Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Más filtros











Intervalo de año de publicación
1.
J Esthet Restor Dent ; 33(3): 487-495, 2021 04.
Artículo en Inglés | MEDLINE | ID: mdl-32937028

RESUMEN

OBJECTIVE: To evaluate, through microcomputed tomography (µCT), the cement film thickness of veneers and crowns made with different provisional materials. MATERIAL AND METHODS: A veneer and a crown preparation were performed on a central incisor and a second molar of a dental model, respectively, scanned with an intraoral scanner, and the .stl files were exported to an LCD-based SLA three-dimensional (3D)-Printer. Twenty-four preparations were 3D-printed for each veneer and crown and divided into four groups (n = 6/group): (a) Acrylic resin (Acrílico Marche); (b) Bisacrylic resin (Protemp 4); (c) PMMA computer-aided design and computer-aided manufacturing (CAD-CAM) (Vipiblock); and (d) 3D-printed resin for provisional restorations (Raydent C&B for temporary crown and bridge). Veneers and crowns restorations were performed and cemented with a flowable composite. Each specimen was scanned with a µCT apparatus, files were imported for data analysis, and cement film thickness was quantitatively measured. Data were analyzed by 2-way ANOVA and Tukey post-hoc tests (α = .05). RESULTS: Crowns presented a thicker cementation film than veneers (P < .05).The bisacrylic resin showed the smallest veneer film thickness, similar to the acrylic resin (P = .151), which was not significantly different than the PMMA CAD/CAM material (P = .153). The 3D printed provisional material showed the thicker film, different than all other materials (P < .05). The bisacrylic resin showed a cement film thickness with a high number of voids in its surface. For crowns cementation, the 3D printed provisional material showed the thicker cementation film, different than all other materials (P < .05). CONCLUSIONS: Different provisional materials present different film thicknesses. The 3D printed provisional material showed the highest veneer and crown film thicknesses. Veneers film thicknesses were smaller than crowns for all provisional materials. CLINICAL SIGNIFICANCE: The 3D printed provisional material studied can be satisfactorily used, presenting appropriate adaptation with the tooth preparation, however, it shows the highest cement film thickness for both veneers and crowns cementations when compared with other provisional materials. A better internal fit, or smaller cement film thickness is obtained by CAD/CAM materials, acrylic and bisacrylic resins. Veneer cementation showed a smaller cement film thickness compared with crown cementation for all provisional materials.


Asunto(s)
Coronas , Porcelana Dental , Diseño Asistido por Computadora , Materiales Dentales , Diseño de Prótesis Dental , Ensayo de Materiales , Impresión Tridimensional , Cementos de Resina , Microtomografía por Rayos X
2.
Braz. dent. j ; Braz. dent. j;30(5): 459-466, Sept.-Oct. 2019. tab, graf
Artículo en Inglés | LILACS | ID: biblio-1039139

RESUMEN

Abstract The aim of this study was to evaluate of pre-heating, filler contents and ceramic thickness on film thickness, microshear bond strength, degree of conversion and color change on ceramic veneers. Two experimental composites were prepared (Bis-GMA/UDMA/BisEMA/ TEGDMA), with different amounts of filler (65% or 50%wt) simulating a conventional and a flowable composite. The flowable (F) was used at room temperature and, the conventional either at room temperature (C) or pre-heated (CPH). Disk-shaped ceramics with different thickness (0.4 mm, 0.8 mm, 1.5 mm) were prepared. The film thickness was evaluated according to the ISO 4049 (n=10). The microshear bond strength (n=10) was evaluated in enamel using tubing specimens light-cured through the ceramic veneer. The degree of conversion was evaluated using Raman spectroscopy. The color change of the ceramic restorations (n=10) was evaluated by spectrophotometry. The results were submitted to 2-way ANOVA and Tukey's post hoc test (a=5%). For the film thickness 1-way ANOVA was used (a=5%). The C presented the thicker film thickness; the CPH produced a similar film thickness in comparison to the F. All composites showed similar microshear bond strength. The degree of conversion of the F was higher than the C and CPH. The degree of conversion of the composites photo-activated through a 0.4 mm was higher than the composites photo-activated through thicker ceramics. The C showed the highest color change, while the CPH showed similar color change to the F. In conclusion, pre-heated conventional composites seem to be a potential alternative to lute ceramic veneers such as the flowable composites.


