Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Europace ; 25(7)2023 07 04.
Artículo en Inglés | MEDLINE | ID: mdl-37410808

RESUMEN

AIMS: High precordial leads (HPL) on the resting electrocardiogram (ECG) are widely used to improve diagnostic detection of type 1 Brugada ECG pattern (Br1ECGp). A parasympathetic activation marks the initial recovery phase of treadmill stress testing (TET), and this can be useful for detecting the typical ECG pattern. Our study aimed to evaluate the role of a new HPL-treadmill exercise testing (TET) protocol in detecting Br1ECGp fluctuation compared to resting HPL-ECG. METHODS AND RESULTS: 74 out of 163 patients of a Brugada syndrome (BrS) Brazilian cohort (GenBra Registry) underwent exercise testing with HPL-TET protocol. Precordial leads were displayed in strategic positions in the right and left parasternal spaces. The step-by-step analysis included ECG classification (as presence or absence of Br1ECGp) in standard vs. HPL leads placement in the following sequences: resting phase, maximal exercise, and the passive recovery phase (including 'quick lay down'). For heart rate recovery (HRR) measurements and comparisons, a Student's t-test was applied. McNemar tests compared the detection of Br1ECGp. The significance level was defined as P < 0.05. Fifty-seven patients (57/74; 77%) were male, the mean age was 49.0 ± 14, 78.4% had spontaneous BrS, and the mean Shanghai score was 4.5. The HPL-TET protocol increased Br1ECGp detection by 32.4% against resting HPL-ECG (52.7% vs. 20.3%, P = 0.001) alone. CONCLUSION: Stress testing using HPL with the passive recovery phase in the supine position offers an opportunity to unmask the type 1 Br1ECGp, which could increase the diagnostic yield in this population.


Asunto(s)
Síndrome de Brugada , Prueba de Esfuerzo , Humanos , Masculino , Femenino , China , Síndrome de Brugada/diagnóstico , Electrocardiografía/métodos , Brasil
2.
Circ Arrhythm Electrophysiol ; 16(2): e011391, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36720007

RESUMEN

BACKGROUND: Arrhythmogenic right ventricular cardiomyopathy (ARVC), a rare inherited disease, causes ventricular tachycardia, sudden cardiac death, and heart failure (HF). We investigated ARVC clinical features, genetic findings, natural history, and the occurrence of life-threatening arrhythmic events (LTAEs), HF death, or heart transplantation (HF-death/HTx) to identify risk factors. METHODS: The clinical course of 111 consecutive patients with definite ARVC, predictors of LTAE, HF-death/HTx, and combined events were analyzed in the entire cohort and in a subgroup of 40 patients without sustained ventricular arrhythmia before diagnosis. RESULTS: The 5-year cumulative probability of LTAE was 30% and HF-death/HTx was 10%. Predictors of HF-death/HTx were reduced right ventricle ejection fraction (HR: 0.93; P=0.010), HF symptoms (HR: 4.37; P=0.010), epsilon wave (HR: 4.99; P=0.015), and number of leads with low QRS voltage (HR: 1.28; P=0.001). Each additional lead with low QRS voltage increased the risk of HF-death/HTx by 28%. Predictors of LTAE were prior syncope (HR: 1.81; P=0.040), number of leads with T wave inversion (HR: 1.17; P=0.039), low QRS voltage (HR: 1.12; P=0.021), younger age (HR: 0.97; P=0.006), and prior ventricular arrhythmia/ventricular fibrillation (HR: 2.45; P=0.012). Each additional lead with low QRS voltage increased the risk of LTAE by 17%. In patients without ventricular arrhythmia before clinical diagnosis of ARVC, the number of leads with low QRS voltage (HR: 1.68; P=0.023) was independently associated with HF-death/HTx. CONCLUSIONS: Our study demonstrated the characteristics of a specific cohort with a high prevalence of arrhythmic burden at presentation, male predominance, younger age and HF severe outcomes. Our main results suggest that the presence and extension of low QRS voltage can be a risk predictor for HF-death/HTx in ARVC patients, regardless of the arrhythmic risk. This study can contribute to the global ARVC risk stratification, adding new insights to the international current scientific knowledge.


