Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 30
Filtrar
1.
Rev. cir. traumatol. buco-maxilo-fac ; 23(2): 8-16, abr./jun 2023. ilus, tab
Artículo en Inglés | LILACS, BBO - Odontología | ID: biblio-1537341

RESUMEN

Introduction: The intentionally exposed polypropylene (PP) membrane has been proposed for guided bone regeneration (GBR) of the alveo lar bone after extraction; however, there are biological limitations to this proposal. This study aimed to describe the effects of the PP membrane on neo-osteogenesis after tooth extraction, comparing to intentionally ex posed and primary soft tissue coverage techniques. Methodology: This clinical trial followed the TIDieR checklist and guide. Clinical and histo logical parameters of alveolar repair were compared between groups: 1 (control group), without regenerative procedure; 2, GBR; and 3, inten tionally exposed membrane. Results: Group 3 showed slight effect on the quality of new bone, compared to the control group. Although the GBR was underestimated by the early exposure of the membrane, alveo lar repair and newly formed bone were superior to the other groups. Poly propylene membrane intentionally exposed compromised the volume density of the immature and mineralized bone matrix, the osteoblast and osteocyte count, and stimulated the granulation tissue formation and local inflammatory infiltrate. Conclusions: Despite the exposure of the PP membrane in GBR, this technique improved the quality of new bone and alveolar repair compared to the surgical technique of intentional exposure and alveolus only sutured.


RESUMEN Introducción: La membrana de polipropileno (PP) intencionalmente expuesta ha sido propuesta para la regeneración ósea guiada (GBR) del hueso alveolar después de la extracción; sin embargo, existen limitaciones biológicas a esta propuesta. Este estudio tuvo como objetivo describir los efectos de la membrana de PP en la neo-osteogénesis después de la extracción del diente, en comparación con las técnicas de cobertura de tejido blando primarias y expuestas intencionalmente. Metodología: Este ensayo clínico siguió la lista de verificación y la guía TIDieR. Se compararon los parámetros clínicos e histológicos de la reparación alveolar entre los grupos: 1 (grupo control), sin procedimiento regenerativo; 2, GBR; y 3, membrana expuesta intencionalmente. Resultados: el grupo 3 mostró un ligero efecto sobre la calidad del hueso nuevo, en comparación con el grupo de control. Aunque la GBR fue subestimada por la exposición temprana de la membrana, la reparación alveolar y el hueso neoformado fueron superiores a los otros grupos. La membrana de polipropileno expuesta intencionalmente comprometió la densidad de volumen de la matriz ósea inmadura y mineralizada, el recuento de osteoblastos y osteocitos, y estimuló la formación de tejido de granulación y el infiltrado inflamatorio local. Conclusiones: A pesar de la exposición de la membrana de PP en GBR, esta técnica mejoró la calidad del hueso nuevo y la reparación alveolar en comparación con la técnica quirúrgica de exposición intencional y alvéolo solo suturado.


Introdução: A membrana de polipropileno (PP) intencionalmente exposta tem sido proposta para regeneração óssea guiada (ROG) do osso alveolar após exodontia; no entanto, existem limitações biológicas a esta proposta. Este estudo teve como objetivo descrever os efeitos da membrana de PP na neo-osteogênese após a extração dentária, comparando com as técnicas de exposição intencional e cobertura primária de tecidos moles. Metodologia: Este ensaio clínico seguiu a lista de verificação e o guia TIDieR. Parâmetros clínicos e histológicos do reparo alveolar foram comparados entre os grupos: 1 (grupo controle), sem procedimento regenerativo; 2, GBR; e 3, membrana intencionalmente exposta. Resultados: O Grupo 3 apresentou leve efeito na qualidade do novo osso, em comparação com o grupo controle. Embora o GBR tenha sido subestimado pela exposição precoce da membrana, o reparo alveolar e o osso neoformado foram superiores aos outros grupos. A exposição intencional da membrana de polipropileno comprometeu a densidade volumétrica da matriz óssea imatura e mineralizada, a contagem de osteoblastos e osteócitos e estimulou a formação de tecido de granulação e infiltrado inflamatório local. Conclusões: Apesar da exposição da membrana PP na ROG, esta técnica melhorou a qualidade do novo osso e da reparação alveolar em comparação com a técnica cirúrgica de exposição intencional e alvéolo apenas suturado.


Asunto(s)
Humanos , Polipropilenos , Regeneración Ósea , Alveolo Dental , Regeneración Tisular Dirigida , Aumento de la Cresta Alveolar
2.
Braz. dent. sci ; 26(3): 1-6, 2023. ilus, tab
Artículo en Inglés | LILACS, BBO - Odontología | ID: biblio-1509829

RESUMEN

Objective: Teeth play a crucial role in masticatory efficiency and esthetic harmony making rehabilitation of partially edentulous patients a challenge because of the limitations of conventional removable partial dentures. As a therapeutic alternative, thermoplastic polymers are used in current dental practice either for practical processing purposes or aesthetics. However, it is recognized that the bond between acrylic resin artificial teeth and thermoplastic polymers has no chemical interaction, and depends on retentive features added to the teeth. This study analyzed the efficacy of two retentive forms of features through compressive strength test and as a secondary outcome, fracture and displacement resistance test. Material and Methods: Three groups of samples each with 14 sets of acrylic teeth were compared when two retentive features, single hole and groove retention, and a control group with teeth without any specific form. The experimental unit consisted of six maxillary anterior teeth, positioned in a linear pattern into a polypropylene block, where each tooth was submitted to a static load until its removal, on a universal testing machine. Results: Those specimens with a groove retention presented larger resistance to displacement when compared to the other groups (p <0.05). This was emphasized by the fracture of the tooth tested, with part of the cervical portion remaining embed in the base, and not its displacement as with (or without) the retentive feature. Conclusion: In this study, the type of retention influenced significantly to a better retention considering teeth and thermoplastic polymer base. The data in this study indicates that a groove placed on the artificial tooth offers significantly better retention efficacy to the point where the displacement was only possible after its fracture (AU)


Objetivo: Os dentes são um fator essencial na eficiência mastigatória. A harmonia estética e a reabilitação dos indivíduos parcialmente dentados tornam-se um desafio, frente às limitações das próteses parciais removíveis convencionais. Como uma alternativa terapêutica, os polímeros termoplásticos são utilizados na odontologia contemporânea, tanto para o seu processamento prático como seu apelo estético. Entretanto, pouco se sabe a respeito da união entre a resina acrílica de dentes artificiais e resinas termoplásticas, assim como a influência dos mecanismos de retenção, uma vez que não há interação química entre eles. O objetivo deste estudo foi analisar duas formas de retenção de dentes de resina acrílica a bases de prótese de material termoplástico, por força compressiva e como desfecho secundário, teste de resistência a fratura e deslocamento dos dentes artificiais. Material e Métodos: O presente estudo analisou dois tipos diferentes de retenções: uma cavidade com único ponto e uma canaleta de mesial a distal; e como grupo controle, dentes colocados sem qualquer recurso específico. A unidade experimental consistiu de seis dentes superiores anteriores, posicionados em linha em um bloco de polipropileno. Em cada dente artificial foi aplicada força até a sua remoção, em uma máquina universal de ensaios. Resultados: Os resultados mostraram que a retenção com canaleta apresentou maior força de deslocamento, quando comparado com os outros grupos (p <0,05). Tal fato foi evidenciado pelo teste de fratura e deslocamento, no qual parte da porção cervical do dente artificial permaneceu unida à base, não ocorrendo o deslocamento com (ou sem) a retenção. Conclusão: Neste estudo, o tipo de retenção influenciou de forma significante a retenção de dentes artificiais de resina acrílica a bases de prótese termoplásticas. Os dados deste estudo indicam que a confecção da retenção em canaleta nos dentes artificiais oferece significante aumento na eficiência da retenção, ao ponto em que o deslocamento do dente ocorreu somente após sua fratura (AU).


Asunto(s)
Polipropilenos , Diente Artificial , Resinas Acrílicas , Dentaduras
3.
Rev. Soc. Bras. Clín. Méd ; 14(4): 195-198, 2016.
Artículo en Portugués | LILACS | ID: biblio-827212

RESUMEN

OBJETIVO: Aferir complicações pós-operatórias imediatas e tardias em pacientes portadores de hérnia inguinal submetidos à correção cirúrgica, comparando a utilização da tela de polipropileno monofilamentar com a tela de polipropileno/poliglecaprone-25. MÉTODOS: Estudo retrospectivo dos pacientes submetidos ao reparo inguinal com uso de tela cirúrgica, avaliando as complicações precoces e tardias por meio de levantamento de prontuários e contato telefônico. Foram utilizadas telas de polipropileno monofilamentar e telas polipropileno com poliglecaprone-25, sendo os pacientes alocados em cada um dos grupos de forma aleatorizada. RESULTADOS: Foram incluídos 114 pacientes no estudo submetidos ao reparo inguinal pela técnica de Lichtenstein. No grupo que utilizou a tela de polipropileno monofilamentar (81,5%), foram identificados quatro pacientes (4,30%) com seroma, dois (2,15%) com hematoma, dois (2,15%) apresentaram infecção de ferida operatória, três (3,22%) apresentaram hipoestesia, nove (9,67%) apresentaram dor ou desconforto crônico na região inguinal e não houve casos de recorrência da hérnia no período. No grupo que utilizou a tela de polipropileno/poliglecaprone-25 (18,5%), foram identificados um paciente (4,76%) com seroma e um (4,76%) com hipoestesia e dois pacientes (9,52%) apresentaram desconforto ou dor crônica. CONCLUSÃO: O reparo inguinal com uso de tela foi o meio mais eficiente para o tratamento da hérnia inguinal apresentando baixos índices de complicação e fácil aplicabilidade O uso das telas de polipropileno/poliglecaprone-25 ainda não está totalmente estabelecido, apresentando taxas globais de complicações iguais às telas de polipropileno monofilamentar.


