RESUMEN
O avanço da tecnologia de digitalização de imagens e desenvolvimento de dispositivos de fresagem possibilitaram a otimização de diversos processos na Odontologia. O emprego do escaneamento intraoral e do sistema CAD-CAM (CAD - Computer Aided Design; CAM - Computer Aided Manufacturing) aprimorou a realização de reabilitações protéticas, permitindo a obtenção de peças de alta qualidade em tempo reduzido. O objetivo deste trabalho é relatar um caso de reabilitação de um incisivo central inferior a partir de escaneamento intraoral, com scanner Omnicam (DentsplySirona Charlotte, NC, EUA) e aplicação do sistema CAD-CAM.
The advancement of image digitization technology and the development of milling devices have made it possible to optimize various processes in Dentistry. The use of intraoral scanning and the CAD-CAM system (CAD - Computer Aided Design; CAM - Computer Aided Manufacturing) has improved the performance of prosthetic rehabilitations, allowing the obtaining of high quality parts in a reduced time. The objective of this work is to report a case of rehabilitation of a lower central incisor using intraoral scanning, with an Omnicam scanner (Dentsply Sirona) and application of the CAD-CAM system.
Asunto(s)
Humanos , Masculino , Persona de Mediana Edad , Rehabilitación , Diseño Asistido por Computadora , Odontología , Modelos AnatómicosRESUMEN
OBJECTIVES: To evaluate and compare the optical properties and relative translucency parameter of CAD-CAM restorative materials. METHODS: Four CAD-CAM materials were evaluated: Lava Ultimate (LU), Grandio Blocs (GB), VITA Enamic (VE), and VITA Mark II (VM). Disk-shaped samples in shade A2-HT were prepared (n = 10) and polished to 1.00 ± 0.01 mm of thickness. Scattering (S), absorption (K), albedo (a) coefficient, transmittance (T%), light reflectivity (RI), infinite optical thickness (X∞), and radiative transfer coefficients (µa, and µ'S) were calculated using Kubelka-Munk method and Thennadil's semi-empirical approach. Root Mean Square Error (RMSE) and Goodness of Fit (GFC) were used as performance optical behavior. Translucency differences were evaluated using the relative translucency parameter (RTP00) and 50:50 % translucency perceptibility and acceptability thresholds (TPT00 and TAT00). RESULTS: The spectral distribution of S, K, T%, RI, and X∞ was wavelength-dependent. GFC and RMSE values indicated good spectral behavior matches and good comparative spectral values for RI in LU-GB, LU-VE, and GB-VE, and for K in VE-VM. VM displayed the highest scattering values across the wavelengths, while VE and VM showed lower absorption at shorter wavelengths. LU and GB had the highest transmittance. The X∞ values indicated that all 1.0 mm thick materials could be influenced by the background. No good spectral match and no good comparative spectral values were found between CAD-CAM materials and anterior bovine maxillary specimens. VM had the lowest RTP00 values with perceptible and unacceptable differences compared to CAD-CAM materials evaluated. SIGNIFICANCE: Understanding the optical behavior of different CAD-CAM materials was essential for guiding clinicians in material selection and optimizing their clinical performance. The findings confirm that the different compositions and microstructure impact the optical properties and translucency of CAD-CAM restorative materials.
RESUMEN
OBJECTIVE: This in vitro study aimed to evaluate the effectiveness of a printed surgical guide for root sectioning in the socket-shield technique. MATERIALS AND METHODS: A typodont model of the maxilla with augmented filler was used for the upper right central incisor, and CBCT images were obtained. Two types of vertical root sectioning guides were tested: one with a buccal sleeve (Group A, n = 10) and another with a buccal orientation slit (Group B, n = 10). Control group (n = 10) performed freehand cuts on printed models. After crown cutting with diamond burs, root sectioning was conducted using an ultrasonic tip with the guides. Mean and standard deviation were calculated for the remaining root length, width, and volume. Data were analyzed using the Kruskal-Wallis test and Dunn's post hoc test. RESULTS: Statistical analysis showed significant differences in root width between the control group (2.0 mm) and both Groups A (2.655 mm; p < 0.0001) and B (2.460 mm; p < 0.0001). Group B (5.585 mm) also showed a significant difference in root remnant compared with the control (13.880 mm; p < 0.0043). Groups A and B did not differ significantly from each other. CONCLUSIONS: The socket shield technique is safe and effective, this study aimed to add improvements through the introduction of surgical guides, facilitating the root section, which is the critical phase so that the parameters that are requisite for success are achieved in terms of width, length, and volume of the root remnant. Both guided techniques effectively facilitated root sectioning, maintaining satisfactory root thickness and length. CLINICAL SIGNIFICANCE: Sectioning the root is challenging for the correct angulation to remove the palatal portion in the socket shield technique. Therefore, modifying this technique with the use of the presented guides, it is possible to prevent damage to the soft tissues and to plan the surgery with the help of cone beam computed tomography (CBCT) scans to remove the root apex and maintain the root remnant with a thickness greater than 1.5 mm, making the socket-shield technique more predictable.
RESUMEN
PURPOSE: To evaluate, through in vitro studies, the bond strength of vitreous and hybrid ceramics with self-etching surface treatment compared to conventional treatment. METHODS: This systematic review followed the preferred reporting items for systematic reviews and meta-analyses (PRISMA) and was registered on the open science framework (OSF) platform for in vitro studies. A population, intervention, control, and outcome (PICO) question was formulated: "Does the surface conditioning of glass and hybrid ceramics with self-etching silane present a bond strength similar to that of conventional bonding?". A literature search was carried out in the PubMed, Embase, Web of Science, Cochrane Library, and ProQuest databases until September 2023. The Joanna Briggs Institute (JBI) critical appraisal guidelines for quasi-experimental studies were used for risk assessment of bias. The meta-analysis was based on the inverse variance (IV) method (p < 0.05). RESULTS: A total of 29 in vitro studies published between 2017 and 2022 were included in this systematic review, totaling 1889 ceramic samples. The meta-analysis indicated a significant decrease in the bond strength of HF 4%-5% with silane compared to self-etching (p < 0.05; MD: 0.34; 95% CI: 0.13-0.35; I2 = 3%, p = 0.42), while it indicated that there was no significant difference between self-etching compared to 9%-10% HF with silane (p = 0.92; MD: 0.02; 95% CI: -0.32 to 0.36; I2 = 14%, p = 0.32). CONCLUSION: Self-etching primer presents bond strength that is superior to or similar to conventional surface treatment on glass and hybrid ceramics.
RESUMEN
OBJECTIVES: To evaluate the influence of microstructure and chemical composition on the optical properties of CAD-CAM lithium disilicate glass-ceramics. METHODS: Samples (n = 5; 1.0 mm thickness) of shades A1, A2, and A3 were fabricated from CAD-CAM ceramic blocks (Ivoclar Vivadent): IPS e.max® CAD LT (emLT) and HT (emHT). Samples were polished to 1.0 ± 0.01 mm in thickness. The optical properties (R- reflectance; T- transmittance; µs'- reduced scattering and µa- absorption coefficients) from the post-crystallized samples were determined using the inverse adding-doubling (IAD) method based on integrating-sphere measurements. Additionally, scanning electron microscopy (SEM) and X-ray diffraction (XRD) techniques were used to evaluate the microstructural properties. Energy-dispersive X-ray (EDX) was employed to analyze the chemical composition. The chemical and structural characterization were performed before and after crystallization of the ceramic samples. RESULTS: emLT showed higher values of µs'and lower values of µa and T than emHT for each shade in all wavelengths (p < 0.003). Considering T for emHT, there were no statistical differences for shades A1 and A2 at 488 nm and 514.5 nm (p > 0.003) and shades A1 and A3 at 457.9 nm (p > 0.003). emLT showed particle length ranging from 0.74 to 2.78 µm (mean = 1.57 µm and RF-relative frequency = 28 %) and particle width ranging from 0.21 to 0.74 µm (mean = 0.30 µm and RF = 31 %). emHT showed particle length ranging from 0.83 to 3.08 µm (mean = 1.86 µm and RF = 21 %) and particle width ranging from 0.24 to 1.12 µm (mean = 0.56 µm and RF = 28 %). In comparison with emHT, emLT showed greater vol% for C, K, and Zr and lower vol% for O and Al. SIGNIFICANCE: The optical properties of CAD-CAM lithium disilicate glass-ceramics are influenced by the chemical composition and, consequently, by the material microstructure.
RESUMEN
PURPOSE: To analyze the microstructural and mechanical properties of various commercial trademarks of lithium disilicate ceramics for CAD-CAM systems. MATERIALS AND METHODS: Specimens of different lithium disilicate ceramics were obtained and randomized into 5 groups (n = 14): EM: e.max CAD; RT: Rosetta SM; EV: Evolith; PM: Smile-Lithium CAD; and, HS: HaHaSmile. The microstructural analysis was performed by X-ray diffraction (XRD) and scanning electron microscopy (SEM); for flexural strength, the three-point bending flexure test was used. XRD and SEM data were qualitatively evaluated. Data from flexural strength were assessed with one-way ANOVA test (α = 0.05) and Weibull analysis. RESULTS: High peaks corresponding to the lithium metasilicate and lithium disilicate pattern with similar intensities were observed in all ceramics in the XRD analysis. SEM images showed similar patterns of crystalline structure in the EM and RT ceramics, while the other three groups presented different crystal morphologies than the previous ones and were similar to each other. No differences were found in flexural strength among the groups (p = 0.28). CONCLUSIONS: The CAD-CAM lithium disilicate ceramics showed comparable crystalline intensities. The microstructure of the EM and RT ceramics were different from the other groups. Flexural strength was similar among all ceramics.