Asunto(s)
Displasia Ventricular Derecha Arritmogénica , Insuficiencia Cardíaca , Humanos , Masculino , Femenino , Brasil , Arritmias Cardíacas/epidemiología , Muerte Súbita Cardíaca/etiología , Factores de Riesgo , Fibrilación Ventricular , Insuficiencia Cardíaca/complicaciones , Electrocardiografía , Medición de Riesgo/métodos
3.
Sci Rep ; 12(1): 5745, 2022 04 06.
Artículo en Inglés | MEDLINE | ID: mdl-35388029

RESUMEN

Emotional distress is related to recurrence of syncope compromising patient's quality of life (QoL). The aim of this study was to determine if weekly sessions of psychotherapy reduce recurrence of events and improve QoL by SF-36 among patients with refractory vasovagal syncope. A randomised controlled pilot trial including 10 patients with recurrent vasovagal syncope and positive tilt table test was conducted. Known cardiac disease and ongoing psychotherapeutic interventions were the main exclusion criteria. All patients received standard of care treatment. Additionally, after randomisation, half of the patients underwent weekly sessions of psychotherapy for 12 months. Analysis of recurrence of events and QoL showed no significant change in the control group but, in the intervention group, there was a significant reduction in the rate of near-syncope episodes per month (5.7 ± 1.4 × 1.7 ± 1.0; P < 0.01), syncope in 1 year (4.6 ± 0.9 × 1.0 ± 0.7; P < 0.01) and a significant improvement in the overall assessment of QoL (44.1 ± 10.0 vs. 70.3 ± 10.3, P < 0.01). In conclusion, patients with refractory vasovagal syncope undergoing regular psychotherapeutic intervention had less recurrence of events and improved their quality of life in 1 year.Trial Registration: ClinicalTrials.gov number, NCT04252729.


Asunto(s)
Calidad de Vida , Síncope Vasovagal , Humanos , Psicoterapia , Recurrencia , Síncope Vasovagal/terapia , Pruebas de Mesa Inclinada
4.
J Cardiovasc Electrophysiol ; 31(4): 924-933, 2020 04.
Artículo en Inglés | MEDLINE | ID: mdl-32108399

RESUMEN

OBJECTIVE: To compare the prevalence of esophageal and periesophageal thermal injury in patients undergoing radiofrequency (RF) atrial fibrillation (AF) ablation using 8 mm tip catheters during three different esophageal protection strategies. METHODS: Forty-five consecutive patients with paroxysmal or persistent AF underwent first ablation procedure, besides esophagogastroduodenoscopy (EGD) combined with radial endosonography (EUS) performed before and after the pulmonary vein (PV) isolation. Before the procedure, patients were randomly assigned to one of three esophageal lesion protection strategies: group I-without any protective or monitoring dispositive and limiting RF applications to 30 W for 20 seconds, in left atrium posterior wall (LAPW); group II-power and time of RF delivery, up to 50 W for 20 seconds at LAPW, limited by esophageal temperature monitoring; group III-applications of RF in LAPW with fixed power application of 50 W for 20 seconds during continuous esophageal cooling. RESULTS: Baseline characteristics of patients were similar in all groups. The four PVs were isolated in 14 (93.3%), 13 (86.7%), and 15 (100%) patients, respectively in groups I, II, and III. The mean RF power was significantly higher (P < .001) in the posterior side of PVs in group III. Post-AF ablation EGD and EUS revealed two esophageal wall ulcerations and two periesophageal mediastinal edemas only in the esophageal cooling group (P = .008). CONCLUSION: Esophageal cooling balloon strategy resulted in a higher RF power energy delivery when ablating at the LA posterior wall, using 8 mm nonirrigated tip catheters under temperature mode control. Despite that, patients presented a relatively low incidence of esophageal and periesophaeal injuries.


Asunto(s)
Fibrilación Atrial/cirugía , Quemaduras/prevención & control , Ablación por Catéter , Esófago/lesiones , Venas Pulmonares/cirugía , Adulto , Brasil , Quemaduras/diagnóstico por imagen , Quemaduras/epidemiología , Catéteres Cardíacos , Ablación por Catéter/efectos adversos , Ablación por Catéter/instrumentación , Diseño de Equipo , Esófago/diagnóstico por imagen , Femenino , Humanos , Masculino , Persona de Mediana Edad , Prevalencia , Resultado del Tratamiento
5.
Value Health Reg Issues ; 8: 36-42, 2015 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-29698169

RESUMEN

OBJECTIVE: To analyze the cost-effectiveness and cost-utility of dabigatran compared with warfarin in patients with nonvalvular atrial fibrillation with moderate to high risk of ischemic stroke or systemic embolism and eligible for treatment with anticoagulants. METHODS: Markov-based economic analysis was performed to estimate treatment costs and outcomes. Epidemiological and efficacy data were determined after a critical revision of the medical literature. Unit costs were taken from Brazilian official databases. Only direct medical costs were covered. Costs and benefits were discounted at a rate of 5% per year. Outcomes were expressed as life-year (LY) and quality-adjusted life-year (QALY). RESULTS: Dabigatran use is cost-effective in terms of LY and QALY considering a willingness-to-pay threshold of 3 times gross domestic product per capita of 2010 (Brazilian real 57,048/US $24,275.74) per LY and QALY saved in both analyzed perspectives (private and public health care systems). CONCLUSIONS: Dabigatran use improves patient survival and quality of life compared with warfarin. This represents the best therapeutic option in terms of cost and effectiveness in the prevention of ischemic stroke and systemic embolism in patients with nonvalvular atrial fibrillation.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...