OBJECTIVE: To assess postoperative early and late complications in patients with inguinal hernia undergoing surgical correction, comparing the use of monofilament polypropylene mesh with polypropylene/poliglecaprone-25 mesh. METHODS: A retrospective study of patients undergoing inguinal repair with the use of surgical mesh, evaluating early and late complications through the analysis of medical records, and telephone contact. Monofilament polypropylene mesh and polypropylene/polyglecaprone-25 mesh were used, with the patients being randomly allocated to each group. RESULTS:The study included 114 patients who underwent inguinal repair through Lichtenstein technique. In the group that used the monofilament polypropylene mesh (81.5%) 4 patients (4.30%) were identified with seroma, 2 patients (2.15%) with hematoma, 2 patients (2.15%) had surgical wound infection, 3 patients (3.22%) had hypoesthesia, 9 patients (9.67%) had chronic pain or discomfort in the groin, and there were no cases of recurrence of hernia in the period. In the group that used the polypropylene/poliglecaprone-25 mesh (18.5%), 1 patient (4.76%) had seroma, 1 patient (4.76%) had hypoesthesia, and 2 patients (9.52%) showed chronic discomfort or pain. CONCLUSION: The inguinal repair with mesh use is the most efficient treatment for inguinal hernia, showing low rate of complications, and being easy to apply. The use of polypropylene/poliglecaprone-25 mesh is not yet fully established, presenting overall rates of complications similar to monofilament polypropylene mesh.


Asunto(s)
Humanos , Masculino , Femenino , Persona de Mediana Edad , Hernia Inguinal/cirugía , Polipropilenos , Mallas Quirúrgicas/estadística & datos numéricos , Resultado del Tratamiento
4.
Rev. bras. cir. plást ; 30(4): 560-566, sep.-dec. 2015. ilus, tab
Artículo en Inglés, Portugués | LILACS | ID: biblio-1400

RESUMEN

Introdução: O retalho transverso do músculo reto abdominal (TRAM) é um método bem estabelecido para reconstrução mamária. Apresenta como principal desvantagem o grande defeito da área doadora, podendo causar fraqueza da parede abdominal, hérnias e abaulamentos. Diversas táticas de fechamento do defeito da área doadora foram descritas, incluindo fechamento direto da aponeurose do músculo reto abdominal e uso de telas de polipropileno. O objetivo deste estudo foi avaliar os índices de abaulamento e hérnia no pós-operatório de TRAM utilizando a tática cirúrgica de fechamento da área doadora com duas telas de polipropileno. Métodos: Estudo prospectivo em 24 pacientes submetidos à reconstrução mamária unilateral com TRAM monopediculado ou bipediculado e reparo da área doadora com duas telas de polipropileno. Os pacientes foram avaliados quanto à incidência de hérnia e abaulamento no pós-operatório de 3, 6 e 12 meses. Resultados: Ocorreu um caso (4,16%) de abaulamento abdominal e nenhum caso de hérnia. Não houve casos de infecção ou extrusão da tela. Conclusão: O uso de duas telas de polipropileno na área doadora do TRAM propiciou baixa incidência de hérnias e abaulamentos abdominais.


Introduction: The transverse rectus abdominis myocutaneous flap is a well stablished surgery for breast reconstruction. Its main disadvantage is a large defect in its donor site, leading to weakness in the abdominal wall. Many surgical tactics has been described to address the donor site defect, including direct closure of the muscular aponeurotic and use of polypropylene mesh. The purpose of this study was to assess abdominal hernia and bulge after TRAM flap breast reconstruction using two layers of polypropylene mesh in the donor site defect. Methods: Prospective study in 24 patients who had unilateral TRAM flap breast reconstruction with two layers of polypropylene mesh to close the donor site defect. The patients were evaluated in 3.6 and 12 months of postoperative time for incidence of abdominal hernia and bulge. Results: It was observed one case of abdominal bulge (4.16%) and no case of abdominal hernia. There were no cases of mesh infection or extrusion. Conclusion: The use of two layers of polypropylene mesh in the donor site defect of TRAM flap breast reconstruction resulted in low incidence of abdominal hernia and bulge.


