Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 151
Filtrar
1.
Micron ; 187: 103724, 2024 Sep 25.
Artículo en Inglés | MEDLINE | ID: mdl-39353266

RESUMEN

Carbonate formations constitute the primary source of hydrocarbon reservoirs worldwide, highlighting the importance of gaining a deeper understanding of matrix acidizing phenomena to enhance well productivity in these formations. Microstructural analysis of acidified cores is a key method to assess acidizing systems in carbonate rock samples. X-ray computed microtomography (Micro-CT) has significantly contributed to this field, primarily focusing on the qualitative and quantitative characterization of the profiles of carbonate mineral dissolution, also known as wormholes, created during matrix acidizing. This non-destructive evaluation technique allows the internal analysis of a sample without altering its internal structure or chemical composition. This work focuses on a comprehensive review of the research studies and the main applications of micro-CT for evaluating and characterizing matrix acidizing in carbonates. First, an overview of the fundamentals of micro-CT and acid stimulation in carbonates is provided. Next, the applications of micro-CT are discussed and grouped into microstructural characteristics of wormholes, dynamic in-situ experiments, and pore-scale modeling topics. A case study is presented with a methodology based on micro-CT analysis for matrix acidizing. Finally, future work and current challenges, such as 4D CT and CT-based acidizing models, are discussed.

2.
Int. j. morphol ; 42(4): 929-935, ago. 2024. ilus
Artículo en Español | LILACS | ID: biblio-1569255

RESUMEN

Los salmónidos, durante su desarrollo, pueden experimentar ocasionalmente deformaciones esqueléticas. Para su diagnóstico se emplean diversas metodologías, entre las que se incluyen radiografías, técnicas histológicas, diafanización con tinciones de alizarina y azul de alcián, así como el uso del microscopio electrónico de barrido (SEM), cada una con sus inherentes ventajas y desventajas. Este estudio tuvo como finalidad evaluar y comparar la eficacia de la tomografía microcomputarizada (Micro-CT) para el análisis anatómico, reconstruyendo tridimensionalmente las imágenes y contrastándolas con los resultados obtenidos mediante la técnica de diafanización. Se analizaron las aletas caudales de cinco ejemplares de salmón Oncorhynchus kisutch: dos sujetos a diafanización y tres procesados para análisis mediante Micro-CT utilizando el equipo BRUKER SkyScan 1272. La técnica de Micro-CT demostró superioridad en la resolución de las estructuras óseas, facilitando una exploración detallada de las variaciones morfológicas y la distribución de la densidad mineral. Este enfoque permitió identificar anomalías en la morfología y crecimiento de las últimas vértebras y lepidotriquias dorsales, así como una densidad incrementada en lepidotriquias dorsales malformadas. La mayor resolución proporcionada por la Micro-CT no solo potencia nuestra comprensión de la ontogenia piscícola y su adaptación a ambientes diversos, sino que además inaugura perspectivas innovadoras para el estudio de la evolución de las estrategias locomotoras y las respuestas adaptativas frente a cambios ambientales a través del tiempo.


SUMMARY: During their development, some species of salmonids may occasionally experience skeletal deformations. Several methodologies are currently being used for the diagnosis of such malformations, among which X-rays, histological techniques, diaphanization coupled either with Alizarin Red or Alcian Blue stains, as well as Scanning Electron Microscopy (SEM) can be mentioned. Each one of those methods presents inherent advantages and disadvantages. The purpose of this study was twofold: Firstly, to evaluate and compare the effectiveness of microcomputed tomography (Micro-CT) technology for anatomical analysis, three-dimensionally reconstructing the obtained images; and secondly, to contrast those images with the results obtained through the diaphanization technique. The caudal fins of five specimens of the Oncorhynchus kisutch salmon were analyzed: Two specimens were subjected to diaphanization and three were processed for Micro-CT analysis, using the BRUKER SkyScan 1272 equipment. The Micro-CT technology demonstrated superiority in the resolution of bone structures, facilitating a detailed exploration of morphological variations, as well as the distribution of mineral density. This experimental approach allowed us to identify anomalies in the morphology and growth of the last vertebrae and dorsal lepidotrichiae, as well as an increased mineral density in the malformed dorsal lepidotrichiae. The higher resolution provided by Micro-CT not only enhances our understanding of the fish ontogeny and its adaptation to diverse environments, but also opens innovative perspectives for the study of the evolution of locomotor strategies and adaptive responses to environmental changes.


