Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 118
Filtrar
1.
Int J Surg ; 2024 Jul 02.
Artículo en Inglés | MEDLINE | ID: mdl-38954673

RESUMEN

BACKGROUND: Normothermic iliac perfusion has been increasingly utilized for TAAA repair; however, the long-term outcomes in large samples are lacking. This study was designed to assesses the perioperative and long-term results of thoracoabdominal aortic repair using normothermic iliac perfusion. METHODS: We retrospectively analyzed 156 patients having Crawford extent II or III thoracoabdominal aortic aneurysm replacement with normothermic iliac perfusion from 2012 to 2022. Primary endpoints were composite adverse events and long-term survival, which encompassed 30-day mortality, persistent stroke, persistent paraplegia, and acute renal failure needing continuous dialysis. The cohort was divided into two subgroups based on the use of selective visceral and cold renal perfusion techniques. RESULTS: The combined adverse event rate was 14.1%. Specific rates were: 30-day mortality (4.5%), persistent stroke (1.9%), persistent paraplegia (4.5%), and renal failure requiring persistent dialysis (3.2%). The median follow-up time was 67 months. Overall survival rates at 1, 3, 5, 7, and 10 years were 91.6%, 90.0%, 85.4%, 77.6%, and 69.7%, respectively. Subgroup analysis showed the visceral and renal perfusion group had a significantly reduced adverse event incidence compared to the nonperfusion group (6.5% vs. 19.1%, P=0.026). Multivariable logistic regression analysis confirmed selective visceral and cold renal perfusion techniques as protective factors against postoperative adverse events (OR 0.30, 95%CI 0.09-0.94; P=0.038). Multivariable Cox regression analysis identified age ≥50 years (HR 2.63, 95%CI 1.10-6.27; P=0.029) and NYHA grade ≥III (HR: 3.20, 95% CI: 1.04-9.87; P=0.043) as independent risk factors predicting overall survival. CONCLUSIONS: Normothermic iliac perfusion is a feasible option for thoracoabdominal aortic repair with cost benefits and simpler management, and selective visceral and cold renal perfusion techniques may further improve its safety and effectiveness. However, enhanced vigilance and meticulous care are essential, particularly for elderly patients and those with cardiac insufficiency.

2.
J Cardiothorac Surg ; 19(1): 379, 2024 Jun 26.
Artículo en Inglés | MEDLINE | ID: mdl-38926836

RESUMEN

BACKGROUND: For acute type A aortic dissection involving the aortic root with root diameter no more than 45 mm, there are various aortic root repair techniques. In this study, a novel surgical technique using a pericardial autograft for aortic root repair was introduced. We described its surgical steps in detail and compare its clinical outcomes with direct suture technique. METHODS: Between July 2017 and August 2022, 95 patients with acute type A aortic dissection who underwent aortic root repair were enrolled, including aortic root repair using pericardial autograft (group A, n = 49) or direct suture (group B, n = 46). The patient's clinical data were retrospectively analyzed, and a 5-year follow-up was conducted. RESULTS: The 30-day mortality, re-exploration for bleeding, postoperative new-onset renal failure requiring continuous renal replacement therapy, stroke, and paraplegia occurred in 3%, 4%, 11%, 5%, and 2% of the overall patients, respectively. There was no significant difference in the 30-day mortality and complication rate between the two groups. The 30-day mortality and re-exploration for bleeding marked the primary endpoint events. Logistic regression analysis indicated that there was a significant correlation between the primary endpoint events and surgical technique (odds ratio, 0.002; 95% confidence interval, 0-0.159; P = 0.026). The aortic valve insufficiency of the two groups were significantly improved after operation (group A, P < 0.001; group B, P < 0.001). During follow-up, there was no significant difference in short-term survival between the two groups after surgery (log-rank P = 0.75), and all patients were free from reoperation for aortic disease. CONCLUSIONS: Patients who underwent aortic root repair using pericardial autograft tended to have reduced 30-day mortality and a lower risk of re-exploration for bleeding. Using pericardial autograft for aortic root repair is a safe and useful approach for patients with acute type A aortic dissection involving the aortic root.


Asunto(s)
Disección Aórtica , Pericardio , Humanos , Disección Aórtica/cirugía , Masculino , Femenino , Estudios Retrospectivos , Persona de Mediana Edad , Pericardio/trasplante , Resultado del Tratamiento , Autoinjertos , Aneurisma de la Aorta Torácica/cirugía , Anciano , Enfermedad Aguda , Complicaciones Posoperatorias , Implantación de Prótesis Vascular/métodos , Trasplante Autólogo , Estudios de Seguimiento
3.
Heliyon ; 10(9): e30323, 2024 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-38711632

RESUMEN

Background: Prolonged circulatory arrest time is an independent risk factor for postoperative adverse events of type A aortic dissection (TAAD) surgery. Further reduction of the circulatory arrest time is essential to improve surgical outcomes. This study aimed to evaluate the safety and effectiveness of the novel Sutureless Integrated Stented (SIS) graft prosthesis in an animal experiment. Materials and methods: Straight type of the SIS graft prosthesis was implanted into the descending aorta of 10 adult male sheep, and the use of the device was scored on a scale of 1-10. Aortic digital subtraction angiography (DSA) was performed at 4, 14, and 26 weeks to investigate the prostheses. After 26 weeks, the animals were sacrificed for histological analysis. Results: The immediate success rate of the surgery was 100 %, and the overall mean score of the use of the device was 9.65 ± 0.99. Three animals died from non-device-related causes during follow-up. Aortic DSA showed filling defects in 5 animals. Histological analysis revealed that all prostheses were intact. Except for 2 early deaths, the other 8 prostheses were endothelialized with mild inflammation, foreign body reactions, and intimal fibrosis. The mean cross-sectional area of the sutureless region was reduced by 26.4 % (range, 1.3-39.1 %). Conclusions: The safety and effectiveness of the novel SIS graft prosthesis were acceptable, and the delivery system exhibited a promising performance. Using the SIS graft prosthesis in TAAD surgery was expected to simplify the procedures and shorten the circulatory arrest time. Further large-scale clinical trials are required to verify these findings.

4.
Lab Invest ; 104(3): 100326, 2024 03.
Artículo en Inglés | MEDLINE | ID: mdl-38237739

RESUMEN

To better understand the pathogenesis of acute type A aortic dissection, high-sensitivity liquid chromatography-tandem mass spectrometry/mass spectrometry (LC-MS/MS)-based proteomics and phosphoproteomics approaches were used to identify differential proteins. Heat shock protein family B (small) member 6 (HSPB6) in aortic dissection was significantly reduced in human and mouse aortic dissection samples by real-time PCR, western blotting, and immunohistochemical staining techniques. Using an HSPB6-knockout mouse, we investigated the potential role of HSPB6 in ß-aminopropionitrile monofumarate-induced aortic dissection. We found increased mortality and increased probability of ascending aortic dissection after HSPB6 knockout compared with wild-type mice. Mechanistically, our data suggest that HSPB6 deletion promoted vascular smooth muscle cell apoptosis. More importantly, HSPB6 deletion attenuated cofilin activity, leading to excessive smooth muscle cell stiffness and eventually resulting in the development of aortic dissection and rupture. Our data suggest that excessive stiffness of vascular smooth muscle cells caused by HSPB6 deficiency is a new pathogenetic mechanism leading to aortic dissection.


Asunto(s)
Disección Aórtica , Espectrometría de Masas en Tándem , Ratones , Humanos , Animales , Cromatografía Liquida , Disección Aórtica/genética , Miocitos del Músculo Liso/metabolismo , Ratones Noqueados , Modelos Animales de Enfermedad , Proteínas del Choque Térmico HSP20/metabolismo
5.
BMC Cardiovasc Disord ; 23(1): 313, 2023 06 21.
Artículo en Inglés | MEDLINE | ID: mdl-37344803

RESUMEN

BACKGROUND: To introduce a new and simple classification and management of coronary artery involvement in aortic dissection and report results. METHODS: Coronary artery involvement was classified into two types according to the integrity of coronary intima: simple lesion (type S) and complex lesion (type C). Complex lesions were treated by CABG and simple lesions were treated by ostial repair or reimplantation. Data were collected and analyzed retrospectively. RESULTS: From January 2010 to December 2019, 267 consecutive patients were enrolled in the study, and among them complex lesions occurred in 27 patients (11.1%) and simple lesions was found in 240 patients(89.9%). Eleven untreated vessels with simple lesion were found to be involved again in the same operation and treated by CABG. The two type groups had comparable operative mortality (type S vs. type C, 9.6% vs. 18.5%, P = 0.28). 221 patients received follow-up with a median duration of 52 months. The overall survival rates at 1, 5, and 10 years postoperatively were 88.9%, 85.7%, and 79.8% in type S group and 79.2%, 79.2%, and 79.2% in type C group, respectively (P = 0.47). For the patients who received CABG and survived at discharge, radiographic follow-up with a median duration of 28 (IQR 7-55.5) months showed the freedom from occlusion of vein graft at 1, 5, and 10 years postoperatively were 87.5%, 70.0%, 28.0%. CONCLUSIONS: According to the new classification, two types of lesions could be treated by corresponding methods with satisfactory early and long-term results. Unrepaired coronary artery was at a risk of re-involvement. Vein graft onto arteries without atherosclerosis still had a high occlusion rate.


Asunto(s)
Disección Aórtica , Vasos Coronarios , Humanos , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/cirugía , Puente de Arteria Coronaria , Estudios Retrospectivos , Disección Aórtica/diagnóstico por imagen , Disección Aórtica/cirugía , Resultado del Tratamiento
6.
Biochem Biophys Res Commun ; 665: 124-132, 2023 07 12.
Artículo en Inglés | MEDLINE | ID: mdl-37156050

RESUMEN

Fibrillin 1 (Fbn1) mutations cause Marfan syndrome (MFS), with aortic root dilatation, dissection, and rupture. Few studies reported the blood calcium and lipid profile of MFS, and the effect of vascular smooth muscle cell (VSMC) phenotypic switching on MFS aortic aneurysm is unclear. Here, we aimed to investigate the role of calcium-related VSMC phenotypic switching in MFS. We retrospectively collected MFS patients' clinical data, performed bioinformatics analysis to screen the enriched biological process in MFS patients and mice, and detected markers of VSMC phenotypic switching on Fbn1C1039G/+ mice and primary aortic vascular smooth muscle cells. We found that patients with MFS have elevated blood calcium levels and dyslipidemia. Furthermore, the calcium concentration levels were increased with age in MFS mice, accompanied by the promoted VSMC phenotypic switching, and SERCA2 contributed to maintaining the contractile phenotype of VSMCs. This study provides the first evidence that the increased calcium is associated with the promoted VSMC phenotype switching in MFS. SERCA may become a novel therapeutic target for suppressing aneurysm progression in MFS.


Asunto(s)
Síndrome de Marfan , Músculo Liso Vascular , Ratones , Animales , Calcio , Síndrome de Marfan/genética , Síndrome de Marfan/complicaciones , Estudios Retrospectivos , Fenotipo , Miocitos del Músculo Liso
7.
Semin Thorac Cardiovasc Surg ; 35(2): 311-321, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-35276357

RESUMEN

This study sought to identify the midterm outcomes of one-stage hybrid aortic arch repair (HAAR) in patients with Stanford type A aortic dissection (TAAD). Between January 2010 and December 2015, 75 consecutive patients with TAAD involving the aortic arch who underwent one-stage type Ⅱ HAAR at our institution were identified. During this period, 496 consecutive patients with TAAD underwent traditional total aortic arch replacement (TAR) with frozen elephant trunk. The preoperative, perioperative, and postoperative data of all patients were compared. A propensity score-matching analysis was applied to adjust for baseline risk factors. Five hundred and seventy-one patients were included for analysis (428 men; mean age, 48.9 ± 11.1 years). For all patients, the mean follow-up time was 41.1 ± 22.1 months, in-hospital mortality was 4.7%, and the 5-year survival rate was 89.5%. Midterm outcomes between the propensity-matched groups were compared (59 HAAR vs TAR pairs). HAAR group showed shorter cardiopulmonary bypass time (105-159 minutes vs 158-230 minutes, P < 0.001), aortic cross-clamping time, postoperative ventilation time, and intensive care unit stays (33-108 hours vs 45-131 hours, P = 0.010) than the TAR group. There were no significant differences in in-hospital mortality, rate of stroke and rate of paraplegia between the 2 groups, however, better 5-year survival rate was found in HAAR group (94.9% vs 75.8%, Log-rank P = 0.005). As compared to propensity matched cohort of TAR patients, HAAR shows good midterm outcomes for patients with TAAD. Further randomized study was needed to clarify the optimal management strategy of TAAD.


Asunto(s)
Aneurisma de la Aorta Torácica , Disección Aórtica , Implantación de Prótesis Vascular , Adulto , Humanos , Masculino , Persona de Mediana Edad , Aorta/cirugía , Aorta Torácica/diagnóstico por imagen , Aorta Torácica/cirugía , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/cirugía , Aneurisma de la Aorta Torácica/etiología , Disección Aórtica/diagnóstico por imagen , Disección Aórtica/cirugía , Implantación de Prótesis Vascular/efectos adversos , Estudios Retrospectivos , Resultado del Tratamiento
8.
Perfusion ; 38(7): 1384-1392, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-35786218

RESUMEN

BACKGROUND: Glucocorticoids (GC)were applied in total aortic arch replacement (TAAR) at various dosages in many centers, but with limited evidence. METHODS: The retrospective study was aimed to evaluate whether methylprednisolone was associated with better postoperative outcomes in patients undergoing TAAR. Patients undergoing TAAR with moderate hypothermia and selective cerebral perfusion between 2017.1 to 2018.12 in Fuwai hospital were classified into three groups according to doses of methylprednisolone given in the surgery: large-GC group (1500-3000 mg); medium-GC group (500-1000 mg) and no-GC group (0 mg). Postoperative outcomes were compared among three groups. Multivariable analysis was performed to identify the association of methylprednisolone with outcomes. RESULTS: Three hundred twenty-eight patients were enrolled. Two hundred twenty-eight were in the large-GC group, 34 were in the medium-GC group, and 66 were in the no-GC group. The incidences of major adverse outcomes in large-GC, medium-GC and no-GC groups were 22.8%, 17.6% and 18.2%, respectively, with no statistical difference. A significant difference was observed in post-cardiopulmonary bypass (CPB) fresh frozen plasma (FFP) transfusion (p < .001) and chest drainage volume (p < .001). Multivariable analysis demonstrated that methylprednisolone was not associated with better outcomes (p = .455), while large doses of methylprednisolone were significantly associated with excessive chest drainage (over 2000 mL) [OR (99% CI) 4.282 (1.66-11.044), p < .001] and excessive post-CPB FFP transfusion (over 400 mL) [OR (99% CI) 2.208 (1.027-4.747), p = .008]. CONCLUSIONS: Large doses of methylprednisolone (1500-3000 mg) did not show a protective effect in TAAR with moderate hypothermia arrest plus selective cerebral perfusion and might increase postoperative bleeding and FFP transfusion.


Asunto(s)
Hipotermia Inducida , Hipotermia , Humanos , Aorta Torácica/cirugía , Metilprednisolona/uso terapéutico , Estudios Retrospectivos , Hipotermia/etiología , Perfusión/efectos adversos , Paro Circulatorio Inducido por Hipotermia Profunda/efectos adversos , Circulación Cerebrovascular , Hipotermia Inducida/efectos adversos , Resultado del Tratamiento
9.
J Card Surg ; 37(12): 4841-4849, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36352779

RESUMEN

OBJECTIVE: Optimal hypothermia strategy for total arch replacement in acute type A aortic dissection (ATAAD) is unclear. A higher temperature during circulatory arrest might reduce tolerance to ischemia for visceral organs. We sought to investigate the effect of hypothermia on visceral protection. METHODS: From January 2010 to December 2019, 1138 consecutive patients underwent total arch replacement combined with frozen elephant trunk for acute type A aortic dissection. The data were retrospectively collected and analyzed. Visceral organ injury and visceral-related adverse outcomes were defined as acute renal failure or spinal cord injury or both. Multivariate logistic regression analysis and multivariate linear regression model were used. RESULTS: The mean age of patient was 46.9 ± 10.0 years, with a male preponderance (79.6%). Operative mortality was 6.1% (69 patients). Spinal cord injury occurred in 55 (4.8%) patients and 133 (11.7%) patients had acute renal failure. In the multivariate logistic regression model, neither bladder temperature (odds ratio [OR] 0.971, 95% confidence interval [CI] 0.922-1.024, p = .278) nor circulatory arrest duration (OR 1.017, 95% CI 0.987-1.047, p = .267) significantly associated with visceral-related adverse outcomes. Female, lower limb malperfusion, age, cardiopulmonary bypass (CPB) duration and preoperative serum creatinine level were independent risk factors of visceral-related outcomes. There was a significant negative correlation between bladder temperature and CPB duration in multiple linear regression model (ß = -3.67, p < .0001). CONCLUSIONS: Bladder temperature had no effect on outcomes related to visceral protection under the premise of short circulatory arrest duration, but female gender, lower limb malperfusion, age, CPB duration, and preoperative serum creatinine level were independent risk factors. Bladder temperature negatively correlated to CPB duration.


Asunto(s)
Lesión Renal Aguda , Aneurisma de la Aorta Torácica , Disección Aórtica , Implantación de Prótesis Vascular , Hipotermia , Traumatismos de la Médula Espinal , Humanos , Masculino , Femenino , Adulto , Persona de Mediana Edad , Aorta Torácica/cirugía , Hipotermia/complicaciones , Hipotermia/cirugía , Estudios Retrospectivos , Creatinina , Implantación de Prótesis Vascular/efectos adversos , Resultado del Tratamiento , Disección Aórtica/cirugía , Factores de Riesgo , Traumatismos de la Médula Espinal/complicaciones , Traumatismos de la Médula Espinal/cirugía , Lesión Renal Aguda/epidemiología , Lesión Renal Aguda/etiología , Lesión Renal Aguda/prevención & control , Aneurisma de la Aorta Torácica/cirugía , Aneurisma de la Aorta Torácica/complicaciones
10.
BMC Cardiovasc Disord ; 22(1): 302, 2022 07 03.
Artículo en Inglés | MEDLINE | ID: mdl-35786318

RESUMEN

OBJECTIVE: One-staged surgical treatment of aortic coarctation combined with cardiac anomalies is challenging. We aim to evaluate the feasibility of bilateral aortofemoral bypass technique in one-staged surgery treating coractation by comparing surgical outcomes with catheter intervention plus stent (hybrid). METHODS: Between January 2012 and December 2017, 50 patients underwent one-staged surgical procedures to treat coarctation and repair concomitant cardiac anomalies, like aortic root dilatation, cardiac valvular disease and so on. Among them, 30 patients underwent bilateral aortofemoral bypass and 20 patients underwent hybrid procedure to treat coarctation. We retrospectively analyzed the data of these patients and compared the early and late results. RESULTS: All the baseline clinical characteristics were comparable between groups except that the mean age of bypass group was 39.5 ± 14.0 years which was older than hybrid group (27.9 ± 8.5 years, P = 0.002). Technical success was achieved in all patients, with no hospital death or other severe complications. Immediately after surgery, in bypass and hybrid group, the mean upper-limb systolic blood pressure decreased from 159.4 to 119.7 mmHg and 148.4 to 111.6 mmHg, the median peak systolic gradient decreased from 68.0 to 10 mmHg and 46.5 to 10 mmHg respectively (P = 0.09). And the mean upper-lower limbs gradient decreased from 21.7 to 5.9 mmHg and 21.0 to 2.7 mmHg respectively (P = 0.104). The mean follow-up time was 76.92 ± 18.7 in bypass group and 85.4 ± 20.6 months in hybrid group. There were 4 late deaths in bypass group (one died of gastrointestinal bleeding, one died of pulmonary embolism and the other two died of heart failure caused by mechanical prosthetic valve dysfunction). The follow-up peak systolic gradient and other blood pressure parameters showed stable and no differences between two groups. CONCLUSIONS: The bilateral aortofemoral bypass surgery is a safe and effective method which can be used in one-staged surgical strategy to treat coarctation complicated by cardiac anomalies and can be an alternative to the hybrid method.


Asunto(s)
Coartación Aórtica , Implantación de Prótesis Vascular , Enfermedades de las Válvulas Cardíacas , Adulto , Aorta Abdominal , Coartación Aórtica/complicaciones , Coartación Aórtica/diagnóstico por imagen , Coartación Aórtica/cirugía , Implantación de Prótesis Vascular/efectos adversos , Enfermedades de las Válvulas Cardíacas/cirugía , Humanos , Persona de Mediana Edad , Estudios Retrospectivos
11.
J Vasc Surg ; 76(5): 1123-1132.e2, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-35868424

RESUMEN

OBJECTIVES: To investigate the impact of prophylactic zone 0 replacement with prosthetic grafts on the long-term prognosis and perioperative safety of zone 0 hybrid arch repair (HAR) when zone 0 is neither dilated nor pathologic. METHODS: We retrospectively reviewed 115 patients whose zone 0 aorta was neither dilated nor pathologic and who underwent zone 0 HAR from January 2009 to December 2020 and divided then into two groups depending on whether zone 0 was replaced, with 46 patients in the no-replacement group and 69 patients in the replacement group. Inverse probability of treatment weighting (IPTW) was used to balance the baseline difference, and outcomes were compared after IPTW adjustment. The primary end points were overall survival and adverse aortic events (AAEs). The secondary end points were early composite adverse events and other perioperative complications. Subgroup analysis was performed by age, diagnosis, zone 0 maximum diameter and risk stratification. RESULTS: The 5-year IPTW-adjusted overall survival rate was 84% in the no-replacement group 90% in the replacement group (P = .61). With death as a competing risk, the IPTW-adjusted cumulative incidence of AAEs at 5 and 10 years was 23% and 41% in the no-replacement group, and 14% and 25% in the replacement group, respectively (subdistribution hazard ratio [sHR], 0.56; 95% confidence interval [CI], 0.23-1.39; P = .23). Considering proximal complications alone, the replacement group exhibited lower 5-year (3% vs 18%) and 10-year (6% vs 36%) cumulative incidences of proximal complications (sHR, 0.11; 95% CI, 0.01-0.91; P = .04) after IPTW adjustment. A subgroup analysis demonstrated that the benefits of zone 0 replacement in decreasing AAEs were observed in those aged 60 years or less (sHR, 0.15; 95% CI, 0.03-0.75; P = .02) and those with type B aortic dissection (sHR, 0.24; 95% CI, 0.07-0.82; P = .02). Additionally, zone 0 replacement did not increase early composite adverse event morbidity (9% vs 21%; P = .08) or early mortality (7% vs 6%; P = .87). CONCLUSIONS: Although zone 0 was neither dilated nor pathologic, prophylactic zone 0 replacement in zone 0 HAR significantly decreased the incidence of proximal complications, without impairing perioperative safety. Additionally, this strategy was associated with benefits in reducing AAEs in younger patients and patients with type B aortic dissection. Thus, prophylactic zone 0 replacement should be considered for reconstructing a stable proximal landing zone in zone 0 HAR.


Asunto(s)
Aneurisma de la Aorta Torácica , Disección Aórtica , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Humanos , Implantación de Prótesis Vascular/efectos adversos , Aorta Torácica/diagnóstico por imagen , Aorta Torácica/cirugía , Procedimientos Endovasculares/efectos adversos , Estudios Retrospectivos , Resultado del Tratamiento , Disección Aórtica/cirugía , Aorta/cirugía , Pronóstico , Aneurisma de la Aorta Torácica/cirugía
12.
Front Cardiovasc Med ; 9: 880411, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35665244

RESUMEN

Background: To compare outcomes between sinus replacement (SR) and conservative repair (CR) for dissected roots with normal size. Methods: From October 2018 to April 2021, a prospective cohort study was carried out. Patients were assigned to two groups (SR group and CR group) according to whether they underwent sinus replacement. Propensity score matching was applied to adjust preoperative variables and Kaplan-Meier method was used for survival analysis. Results: Three hundred and eighty-seven patients were enrolled. In the whole cohort, 18 patients (4.7%) died postoperatively. The operative mortality of SR group was comparable to CR group (3.2% vs. 6.0%, p = 0.192 before matching; 3.5% vs. 7.0%, p = 0.267 after matching) and the incidence of hemostasis management under restarted cardiopulmonary bypass for root bleeding was lower in SR group (1.6% vs. 7.0%, p = 0.002 before matching; 2.1% vs. 8.5%, p = 0.03 after matching). The median follow-up duration was 12 months. There were 3 reoperations in the CR group. The estimated cumulative event rate of reoperation was 1.1 % at 12 months and 1.6% at 24 months in CR group, with a trend of a lower rate in the SR group (log-rank p = 0.089 before matching, p = 0.075 after matching). There was one late death in each group. The estimated cumulative event rate of death was 3.8% at 12 months and 24 months in the SR group, and was 6.6% in the CR group with no significant difference (log-rank p = 0.218 before matching, p = 0.120 after matching). Aortic regurgitation significantly improved postoperatively and remained stable during follow-up. Conclusions: Sinus replacement is a simple, safe, and effective technique for repairing severely dissected sinus with a comparable time spent in operation and excellent immediate and short-term results. It had the advantages of eliminating false lumen and avoiding aortic root bleeding.

13.
Front Cardiovasc Med ; 9: 905908, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35757328

RESUMEN

Objective: To develop and validate a nomogram model to predict postoperative 30-day mortality in acute type A aortic dissection patients receiving total aortic arch replacement with frozen elephant trunk technique. Method: Clinical data on 1,156 consecutive acute type A aortic dissection patients who got total aortic arch replacement using the frozen elephant trunk technique was collected from January 2010 to December 2020. These patients were divided into training and testing cohorts at random with a ratio of 7:3. To predict postoperative 30-day mortality, a nomogram was established in the training set using the logistic regression model. The novel nomogram was then validated in the testing set. The nomogram's calibration and discrimination were evaluated. In addition, we created four machine learning prediction models in the training set. In terms of calibration and discrimination, the nomogram was compared to these machine learning models in testing set. Results: Left ventricular end-diastolic diameter <45 mm, estimated glomerular filtration rate <50 ml/min/1.73 m2, persistent abdominal pain, radiological celiac trunk malperfusion, concomitant coronary artery bypass grafting and cardiopulmonary bypass time >4 h were independent predictors of the 30-day mortality. The nomogram based on these 6 predictors manifested satisfying calibration and discrimination. In testing set, the nomogram outperformed the other 4 machine learning models. Conclusion: The novel nomogram is a simple and effective tool to predict 30-day mortality rate for acute type A aortic dissection patients undergoing total aortic arch replacement with frozen elephant trunk technique.

14.
Front Cardiovasc Med ; 9: 882783, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35722105

RESUMEN

Background: The hybrid arch repair (HAR) is an appealing surgical option in the management of aortic arch diseases. The aim is to evaluate the short and mid-term outcomes of type II HAR involving replacement of the ascending aorta, arch debranching, and zone 0 stent graft deployment in diverse arch pathologies. Methods: 200 patients with various diffuse aortic pathologies involving the arch were enrolled between 2016 and 2019. Complex arch diseases included acute type A dissection (n = 129, 64.5%), acute type B dissection (n = 16, 8.0%), aortic arch aneurysm (n = 42, 21.0%) and penetrating arch ulcer (n = 13, 6.5%). Mortality, morbidity, survival and re-intervention were analyzed. Results: The overall 30-day mortality rate was 8.0% (16/200). Stroke was present in 3.5% (7/200) of the general cohort and spinal cord injury was occurred in 3.0% (6/200). Multivariable logistic analysis showed that cardiac malperfusion and CPB time were the risk factors associated with 30-day mortality. The mean follow-up duration was 25.9 months (range 1-57.2 months), and the 3-year survival rate was 83.1%. On Cox regression analysis, age, diabetes, cardiac malperfusion and CPB time predicted short and mid-term overall mortality. A total of 3 patients required reintervention during the follow-up due to the thrombosis of epiaortic artificial vessels (n = 1), anastomotic leak at the site of the proximal ascending aorta (n = 1) and the type I endoleak (n = 1). Conclusions: Type II HAR was performed with satisfactory early and mid-term outcomes in complex aortic arch pathologies.

16.
Front Cardiovasc Med ; 9: 820653, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35295249

RESUMEN

Objective: Hybrid total arch replacement (HTAR) was an alternative for type A aortic dissection (TAAD). This study aimed to evaluate the clinical and radiographical outcomes of HTAR for TAAD and to evaluate the clinical outcomes of performing this procedure under mild hypothermia. Methods: A total of 209 patients who underwent HTAR for TAAD were retrospectively analyzed and stratified into mild (n = 48) and moderate (n = 161) hypothermia groups to evaluate the effects of mild hypothermia on the clinical outcomes. Long-term clinical outcomes were evaluated by the overall survival and adverse aortic events (AAEs). A total of 176 patients with preoperative and at least one-time postoperative aortic computed tomography angiography in our institute were included for evaluating the late aortic remodeling (aortic diameter and false lumen thrombosis). Results: The median follow-up period was 48.3 (interquartile range [IQR] = 28.4-73.7) months. The overall survival rate was 88.0, 83.2, and 77.1% at the 1, 5, and 10 years, respectively, and in the presence of death as a competing risk, the cumulative incidence of AAEs was 4.8, 9.9, and 12.1% at the 1, 5, and 10 years. The aortic diameters were stable in the descending thoracic and abdominal aorta (P > 0.05 in all the measured aortic segments). A total of 100% complete false lumen thrombosis rate in the stent covered and distal thoracic aorta were achieved at 1 year (64/64) and 4 years (18/18), respectively after HTAR. The overall composite adverse events morbidity and mortality were 18.7 and 10.0%. Mild hypothermia (31.2, IQR = 30.2-32.0) achieved similar composite adverse events morbidity (mild: 14.6 vs. moderate: 19.9%, P = 0.41) and early mortality (mild: 10.4 vs. moderate: 9.9%, P = 1.00) compared with moderate hypothermia (median 27.7, IQR = 27-28.1) group, but mild hypothermia group needed shorter cardiopulmonary bypass (mild: 111, IQR = 93-145 min vs. moderate: 136, IQR = 114-173 min, P < 0.001) and aortic cross-clamping (mild: 45, IQR = 37-56 min vs. moderate: 78, IQR = 54-107 min, P < 0.001) time. Conclusion: Hybrid total arch replacement achieved desirable early and long-term clinical outcomes for TAAD. Performing HTAR under mild hypothermia was as safe as under moderate hypothermia. After HTAR for TAAD, dissected aorta achieved desirable aortic remodeling, presenting as stable aortic diameters and false lumen complete thrombosis. In all, HTAR is a practical treatment for TAAD.

17.
Front Cardiovasc Med ; 9: 809493, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35282342

RESUMEN

Background: The optimal arterial cannulation site for acute aortic dissection repair is unclear, especially for complex arch surgery. Axillary artery cannulation is widely accepted but adding femoral artery cannulation to it was considered to potentially improve perfusion and early outcomes. To clarify this point, a comparison of perioperative outcomes for these two different cannulation strategies was conducted regarding the pathological features of dissection. Methods: From January 2010 to December 2019, 927 consecutive patients underwent a total arch replacement combined with frozen elephant trunk for acute type A aortic dissection. The data, including detailed pathological features, were retrospectively collected and analyzed. Propensity score matching and multivariate logistic regression analysis were used for adjusting confounders that are potentially related to the outcome. Results: A total of 523 patients (56.3%) accepted a dual arterial cannulation (DAC group), and 406 patients (43.7%) received a single axillary artery cannulation (SAC group). In total, 388 pairs of patients were well-matched. Whether before or after adjusting the preoperative characteristics by matching, there were no significant differences in operative mortality (6.7 vs. 5.4%, P = 0.420 before matching; 5.4 vs. 5.4%, P = 1 after matching), stroke (6.7 vs. 5.4%, P = 0.420 before matching; 6.4 vs. 5.2%, P = 0.435 after matching), spinal cord injury (5 vs. 5.7%, P = 0.640 before matching; 5.4 vs. 5.7%, P = 1. After matching), and acute renal failure requiring dialysis (13.8 vs. 9.6%, P =0.050 before matching; 12.6 vs. 9.5%, P = 0.174) between the two groups. Dual arterial cannulation was not an independent protective factor of operative mortality (odds ratio [OR] 1.01, 95% confidence interval [CI] 0.55-1.86), stroke (OR 1.17, 95% CI 0.65-2.11), spinal cord injury (OR 1.17, 95% CI 0.65-2.11), and acute renal failure requiring continuous renal replacement therapy (CRRT) (OR 1.24, 95% CI 0.78-1.97) after adjusting for confounding factors by multivariable logistic regression analysis. In the subgroup analysis, no advantage of dual arterial cannulation was found for a particular population. Conclusions: Single axillary artery cannulation was competent in the complex arch repair for acute aortic dissection, presenting with a satisfactory result as dual arterial cannulation. Adding femoral artery cannulation was necessary when a sufficient flow volume could not be achieved by axillary artery cannulation or when a lower limb malperfusion existed.

18.
Vasc Endovascular Surg ; 56(1): 11-17, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34488512

RESUMEN

BACKGROUND: To evaluate the efficacy and safety of ascending aortoiliac bypass surgery for one-stage repair of adult coarctation of the aorta (CoA) and concomitant cardiac disease. METHODS: From March 2012 to October 2018, 51 consecutive CoA patients were treated with ascending aorta to bilateral iliac artery bypass concomitant with and cardiac surgerical procedures performed for a variety of reasons. A Y-shaped graft was used for the bypass procedure. We evaluated early outcomes, including postoperative death, systolic blood pressure and differences between upper and lower limb blood pressure. RESULTS: The average age was 41 years and 64.7% of patients were men. Simultaneous cardiac procedures included aortic valve replacement, ventricular septal defect repair, Bentall procedures and Wheat procedures. No deaths occurred in the early postoperative period. Three patients had delayed healing at the site of the abdominal lower quadrant incisions. The average systolic pressure in the upper limb and the average difference between the upper- and lower-limb blood pressure decreased significantly after surgery (162.7 ± 13.4 mmHg vs 128.4 ± 6.7 mmHg, P = .000; 69.6 ± 15.6 mmHg vs 8.7 ± 7.6 mmHg, P = .000, respectively); The systolic blood pressure in the lower limb increased after bypass surgery (93.1 ± 6.2 mmHg vs 119.6 ± 7.7 mmHg, P = .000). The follow-up rate was 100%, with an average follow-up time of 61 months. Six patients (11.8%) had graft stenosis or occlusion. Three patients (5.9%) underwent endovascular embolectomy. CONCLUSIONS: In our small series, ascending aortoiliac bypass for one-stage repair of CoA with concomitant cardiac lesions appears safe and efficacious in effectively reduceing differences between upper and lower limb systolic blood pressure. Further study with larger sample size and longer follow-up is needed.


Asunto(s)
Coartación Aórtica , Injerto Vascular , Adulto , Aorta , Coartación Aórtica/complicaciones , Coartación Aórtica/diagnóstico por imagen , Coartación Aórtica/cirugía , Puente Cardiopulmonar , Humanos , Masculino , Resultado del Tratamiento
19.
JACC Asia ; 2(7): 869-878, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36713764

RESUMEN

Background: Many countries and regions have established multicenter registration studies to improve the outcomes of acute type A aortic dissection (ATAAD). Objectives: The aims of this study were to report actual preoperative management, surgery type, and early outcomes of surgical treatment for ATAAD in China. Methods: This cohort study uses data from the China Registry of Type A Aortic Dissection, a national clinical registry to investigate management of patients with Stanford type A aortic dissection. The data, including surgical management and outcomes of patients with ATAAD, were analyzed from January 2018 to December 2021. Results: A total of 1,058 patients with ATAAD were enrolled in this study between January 2018 and December 2021. The mean age of all patients was 51.6 ±11.7 years. The median interval from onset to hospital was 10.65 hours (IQR: 6-24 hours), and the median interval from entering the emergency room to starting operation was 13 hours (IQR: 4.08-28.7 hours). Total arch repair was performed in 938 patients (88.7%), and frozen elephant trunk repair was performed in 800 patients (75.6%). The incidence of early mortality was 7.6%. Conclusions: The population of patients with ATAAD in China experienced a longer interval from onset to arrival at the hospital, received more extensive aortic arch repair, and showed a relatively lower early mortality. These findings suggest that there may be a huge survivor bias in patients with ATAAD in China, more efforts should be made to promote prehospital emergency care and preoperative management of Chinese ATAAD patients. (A multicenter registration study of aortic dissection in China; ChiCTR1800015338).

20.
Front Surg ; 9: 1044089, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36684352

RESUMEN

Background: Frozen elephant trunk technique (FET) has been proven to provide an excellent landing zone for second-stage thoracoabdominal (TA) aortic repair. The aim of this study was to evaluate the impact of FET in TA aortic repair with normothermic iliac perfusion. Methods: From January 2008 to December 2019, 144 patients undergoing TA repair with normothermic iliac perfusion were enrolled in this study. Early and mid-term outcomes of patients with previous FET implantation (group A, n = 62) were compared with patients without previous FET implantation (group B, n = 82). The logistic regression analysis was performed to investigate the risk factors for adverse events, which were defined as early death, permanent stroke, permanent paraplegia, or permanent renal failure necessitating dialysis. Results: The proximal aortic clamp time and operating time was 14.26 ± 5.57 min and 357.40 ± 94.51 respectively in group A, which were both significantly shorter than that in group B (18.67 ± 5.24 min and 18.67 ± 5.24 min). The incidence of adverse event was significantly lower in group A than that in group B (9.7% vs. 25.6%, P = 0.027). There was no significant difference between two groups with regard to other complications or late outcomes. In addition, age >50 years, a Ccr < 90 ml/min/1.73 m2 and the operating time were identified as significant risk factors through logistic regression analysis for adverse events of TA repair. Conclusions: The FET technique simplifies the operative technique of proximal anastomosis, decreases the operating time and improves the early outcomes in TA repair, whereas does not provide a significant benefit with regard to late outcomes. Long-term follow-up and studies with larger sample sizes are necessary for further confirmation.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...