Resumo O objetivo neste estudo foi avaliar a influência do pré-aquecimento, conteúdo de carga e espessura da cerâmica na espessura da película, resistência de união ao microcisalhamento, grau de conversão e alteração de cor na cimentação de cerâmicas. Dois compósitos experimentais foram preparados (Bis-GMA / UDMA / BisEMA / TEGDMA), com diferentes quantidades de carga (65% ou 50% em peso), simulando um compósito convencional e um fluido. O fluido (F) foi usado à temperatura ambiente e o convencional, à temperatura ambiente (C) ou pré-aquecido (CPH). Foram preparados discos de cerâmica com diferentes espessuras (0,4mm, 0,8mm, 1,5mm). A espessura da película foi avaliada de acordo com a ISO 4049 (n=10). A resistência de união ao microcisalhamento (n=10) foi avaliada em esmalte utilizando espécimes ​​fotopolimerizados através da cerâmica. O grau de conversão foi avaliado usando espectroscopia Raman. A alteração de cor das restaurações cerâmicas (n=10) foi avaliada por espectrofotometria. Os resultados foram submetidos à ANOVA 2- fatores e ao teste post hoc de Tukey (a=5%). Para espessura de película foi utilizada a ANOVA 1-fator (a=5%). O grupo C apresentou maior espessura de película; o CPH produziu uma espessura semelhante ao F. Todos os compósitos mostraram resistência de união ao microcisalhamento similares. O grau de conversão do F foi maior que C e CPH. O grau de conversão dos compósitos fotoativados através 0,4 mm foi maior que dos compósitos fotoativados através de cerâmicas mais espessas. O grupo C apresentou a maior mudança de cor, enquanto o CPH apresentou mudança de cor semelhante ao F. Em conclusão, compósitos convencionais pré-aquecidos assim como compósitos fluídos, parecem ser uma alternativa em potencial para cimentar laminados cerâmicos.


Asunto(s)
Cementos de Resina , Coronas con Frente Estético , Ensayo de Materiales , Cerámica , Resinas Compuestas , Porcelana Dental , Calefacción
3.
Dent Mater ; 35(10): 1430-1438, 2019 10.
Artículo en Inglés | MEDLINE | ID: mdl-31387743

RESUMEN

OBJECTIVE: This study evaluated the influence of preheating different composite resins on their viscosity and strengthening yielded to ceramic. METHODS: Modulus of elasticity, Poisson's ratio, and degree of CC conversion were measured for three restorative composite resins (Z100-microhybrid; Empress Direct-nanohybrid; Estelite Omega-supranano) and one photoactivated resin cement (RelyX Veneer). Viscosity was measured during a heating-cooling curve (25°C-69°C-25°C) and also using isothermal analyses at 25°C and 69°C. Feldspar ceramic disks simulating veneers were bonded with the luting materials. Biaxial flexural strength, characteristic strength, and Weibull modulus were calculated at axial positions (z=0 and z=-t2) of the bilayers. Film thickness was measured and morphology at the bonded interfaces was observed. Data were statistically analyzed (α=0.05). RESULTS: A gradual decrease in viscosity was noticed as the rheometer temperature gradually increased. Viscosity differences between the composite resins were large at the beginning of the analysis, but minor at 69°C. At 25°C, the composites were up to 38 times more viscous than the resin cement; at 69°C the difference was 5-fold. CC conversion was similar between all resin-based agents. The resin cement yielded lower film thickness than the composites. All resin-based agents were able to infiltrate the ceramic porosities at the interface and strengthen the ceramic. However, the magnitude of the strengthening effect was higher for the preheated composite resins, particularly at z=-t2. SIGNIFICANCE: Selection of composite resin impacts its response to preheating and the resulting viscosity, film thickness, and magnitude of ceramic strengthening.


Asunto(s)
Cerámica , Resinas Compuestas , Silicatos de Aluminio , Porcelana Dental , Ensayo de Materiales , Compuestos de Potasio , Cementos de Resina , Propiedades de Superficie
4.
Braz. dent. j ; Braz. dent. j;30(4): 350-355, July-Aug. 2019. tab, graf
Artículo en Inglés | LILACS | ID: biblio-1011562