Asunto(s)
Animales , Oncorhynchus kisutch/anatomía & histología , Microtomografía por Rayos X/métodos , Salmonidae/anatomía & histología , Huesos/diagnóstico por imagen , Densidad Ósea , Imagenología Tridimensional , Aletas de Animales/diagnóstico por imagen
3.
Eur J Oral Sci ; 132(5): e13014, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-39160699

RESUMEN

This study aimed to evaluate the effects of the estrogen depression during orthodontic tooth movement on alveolar bone microarchitecture and periodontal ligament. Female Wistar rats were divided into two groups, one consisting of non-ovariectomized animals subjected to orthodontic tooth movement, and one comprising ovariectomized animals subjected to orthodontic tooth movement. Micro-CT assessment of bone volume to total volume (BV/TV), total porosity, trabecular thickness (Tb.Th), trabecular number (Tb.N), and trabecular separation (Tb.Sp) in the alveolar bone of the orthodontically moved tooth was performed. Histomorphometric analyses were made in the periodontal ligament, and immunoexpression of RANK, RANKL, OPG, and TUNEL were quantified. Orthodontic tooth movement in the group of ovariectomized rats was faster than in non-ovariectomized animals. The alveolar bone area showed lower values of BV/TV and trabecular thickness, and higher bone porosity and trabeculae numbers in the ovariectomized rats. Histological analyses in the ovariectomized group revealed an increase in collagen fibers in the periodontal ligament. The apoptotic cell counts in the periodontal ligament were higher in the group of ovariectomized rats than in the sham-operated rats. Ovariectomy resulted in an increase in tooth movement and alteration of the alveolar bone microstructure in the first 7 day of orthodontic tooth movement, and in the presence of apoptotic cells in the periodontal ligament.


Asunto(s)
Proceso Alveolar , Estrógenos , Ovariectomía , Ligamento Periodontal , Ratas Wistar , Técnicas de Movimiento Dental , Microtomografía por Rayos X , Animales , Ligamento Periodontal/patología , Técnicas de Movimiento Dental/efectos adversos , Femenino , Proceso Alveolar/patología , Proceso Alveolar/diagnóstico por imagen , Ratas , Apoptosis , Ligando RANK/metabolismo , Osteoprotegerina/metabolismo , Receptor Activador del Factor Nuclear kappa-B/metabolismo , Densidad Ósea , Etiquetado Corte-Fin in Situ
4.
Iran Endod J ; 19(3): 199-207, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39086709

RESUMEN

Introduction: This study aimed to compare the effectiveness of two endodontic cleaning techniques, passive ultrasonic irrigation (PUI) and the XP-endo Finisher R (XPR) system, in removing residual filling material during endodontic retreatment procedures. Materials and Methods: Forty mandibular premolars with oval canals were divided into four groups based on the sealer used (AH-Plus or Bio-C Sealer) and the cleaning technique employed (PUI or XPR). To ensure uniformity of canal volume among groups, initial micro-CT scans were conducted. The canals were instrumented, filled, and then re-instrumented before undergoing either PUI or XPR cleaning techniques. Residual filling material volumes were assessed through micro-CT scans, and statistical analysis was performed using the Kruskal-Wallis and Mann-Whitney U tests. Results: Following instrumentation, there was no significant difference in residual filling material volumes between AH-Plus and Bio-C Sealer groups (1.35 mm3and 1.02 mm3, respectively; P>0.05). However, after supplementary cleaning techniques, XPR-cleaned specimens exhibited significantly less residual material compared to PUI-cleaned specimens (0.01 mm3 and 0.29 mm3 for Bio-C Sealer, and 0.07 mm3 and. 0.30 mm3 for AH-Plus, P<0.05). Conclusion: The XPR system was found to be more effective than PUI in removing residual filling material from Bio-C Sealer-filled root canals. This highlights its potential as a useful supplementary cleaning technique in endodontic retreatment procedures.

5.
Int Endod J ; 57(11): 1689-1698, 2024 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-38984709

RESUMEN

AIM: To compare the effects of Cervical Access Cavity (CervAC) and Traditional Access Cavity (TradAC) on root canal preparation, root canal filling, and fracture resistance in mandibular incisors. METHODOLOGY: Twenty recently extracted and intact mandibular incisors were initially scanned using a micro-CT device. The specimens were anatomically matched to create two groups (n = 10). A wedge-shaped non-carious cervical lesion (NCCL) was created on the buccal aspect of all teeth using a double-faced segmented diamond disc. In group 1, a TradAC was prepared, whilst in group 2, access was created through the simulated NCCL using a round diamond bur 1012. After root canal preparation with Rotate instruments sizes 15/0.04, 20/0.04, and 25/0.04, the teeth were scanned again and evaluated for root canal volume and surface area, static voxels, volume of removed dental tissue, and dentine thickness. After that, the root canals were filled using the single-cone technique, teeth were restored with composite resin, and subsequently rescanned to calculate the volume of filling materials and voids. Then, the restored teeth were subjected to fracture resistance tests using a universal testing machine. Statistical comparisons between groups were performed with the Mann-Whitney test or the Student's t-test, with a statistical significance level of 5%. RESULTS: Statistical comparisons indicated no significant differences between groups in terms of root canal volume, surface area, static voxels, removed root dentine, root canal filling volume, percentage of voids, or fracture resistance load (p > .05). Conversely, teeth prepared with TradAC showed a significantly higher percentage of dental tissue removed from the crown (p = .001) and a greater volume of filling material remnants in the pulp chamber (p < .001) compared to the CervAC group. A significantly lower percentage reduction in dentine thickness was observed only on the mesial aspect of root at Level 1 in TradAC group (p = .008). CONCLUSIONS: CervAC can be considered a viable alternative approach in the presence of NCCL in mandibular incisors.


Asunto(s)
Incisivo , Mandíbula , Obturación del Conducto Radicular , Preparación del Conducto Radicular , Fracturas de los Dientes , Humanos , Obturación del Conducto Radicular/métodos , Preparación del Conducto Radicular/instrumentación , Preparación del Conducto Radicular/métodos , Microtomografía por Rayos X , Cuello del Diente/patología , Cavidad Pulpar , Técnicas In Vitro
6.
Acta Odontol Latinoam ; 37(1): 34-39, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38920124

RESUMEN

The remaining filling material after retreatment can harbor bacteria and organic tissues that can influence the outcome of the therapy. AIM: The aim of this study was to evalúate, by micro-CT, the amount of filling material remaining in the root canal after its removal using WaveOne Gold or ProDesign RT. MATERIAL AND METHOD: Forty human mandibular canines were instrumented with the ProTaper Next system up to the X2 instrument (25.06) and filled with gutta-percha cones and AHPlus. Teeth were divided into 2 groups (n=20): WaveOne Gold 25.07 (WOG) and ProDesign RT 25.08 (PRT) for filling removal, after which they were scanned in a micro-CT device to quantify the volume of remaining filling material. The data were subjected to log 10 transformation, Student 's t-test was performed to account for multiple observationsper sample, significance was set at 5%. RESULTS: Student 's t-test showed that there was no difference between the two systems regarding the volume of remaining filling material in the thirds: apical (p = 0.392), middle (p = 0.065), or cervical (p = 0.918). CONCLUSIÓN: Remaining filling material was present in all groups and both systems were similar in removing root filling material in mandibular canines.


A permanencia de material obturador após o retratamento pode abrigar bactérias e tecidos orgánicos que podem influenciar o resultado da terapia. OBJETIVO: O objetivo deste estudo foi avaliar, por micro-CT, a quantidade de material obturador remanescente no canal radicular após a desobturagdo com WaveOne Gold e ProDesign RT. MATERIAL E MÉTODO: Quarenta caninos inferiores humanos foram instrumentados com o sistema ProTaper Next até o instrumento X2 (25.06) e obturados com cones de guta-percha e AHPlus. Os dentes foram divididos em dois grupos (n=20): WaveOne Gold 25.07 (WOG) e ProDesign RT 25.08 (PRT) e escaneados em micro-CT para quantificagdo do volume de material obturador remanescente. Os dados foram submetidos á transformando log 10, o teste t de Student foi realizado para contabilizar múltiplas observagoes por amostra, a significáncia foi fixada em 5%. RESULTADOS: O teste t de Student mostrou que ndo houve diferenga no volume de material obturador remanescente entre os dois sistemas nos tergos: apical (p = 0,392), médio (p = 0,065) ou cervical (p = 0,918). CONCLUSÃO: O material obturador remanescente estavapresente em todos os grupos e ambos os sistemas foram semelhantes na remogdo do material obturador radicular nos caninos inferiores.


Asunto(s)
Materiales de Obturación del Conducto Radicular , Microtomografía por Rayos X , Humanos , Diente Canino/diagnóstico por imagen , Técnicas In Vitro , Diseño de Equipo
7.
Acta Odontol Latinoam ; 37(1): 3-12, 2024 04.
Artículo en Inglés | MEDLINE | ID: mdl-38920121

RESUMEN

Identifying the presence, size, type and location of voids in an endodontic obturation is of great clinical importance because it enables evaluation of the three-dimensionality of the sealing techniques, which can be related to the success of the endodontic treatment. AIM: To analyze by micro-CT the presence of voids in lower single-rooted premolar root canal obturations prepared using the single cone and ultrasound vibration technique. MATERIALS AND METHODS: Twenty extracted single-rooted lower premolars were selected, and the root canal prepared surgically and chemically. In GROUP 1 - Without Vibration, the canal was obturated with a single cone and bioceramic, without applying vibration. In GROUP 2 - With Vibration, the gutta-percha cone inside the root canal was held with a cotton plier to which ultrasound vibration was applied for 3 periods of 3 seconds each. A micro-CT scanner was used to acquire and reconstruct images for analysis. RESULTS: No significant difference was found between obturation techniques, though there were differences between thirds, with the cervical third having a higher percentage of voids than the middle and apical thirds. CONCLUSIONS: The results suggest that the volume of closed, open and total voids does not differ between treatments with and without ultrasound vibration. In the cervical third, the highest volume of voids was related to oval geometry in the teeth evaluated.


La presencia de vacíos en la obturación endodóntica, su tamaño y el tipo y localización tiene gran importancia clínica ya que permite evaluar la tridimensionalidad de las técnicas de sellado y relacionarlas con el éxito del tratamiento endodóntico. OBJETIVO: analizar mediante microtomografía la presencia de vacíos en la obturación del conducto radicular de premolares inferiores unirradiculares, utilizando la técnica de cono único y vibración con ultrasonido. MATERIALES Y MÉTODOS: se seleccionaron 20 premolares inferiores unirradiculares a los que se les realizó la preparación quirúrgica y química del conducto radicular. Se realizó la obturación con cono único y biocerámico GRUPO 1- sin vibración. En el GRUPO 2 - con vibración se aplicó vibración por ultrasonido, se tomó del cono de gutapercha colocado en el interior del conducto con pinza de algodón que fue vibrada durante 3 períodos de 3 segundos cada uno. Las mismas fueron adquiridas y reconstruidas en un microtomógrafo para posterior análisis de las imágenes obtenidas. RESULTADOS: No se evidenciaron diferencias significativas entre ambas técnicas de obturación comparadas, pero si entre los tercios analizados, siendo el cervical el que mayor porcentaje de vacíos presenta en comparación a los cortes correspondientes al tercio medio y apical. CONCLUSIONES: Los resultados sugieren que el volumen de vacíos cerrados, abiertos y total no varía en los tratamientos donde se aplica vibración por ultrasonido. En el tercio cervical, el mayor volumen de vacíos se relaciona con la geometría oval que presentaron las piezas dentarias evaluadas en este estudio.


Asunto(s)
Obturación del Conducto Radicular , Microtomografía por Rayos X , Obturación del Conducto Radicular/métodos , Humanos , Técnicas In Vitro , Diente Premolar/diagnóstico por imagen , Gutapercha
8.
Saudi Dent J ; 36(4): 568-573, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38690376

RESUMEN

Introduction: The anatomical configuration classified as Vertucci's type III is described as the second most prevalent in mandibular incisors. Methods: Thirty-six Vertucci's type III mandibular incisors were evaluated by micro-computed tomography (micro-CT) and divided into 3 groups (n = 12) according to the root canal preparation protocol (HyFlex CM [HCM], HyFlex EDM [HEDM], and Sequence Rotary File [SRF]). The teeth were scanned before and after performing 0.25 mm and 0.40 mm apical diameter preparations. The canal volume, dentin thickness, percentage of accumulated debris and untouched canal areas, transportation, and centering ability were measured. The data were statistically analyzed by ANOVA, Tukey, Kruskal-Wallis, and Dunn tests (P < 0.05). Results: The volume increase was more evident in the apical third. After 0.40 mm preparation, the SRF system provided a higher reduction (P < 0.05) in dentin thickness on the buccal surface 1 mm from the apex. There was higher canal transportation in the bucco-lingual direction. The 0.40 mm apical preparation reduced the percentage of untouched canal areas. The apical third had the highest percentage of untouched canal areas. The cervical third had the lowest volume of accumulated debris. Conclusions: Increasing the apical preparation to a diameter of 0.40 mm with the HCM, HEDM, and SRF systems in Vertucci's type III root canals of mandibular incisors proved to be safe and effective, reducing untouched canal areas. Clinical relevance: Root flattening can be intense to the point of generating a root canal bifurcation. Despite the decrease in the root canal diameter, a greater enlargement of the apical region is necessary and safe.

9.
Aust Endod J ; 50(2): 341-351, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38715465

RESUMEN

This study assessed canal preparation effects on disinfection and dentin preservation. Thirty mandibular incisors were paired into two experimental groups (n = 10). Following contamination, the initial microbial sample was collected. Instruments 30/0.03 (Group 1) and 30/0.05 (Group 2) were employed and a second sample was obtained. Canals were enlarged using instruments 40/0.03 and 40/0.05, respectively, and a third sample was collected. Final irrigation was performed, and sample S4 obtained. A final scan evaluated volume, surface area, unprepared areas, removed dentin and dentin thickness. Data were analysed using Student t-test, Mann-Whitney, Kruskal-Wallis and Dunn tests. A significant difference was observed between S1 and other time points (p < 0.05). Comparison between groups showed no differences in bacterial loads and in the percentage of microbial reduction (p > 0.05). Group 2 exhibited greater reduction in dentin thickness than group 1 in the mesial aspect of the root (p < 0.05). Instrument 30/0.03 might provide effective disinfection and safety during mandibular incisors canal preparation.


Asunto(s)
Desinfección , Incisivo , Mandíbula , Preparación del Conducto Radicular , Humanos , Preparación del Conducto Radicular/instrumentación , Preparación del Conducto Radicular/métodos , Desinfección/métodos , Cavidad Pulpar/microbiología , Diseño de Equipo , Dentina/microbiología , Carga Bacteriana
10.
Aust Endod J ; 50(2): 260-266, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38243635

RESUMEN

This study evaluated the impact of canal irrigation using surfactants associated to NaOCl on the percentage of voids of root canal filling through micro-computed tomographic (micro-CT) analysis. 27 mandibular mesial roots with Vertucci type II canal configuration with isthmus were selected and scanned in a micro-CT device. The specimens were assigned to three groups (n = 9), according to the irrigation solution during instrumentation: 2.5% NaOCl without additives (control), 2.5% NaOCl with 0.1% Benzalkonium Chloride and 2.5% NaOCl with 0.1% Tween 80. After obturation, the specimens were rescanned, and the percentage of voids were calculated. Data were analysed using one-way ANOVA with a significance level of 5%. The percentage of voids were similar among the groups (p > 0.05). None of the specimens showed completely voids-free areas. The addition of surfactants to NaOCl irrigation did not improve the quality of root canal filling of mandibular mesial root canals.


Asunto(s)
Irrigantes del Conducto Radicular , Hipoclorito de Sodio , Tensoactivos , Microtomografía por Rayos X , Hipoclorito de Sodio/farmacología , Tensoactivos/farmacología , Irrigantes del Conducto Radicular/farmacología , Humanos , Microtomografía por Rayos X/métodos , Compuestos de Benzalconio/farmacología , Obturación del Conducto Radicular/métodos , Cavidad Pulpar/efectos de los fármacos , Preparación del Conducto Radicular/métodos , Irrigación Terapéutica/métodos
11.
Acta odontol. latinoam ; Acta odontol. latinoam;37(1): 3-12, Jan. 2024. tab, graf
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1563654

RESUMEN

ABSTRACT Identifying the presence, size, type and location of voids in an endodontic obturation is of great clinical importance because it enables evaluation of the three-dimensionality of the sealing techniques, which can be related to the success of the endodontic treatment. Aim To analyze by micro-CT the presence of voids in lower single-rooted premolar root canal obturations prepared using the single cone and ultrasound vibration technique. Materials and methods Twenty extracted single-rooted lower premolars were selected, and the root canal prepared surgically and chemically. In GROUP 1 - Without Vibration, the canal was obturated with a single cone and bioceramic, without applying vibration. In GROUP 2 - With Vibration, the gutta-percha cone inside the root canal was held with a cotton plier to which ultrasound vibration was applied for 3 periods of 3 seconds each. A micro-CT scanner was used to acquire and reconstruct images for analysis. Results No significant difference was found between obturation techniques, though there were differences between thirds, with the cervical third having a higher percentage of voids than the middle and apical thirds. Conclusions The results suggest that the volume of closed, open and total voids does not differ between treatments with and without ultrasound vibration. In the cervical third, the highest volume of voids was related to oval geometry in the teeth evaluated.


RESUMEN La presencia de vacíos en la obturación endodóntica, su tamaño y el tipo y localización tiene gran importancia clínica ya que permite evaluar la tridimensionalidad de las técnicas de sellado y relacionarlas con el éxito del tratamiento endodóntico. Objetivo analizar mediante microtomografía la presencia de vacíos en la obturación del conducto radicular de premolares inferiores unirradiculares, utilizando la técnica de cono único y vibración con ultrasonido. Materiales y Método se seleccionaron 20 premolares inferiores unirradiculares a los que se les realizó la preparación quirúrgica y química del conducto radicular. Se realizó la obturación con cono único y biocerámico GRUPO 1- sin vibración. En el GRUPO 2 - con vibración se aplicó vibración por ultrasonido, se tomó del cono de gutapercha colocado en el interior del conducto con pinza de algodón que fue vibrada durante 3 períodos de 3 segundos cada uno. Las mismas fueron adquiridas y reconstruidas en un microtomógrafo para posterior análisis de las imágenes obtenidas. Resultados No se evidenciaron diferencias significativas entre ambas técnicas de obturación comparadas, pero si entre los tercios analizados, siendo el cervical el que mayor porcentaje de vacíos presenta en comparación a los cortes correspondientes al tercio medio y apical. Conclusiones Los resultados sugieren que el volumen de vacíos cerrados, abiertos y total no varía en los tratamientos donde se aplica vibración por ultrasonido. En el tercio cervical, el mayor volumen de vacíos se relaciona con la geometría oval que presentaron las piezas dentarias evaluadas en este estudio.

12.
Acta odontol. latinoam ; Acta odontol. latinoam;37(1): 34-39, Jan. 2024. tab, graf
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1563657

RESUMEN

ABSTRACT The remaining filling material after retreatment can harbor bacteria and organic tissues that can influence the outcome of the therapy. Aim The aim of this study was to evalúate, by micro-CT, the amount of filling material remaining in the root canal after its removal using WaveOne Gold or ProDesign RT. Material and Method Forty human mandibular canines were instrumented with the ProTaper Next system up to the X2 instrument (25.06) and filled with gutta-percha cones and AHPlus. Teeth were divided into 2 groups (n=20): WaveOne Gold 25.07 (WOG) and ProDesign RT 25.08 (PRT) for filling removal, after which they were scanned in a micro-CT device to quantify the volume of remaining filling material. The data were subjected to log 10 transformation, Student 's t-test was performed to account for multiple observationsper sample, significance was set at 5%. Results Student 's t-test showed that there was no difference between the two systems regarding the volume of remaining filling material in the thirds: apical (p = 0.392), middle (p = 0.065), or cervical (p = 0.918). Conclusión Remaining filling material was present in all groups and both systems were similar in removing root filling material in mandibular canines.


RESUMO A permanencia de material obturador após o retratamento pode abrigar bactérias e tecidos orgánicos que podem influenciar o resultado da terapia. Objetivo O objetivo deste estudo foi avaliar, por micro-CT, a quantidade de material obturador remanescente no canal radicular após a desobturagdo com WaveOne Gold e ProDesign RT. Material e Método Quarenta caninos inferiores humanos foram instrumentados com o sistema ProTaper Next até o instrumento X2 (25.06) e obturados com cones de guta-percha e AHPlus. Os dentes foram divididos em dois grupos (n=20): WaveOne Gold 25.07 (WOG) e ProDesign RT 25.08 (PRT) e escaneados em micro-CT para quantificagdo do volume de material obturador remanescente. Os dados foram submetidos á transformando log10, o teste t de Student foi realizado para contabilizar múltiplas observagoes por amostra, a significáncia foi fixada em 5%. Resultados O teste t de Student mostrou que ndo houve diferenga no volume de material obturador remanescente entre os dois sistemas nos tergos: apical (p = 0,392), médio (p = 0,065) ou cervical (p = 0,918). Conclusao O material obturador remanescente estavapresente em todos os grupos e ambos os sistemas foram semelhantes na remogdo do material obturador radicular nos caninos inferiores.

13.
Aust Endod J ; 50(1): 60-68, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37876340

RESUMEN

This study evaluated the impact of long-term storage conditions (medium and time) on the development of experimental dentinal microcracks through micro-computed tomography. Sixty freshly extracted premolars were stored in formalin, water, or dry conditions (n = 20) and scanned after 72 h, 30 days, 6 months and 3 years of extraction. The effect of the storage medium and time on the occurrence of dentinal defects was statistically evaluated. A total of 211 000 images were screened revealing the existence of 11 519 slices with dentinal defects. Dry conditions significantly contributed to the development of new defects in all time points. During the 3-year follow-up period, no new defects were detected in the teeth that were stored in water and, in a single tooth, in the formalin group, after 6 months of storage.


Asunto(s)
Fracturas de los Dientes , Humanos , Dentina/diagnóstico por imagen , Microtomografía por Rayos X , Preparación del Conducto Radicular , Agua , Formaldehído
14.
Neotrop Entomol ; 53(1): 101-109, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37878204

RESUMEN

The present study describes the immature stages of Opoptera syme (Hübner, [1821]) using SEM and Micro-CT to generate 2D and 3D models to study the morphology and chaetotaxy, and present information on the natural history, behavior, and population biology. In laboratory, eggs were laid singly, and the isolated larvae passed through six to seven instars. Host plant in the study site is unknown, but larvae are known to feed on bamboos; in laboratory, larvae accepted the ornamental bamboo Bambusa textilis McClure, 1940. Adults are diurnal and univoltine, flying from December to April (the austral summer). The present study adds information to the biology and natural history of Brassolini, an iconic and still poorly known tribe of Neotropical butterflies.


Asunto(s)
Mariposas Diurnas , Lepidópteros , Animales , Mariposas Diurnas/anatomía & histología , Brasil , Larva/anatomía & histología , Estaciones del Año , Biología
15.
J Endod ; 50(3): 376-380, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38147908

RESUMEN

INTRODUCTION: The purpose of this study was to evaluate the ability of the Reciproc, Reciproc Blue, and WaveOne Gold systems to remove filling material during endodontic retreatment of extracted human mandibular premolars. METHODS: Thirty-nine teeth were instrumented with the Protaper Universal System to the F3 file and filled with the Tagger hybrid technique using an F3 gutta-percha cone and AH Plus cement. At the end of this period, the teeth were scanned with micro-computed tomography before and after removal of the filling material from the root canals. The teeth were divided into 3 groups (n = 13) based on the apical volume, depending on the systems used to remove the filling material. Group GR: Reciproc 40/.06; Group GRB: Reciproc Blue 40/.06; and Group GWG: WaveOne Gold 35/.06. The results were statistically analyzed using the tests of Kruskal-Wallis, Duncan, and analysis of variance at a significance level of 5%. RESULTS: The results showed that there were no significant differences between the amounts of filling material removed, either for the apical and middle regions alone or in the overall evaluation for the 3 groups (P = .97). The time evaluation statistically showed that the GR and GWG groups required less time to clean the root canals than the GRB group. CONCLUSIONS: Reciproc R40 files and WaveOne Gold Medium files required less time for endodontic treatment than Reciproc Blue R40 files. There was no difference in the ability to remove obturation material between the 3 instruments. No instrument was able to completely remove the filling material from the root canals.


Asunto(s)
Materiales de Obturación del Conducto Radicular , Humanos , Microtomografía por Rayos X/métodos , Cavidad Pulpar/diagnóstico por imagen , Obturación del Conducto Radicular/métodos , Preparación del Conducto Radicular , Retratamiento , Gutapercha
16.
J. appl. oral sci ; J. appl. oral sci;32: e20230440, 2024. tab, graf
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1558240

RESUMEN

Abstract This study aimed to compare the quality of root canal obturation (ratio of area occupied by gutta-percha (G), sealer (S), and presence of voids (V)) in different anatomical irregularities (intercanal communications, lateral irregularities, and accessory canals) located at different thirds of the root canal system of mandibular molar replicas. Sixty-seven 3D printed replicas of an accessed mandibular molar were prepared using ProGlider and ProTaper Gold rotatory systems. Three specimens were randomly selected to be used as controls and did not receive further treatment. The rest were randomly distributed in 4 experimental groups to be obturated using either cold lateral compaction (LC), continuous wave of condensation (CW), and core-carrier obturation (ThermafilPlus (TH) or GuttaCore (GC)) (n=16 per group). AHPlus® sealer was used in all groups. The three controls and a specimen from each experimental group were scanned using micro-computed tomography. The rest of the replicas were sectioned at the sites of anatomical irregularities and examined at 30× magnification. The G, S, and V ratios were calculated dividing the area occupied with each element by the total root canal area and then compared among groups using the Kruskal-Wallis test. Voids were present in all obturation techniques with ratios from 0.01 to 0.15. CW obtained a significantly higher G ratio in the irregularity located in the coronal third (0.882) than LC (0.681), TH (0.773), and GC (0.801) (p<0.05). TH and GC achieved significantly higher G ratios in those located in the apical third (p<0.05). The worst quality of obturation was observed in the loop accessory canal with all obturation techniques. Whitin the limitations of this study, it can be concluded that CW and core-carrier obturation are respectively the most effective techniques for obturating anatomical irregularities located in the coronal and the apical third.

17.
Aust Dent J ; 68 Suppl 1: S5-S23, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-37984802

RESUMEN

A fundamental aspect of the Endodontic field is the knowledge of root canal anatomy. Using a variety of techniques, the internal and external anatomy of teeth have been extensively investigated throughout the past century. Recent improvements in three-dimensional computed tomography have enabled more detailed evaluations of root canal morphology in both clinical and laboratory settings. Essentially, researches have unveiled that the root canal constitutes a complex system, comprising not only the main root canal but also lateral components, including isthmuses, fins, accessory canals and apical ramifications. Undoubtedly, this intricate morphology poses a significant challenge when it comes to the process of shaping, cleaning and disinfecting the root canal system. This article aims to explore the anatomical aspects of the root canal system that impact the chemomechanical procedures.


Asunto(s)
Preparación del Conducto Radicular , Tratamiento del Conducto Radicular , Humanos , Preparación del Conducto Radicular/métodos , Tratamiento del Conducto Radicular/métodos , Cavidad Pulpar/diagnóstico por imagen , Raíz del Diente , Tomografía Computarizada por Rayos X , Microtomografía por Rayos X/métodos
18.
Int Endod J ; 56(10): 1301-1315, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37594701

RESUMEN

AIM: To assess the influence of a flat-side design on the geometry, metallurgy, mechanical performance and shaping ability of a novel nickel-titanium rotary instrument. METHODOLOGY: Sixty-five new 25-mm flat-side rotary instruments (size 25, taper 0.04) and their nonflat-side prototypes (n = 65) were assessed for major deformations and examined regarding macroscopic and microscopic design, determination of nickel and titanium elements ratio, measurement of phase transformation temperature and evaluation of mechanical performance parameters including time/cycles to fracture, maximum torque, angle of rotation, maximum bending and buckling strengths and cutting ability. Additionally, unprepared canal areas, volume of hard tissue debris and percentage reduction of dentine thickness were calculated for each tested instrument after preparing mesial canals of mandibular molars (n = 12), using micro-CT imaging. Statistical analyses were performed using the U-Mann-Whitney test and independent Student t-test (α = 5%). RESULTS: The number of spirals (n = 8) and blade direction (clockwise) were similar between both flat and nonflat instruments, whilst the helical angles were equivalent (⁓25°). Flat-instruments showed inconsistencies in the homogeneity of the gold colour on the flat-side surface, blade discontinuity, and incomplete and variable S-shaped cross-sections. The titanium-to-nickel ratios were equivalent, but significant differences in the R-phase finish and austenitic start phase transformation temperatures were observed between the flat and nonflat-side instruments. The flat-side instruments demonstrated superior cutting ability compared to the nonflat instruments, as well as, significantly lower values for time to fracture, rotation to fracture and maximum torque to fracture (p < .001). No statistical difference was observed between tested instruments regarding angle of rotation (p = .437), maximum bending (p = .152) and buckling load (p = .411). Preparation protocols using flat and nonflat instruments did not show any statistically significant differences (p > .05). All flat-side instruments exhibited deformation after shaping procedures. CONCLUSIONS: The flat-side instrument showcased enhanced cutting ability compared to its nonflat counterpart. However, it exhibited inferior performance in terms of time, rotation and maximum torque to fracture, along with distinct phase transformation temperatures. No differences were observed in the titanium-to-nickel ratios, angle of rotation, maximum bending, buckling load, preparation time, percentage of untouched canal walls, volume of hard tissue debris and percentage reduction of dentine thickness.


Asunto(s)
Níquel , Titanio , Humanos , Cavidad Pulpar , Metalurgia , Diente Molar
19.
Braz. dent. j ; Braz. dent. j;34(4): 85-92, July-Aug. 2023. tab, graf
Artículo en Inglés | LILACS-Express | LILACS, BBO - Odontología | ID: biblio-1520336

RESUMEN

Abstract Wetting the dentin is critical to atraumatic restorative treatment. The conventional insertion can be challenging when using high-viscosity glass-ionomer cement. This study evaluated the formation of gaps and voids after three insertion methods using micro-CT. Teeth underwent removal of occlusal and proximal caries through the atraumatic restorative treatment technique. Then, they were fixed in an artificial dental arch to simulate the clinical condition and were restored using three insertion methods: conventional, Centrix injection, and double-filling. Previous dentin conditioning procedures, steel matrix and wooden wedge application, and post-insertion procedures (digital compression and surface protection) were the same. The material was inserted using a manual instrument in the conventional technique and was inserted with a syringe in the Centrix injection group. In the double-filling technique, the tooth received a first layer of a flowable ionomer (through modifying the powder/liquid ratio), and a second layer (with standard ratio) was applied before the final set of the first one. A micro-CT unit scanned each tooth before and after restoration. Each cavity was defined as the volume of interest, and the volumes of gaps and voids were calculated. Data were analyzed using one-way ANOVA and Tukey posthoc test (p < .05). Double-filling had improved filling volume with lower values for gap volume, followed by Centrix injection. The conventional technique had the highest gap volume. No statistically significant difference was observed for void volume. Double-filling demonstrated fewer gaps, followed by Centrix injection, which is critical to obtain better adhesive, remineralizing, and antibacterial activities.


Resumo O molhamento da dentina parcialmente desmineralizada no fundo da cavidade dentária é fundamental para o sucesso do tratamento restaurador atraumático. No entanto, o método de inserção convencional pode ser desafiador ao usar cimento de ionômero de vidro de alta viscosidade. Este estudo avaliou a formação de gaps e vazios internos após três métodos de inserção de cimento de ionômero de vidro de alta viscosidade usando micro-CT. Dez terceiros molares foram submetidos à remoção de cárie oclusal através da técnica de tratamento restaurador atraumático e complementação proximal (com ou sem lesão pré-existente). Em seguida, foram fixados em uma arcada dentária artificial para simular a condição clínica. Os dentes foram restaurados usando a técnica de tratamento restaurador atraumático com três métodos de inserção: convencional, injeção Centrix e dupla inserção. Os procedimentos anteriores de condicionamento dentinário, inserção de matriz de aço, aplicação de cunha de madeira e procedimentos pós-inserção do material (como compressão digital e proteção de superfície) foram os mesmos para os três grupos testados. O material foi inserido com instrumento manual na técnica convencional, seguindo a metodologia clássica do tratamento restaurador atraumático. O material foi inserido com um dispositivo desenvolvido especificamente para esse fim na técnica de inserção com seringa tipo Centrix. Na técnica de dupla obturação, o dente recebeu uma primeira camada do cimento de ionômero de vidro mais fluido (obtido através da modificação da relação pó/líquido), e uma segunda camada (com relação pó/líquido padrão) foi aplicada antes da presa final da primeira. Um micro-CT escaneou cada dente antes e depois da restauração. Cada cavidade foi definida como o volume de interesse, e os volumes de gaps e vazios foram calculados. Os dados foram analisados por ANOVA one-way e teste post-hoc de Tukey com nível de significância de 5%. A dupla inserção melhorou significativamente o volume de preenchimento com valores percentuais mais baixos para o volume do gap, seguido pela injeção com seringa tipo Centrix. A técnica convencional apresentou o maior percentual de volume de gap. Nenhuma diferença estatisticamente significativa foi observada para o volume de vazios internos. O grupo de dupla inserção demonstrou menor formação de gaps, seguido pelo grupo de injeção com seringa tipo Centrix, que é fundamental para obter melhores atividades adesivas, remineralizantes e antibacterianas.

20.
J Endod ; 49(6): 730-734, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-37004792

RESUMEN

INTRODUCTION: This report aims to communicate the discovery of a novel anatomy in a 3-rooted maxillary second molar, named as palato-mesiobuccal canal. METHODS: The tooth selected for this report was found incidentally as a result of a study on extracted maxillary molars that was being conducted for an unrelated purpose and involved hundreds of teeth. This 3-rooted maxillary second molar was scanned using a micro-computed tomography device set at a pixel size of 13.68 µm. The images were reconstructed with previously tested parameters resulting in the acquisition of 1655 axial cross-sections. Three-dimensional (3D) models of the internal and external anatomies were generated in Standard Tessellation Language (STL) format and were texturized to simulate the pulp tissue. The inner structure of the tooth was analyzed through the axial cross sections and the 3D volume was qualitatively evaluated. RESULTS: The analysis of the 3D models revealed that the maxillary second molar under examination has 3 independent roots and 4 root canals. Each root (mesiobuccal, distobuccal, and palatal) contains 1 canal, while the fourth canal follows a unique path, originating in the coronal third of the palatal canal and proceeding in a buccal direction ultimately exiting through an independent foramen at the apex of the mesiobuccal root, near the mesiobuccal canal. CONCLUSIONS: This brief communication reports the discovery of a novel anatomy in a 3-rooted maxillary second molar, named as palato-mesiobuccal canal, and provides important insights into the complexity of the root canal system in this group of teeth.


Asunto(s)
Cavidad Pulpar , Maxilar , Cavidad Pulpar/diagnóstico por imagen , Cavidad Pulpar/anatomía & histología , Microtomografía por Rayos X , Maxilar/diagnóstico por imagen , Diente Molar/diagnóstico por imagen , Diente Molar/anatomía & histología , Tratamiento del Conducto Radicular , Raíz del Diente/diagnóstico por imagen , Raíz del Diente/anatomía & histología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA