1.
Ultrason Imaging ; 22(1): 57-72, 2000 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-10823497

RESUMEN

The goal of this study was to develop a calibrated on-line technique to extract as much diagnostically-relevant information as possible from conventional video-format echograms. The final aim is to improve the diagnostic potentials of medical ultrasound. Video-output images were acquired by a frame grabber board incorporated in a multiprocessor workstation. Calibration images were obtained from a stable tissue-mimicking phantom with known acoustic characteristics. Using these images as reference, depth dependence of the gray level could fairly be corrected for the transducer performance characteristics, for the observer-dependent equipment settings and for attenuation in the examined tissues. Second-order statistical parameters still displayed some nonconsistent depth dependencies. The results obtained with two echoscanners for the same phantom were different; hence, an a posteriori normalization of clinical data with the phantom data is indicated. Prior to processing of clinical echograms,. the anatomical reflections and echoless voids were removed automatically. The final step in the preprocessing concerned the compensation of the overall attenuation in the tissue. A 'sliding window' processing was then applied to a region of interest (ROI) in the 'back-scan converted' images. A number of first and second order statistical texture parameters and acoustical parameters were estimated in each window and assigned to the central pixel. This procedure results in a set of new 'parametric' images of the ROI, which can be inserted in the original echogram (gray value, color) or presented as a color overlay. A clinical example is presented for illustrating the potentials of the developed technique. Depending on the choice of the parameters, four full resolution calibrated parametric images can be calculated and simultaneously displayed within 5 to 20 seconds. In conclusion, an on-line technique has been developed to estimate acoustic and texture parameters with a reduced equipment dependence and to display acoustical and textural information that is present in conventional echograms.


Asunto(s)
Ecoencefalografía/métodos , Procesamiento de Imagen Asistido por Computador , Acústica , Calibración , Humanos , Recién Nacido , Fantasmas de Imagen , Ultrasonido
2.
Ultrasound Med Biol ; 25(4): 527-30, 1999 May.
Artículo en Inglés | MEDLINE | ID: mdl-10386727

RESUMEN

This study addresses the value of operator-independent computer processing of ultrasonograms of the developing brain. With this aim, routine cranial ultrasonograms obtained from 39 term and preterm infants without clinical or sonographic evidence of brain damage were analyzed by five observers. The procedure, respectively, included: 1. the definition of four regions of interest (ROI), one white matter and one grey matter area on each side of the brain; 2. digitization of the sonogram data within these ROIs; 3. correction for the equipment settings, using data from a tissue-mimicking phantom as a reference; and 4. calculation of four sonogram characteristics (i.e., mean echo level, MEAN, signal-to-noise ratio, SNR, and axial and lateral correlation, CORAX and CORLAT, of the echo level co-occurrence matrix). Significant differences between both sides of the brain or a significant influence of ROI size were not found. The interobserver spread was considerable, but less than the intersubject spread. Two sonogram characteristics seemed strongly correlated in white and grey matter (CORAX and CORLAT) and another only in white matter (SNR with CORAX and CORLAT). MEAN seemed not to be correlated with any other characteristic. Furthermore, it was found that maturation equally decreases white and grey matter MEAN and, thus, hardly affects the ratio between the two. An effect on the other sonogram characteristics was only found in the white matter (i.e., an increase of SNR and a decrease of CORAX and CORLAT). Except for MEAN, the grey matter sonogram characteristics seem hardly affected by maturation. In view of these findings, we conclude that quantitative ultrasonography reveals white and grey matter maturation and, furthermore, provides a conceptional-age-independent reference (MEAN white:grey matter ratio) that might be found to facilitate the detection of pathologic brain alterations.


Asunto(s)
Encéfalo/crecimiento & desarrollo , Ventrículos Cerebrales/diagnóstico por imagen , Factores de Edad , Preescolar , Humanos , Lactante , Modelos Lineales , Variaciones Dependientes del Observador , Fantasmas de Imagen , Valores de Referencia , Estadísticas no Paramétricas , Ultrasonografía/instrumentación , Ultrasonografía/métodos , Ultrasonografía/estadística & datos numéricos