RESUMEN

Abstract The aim of this study was to evaluate the effect of different glass fiber posts (GFPs) diameters on the push-out bond strength to dentin. Forty unirradicular human teeth were endodontically treated and used for cementation of GFPs (White Post DC, FGM) with different diameters (n=10): P1 - ø 1.6 mm coronal x 0.85 mm apical; P2 - ø 1.8 mm coronal x 1.05 mm apical; P5 - ø 1.4 mm coronal x 0.65 mm apical; and PC - customized post number 0.5 with composite resin (Tetric Ceram A2, Ivoclair Vivadent). All GFPs were cemented into the root canal using a dual-curing luting composite (Variolink II, Ivoclar Vivadent). One slice (1.7 mm) of each root third of cemented GFP (cervical, middle, and apical) was submitted to push-out testing. Failure modes of all specimens were classified as: adhesive failure between resin cement and post; adhesive failure between dentin and resin cement; cohesive failure within resin cement, post or dentin; and mixed failure. The data were analyzed with two-way ANOVA and Tukey's test (a=0.05). The highest bond strength values were presented for the P2 and PC groups. There was no statistically significant difference between the GFP thirds in each group. The groups P2, P5, and PC showed predominantly adhesive failure. For P1, the most prevalent type of failure was adhesive between resin cement and post. It may be concluded that a glass fiber post that is well adapted to the root canal presents higher bond strength values, regardless of GFP third.


Resumo O objetivo neste estudo foi avaliar o impacto de diferentes diâmetros de pinos de fibra de vidro (PFVs) na resistência de união à dentina. Quarenta dentes humanos unirradiculares foram tratados endodonticamente e utilizados para cimentação de PFVs (White Post DC, FGM) com diferentes diâmetros (n=10): P1 - ø 1,6 mm coronal x 0,85 mm apical; P2 - ø 1,8 mm coronal x 1,05 mm apical; P5 - ø 1,4 mm coronal x 0,65 mm apical; e PC - pino número 0,5 individualizado com resina composta (Tetric Ceram A2, Ivoclair Vivadent). Todos os PFVs foram cimentados no canal radicular usando cimento resinoso dual (Variolink II, Ivoclar Vivadent). As raízes foram seccionadas em três secções (cervical, média e apical) e submetidas ao teste push-out. Os modos de falha de todos os espécimes foram classificados em falha adesiva entre o cimento resinoso e pino, falha adesiva entre dentina e cimento resinoso, falha coesiva no cimento resinoso, pino ou dentina e falha mista. Os dados foram analisados ​​com ANOVA two-way e teste de Tukey (a=0,05). Os maiores valores de resistência da união foram apresentados para os grupos P2 e PC. Não houve diferença estatisticamente significante entre os terços dos PFVs cimentados na raiz para cada grupo. Os grupos P2, P5 e PC apresentaram predominantemente falha adesiva entre a dentina e o cimento resinoso. Para o grupo P1, o tipo de falha mais prevalente foi a adesiva entre cimento resinoso e pino. Pode-se concluir que o pino de fibra de vidro bem adaptado ao canal radicular apresentou os maiores valores de resistência da união, independentemente do terço dos PFVs.


Asunto(s)
Humanos , Técnica de Perno Muñón , Recubrimiento Dental Adhesivo , Ensayo de Materiales , Cementos de Resina , Cavidad Pulpar , Dentina , Vidrio
5.
Materials (Basel) ; 9(1)2016 Jan 08.
Artículo en Inglés | MEDLINE | ID: mdl-28787833

RESUMEN

The influence of the thickness of the nanostructured, mesoporous TiO2 film on several parameters determining the performance of a dye-sensitized solar cell is investigated both experimentally and theoretically. We pay special attention to the effect of the exchange current density in the dark, and we compare the values obtained by steady state measurements with values extracted from small perturbation techniques. We also evaluate the influence of exchange current density, the solar cell ideality factor, and the effective absorption coefficient of the cell on the optimal film thickness. The results show that the exchange current density in the dark is proportional to the TiO2 film thickness, however, the effective absorption coefficient is the parameter that ultimately defines the ideal thickness. We illustrate the importance of the exchange current density in the dark on the determination of the current-voltage characteristics and we show how an important improvement of the cell performance can be achieved by decreasing values of the total series resistance and the exchange current density in the dark.

6.
Clin Oral Investig ; 20(4): 849-55, 2016 May.
Artículo en Inglés | MEDLINE | ID: mdl-26319977

RESUMEN

OBJECTIVES: This study compared the influence of cement film thickness (CFT) on bond strength (BS) and fracture resistance (FR) of fiber-reinforced composite (FRC) posts to root canal. MATERIALS AND METHODS: One hundred bovine incisors were used for BS and FR analysis (n = 10) and distributed into five experimental groups according to FRC post diameters (WhitePost DC no. 0.5, no. 1, no. 2, no. 3, no. 4), leading to five different CFTs. The canals were prepared using drill no. 4 provided by the post manufacturer and irrigated with 2.5% NaOCl. After conditioning (24% H2O2/5 min) and silanization, posts were cemented with resin cement. BS was evaluated using push-out test and FR using the compression test at 45°. A stereomicroscope was used to measure CFT and to analyze failure pattern. BS data were subjected to two-way ANOVA and Scheffé test for contrast (α = 0.05); FR data were subjected to one-way ANOVA. RESULTS: BS was significantly affected by CFT, as the most well-adapted post achieved the highest values (p < 0.05). BS was similar for all root thirds. CFT did not affect fracture resistance. No root fractures were observed. CONCLUSIONS: A FRC post well adapted to the root canal results in higher BS values. Different CFTs did not influence the FR of teeth restored with FRC posts. CLINICAL RELEVANCE: The results indicate that post retention is improved when a well-adapted post is used, although this has not been critical to fracture resistance.


Asunto(s)
Resinas Compuestas , Técnica de Perno Muñón , Cementos de Resina , Animales , Bovinos , Cementos de Ionómero Vítreo , Peróxido de Hidrógeno , Ensayo de Materiales
7.
Biochim Biophys Acta ; 1838(3): 731-8, 2014 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-24315999

RESUMEN

Unique species of ceramide (Cer) with very-long-chain polyunsaturated fatty acid (VLCPUFA), mainly 28-32 carbon atoms, 4-5 double bonds, in nonhydroxy and 2-hydroxy forms (n-V Cer and h-V Cer, respectively), are generated in rat spermatozoa from the corresponding sphingomyelins during the acrosomal reaction. The aim of this study was to determine the properties of these sperm-distinctive ceramides in Langmuir monolayers. Individual Cer species were isolated by HPLC and subjected to analysis of surface pressure, surface potential, and Brewster angle microscopy (BAM) as a function of molecular packing. In comparison with known species of Cer, n-V Cer and h-V Cer species showed much larger mean molecular areas and increased molecular dipole moments in liquid expanded phases, which suggest bending and partial hydration of the double bonded portion of the VLCPUFA. The presence of the 2-hydoxyl group induced a closer molecular packing in h-V Cer than in their chain-matched n-V Cer. In addition, all these Cer species showed liquid-expanded to liquid-condensed transitions at room temperature. Existence of domain segregation was confirmed by BAM. Additionally, thermodynamic analysis suggests a phase transition close to the physiological temperature for VLCPUFA-Cers if organized as bulk dispersions.


Asunto(s)
Ceramidas/química , Ceramidas/metabolismo , Ácidos Grasos Insaturados/metabolismo , Espermatozoides/metabolismo , Animales , Cromatografía Líquida de Alta Presión , Ácidos Grasos Insaturados/química , Masculino , Transición de Fase , Ratas , Propiedades de Superficie , Termodinámica
8.
Eur J Dent ; 7(4): 474-483, 2013 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-24932124

RESUMEN

OBJECTIVES: The objective of this study is to evaluate, in vitro, the thickness of immediate dentin sealing (IDS) materials on full crown preparations and its effect on the fracture load of a reinforced all-ceramic crown. MATERIALS AND METHODS: SIXTY PREMOLARS RECEIVED FULL CROWN PREPARATION AND WERE DIVIDED INTO THE FOLLOWING GROUPS ACCORDING TO THE IDS TECHNIQUE: G1-control; G2-Clearfil SE Bond; and G3-Clearfil SE Bond and Protect Liner F. After the impressions were taken, the preparations were temporized with acrylic resin crowns. IPS empress 2 restorations were fabricated and later cemented on the preparations with Panavia F. 10 specimens from each group were submitted to fracture load testing. The other 10 specimens were sectioned buccolingually before the thicknesses of Panavia F, Clearfil SE Bond and Protect Liner F were measured in 10 different positions using a microscope. RESULTS: According to analysis of variance and Tukey's test, the fracture load of Group 3 (1300 N) was significantly higher than that of Group 1 (1001 N) (P < 0.01). Group 2 (1189 N) was not significantly different from Groups 1 and 3. The higher thickness of Clearfil SE Bond was obtained in the concave part of the preparation. Protect Liner F presented a more uniform range of values at different positions. The thickness of Panavia F was higher in the occlusal portion of the preparation. CONCLUSIONS: The film thickness formed by the IDS materials is influenced by the position under the crown, suggesting its potential to increase the fracture load of the IPS empress 2 ceramic crowns.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA