1.
An Bras Dermatol ; 2024 Aug 05.
Artículo en Inglés | MEDLINE | ID: mdl-39107199

RESUMEN

Excimer light is a subtype of NB-UVB that emits a 308 nm wavelength, and can provide targeted phototherapy treatment. The absorption of 308 nm light by skin cells leads to therapeutic response in various common and ultraviolet-responsive skin diseases, such as psoriasis and vitiligo, and photo-resistant skin diseases such as prurigo nodularis, localized scleroderma, genital lichen sclerosis, and granuloma annulare, cutaneous T-cell lymphomas, among others. Excimer light has few adverse reactions and overall is well tolerated by patients, furthermore, it can be performed in places that are difficult to access. This article aims to explain the therapeutic bases and applications of excimer light in current dermatology.

2.
Arq. bras. oftalmol ; Arq. bras. oftalmol;87(4): e2022, 2024. tab, graf
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1520241

RESUMEN

ABSTRACT Purpose: This study aimed to report an experiment designed to determine anatomical changes in porcine corneas following placement of a novel polymer implant into the cornea. Methods: An ex vivo porcine eye model was used. A novel type I collagen-based vitrigel implant (6 mm in diameter) was shaped with an excimer laser on the posterior surface to create three planoconcave shapes. Implants were inserted into a manually dissected stromal pocket at a depth of approximately 200 μm. Three treatment groups were defined: group A (n=3), maximal ablation depth 70 μm; Group B (n=3), maximal ablation depth 64 μm; and group C (n=3), maximal ablation depth 104 μm, with a central hole. A control group (D, n=3) was included, in which a stromal pocket was created but biomaterial was not inserted. Eyes were evaluated by optical coherence tomography (OCT) and corneal tomography. Results: Corneal tomography showed a trend for a decreased mean keratometry in all four groups. Optical coherence tomography showed corneas with implants placed within the anterior stroma and visible flattening, whereas the corneas in the control group did not qualitatively change shape. Conclusions: The novel planoconcave biomaterial implant described herein could reshape the cornea in an ex vivo model, resulting in the flattening of the cornea. Further studies are needed using in vivo animal models to confirm such findings.


RESUMO Objetivo: Relatar um experimento projetado para determinar alterações anatômicas em córneas porcinas após a colocação de um novo implante de polímero na córnea. Métodos: Foi utilizado olho de porco ex vivo. Um novo agente modelador biocompatível, de colágeno tipo 1, com 6mm de diâmetro foi moldado com excimer laser em sua face posterior, para criar três formatos planocôncavos. Os implantes foram inseridos dentro de um bolsão, dissecado manualmente, a 200 micrômetros (μm). Foram definidos três grupos de tratamento: grupo A (n=3), teve a profundidade máxima de ablação de 70 μm; o grupo B (n=3), profundidade máxima de ablação de 64 μm; e o grupo C (n=3), profundidade máxima de ablação de 104 μm, com buraco central. O grupo controle, D (n=3), foi incluído, com a criação do bolsão estromal, porém sem inserir o material. A avaliação desses olhos foi realizada por tomografia de coerência óptica (OCT) e por tomografia corneana. Resultados: A tomografia corneana mostrou uma tendência para diminuição da ceratometria média em todos os 4 grupos. A tomografia de coerência óptica mostrou córneas com implantes localizados no estroma anterior e aplanamento visível, enquanto as córneas não mudaram qualitativamente o formato no grupo controle. Conclusões: O novo implante de biomaterial planocôncavo descrito aqui foi capaz de remodelar a córnea em modelo de animal ex vivo, resultando no aplanamento corneano. Novos estudos são necessários usando modelos animais in vivo para confirmar tais achados.

3.
Rev. bras. oftalmol ; 82: e0021, 2023. graf
Artículo en Portugués | LILACS-Express | LILACS | ID: biblio-1441325

RESUMEN

RESUMO O FemtoLasik é uma das técnicas mais empregadas em cirurgia refrativa, por seus bons resultados refracionais, sua previsibilidade, sua reprodutibilidade e sua segurança. Tem alto grau de satisfação, com rápida recuperação visual. Apesar de as taxas de complicações do FemtoLasik serem pequenas, intercorrências podem existir. O objetivo deste trabalho foi relatar um caso de uma complicação na dissecção da lamela por Lasik com laser de femtossegundo com consequente rasgadura da lamela, sendo aplicado Excimer Laser com mitomicina C 0,02%. O retratamento foi realizado com ablação de superfície (ceratectomia fotorrefrativa) guiada por frente de onda, evoluindo com boa qualidade visual final.


ABSTRACT Femtolasik is one of the most used techniques in refractive surgery due to good refractive results, predictability, reproducibility, and safety, achieving excellent results and a high degree of satisfaction. Although the complication rates are small, it is worth noting that there may be intercurrences. The objective of this work is to report a case of complication in the dissection of the lamella of laser in situ keratomileusis (Lasik) with Femtosecond laser, and subsequent lamella tear. Excimer Laser was applied with mitomycin 0.02% and re-approached with wavefront guided surgery, evolving with good final visual quality.

4.
J. Transcatheter Interv ; 30: eA20220012, 20220101. ilus
Artículo en Inglés, Portugués | LILACS-Express | LILACS | ID: biblio-1401756

RESUMEN

A aterectomia coronária com Excimer Laser melhorou significativamente nos últimos anos, utilizando emissão ultravioleta de alta energia e comprimento de onda curto, com menor penetração e menor emissão de calor, resultando em menos danos aos tecidos e menos complicações. Descrevemos o caso de um paciente do sexo masculino, 66 anos, ex-tabagista, hipertenso, diabético, dislipidêmico. Foi submetido a múltiplas intervenções coronárias percutâneas na artéria descendente anterior com stents não farmacológicos e farmacológicos. Na última intervenção coronária percutânea, o stent foi subexpandido, e o paciente apresentou trombose aguda do stent e reestenose recorrente do stent. Foram realizadas novas intervenções coronárias percutâneas com aterectomia coronária com Excimer Laser adjuvante, devido à angina refratária, com uso de carga progressiva e injeção de soro fisiológico, seguidas de posterior insuflação de balão de alta pressão e implante de stent farmacológico, com resultado excelente. No acompanhamento de 8 meses, o paciente se manteve assintomático.


Excimer Laser coronary atherectomy has improved significantly in recent years, emitting high-energy ultraviolet and short wavelength with less penetration and heat emission, ultimately leading to less tissue damage and fewer complications. We described a case of a 66-year-old male patient, former smoker and suffering from hypertension, diabetes mellitus, and dyslipidemia. He underwent multiple percutaneous coronary interventions in the left anterior descending artery with bare metal and drug-eluting stents. In the last percutaneous coronary intervention, the stent was underexpanded and the patient presented acute stent thrombosis and recurrent stent restenosis. New percutaneous coronary interventions with adjunctive Excimer Laser coronary atherectomy were undertaken due to refractory angina, using progressive load and saline injection, followed by subsequent high-pressure balloon inflation and drug-eluting stent implantation with an excellent result. At 8-month follow-up, the patient was asymptomatic.

5.
Med. UIS ; 30(1): 99-105, ene.-abr. 2017. graf
Artículo en Español | LILACS | ID: biblio-894197

RESUMEN

RESUMEN El auge de la cirugía refractiva con excimer láser en las últimas dos décadas se ha reflejado en que un grupo creciente de pacientes con antecedente de este procedimiento necesitan ahora cirugía de catarata. Debido a las modificaciones generadas en la córnea por la fotoablación con el láser, la determinación del poder corneal necesario para el cálculo del poder del lente intraocular a implantar en la cirugía de catarata, es difícil. Teniendo en cuenta estos aspectos se hace una revisión de las causas de estos errores de medición y los abordajes existentes para minimizar su impacto. MÉD.UIS. 2017;30(1):99-105.


ABSTRACT The rise of excimer laser refractive surgery in the last two decades has been reflected in a growing group of patients with a history of this procedure who now need cataract surgery. Because the generated modifications to the cornea with the laser photoablation, determining the corneal power, necessary for calculating the power of the intraocular lens to be implanted during the cataract surgery, is difficult. We review the causes of these errors of measurement and existing approaches to minimize its impact. MÉD.UIS. 2017;30(1):99-105.


Asunto(s)
Humanos , Láseres de Excímeros , Catarata , Queratectomía Fotorrefractiva , Córnea , Topografía de la Córnea , Lentes Intraoculares Multifocales
6.
Arq. bras. oftalmol ; Arq. bras. oftalmol;77(2): 103-109, Mar-Apr/2014. graf
Artículo en Inglés | LILACS | ID: lil-716254

RESUMEN

Purpose: To compare optical and visual quality of implantable collamer lens (ICL) implantation and femtosecond laser in situ keratomileusis (F-LASIK) for myopia. Methods: The CRX1 adaptive optics visual simulator (Imagine Eyes, Orsay, France) was used to simulate the wavefront aberration pattern after the two surgical procedures for -3-diopter (D) and -6-D myopia. Visual acuity at different contrasts and contrast sensitivities at 10, 20, and 25 cycles/degree (cpd) were measured for 3-mm and 5-mm pupils. The modulation transfer function (MTF) and point spread function (PSF) were calculated for 5-mm pupils. Results: F-LASIK MTF was worse than ICL MTF, which was close to diffraction-limited MTF. ICL cases showed less spread out of PSF than F-LASIK cases. ICL cases showed better visual acuity values than F-LASIK cases for all pupils, contrasts, and myopic treatments (p<0.05). No statistically significant differences were found in contrast sensitivities between ICL and F-LASIK cases with -3-D myopia for both pupils for all evaluated spatial frequencies (p>0.05). For -6-D myopia, however, statistically significant differences in contrast sensitivities were found for both pupils for all evaluated spatial frequencies (p<0.05). Contrast sensitivities were better after ICL implantation than after F-LASIK. Conclusions: ICL implantation and F-LASIK provide good optical and visual quality, although the former provides better outcomes of MTF, PSF, visual acuity, and contrast sensitivity, especially for cases with large refractive errors and pupil sizes. These outcomes are related to the F-LASIK producing larger high-order aberrations. .


Objetivo: Comparar a qualidade óptica e visual da lente implantável de collamer (ICL) e da ceratomileuse in situ com laser de femtosegundo (F-LASIK) na correção de miopia. Métodos: O simulador visual de óptica adaptativa CRX1 (Imagine Eyes, Orsay, França) foi usado para simular o padrão de aberração de frentes de onda, depois de dois procedimentos cirúrgicos: implante de ICL e tratamento F-LASIK para -3 e -6 D. A acuidade visual em diferentes contrastes e sensibilidade ao contraste em 10, 20 e 25 ciclos/grau (cpd) foram medidos para pupilas de 3 e 5 mm. A função de transferência de modulação (MTF) e a função de espalhamento de ponto (PSF) foram calculados para a pupila de 5 mm. Resultados: A MTF do F-LASIK foi pior do que a do ICL, que estava perto da MTF do limite de difração. A ICL apresentou menor espalhamento do PSF do que o F-LASIK. ICL apresentou melhores valores da acuidade visual do que F-LASIK para todas as pupilas, contrastes e tratamentos miópicos (p<0,05). Não foram encontradas diferenças estatisticamente significantes na sensibilidade ao contraste entre ICL e F-LASIK de -3 D, para ambas as pupilas e quaisquer frequências espaciais avaliadas (p>0,05). Por outro lado, para -6 D, diferenças estatisticamente significativas na sensibilidade ao contraste foram encontrados para ambas as pupilas e todas as frequências espaciais avaliadas (p<0,05). Sensibilidade ao contraste foi melhor após o implante da ICL que após o F-LASIK. Conclusões: ICL e F-LASIK proporcionam uma boa qualidade óptica e visual, embora a ICL oferece melhores resultados de MTF, PSF, acuidade visual e sensibilidade ao contraste, especialmente para grandes erros de refração e tamanhos de pupila. Estes resultados estão relacionados ao procedimento F-LASIK que induz maiores aberrações ...


Asunto(s)
Adulto , Humanos , Adulto Joven , Queratomileusis por Láser In Situ , Implantación de Lentes Intraoculares , Miopía/cirugía , Lentes Intraoculares Fáquicas , Aberrometría , Acomodación Ocular/fisiología , Simulación por Computador , Sensibilidad de Contraste/fisiología , Miopía/fisiopatología , Resultado del Tratamiento , Agudeza Visual/fisiología
7.
Arq. bras. oftalmol ; Arq. bras. oftalmol;76(6): 335-338, nov.-dez. 2013. graf, tab
Artículo en Portugués | LILACS | ID: lil-701281

RESUMEN

OBJETIVO: Avaliar comparativamente os resultados cirúrgicos, na técnica LASIK, realizando com laser de femtosegundo e microcerátomo mecânico. MÉTODOS: Estudo clínico, prospectivo, comparativo, randomizado e mascarado de 32 olhos (16 pacientes). Cada paciente foi submetido a diferentes técnicas para o LASIK, em um dos olhos foi utilizado o microcerátomo HansatomeTM Bausch & Lomb (grupo microcerátomo) e no outro foi utilizado femtosegundo FEMTO LDV TM Ziemer (grupo femtosegundo). A triagem ocorreu no setor de Cirurgia Refrativa do Hospital de Olhos do Paraná entre 07/2010 e 09/2010. Os critérios de inclusão foram miopia menor que 6,00 D, astigmatismo menor que 3,00 D, menor que 5,00 D de hipermetropia, refração estável, diâmetro corneano menor que 11 mm, descontinuação de lente de contato sete dias antes da avaliação pré-operatória, acuidade visual de no mínimo 20/20 em ambos os olhos. As variáveis analisadas no pré-operatório entre os grupos, femtosegundo e microcerátomo foram: acuidade visual sem correção e com correção, equivalente esférico, aberrações totais de alta ordem, acuidade visual de baixo contraste, preferência do paciente e complicações. RESULTADOS: Todas as variáveis estudadas foram similares nos dois grupos. CONCLUSÃO: Não foi possível observar neste estudo, diferenças significativas entre os grupos analisados.


PURPOSE: To assess LASIK flaps made by femtosecond laser and mechanical microkeratome. METHODS: Clinical, prospective, randomized, masked study of 32 eyes (16 patients). Both eyes of all patients were operated, each patient underwent different techniques for lasik. Microkeratome HansatomeTMBausch & Lomb (group microkeratome) was used in one eye and femtosecond laser Femto LDVTMZiemer (group femtosecond) was used for the fellow eye. Patients were selected from the Refractive Surgery service of the Eye Hospital of Paraná between July 2010 and September 2010. Inclusion criteria were myopia less than 6.00 D, astigmatism less than 3.00 D, hyperopia less than 5.00 D, stable refraction over one year, corneal diameter smaller than 11 mm, discontinuation of contact lenses seven days before the preoperative evaluation, corrected visual acuity of at least 20/20. Eyes were randomly allocated for each technique. The studied variables were: visual acuity with and without correction, residual refractive error, high order aberrations, low contrast visual acuity, complications and subjective patient preference. RESULTS: All studied variables were similar between the two groups. CONCLUSION: We could not demonstrate any difference between the studied groups.


Asunto(s)
Humanos , Queratomileusis por Láser In Situ/métodos , Láseres de Excímeros/uso terapéutico , Miopía/cirugía , Colgajos Quirúrgicos/cirugía , Sensibilidad de Contraste , Córnea/cirugía , Sustancia Propia/cirugía , Queratomileusis por Láser In Situ/instrumentación , Periodo Posoperatorio , Estudios Prospectivos , Estadísticas no Paramétricas , Factores de Tiempo , Resultado del Tratamiento , Agudeza Visual
8.
Arq. bras. oftalmol ; Arq. bras. oftalmol;75(2): 126-130, mar.-abr. 2012. ilus, graf, tab
Artículo en Portugués | LILACS | ID: lil-640160

RESUMEN

PURPOSE: To assess the outcomes of intrastromal corneal ring (ISCR) implantation for the treatment of corneal ectasia. METHODS: Thirty-five consecutive patients with secondary corneal ectasia treated with keraring intrastromal corneal ring segment implantation aided by intralaser femtosecond technique (K-ICRS-FS) were evaluated. Visual acuity (logMAR), refraction and astigmatism vector analysis were measured preoperatively and 3 months postoperatively using vector analysis as described by some authors. RESULTS: Visual acuity improved from 0.40 ± 0.20 to 0.25 ± 0.13 logMAR (p=0.0002), with reduction of the spherical equivalent from -5.41 ± 4.78 D to -2.83 ± 3.29 D (P=0.0002). Mean astigmatism reduction was 3.92 ± 2.52 D. K maximum decreased from 51.65 ± 5.83 D preoperatively to 48.58 ± 5.54 D (p=0.001) 3 months after the surgery and K minimum decreased from 45.92 ± 4.64 D to 43.96 ± 5.06 D (p=0.0041). There were no intraoperative or postoperative complications. CONCLUSION: Intrastromal corneal ring implantation with the use of a femtosecond laser was a safe procedure, with low risk of complications and significant improvement on visual acuity and topographic data in this seeting of patients with secondary corneal ectasia.


OBJETIVO: Avaliar os resultados do implante de anel intraestromal (Keraring®) com laser de femtosegundo para o tratamento de ectasias corneanas (ceratocone e dege­neração marginal pelúcida). MÉTODO: Estudo retrospectivo em 35 pacientes consecutivos com ectasia corneana submetidos a implante de anel intracorneano (Keraring®). Acuidade visual (logMAR), refração, ceratometria e a análise vetorial do astigmatismo foram as variáveis analisadas. O túnel para o implante dos segmentos foi confeccionado com laser de femtosegundo. Os pacientes foram seguidos pelo período mínimo de três meses. RESULTADOS: A acuidade visual corrigida melhorou de 0,40 ± 0,20 para 0,25 ± 0,13 (p=0,0002), com diminuição do equivalente esférico de -5,41 ± 4,78 D no pré-op. para -2,83 ± 3,29 D no pós-op. (p=0,0002) e média de 3,92 ± 2,52 D na análise vetorial do astigmatismo. O K máximo variou de 51,65 ± 5,83 D para 48,58 ± 5,54 D (p=0,000) e o K mínimo de 45,92 ± 4,64 D para 43,96 ± 5,06 D (p=0,0041). Não houveram complicações intra ou pós-operatórias). CONCLUSÃO: Os resultados deste estudo mostraram que o implante do anel intra es­tromal é um procedimento seguro, com baixo risco de complicações, tendo determinado importante melhora na acuidade visual e dos dados topográficos de pacientes com ectasias corneanas.


Asunto(s)
Adulto , Femenino , Humanos , Queratocono/cirugía , Implantación de Prótesis/métodos , Topografía de la Córnea , Estudios de Seguimiento , Refracción Ocular , Estudios Retrospectivos , Índice de Severidad de la Enfermedad , Resultado del Tratamiento , Agudeza Visual
9.
Surg. cosmet. dermatol. (Impr.) ; 3(3): 213-218, set. 2011. ilus, tab, graf
Artículo en Inglés, Portugués | LILACS-Express | LILACS | ID: lil-606391

RESUMEN

Introdução: O vitiligo é cosmeticamente desfigurante e pode causar significativa morbidade psicológica. A maioria das terapêuticas requer tratamento longo e pode levar a resultados decepcionantes. Recentemente, o Eximer laser-308nm revelou ser efetivo no tratamento de vitiligo. Objetivo: Neste estudo retrospectivo foram analisadas a eficácia e satisfação dos pacientes que usaram Eximer laser-308nm no tratamento de manchas de vitiligo em diferentes regiões anatômicas. Métodos: Participaram 123 pacientes com vitiligo generalizado ou localizado, apresentando 321 lesões. Os pacientes foram tratados em clínica privada de 2007 a 2010. A análise da resposta ao tratamento foi feita por comparação de registros clínicos e fotográficos obtidos antes e após o tratamento, por dois examinadores independentes. Resultados: Setenta e sete dos 123 pacientes apresentaram repigmentação superior a 60%; 26 entre 40 e 59%; e 20% tiveram repigmentação inferior a 39%. Lesões na face responderam melhor ao tratamento do que as localizadas em outras regiões corporais. As áreas menos sensíveis foram cotovelos, mãos e pés. De forma geral, os pacientes ficaram satisfeitos com o tratamento. Conclusões: O uso do Excimer laser para tratamento do vitiligo foi eficaz, seguro e levou a resultados cosmeticamente satisfatórios com melhora da autoestima dos pacientes

10.
Arq. bras. oftalmol ; Arq. bras. oftalmol;74(2): 102-105, Mar.-Apr. 2011. graf, tab
Artículo en Portugués | LILACS | ID: lil-593130

RESUMEN

OBJETIVO: Comparar a pressão intraocular (PIO) pré e pós-LASIK, correlacionando-as com as mudanças da espessura corneana central (ECC) e ceratometria simulada média (K), assim como verificar o resultado de fórmula corretiva proposta anteriormente. MÉTODOS: Estudo longitudinal, prospectivo, realizado em pacientes submetidos a LASIK. Os pacientes foram submetidos ao exame oftalmológico completo, no pré operatório e após 2 meses da cirurgia. A pressão intraocular foi avaliada com tonômetro de aplanação de Goldmann entre 9 h e 11 h da manhã, a ceratometria simulada média foi avaliada por meio de topografia corneana e a espessura corneana central foi aferida por paquímetro ultrassônico, sendo considerada a média de três aferições. Foram excluídos dois pacientes com cirurgias ou doenças oculares prévias, e uso prévio de corticosteróide tópico nos últimos três meses. As cirurgias foram realizadas de acordo com os procedimentos-padrão. Foi utilizada a fórmula [PIO real = PIO aferida + (540 - ECC)/71 + (43 - K)/2,7 + 0,75 mmHg] proposta para correção da pressão intraocular pós-operatória. RESULTADOS: Quinze olhos de oito pacientes foram avaliados, a idade variou de 24 a 46 anos (média: 31,37 ± 7,27). Foi observada diferença estatisticamente significante entre as medidas da pressão intraocular, de ceratometria simulada média e da espessura corneana central pré e pós-LASIK. (p=0,0001). Foi observado que para cada 1D corrigida, há uma subestimação, em média, de 1,06 ± 0,59 mmHg (0,11 a 1,89 mmHg). A aplicação da fórmula corretiva levou a 80 por cento dos olhos com a tonometria estimada entre ± 2,50 mmHg da pré-operatória, no entanto, quando comparada com a tonometria pré-operatória, estas são estatisticamente diferentes (p=0,0266). CONCLUSÕES: Os olhos submetidos a LASIK apresentaram PIO pós-operatória menor do que a pré-operatória. A pressão intraocular pôde ser moderadamente correlacionada com a espessura corneana central e fracamente com a ceratometria simulada média. Não houve correlação entre a profundidade de ablação e a variação da pressão intraocular, no pós-operatório. Usando a fórmula proposta, pudemos averiguar que 80 por cento dos pacientes apresentaram pressão intraocular entre ± 2,50 mmHg da pré-operatória.


PURPOSE: To compare the intraocular pressure (IOP) pre and post LASIK, correlating it to changes in central corneal thickness (CCT) and average simulated keratometry (K), as well as verifying the results of a corrective formula previously proposed. METHODS: Longitudinal prospective study conducted in outpatients that underwent to LASIK. Patients underwent complete ophthalmic examination, previously and 2 months after the surgery. Intraocular pressure was evaluated with Goldmann applanation tonometer between 9 am and 11 am, average simulated keratometry was evaluated using corneal topography and central corneal thickness was measured with ultrasound pachymetry, been considered the average of three measurements. Two patients were excluded due to surgery or eye disease, and previous use of topical steroids over the past three months. The surgeries were performed according to standard procedures. The formula [real IOP = IOP measured + (540 - ECC)/71 + (43 - K)/2.7 + 0.75 mmHg] proposed for correcting intraocular pressure was used. RESULTS: Fifteen eyes of eight patients were evaluated, age ranged from 24 to 46 years (mean: 31.37 ± 7.27). There was a statistically significant difference between the measurements of intraocular pressure, central corneal thickness and average simulated keratometry pre and post-LASIK. (p=0.0001). It was observed that each 1D corrected underestimated the IOP 1.06 ± 0.59 mmHg (0.11 a 1.89 mmHg). The use of the corrective formula lead to 80 percent of eyes within 2.50 mmHg of preoperative intraocular pressure. Although, the two sets of data are statistically different (p=0.0266). CONCLUSIONS: Post LASIK eyes presented lower intraocular pressure than preoperatively. Intraocular pressure was moderately correlated to central corneal thickness and weakly correlated to average simulated keratometry. With the use of the corrective formula, we were able to determine that 80 percent were within 2.50 mmHg of the preoperative intraocular pressure.


Asunto(s)
Adulto , Femenino , Humanos , Masculino , Persona de Mediana Edad , Adulto Joven , Presión Intraocular/fisiología , Queratomileusis por Láser In Situ , Algoritmos , Astigmatismo/cirugía , Topografía de la Córnea , Córnea/patología , Miopía/cirugía , Tamaño de los Órganos , Periodo Posoperatorio , Estudios Prospectivos , Tonometría Ocular , Resultado del Tratamiento
11.
Surg. cosmet. dermatol. (Impr.) ; 2(2): 124-129, Abr.-Jun. 2010. ilus., tab.
Artículo en Inglés, Portugués | LILACS | ID: biblio-884157

RESUMEN

Introdução: O vitiligo é doença idiopática adquirida, caracterizada por manchas hipocrômicas e acrômicas bem delimitadas, sendo o Excimer Laser 308nm um dos possíveis tratamentos para essa dermatose. Objetivo: Analisar estudos publicados em revistas indexadas sobre a utilização do Excimer Laser 308nm, no tratamento de vitiligo. Método: Pela abordagem qualitativa, fez-se levantamento bibliográfico de artigos científicos relacionados ao tema no período de 2001 a 2009, nas bases de dados Medline, Lilacs e Scielo. Resultados: Segundo essa revisão bibliográfica o Excimer Laser 308nm apresentou resultados positivos no tratamento de vitiligo.As lesões recentes e as localizadas na face respondem melhor do que as de outros locais. As extremidades são de resposta mais difícil. A idade do paciente não interfere no resultado. Em média, foram necessárias 11 sessões até o início da repigmentação.O ideal é que a aplicação seja feita uma a três vezes por semana, com intervalo nunca inferior a 48 horas. Conclusão: O Excimer Laser no tratamento de vitiligo é efetivo e seguro quando comparado a outras modalidades de tratamento. O resultado depende da localização e do tempo da doença.


Introduction: Vitiligo is an acquired idiopathic disorder characterized by hypochromic and achromic well-delimited macules.The 308 nm excimer laser can be used to treat this condition. Objective:To analyze studies published in indexed medical journals on the use of the 308 nm excimer laser in the treatment of vitiligo. Method: Adopting a qualitative approach, a survey of related articles from 2001 to 2009 was carried out using the Medline, Lilacs and Scielo databases. Results: According to the literature review, the 308 nm excimer laser achieved positive results in the treatment of vitiligo. Recent lesions and those located on the face responded better than those located elsewhere.The extremities of the body were more difficult to treat using this method.The patient's age did not affect the outcome. On average, 11 sessions were necessary before the re-pigmentation started. Ideally, the laser application should be carried out from one to three times a week, with at least 48-hour intervals. Conclusion: The 308 nm excimer laser is effective and safe in the treatment of vitiligo when compared to other treatment modalities.The results depend on the location and the timeline of the disorder.

12.
Rev. bras. oftalmol ; 68(5): 271-277, set.-out. 2009. ilus, graf, tab
Artículo en Portugués | LILACS | ID: lil-536428

RESUMEN

OBJETIVO: Avaliar as alterações que ocorrem na sensibilidade corneanas após as cirurgias de LASIK e PRK MÉTODOS: Estudo prospectivo onde foram avaliados 60 olhos de 30 pacientes submetidos a LASIK bilateral simultaneamente e mais 30 olhos de 15 pacientes submetidos a PRK bilateral simultaneamente. De acordo com a quantidade de ablação intra-operatórias, os olhos foram divididos em dois grupos: Grupo 1 (menor que 40 µm) e Grupo 2 (Maior que 40 µm). A sensibilidade corneana foi medida na região central da córnea pelo estesiometro Cochet Bonnet® no pré operatório e após 30, 90 e 180 dias da cirurgias. RESULTADOS: A sensibilidade corneana na LASIK apresentou-se diminuída durante os três primeiros meses retornando as valores pré operatórios aos 6 meses; E de acordo com a quantidade de ablação o Grupo 1 apresentou diferença estatisticamente significante em relação ao Grupo 2 durante os três primeiros meses; No entanto a PRK recuperou seus valores pré operatório aos três meses e de acordo com a quantidade de ablação o Grupo 1 apresentou diferença estatisticamente significante somente no primeiro mês de pós operatório. CONCLUSÃO: A LASIK apresentou sensibilidade menor em relação ao PRK durante os 3 primeiros meses e somente aos 6 meses os valores da sensibilidade corneana foram similares; Os resultados também sugerem que a quantidade de ablação está relacionada com a diminuição da sensibilidade corneana durante os primeiros meses em ambas as técnicas cirúrgicas, principalmente na LASIK.


PURPOSE: To evaluate the alterations that occur on the cornea sensitivity after Lasik and PRK surgery. METHODS: Prospective studies have evaluated60 eyes from 30 patients subjected simultaneously to bilateral Lasik and 30 eyes from 15 patients subjected simultaneously to bilateral PRK. According to the amount of inner operatory ablation the eyes were divided into two groups: Group I (< 40 µm) and group II (> 40µm). The cornea sensitivity was measured in the central region of the cornea on the pre operatory and then again at 30, 90 and 180 days after the surgery with the esthesiometer. RESULTS: The cornea sensitivity in Lasik presented itself in a minor way during the first three months, returning to pre operatory values at six months; and according to the amount of ablation group I presented statistically significant difference in comparison to group II during the first three months; however PRK recovered its pre operatory values at three months and according to the amount of ablation group I presented statistically significant difference only on the first month of pre operatory. CONCLUSION: Lasik showed the least sensitivity in comparison to PRK during the first three months, only at six months the sensitivity values were similar to each other; the results suggest that the result of ablation endangers the cornea sensitivity during the first months on both surgical techniques especially Lasik.


Asunto(s)
Córnea/fisiopatología , Enfermedades de la Córnea/etiología , Queratomileusis por Láser In Situ , Nervio Oftálmico , Queratectomía Fotorrefractiva , Sensación