategy (p < 0.001), and the interaction (p < 0.001) all had significant effects on Ra value. However, only etching on VSCP and VE surface increased SFE value significantly. Regarding SBS value, no significant difference was found among the three materials (p = 0.937), while the pretreatment strategy significantly influenced SBS (p < 0.05). Etching on VSCP specimens showed the lowest mean value among all groups, while sandblasting and silane result in higher SBS for all test materials. CONCLUSIONS: The bond strength of CAD/CAM hybrid ceramic materials for milling and 3D-printing was comparable. Sandblasting and silane coupling were suitable for both millable and printable materials, while hydrofluoric etching should not be recommended for CAD/CAM hybrid ceramic materials. CLINICAL RELEVANCE: Since comparable evidence between 3D-printable and millable CAD/CAM dental hybrid materials is scarce, the present study gives clear guidance for pretreatment planning on different materials.


Asunto(s)
Diseño Asistido por Computadora , Coronas , Recubrimiento Dental Adhesivo , Análisis del Estrés Dental , Ensayo de Materiales , Resistencia al Corte , Propiedades de Superficie , Recubrimiento Dental Adhesivo/métodos , Cerámica/química , Silanos/química , Materiales Dentales/química , Grabado Dental/métodos , Porcelana Dental/química , Técnicas In Vitro , Humanos
2.
Dent Mater ; 40(8): 1123-1127, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38824001

RESUMEN

OBJECTIVE: Achieving a strong bond between Polyetheretherketone (PEEK) and veneering composites is challenging due to PEEKs low surface energy. This study examined the effects of sandblasting and bonding on the shear bond strength (SBS) between veneering composite and pigmented PEEK, considering artificial aging. METHODS: Of three pigmented PEEK compounds (DC4420R, DC4450R, DC4470R; Evonic Operations GmbH, Marl, Germany), 40 specimens each were milled and polished up to 2500 grit. Prior to veneering, specimens were divided into 4 subgroups: Subgroup 1: Polishing; 2: Polishing + bonding; 3: Sandblasting; 4: Sandblasting + bonding. Sandblasting was performed using Al2O3. Adhesive was an agent containing MMA (Signum Universal Bond, Kulzer GmbH, Hanau, Germany). After veneering (Composite, Kulzer GmbH) the subgroups were divided into 2 subgroups. One subgroup was immersed in 37 °C warm distilled water for 24 h. The second subgroup was artificially aged by thermocycling (TCL) with 5000 cycles in distilled water (5 °C / 55 °C; 30 s). Surface roughness, water contact angles and failure modes were recorded. SBS was measured using a universal testing machine. RESULTS: Results demonstrated that the combination of sandblasting and bonding significantly improved the SBS compared to polishing alone. PEEK color did not significantly influence the SBS. Aging by TCL had a negative effect on the SBS. SIGNIFICANCE: Sandblasting and the use of an adhesive containing MMA were found to be effective in achieving satisfactory SBS between veneering composite and pigmented PEEK surfaces. These pretreatment methods demonstrate their potential for establishing durable and reliable bonding in clinical applications.


Asunto(s)
Benzofenonas , Resinas Compuestas , Recubrimiento Dental Adhesivo , Análisis del Estrés Dental , Coronas con Frente Estético , Cetonas , Ensayo de Materiales , Polietilenglicoles , Polímeros , Resistencia al Corte , Propiedades de Superficie , Cetonas/química , Resinas Compuestas/química , Polímeros/química , Polietilenglicoles/química , Pulido Dental , Grabado Dental/métodos , Óxido de Aluminio/química , Color
3.
Dent Mater ; 40(6): 930-940, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38724334

RESUMEN

OBJECTIVES: An increasing number of CAD/CAM (computer-aided design/computer-aided manufacturing) hybrid materials have been introduced to the dental market in recent years. In addition, CAD/CAM hybrid materials for additive manufacturing (AM) are becoming more attractive in digital dentistry. Studies on material microstructures using micro-computed tomography (µ-CT) combined with scanning electron microscopy (SEM) have only been available to a limited extent so far. METHODS: One CAD/CAM three-dimensional- (3D-) printable hybrid material (VarseoSmile Crown plus) and two CAD/CAM millable hybrid materials (Vita Enamic; Voco Grandio), as well as one direct composite material (Ceram.x duo), were included in the present study. Cylindrical samples with a diameter of 2 mm were produced from each material and investigated by means of synchrotron radiation µ-CT at a voxel size of 0.65 µm. Different samples from the same materials, obtained by cutting and polishing, were investigated by SEM. RESULTS: The 3D-printed hybrid material showed some agglomerations and a more irregular distribution of fillers, as well as a visible layered macrostructure and a few spherical pores due to the printing process. The CAD/CAM millable hybrid materials revealed a more homogenous distribution of ceramic particles. The direct composite material showed multiple air bubbles and microstructural irregularities based on manual processing. SIGNIFICANCE: The µ-CT and SEM analysis of the materials revealed different microstructures even though they belong to the same class of materials. It could be shown that µ-CT and SEM imaging are valuable tools to understand microstructure and related mechanical properties of materials.


