Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Int J Radiat Oncol Biol Phys ; 48(2): 501-5, 2000 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-10974468

RESUMEN

BACKGROUND: This study is to report the clinical experiences of fractionated stereotactic radiation therapy (FSRT) for extracranial head and neck tumors. METHODS AND MATERIALS: Between the period of July 1995 and November 1998, 48 patients with extracranial head and neck tumors were given FSRT as a boost and sole modality. Individualized treatment planning was performed using XKnife-3 system with relocatable Gill-Thomas-Cosman frame. In 24 patients, FSRT was applied as a boost technique following the 2-dimensional conventional external radiation therapy (ERT); in 24 patients FSRT was the sole radiotherapy modality. The primary diseases in the boost group consisted of nasopharynx cancer (19), lacrimal gland adenoid cystic carcinoma (3), orbital lymphoma (1), and skull-base recurrence of maxillary sinus adenoid cystic carcinoma (1). The primary diseases in the sole modality group consisted of recurrent nasopharynx cancer (12), orbital pseudotumor (4), skull-base recurrence of maxillary sinus, submandibular gland, and hypopharynx cancers (3), orbital rhabdomyosarcoma (2), orbital lymphoma (1), orbital metastasis of neuroblastoma (1), and nasal cavity melanoma (1). The fractionation schedule was to give 5 treatments per one week and the fractional doses were 2.0-3 Gy depending on the treatment aim and the FSRT volume. The FSRT doses varied depending on the nature of the primary diseases. RESULTS: The local tumor response in nasopharynx cancer patients was excellent compared to retrospective data without occurrence of unexpectedly severe complication. FSRT to other regions was well tolerated by the patients and resulted in good to excellent local tumor responses with no unacceptable side effects as expected by the authors. CONCLUSION: Based on the current observations, FSRT is a very effective and safe modality in the treatment of extracranial head and neck tumors.


Asunto(s)
Neoplasias de Cabeza y Cuello/cirugía , Radiocirugia/métodos , Carcinoma Adenoide Quístico/diagnóstico por imagen , Carcinoma Adenoide Quístico/cirugía , Fraccionamiento de la Dosis de Radiación , Estudios de Seguimiento , Neoplasias de Cabeza y Cuello/diagnóstico por imagen , Humanos , Enfermedades del Aparato Lagrimal/diagnóstico por imagen , Enfermedades del Aparato Lagrimal/cirugía , Linfoma/diagnóstico por imagen , Linfoma/cirugía , Neoplasias Nasofaríngeas/diagnóstico por imagen , Neoplasias Nasofaríngeas/cirugía , Neoplasias Orbitales/diagnóstico por imagen , Neoplasias Orbitales/cirugía , Planificación de la Radioterapia Asistida por Computador , Neoplasias de la Base del Cráneo/diagnóstico por imagen , Neoplasias de la Base del Cráneo/secundario , Neoplasias de la Base del Cráneo/cirugía , Análisis de Supervivencia , Tomografía Computarizada por Rayos X
2.
Int J Radiat Oncol Biol Phys ; 48(2): 541-4, 2000 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-10974474

RESUMEN

PURPOSE: A new collimator cone system has been developed at the Samsung Medical Center that overcomes some of the limitations of present commercially supplied collimator cones. The physical properties of the newly developed cone system are described in this report. METHODS AND MATERIALS: The new cones have relatively larger aperture sizes (3.0-7.0 cm in diameter) and are 16 cm in length. Each new cone is fabricated with cerrobend alloy melted and poured into a stainless steel housing that is permanently fixed to a mounting plate. The mounting plate of the new cone is designed to insert into the wedge mount slot of the gantry head. The mechanical accuracy of the central axis of the cone pointing to the isocenter was tested using film, a steel ball positioned at the isocenter by the mechanical isocenter device. For the evaluation of beam flatness and penumbra, off-axis ratios at 5 cm depth were measured by film dosimetry using polystyrene phantom. RESULTS: The average error of the mechanical isocenter was 0.27 mm (+/- 0.16 mm). The beam flatness was excellent in the central region of the beam, and the average penumbra width was 3.35 mm (+/- 0.25 mm). The new cone design has more clearance between the patient's head and the gantry, and can more easily be removed from the gantry head because it slides in and out of the wedge slot. This facilitates changing cone sizes during one treatment session, and makes the process of double exposure port films easier. CONCLUSIONS: A new collimator cone system for stereotactic radiation therapy has been developed. The mechanical accuracy and physical properties are satisfactory for clinical use, and the new design permits a wider range of clinical applications for stereotactic radiation therapy.


Asunto(s)
Radiocirugia/instrumentación , Aleaciones , Diseño de Equipo , Estudios de Evaluación como Asunto , Física Sanitaria
3.
J Food Prot ; 63(12): 1707-12, 2000 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-11131895

RESUMEN

Strain BH5 was isolated from naturally fermented Kimchi and identified as a bacteriocin producer that has bactericidal activity against Micrococcus flavus ATCC 10240. Strain BH5 was identified tentatively as Lactococcus lactis by API test. Lactococcus lactis BH5 showed a broad spectrum of activity against most of the nonpathogenic and pathogenic microorganisms tested by the modified deferred method. The activity of lacticin BH5, named tentatively as the bacteriocin produced by L. lactis BH5, was detected at the mid-log growth phase, reached its maximum during the early stationary phase, and decreased after the late stationary phase. Lacticin BH5 also showed a relatively broad spectrum of activity against nonpathogenic and pathogenic microorganisms as tested by the spot-on-lawn method. Its antimicrobial activity on sensitive indicator cells was completely destroyed by protease XIV. The inhibitory activities of lacticin BH5 were detected during treatments up to 100 degrees C for 30 min. Lacticin BH5 was very stable over a pH range of 2.0 to 9.0 and was stable with all the organic solvents examined. It demonstrated a typical bactericidal mode of inhibition against M. flavus ATCC 10240. The apparent molecular mass of lacticin BH5 was estimated to be in the region of 3 to 3.5 kDa, by the direct detection of bactericidal activity after sodium dodecyl sulfate-polyacrylamide gel electrophoresis.


Asunto(s)
Proteínas Bacterianas/aislamiento & purificación , Bacteriocinas/aislamiento & purificación , Lactococcus lactis/metabolismo , Proteínas Bacterianas/biosíntesis , Proteínas Bacterianas/farmacología , Bacteriocinas/biosíntesis , Bacteriocinas/farmacología , Brassica/microbiología , Electroforesis en Gel de Poliacrilamida , Fermentación , Microbiología de Alimentos , Conservación de Alimentos , Calor , Concentración de Iones de Hidrógeno , Lactococcus lactis/clasificación , Microscopía Electrónica de Rastreo , Peso Molecular , Factores de Tiempo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...