RESUMEN
PURPOSE: To investigate the effects of different surface treatments and thermal cycling on the shear bond strength between 3D-printed teeth and denture bases. MATERIAL AND METHODS: For the shear bond strength (SBS) test, the specimens were the maxillary central incisors (11 × 9 × 7 mm) bonded on a cylindrical base (20 × 25 mm). The control group was heat-cured polymethylmethacrylate (PMMA) (N = 20). The printed group was divided into five subgroups (N = 20): no treatment, sandblasting with aluminum oxide (Al2O3), methyl methacrylate monomer, acetone, and adhesive with urethane dimethacrylate. Half of the samples were subjected to 2000 thermal cycling cycles, and all samples were subjected to the SBS test. The failure mode was established as adhesive, cohesive, or mixed through stereomicroscopic analysis. The surface roughness test (Sa) was performed using optical profilometry, and the rectangular specimens (14 × 14 × 2.5 mm) were divided into four groups according to the surface treatments (N = 7 per group). Paired T and Wilcoxon tests were conducted to perform comparisons within the same group. The Kruskal-Wallis and Dwass-Steel-Critchlow-Fligner post-hoc tests were conducted to compare the groups. RESULTS: Al2O3 sandblasting in the 3D-printed groups achieved high SBS values comparable to those of the control group in the thermal cycled (p = 0.962) and non-thermal cycled samples (p = 0.319). It was the only treatment capable of modifying the surface of the 3D-printed resin, thereby increasing the roughness (p = 0.016). CONCLUSIONS: Sandblasting is recommended to increase the bond strength between the tooth and denture bases.
RESUMEN
Purpose: To evaluate the preferences of dental practitioners for tooth-supported crowns dental ceramics by means of an online survey and to assess the influence of age, gender, years of experience, and dental specialty on those preferences. Materials and Methods: An anonymous questionnaire was delivered online through Google Surveys, targeting 796 dentists. It contained 17 dichotomous, closed questions with two sections. The first section dealt with general characteristics, including age, gender, years of experience, training in prosthodontics, and hours worked per week. The second section included questions regarding preferences of different materials for crowns, and the use of digital workflows. Analyses were carried out with Stata 14.0 software (StataCorp, TX, USA). A significance level of p=0.05 was adopted. Results: 248 surveys were answered. Practitioners in Chile preferred lithium disilicate for the anterior region (55.2%) but also for the posterior area (40.7%), regardless of their age, gender, years since graduation, hours worked per week or any training in prosthodontics. Chilean dentists over 50 years old considered zirconia almost 4 times more than those under 30 years old for anterior crowns (51.85%). 59.68% of dentists take digital impressions, and 37.10% have access to chairside CAD/CAM technology. In this group, 54.4% preferred feldspathic ceramic for anterior and 23.9% for posterior crowns. Conclusions: While there is a wide range of dental ceramic materials, these results provide a snapshot of the current trends in Chile where lithium disilicate is the most preferred ceramic material for tooth-supported crowns, and metal-ceramic is the least preferred material.
RESUMEN
OBJECTIVE: To evaluate the effect of the deterioration of computer aided design/computer aided manufacturing (CAD/CAM) burs during zirconia milling, on surface roughness, contact angle, and fibroblast viability. MATERIALS AND METHODS: Ceramic blocks were milled and 75 ceramic disks (8 × 1.5 mm) made and allocated into three groups (n = 25): G1-brand new 2L and 1L burs, G2-2L bur at the end of lifetime and brand new 1L bur and G3-both burs at the end of their lifetimes. Roughness (Ra, Rq, and Rz) was evaluated using a 3D optical profilometer, the contact angle by the sessile drop method and the cell viability of the mouse NIH/3T3 fibroblast, using the Alamar Blue assay at intervals of 24, 48, and 72 h (ISO 10993-5). Data were analyzed by one-way ANOVA and Kruskal-Wallis tests (p ≤ 0.05). RESULTS: Roughness increased as the burs deteriorated and G3 (0.27 ± 0.04) presented a higher value for Ra (p < 0.001). The highest contact angle was observed in G3 (86.2 ± 2.66) when compared with G1 (63.7 ± 12.49) and G2 (75.3 ± 6.36) (p < 0.001). Alamar Blue indicated an increase in cell proliferation, with no significant differences among the groups at 24 and 72 h (p > 0.05). CONCLUSIONS: The deterioration of the burs increased the surface roughness and decreased the wettability, but did not interfere in cell viability and proliferation. CLINICAL SIGNIFICANCE: The use of custom zirconia abutments represents an effective strategy for single crowns restorations. Our findings suggest that these abutments can be efficiently milled using CAD/CAM burs within their recommended lifetime.
Asunto(s)
Diseño Asistido por Computadora , Propiedades de Superficie , Circonio , Circonio/química , Ratones , Animales , Pilares Dentales , Materiales Biocompatibles , Células 3T3 NIH , Ensayo de MaterialesRESUMEN
Purpose: To evaluate, in vitro, the efficiency of a novel apparatus to test the adherence and penetration of bacteria on different membranes for guided regeneration. Methodology: To create the 3D device, Computer Aided Design/Computer Aided Manufacturing (CAD/CAM) systems were used. Three types of biomaterials were tested (n = 6): (DT) a collagen membrane; (DS) a polymer membrane; and (LP) a dense polytetrafluoroethylene barrier. The biomaterials were adapted to the apparatuses and challenged with two different monospecies bacterial culture of A. actinomycetemcomitans b and S. mutans. After 2 h, bacterial adherence and penetration were quantified by counting the number of colony-forming units (CFUs). Two specimens from each group were used for image analysis using Confocal Laser Scanning Microscopy. Statistical analysis was performed. Findings: The DS group had a higher adherence of S. mutans compared to A. actinomycetemcomitans b (p = 0.05). There was less adherence of A. actinomycetemcomitans b in the DS group, compared to the LP (p = 0.011) and DT (p < 0.001) groups. Only the membranes allowed penetration, which was blocked by barriers. The DT group allowed a greater penetration of S. mutans to occur compared to A. actinomycetemcomitans b (p = 0.009), which showed a higher penetration into the DS membranes compared to S. mutans (p = 0.016). The penetration of A. actinomycetemcomitans b through DS was higher compared to its penetration through DT and LP (p < 0.01 for both). DT and DS allowed a greater penetration of S. mutans to occur compared to LP, which prevented both bacterial species from penetrating. Conclusion: The apparatus allowed for the settlement and complete sealing of the biomaterials, enabling standardization.
RESUMEN
OBJECTIVE: To evaluate the effect of polishing and bleaching on the recovery of lightness, color, whiteness, and relative translucency parameter (RTP) in CAD/CAM materials and changes in these properties when another staining in coffee was conducted after the treatments. MATERIALS AND METHODS: Disks of Lava Ultimate (LU), Vita Enamic (VE), IPS Empress CAD (EMP), IPS e.max CAD (EMAX), and Vita Suprinity (VS) were (1) not treated (control), (2) polished with Proxyt or (3) Ceramisté, (4) bleached with Opalescence PF or (5) Whiteness HP Blue, and (6) air polished with Clinpro Prophy Powder. CIE L*a*b* color coordinates were registered at baseline (R0), after staining with coffee for 30 min daily for 36.5 days and treatment (R1), and after another staining (R2). Differences (R1-R0 and R2-R0) in lightness (ΔL00), color (ΔE00), RTP (ΔRTP00), and whiteness (ΔWID) were evaluated by mixed repeated measures ANOVA and 95% confidence intervals (α = 0.05) and interpreted in function of their respective 50:50% PT and AT thresholds. Topography was evaluated by scanning electron microscopy (SEM). RESULTS: In LU, Opalescence PF and Proxyt decreased Δ L 00 R 1 - R 0 $$ {\Delta L}_{00\left({R}_1\hbox{--} {R}_0\right)} $$ , Δ E 00 R 1 - R 0 $$ {\Delta E}_{00\left({R}_1\hbox{--} {\mathrm{R}}_0\right)} $$ , and ΔWI D R 1 - R 0 $$ {\Delta \mathrm{WI}}_{\mathrm{D}\left({R}_1\hbox{--} {R}_0\right)} $$ and showed lower Δ L 00 R 2 - R 0 $$ {\Delta L}_{00\left({R}_2\hbox{--} {R}_0\right)} $$ , Δ E 00 R 2 - R 0 $$ {\Delta E}_{00\left({R}_2\hbox{--} {R}_0\right)} $$ , and ΔWI D R 2 - R 0 $$ {\Delta \mathrm{WI}}_{\mathrm{D}\left({R}_2\hbox{--} {R}_0\right)} $$ . In VE, all treatments decreased Δ L 00 R 1 - R 0 $$ {\Delta L}_{00\left({R}_1\hbox{--} {R}_0\right)} $$ , Δ E 00 R 1 - R 0 $$ {\Delta E}_{00\left({R}_1\hbox{--} {R}_0\right)} $$ , and ΔWI D R 1 - R 0 $$ {\Delta \mathrm{WI}}_{\mathrm{D}\left({R}_1\hbox{--} {R}_0\right)} $$ , whereas Δ L 00 R 2 - R 0 $$ {\Delta L}_{00\left({R}_2\hbox{--} {R}_0\right)} $$ , Δ E 00 R 2 - R 0 $$ {\Delta E}_{00\left({R}_2\hbox{--} {R}_0\right)} $$ , and ΔWI D R 2 - R 0 $$ {\Delta \mathrm{WI}}_{\mathrm{D}\left({R}_2\hbox{--} {R}_0\right)} $$ were lower in Opalescence PF than in the control group. In both moments, ΔE00 and ΔWID in EMP (also ΔL00) and EMAX were higher in Opalescence PF than in the control group, from which the other treatments did not differ in R1-R0. In EMP, Δ E 00 R 2 - R 0 $$ {\Delta E}_{00\left({R}_2\hbox{--} {R}_0\right)} $$ in Whiteness HP Blue (also Δ L 00 R 2 - R 0 $$ {\Delta L}_{00\left({R}_2\hbox{--} {R}_0\right)} $$ ) and Proxyt were also higher in comparison to the control group and in VS, Ceramisté decreased Δ L 00 R 1 - R 0 $$ {\Delta L}_{00\left({R}_1\hbox{--} {R}_0\right)} $$ , Δ E 00 R 1 - R 0 $$ {\Delta E}_{00\left({R}_1\hbox{--} {R}_0\right)} $$ , and Δ R T P 00 R 1 - R 0 $$ \varDelta RT{P}_{00\left({R}_1\hbox{--} {R}_0\right)} $$ , whereas Opalescence PF increased ΔRTP 00 R 1 - R 0 $$ {\Delta \mathrm{RTP}}_{00\left({R}_1\hbox{--} {R}_0\right)} $$ . Δ E 00 R 2 - R 0 $$ {\Delta E}_{00\left({R}_2\hbox{--} {R}_0\right)} $$ of Ceramisté and ΔWI D R 2 - R 0 $$ {\Delta \mathrm{WI}}_{\mathrm{D}\left({R}_2\hbox{--} {R}_0\right)} $$ and Δ R T P 00 R 2 - R 0 $$ \varDelta RT{P}_{00\left({R}_2\hbox{--} {R}_0\right)} $$ of Proxyt were lower than those of the control group. CONCLUSIONS: The most suitable treatment to recover the lightness, color, whiteness, and RTP without changing these properties after another coffee exposure is material-dependent. CLINICAL SIGNIFICANCE: Although the effectiveness of the treatment was material-dependent, Proxyt was the only treatment that promoted clinically acceptable changes for both LU and VE, while for purely ceramic materials, this condition was observed with Ceramisté and Clinpro Prophy Powder.
RESUMEN
A technique is outlined for utilising a polymeric composite reinforced with glass fibres in a three-dimensional mesh as a post-core in aesthetic cases. The clinical procedure involves obtaining an impression of the root canal space, scanning the definitive cast, and milling a fibre-reinforced composite post-core. Subsequently, the intra-radicular post-core is cemented using an adhesive resin cement. The use of custom-made computer-aided design-computer-aided manufacturing (CAD-CAM) fibre-reinforced composite post-core facilitates repairability, provides better adaptation to the root canal space, avoids uneven cement thickness, ensures chemical adhesion to resin cement, and promotes favourable aesthetics when combined with all-ceramic crowns.
Asunto(s)
Resinas Compuestas , Diseño Asistido por Computadora , Diseño de Prótesis Dental , Vidrio , Técnica de Perno Muñón , Humanos , Resinas Compuestas/química , Vidrio/química , Cementos de Resina/química , Coronas , Estética Dental , Retención de Prótesis Dentales , Materiales Dentales/química , CementaciónRESUMEN
Severe tooth wear is related to substantial loss of tooth structure, with dentin exposure and significant loss (≥1/3) of the clinical crown. The objective of this systematic review was to summarize and analyze the scientific evidence regarding the mechanical performance of computer-aided design/computer-aided manufacturing (CAD/CAM) composite resin and CAD/CAM lithium disilicate ceramic occlusal veneers, in terms of fatigue and fracture resistance, on severely worn posterior teeth. Currently, occlusal veneers are an alternative for treating worn posterior teeth. Although scientific evidence demonstrates the good performance of lithium disilicate occlusal veneers, there are less brittle materials with a modulus of elasticity more similar to dentin than ceramics, such as resin CAD/CAM blocks. Therefore, it is important to identify which type of material is best for restoring teeth with occlusal wear defects and which material can provide better clinical performance. This review was conducted in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. A comprehensive search of the PubMed, Embase, Web of Science, Scopus, Cochrane, OpenGrey, Redalyc, DSpace, and Grey Literature Report databases was conducted and supplemented by a manual search, with no time or language limitations, until January 2022. We aimed to identify studies evaluating the fatigue and fracture resistance of CAD/CAM composite resin and ceramic occlusal veneers. The quality of the full-text articles was evaluated according to the modified Consolidated Standards of Reporting Trials (CONSORT) criteria for in vitro studies, and 400 articles were initially identified. After removing duplicates and applying the selection criteria, 6 studies were included in the review. The results demonstrated that the mechanical performance of CAD/CAM composite resin occlusal veneers is comparable to that of CAD/CAM lithium disilicate occlusal veneers in terms of fatigue and fracture resistance.
Asunto(s)
Cerámica , Resinas Compuestas , Diseño Asistido por Computadora , Coronas con Frente Estético , Humanos , Porcelana Dental , Fracaso de la Restauración Dental , Desgaste de los Dientes/etiología , Desgaste de los Dientes/terapiaRESUMEN
Although advancements in CAD/CAM technology allow for more personalized treatments, it is not clear how modifications in the CAD/CAM milling process could affect the restoration surface conditions and their mechanical behavior. The objective of this study was to evaluate the effect of different CAD/CAM milling protocols on the topography and fracture behavior of zirconia monolithic crowns (3Y-PSZ) subjected to a chewing simulation. Monolithic 3Y-PSZ premolar crowns were milled using three protocols (n = 13) (slow (S), normal (N), and fast (F)). Crowns were cemented on a dentin analog abutment and subjected to mechanical aging (200 N, 2 Hz, 1,500,000 cycles, 37 °C water). Surviving crowns were subjected to compressive load test and analyzed using fractography. Fracture load data were analyzed with two-parameter Weibull analysis. The surface topography of the crowns was examined with a stereomicroscope and a 3D non-contact profiler. All crowns survived the chewing simulation. Crowns milled using the F protocol had the greatest characteristic fracture load, while crowns produced with the S protocol showed high Weibull modulus. Groups N and S had a more uniform surface and detailed occlusal anatomy than group F. The CAD/CAM milling protocol affected the topography and mechanical behavior of 3Y-PSZ monolithic crowns.
RESUMEN
OBJECTIVES: Evaluate the efficacy of denture cleaners on the adhesion of Candida albicans and their effects on the surface, optical, and mechanical properties of resins for conventional, milled, and 3D-printed denture bases. MATERIALS AND METHODS: A total of 240 resin samples were made, 120 for testing Candida albicans adhesion, optical stabilities (ΔE00), roughness (Ra), hydrophilicity (°), surface free energy (Owens-Wendt) and 120 samples for testing Candida albicans adhesion, surface microhardness (Knoop), flexural strength and modulus of elasticity in a three-point test, in which they were divided into 3 groups of denture resin (n = 40) and subdivided into 5 cleaners of dentures (n = 8). Data were evaluated by two-way ANOVA and Tukey's test for multiple comparisons (α = 0.05). RESULTS: Denture cleaners with an alkaline solution and dilute acid composition were those that showed the greatest effectiveness in reducing Candida albicans (P < 0.001), however 1% NaOCl significantly affected the properties of the resins (P < 0.05). Denture 3D-printed showed that the surface microhardness was significantly lower for all cleansers (P < 0.05). CONCLUSIONS: Listerine demonstrated superior efficacy in reducing Candida albicans with minimal effect on denture properties, whereas 1% NaOCl had a significant negative impact on the properties. The mechanical properties were significantly lower in 3D-printed resin than in other resins for all denture cleansers. CLINICAL RELEVANCE: Denture base materials are being sold to adapt to the CAD/CAM system, increasing the number of users of dentures manufactured with this system. Despite this, there is little investigation into denture cleaners regarding the adhesion capacity of microorganisms and the optical, surface and mechanical properties of dentures, thus requiring further investigation.
Asunto(s)
Candida albicans , Diseño Asistido por Computadora , Bases para Dentadura , Limpiadores de Dentadura , Ensayo de Materiales , Impresión Tridimensional , Propiedades de Superficie , Candida albicans/efectos de los fármacos , Bases para Dentadura/microbiología , Limpiadores de Dentadura/farmacología , Dureza , Resistencia Flexional , Materiales Dentales/químicaRESUMEN
OBJECTIVES: The purpose of this scoping review was to identify different methods employed for recording the maxillomandibular relationship (MMR) for computer-aided designed and manufactured (CAD-CAM) complete dentures (CDs). MATERIALS AND METHODS: This scoping review followed the PRISMA-ScR guidelines and was developed according to Arksey and O'Malley and The Joanna Briggs Institute protocol. The methods were registered on the Open Science Framework (< osf.io/rf4xm> ). The focus question was: "What are the different techniques for recording the maxillomandibular relationship in the digital workflow used in CECDs?" Two investigators searched 3 online databases [MEDLINE (PubMed), Scopus, and Science Direct] independently. The inclusion criteria were clinical studies and reviews that assessed techniques for recording MMR using digital workflow for manufacturing of CECDs. A descriptive analysis was performed considering the study design, manufacturing system, clinical steps, and tools for the determination of MMR, and the difficulty level of procedures. RESULTS: 4779 articles were identified in the electronic search and 10 studies were included for data analysis. The review identified 4 commercially available CAD-CAM denture systems and 3 innovative methods suitable for abbreviating the number of appointments (2 to 4 visits). The trial denture is inherent to the procedure for the Baltic System and 3 innovative techniques. Three techniques (2 innovative and WholeYouNexteeth) demonstrated lower difficulty levels for performing the clinical procedures, regardless of the professional skills. CONCLUSIONS: The commercially available and innovative techniques for the recording of MMR may provide predictability of the treatment. The techniques are effective, however, rely on the learning curve and the patient's clinical condition. CLINICAL RELEVANCE: Recording of the maxillomandibular relationship is paramount for the manufacturing and functionality of complete dentures. Clinicians should be aware of the different tools and techniques described for registering the jaw relationship.
Asunto(s)
Diseño Asistido por Computadora , Diseño de Dentadura , Dentadura Completa , Humanos , Diseño de Dentadura/métodos , Registro de la Relación Maxilomandibular/métodosRESUMEN
The aim of this in vitro study is to compare the performance of digital and conventional methods in the manufacture of single copings in terms of the internal and marginal fit. Twenty-four prefabricated titanium Cone Morse Exact abutments of the lateral anatomical type were used to manufacture 24 lithium disilicate copings in the CAD-CAM Ceramill (n = 12) and heat-press (n = 12) systems. The copings were cemented using a self-adhesive resin cement (RelyX U-200; 3M ESPE) and then cut vertically. The cement line was photographed using an optical microscope at ×100 and ×200 magnification and then the internal and marginal regions were measured. The mean values of fits, for the CAD-CAM and heat-press techniques, respectively, were (µm): angular regions, 81.8 and 75.3; linear regions, 63.1 and 60.1; incisal regions, 171.1 and 114.7; marginal discrepancy, 74.1 and 75.2; and absolute marginal discrepancy, 99.5 and 96.2. MANOVA test showed that there is an effect of the techniques on the regions (p < .05). The effects of laboratories and the interaction between laboratories and techniques on the regions were not statistically significant (p > .05). The techniques evaluated presented clinically acceptable results for the marginal fit. However, the conventional method performed better for the internal fit. RESEARCH HIGHLIGHTS: Scientific evidence regarding the methods of making prosthesis can help the dental professional in decision-making. Digital and conventional methods is both good in the manufacture of single copings in terms of the internal and marginal fit.
RESUMEN
The present work aims to develop a production method of pre-sintered zirconia-toughened-alumina (ZTA) composite blocks for machining in a computer-aided design and computer-aided manufacturing (CAD-CAM) system. The ZTA composite comprised of 80% Al2O3 and 20% ZrO2 was synthesized, uniaxially and isostatically pressed to generate machinable CAD-CAM blocks. Fourteen green-body blocks were prepared and pre-sintered at 1000 °C. After cooling and holder gluing, a stereolithography (STL) file was designed and uploaded to manufacture disk-shaped specimens projected to comply with ISO 6872:2015. Seventy specimens were produced through machining of the blocks, samples were sintered at 1600 °C and two-sided polished. Half of the samples were subjected to accelerated autoclave hydrothermal aging (20h at 134 °C and 2.2 bar). Immediate and aged samples were characterized by scanning electron microscopy (SEM) and X-ray diffraction (XRD). Optical and mechanical properties were assessed by reflectance tests and by biaxial flexural strength test, Vickers indentation and fracture toughness, respectively. Samples produced by machining presented high density and smooth surfaces at SEM evaluation with few microstructural defects. XRD evaluation depicted characteristic peaks of alpha alumina and tetragonal zirconia and autoclave aging had no effect on the crystalline spectra of the composite. Optical and mechanical evaluations demonstrated a high masking ability for the composite and a characteristic strength of 464 MPa and Weibull modulus of 17, with no significant alterations after aging. The milled composite exhibited a hardness of 17.61 GPa and fracture toughness of 5.63 MPa m1/2, which remained unaltered after aging. The synthesis of ZTA blocks for CAD-CAM was successful and allowed for the milling of disk-shaped specimens using the grinding method of the CAD-CAM system. ZTA composite properties were unaffected by hydrothermal autoclave aging and present a promising alternative for the manufacture of infrastructures of fixed dental prostheses.
Asunto(s)
Óxido de Aluminio , Cerámica , Ensayo de Materiales , Óxido de Aluminio/química , Cerámica/química , Propiedades de Superficie , Circonio/química , Diseño Asistido por Computadora , Materiales DentalesRESUMEN
OBJECTIVES: This study aimed to assess the influence of translucent monolithic versus bilayered crowns and whether the use of a CoCr base abutments affects the fatigue and fracture resistance of screwed implant-supported single crowns with external connections under mechanical cycling. MATERIALS AND METHODS: Fifty specimens were divided into groups: (1) metal-ceramic (MC) crown, (2) veneered zirconia crown (Zr), (3) veneered zirconia crown with a CoCr base abutment (ZrB), (4) monolithic translucent zirconia crown (MZr), and (5) monolithic translucent zirconia crown with a CoCr base abutment (MZrB). Specimens underwent mechanical cycling (5 × 106 cycles; 150 N) evaluating fatigue resistance (number of failures) and those that failed were subsequently subjected to fractographic analyses (stereomicroscope and scanning electron microscope) to evaluate failure location and area, and maximum fracture load was also measured. RESULTS: The failure-related survival rate (100%) and maximum fracture resistance of the MZrB were significantly higher than those of MC and Zr (50%; p < 0.05). There were no significant differences in the failure rate and fracture resistance when a CoCr base abutment was used or not in the translucent monolithic Zr groups (p > 0.05;MZrB vs. MZr). Failure location, with MC crowns' fractures, noted at the screw area (p = 0.043), while all-ceramic crowns were mostly in the cuspid and to failure area, the Zr group had the largest mean (15.55 ± 9.17 mm2) among the groups, significant difference only when compared with MC (1.62 ± 0.81 mm2) (p = 0.025). CONCLUSIONS: Translucent monolithic zirconia crowns exhibited significantly higher fatigue and fracture resistance compared with conventional MC and bilayered crowns. CLINICAL SIGNIFICANCE: The appropriate choice of material and manufacturing technique is crucial for predicting the higher clinical performance of single crowns. Enhanced mechanical resistance in terms of fatigue and fracture resistance can be achieved by replacing MC and bilayered restorations with computer-aided design and computer-aided manufacturing monolithic zirconia.
Asunto(s)
Coronas , Análisis del Estrés Dental , Circonio , Circonio/química , Cerámica/química , Diseño de Prótesis Dental , Fracaso de la Restauración Dental , Prótesis Dental de Soporte Implantado , Ensayo de Materiales , HumanosRESUMEN
Abstract The purpose of this study was to examine the effect of different decontamination agents on the bond strength of saliva-contaminated CAD/CAM blocks and repair composite materials. Two hunderd eighty 3-mm-thick specimens were prepared from four different CAD/CAM materials: Katana Zirconia UTML disc, IPS e.max CAD block, Shofu block, and Vita Enamic block. Each material was divided into seven different subgroups (N=70). Group 1 had a clean surface. The other groups were comprised of the samples, which were contaminated with human saliva: group 2: negative control (non-cleaned); group 3: cleaned with water spray; group 4: cleaned with 70% ethanol; group 5: cleaned with Ivoclean; group 6: cleaned with Katana Cleaner; and group 7: cleaned with phosphoric acid. After the decontamination protocols, the resin composite cylinders were bonded to the CAD/CAM surfaces with a thin layer of dual-cured resin cement. The samples were stored for 24 hours at 37°C in distilled water. Then, they were subjected to a shear bond strength test (SBS). The values were recorded, and fracture types were evaluated using a microscope. Data were analyzed using two-way ANOVA and Tukey's post-hoc test. Generally, all decontaminating agents improved the SBS of composites to Katana Zirconia UTML, IPS e.max, and Vita Enamic materials (p<0.05). However, for Shofu materials, group 6 samples exhibited significantly higher bond strength values as compared with group 2 samples (p=0.026). The highest SBS values were seen in the phosphoric acid-treated group in Katana zirconia materials (26.45 ± 9.38 MPa), whereas the lowest values were seen in group 2 samples in Shofu materials (13.17±3.40 MPa). Each decontaminant agent improved the bond strength of composites to the contaminated CAD/CAM materials. If saliva is not cleaned before adhesive procedure, SBS values may decrease. All decontamination agents can be used safely on zirconia, lithium-disilicate glass-ceramic, hybrid ceramic, and polymer-infiltrated ceramic surfaces.
Resumen El propósito de este estudio fue examinar el efecto de diferentes agentes descontaminantes sobre la fuerza de unión de bloques CAD/CAM contaminados con saliva y materiales compuestos de reparación. Se prepararon doscientas ochenta muestras de 3 mm de espesor a partir de cuatro materiales CAD/CAM diferentes: disco Katana Zirconia UTML, bloque IPS e.max CAD, bloque Shofu y bloque Vita Enamic. Cada material se dividió en siete subgrupos diferentes (N=70). El grupo 1 tenía una superficie limpia. Los otros grupos estaban compuestos por muestras que estaban contaminadas con saliva humana: grupo 2: control negativo (no limpio); grupo 3: limpiado con agua pulverizada; grupo 4: limpiado con etanol al 70%; grupo 5: limpiado con Ivoclean; grupo 6: limpiado con Katana Cleaner; y grupo 7: limpiado con ácido fosfórico. Después de los protocolos de descontaminación, los cilindros de composite de resina se adhirieron a las superficies CAD/CAM con una fina capa de cemento de resina de curado dual. Las muestras se almacenaron durante 24 horas a 37°C en agua destilada. Luego, fueron sometidos a una prueba de resistencia al corte (SBS). Se registraron los valores y se evaluaron los tipos de fracturas utilizando un microscopio. Los datos se analizaron mediante ANOVA de dos factores y la prueba post-hoc de Tukey. En general, todos los agentes descontaminantes mejoraron el SBS de los composites con los materiales Katana Zirconia UTML, IPS e.max y Vita Enamic (p<0,05). Sin embargo, para los materiales Shofu, las muestras del grupo 6 exhibieron valores de fuerza de unión significativamente más altos en comparación con las muestras del grupo 2 (p=0,026). Los valores más altos de SBS se observaron en el grupo tratado con ácido fosfórico en materiales de circonio Katana (26,45 ± 9,38 MPa), mientras que los valores más bajos se observaron en las muestras del grupo 2 en materiales Shofu (13,17 ± 3,40 MPa). Cada agente descontaminante mejoró la fuerza de unión de los composites a los materiales CAD/CAM contaminados. Si no se limpia la saliva antes del procedimiento adhesivo, los valores de SBS pueden disminuir. Todos los agentes descontaminantes se pueden utilizar de forma segura en superficies de circonio, cerámica de vidrio de disilicato de litio, cerámica híbrida y cerámica con infiltraciones de polímeros.