Asunto(s)
Diseño Asistido por Computadora , Materiales Dentales , Ensayo de Materiales , Microscopía Electrónica de Rastreo , Propiedades de Superficie , Microtomografía por Rayos X , Materiales Dentales/química , Resinas Compuestas/química , Impresión Tridimensional , Cerámica/química
4.
Materials (Basel) ; 16(23)2023 Nov 24.
Artículo en Inglés | MEDLINE | ID: mdl-38068054

RESUMEN

The aim of this study was to compare the potential of standard ion-releasing materials to repair demineralized lesions with recently introduced alkasite and glass hybrid materials. Glass ionomer (GC Fuji TRIAGE), two glass hybrids (EQUIA Forte HT, Riva SC), calcium silicate cement (Biodentine) and an alkasite (Cention Forte) were tested. A total of 72 human third molars were used for sample preparation; on the dentine surface, a class-I cavity was prepared, and one half was covered with nail varnish. The teeth were subjected to a demineralization protocol, filled with the examined materials, and cut in half. The evaluation included a dentine microhardness assessment (n = 10) and SEM/EDS analysis (n = 2). The results were analyzed using SPSS 22.0 statistical software and compared using an analysis of variance and Scheffe post-hoc test. The statistical significance level was set to 0.05. Mean microhardness values (HV0.1) after 14 and 28 days were, respectively: EQUIA Forte HT (26.7 ± 1.45 and 37.74 ± 1.56), Riva Self Cure (19.66 ± 1.02 and 29.58 ± 1.18), Cention Forte (19.01 ± 1.24 and 27.93 ± 1.33), Biodentine (23.35 ± 1.23 and 29.92 ± 1.02), GC Fuji TRIAGE (25.94 ± 1.35 and 33.87 ± 5.57) and control group (15.57 ± 0.68 and 15.64 ± 0.82). The results were significantly different between most groups (p < 0.001). SEM/EDS revealed varying patterns, material deposits and distinct elemental variations. To conclude, all materials increased microhardness and affected the dentine surface appearance and chemical composition; EQUIA Forte HT demonstrated the most pronounced effects.

5.
Int J Implant Dent ; 9(1): 34, 2023 09 21.
Artículo en Inglés | MEDLINE | ID: mdl-37733145

RESUMEN

PURPOSE: This systematic review aimed to evaluate the incidence of microleakage events (IME) and to identify the potential factors influencing the sealing ability of the implant-abutment interface (IAI) under in vitro investigation. MATERIAL AND METHODS: An electronic search of MEDLINE (PubMed), EMBASE, and Web of Science databases, combined with a manual literature search was conducted up to September 2022. In vitro studies that reported the degree of microleakage at IAI under dynamic loading conditions were included. A meta-analysis was performed to calculate the mean values of the incidence of microleakage events. Subgroup analysis and meta-regression were conducted to further investigate the effect of different variables. RESULTS: 675 studies were identified following the search process and 17 in vitro studies were selected according to the eligibility criteria. The weighted mean incidence of microleakage events was 47% (95% confidence interval: [0.33, 0.60]), indicating that contamination was observed in nearly half of the samples. Concerning possible factors that may influence microleakage (e.g., loading condition, assessment method, implant-abutment connection design, types of abutment material, the use of sealing agents), loading condition (p = 0.016) was the only variable that significantly influenced IME in the meta-regression analysis. CONCLUSIONS: The results demonstrated that dynamic loading significantly increases the potential of bacterial penetration at the implant-abutment junction. The results should be interpreted carefully due to the data heterogeneity and further well-conducted in vitro studies with homogeneous samples are needed to standardize the methodologies.


Asunto(s)
Implantes Dentales , Bases de Datos Factuales , Contaminación de Medicamentos , Electrónica , Determinación de la Elegibilidad
6.
J Prosthodont Res ; 67(4): 562-567, 2023 Oct 13.
Artículo en Inglés | MEDLINE | ID: mdl-36804247

RESUMEN

PURPOSE: To investigate the effects of printing-layer thickness and build angle on the surface characteristics and microbial adhesion of denture base polymers manufactured by digital light processing (DLP). METHODS: Specimens were additively manufactured using DLP. The specimens were printed with different printing-layer thicknesses (25, 50, and 100 µm) and build angles (0°, 45°, and 90°). Scanning electron microscopy was used to observe the surface topography, and the arithmetical mean heights (Sa) were measured. Moreover, the initial Candida albicans (C. albicans) adhesion to the specimens was evaluated using an adhesion test. Finally, two-way ANOVA and Tukey's multiple comparison tests were conducted. RESULTS: The results regarding the Sa values exhibited a statistically significant interaction (F (4, 45) = 90.77, P < 0.0001). The build angle has a significant impact on the surface topography. Furthermore, quantitative results revealed that the printing-layer thickness significantly affected C. albicans adhesion (F (2, 99) = 6.96, P = 0.0015). CONCLUSIONS: The surface roughness was significantly affected by the printing-layer thickness and the build angle. Additionally, the surface topography was mainly determined by the build angle. Furthermore, the adhesion of C. albicans to the DLP-printed denture surfaces was significantly affected by the printing-layer thickness but not by the build angle. Consequently, it is critical to decrease the thickness of the printing layer to produce digital dentures with optimal material properties.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...