Asunto(s)
Femenino , Adulto , Persona de Mediana Edad , Historia del Siglo XXI , Polipropilenos , Colgajos Quirúrgicos , Mama , Estudios Prospectivos , Mamoplastia , Recto del Abdomen , Procedimientos de Cirugía Plástica , Estudio de Evaluación , Pared Abdominal , Glándulas Mamarias Humanas , Hernia Abdominal , Polipropilenos/uso terapéutico , Colgajos Quirúrgicos/cirugía , Mama/cirugía , Mamoplastia/métodos , Recto del Abdomen/cirugía , Procedimientos de Cirugía Plástica/métodos , Pared Abdominal/cirugía , Glándulas Mamarias Humanas/cirugía , Hernia Abdominal/cirugía
5.
Rev. Col. Bras. Cir ; 41(2): 82-86, Mar-Apr/2014. tab, graf
Artículo en Inglés | LILACS | ID: lil-711817

RESUMEN

OBJECTIVE: To evaluate the results of subcostal incisional hernia repair using polypropylene mesh, the technical aspects of musculo-aponeurotic reconstruction, routine fixation of supra-aponeurotic mesh and follow-up for five years. METHODS: We conducted a retrospective study that assessed 24 patients undergoing subcostal incisional hernia repair with use of polypropylene mesh; 15 patients (62.5%) were female; ages ranged from 33 to 82, and 79.1% had comorbidities. RESULTS: Early complications: three cases (12.5%) of wound infection, three cases (12.5%) of seroma, one case (4.1%) of hematoma; and one case (4.1%) of wound dehiscence. Late complications occurred in one case (4.1%) of hernia recurrence attributed to technical failure in the fixation of the mesh and in one case (4.1%) of chronic pain. There were no cases of exposure or rejection of the mesh. CONCLUSION: The subcostal incisional hernia, though not very relevant, requires adequate surgical treatment. Its surgical correction involves rebuilding the muscle-aponeurotic defect, supra-aponeurotic fixation of polypropylene mesh, with less complexity and lower rates of complications and recurrences. .


OBJETIVO: avaliar os resultados da herniorrafia incisional subcostal com uso de tela de polipropileno, quanto aos aspectos técnicos da reconstrução músculo-aponeurótica, da fixação rotineira de tela supra-aponeurótica e o seguimento por cinco anos. MÉTODOS: Estudo retrospectivo no qual foram avaliados 24 pacientes submetidos à herniorrafias incisionais subcostais com uso da tela de polipropileno, sendo 15 pacientes (62,5%) do sexo feminino, com faixa etária variando de 33 a 82 anos, e 79,1% apresentavam comorbidades. RESULTADOS: Complicações precoces: três casos de infecção de ferida operatória (12,5%), três casos de seromas (12,5%), um caso de hematoma (4,1%); um caso de deiscência da ferida operatória (4,1%). Complicações tardias, houve um caso de recidiva herniária (4,1%), atribuído à falha técnica na fixação da tela e um caso de dor crônica (4,1%). Não houve nenhum caso de exposição ou rejeição da tela. CONCLUSÃO: A hérnia incisional subcostal, embora pouco prevalente, requer tratamento cirúrgico adequado. Sua correção cirúrgica implica em reconstrução músculo-aponeurótica do defeito, seguido de fixação de tela de polipropileno supra-aponeurótica, com menor complexidade e baixos índices de complicações e recidivas. .


Asunto(s)
Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Hernia Incisional/cirugía , Polipropilenos , Mallas Quirúrgicas , Estudios de Seguimiento , Estudios Retrospectivos , Costillas , Factores de Tiempo , Resultado del Tratamiento
6.
Acta cir. bras. ; 27(10): 671-680, 2012. ilus, tab
Artículo en Inglés | VETINDEX | ID: vti-14221

RESUMEN

PURPOSE: To evaluate, in large abdominal wall defects surgically shaped in rats, if a synthetic polypropylene nonwoven prosthesis could be used as a therapeutic option to conventional polypropylene mesh. METHODS: Twenty four (24) Wistar rats were enrolled into three groups. Group 1 (Simulation group) with an abdominal wall defect of 3 X 3 left untreated and Groups 2 and 3, respectively treated with a conventional polypropylene mesh and a polypropylene nonwoven (NWV) prosthesis to cover the breach. At the 45th postoperatively day, adhesion (area and strength) and vascularization of Groups 2 and 3 were evaluated. The histological preparations with Hematoxylin-Eosin, Tricromium of Masson, Pricrosirius red and polarization with birefringence, and also the structural analysis of the prostheses carried on by Thermogravimetry and Differential Scanning Calorimetry were also assessed. RESULTS: There were no significant differences between the Groups 2 and 3. CONCLUSION: In rats, the polypropylene nonwoven prosthesis showed to be safe and has to be considered as an alternative to conventional mesh manufactured by weaving in the treatment of great defects of the abdominal wall.(AU)


OBJETIVO: Avaliar, em grandes defeitos da parede abdominal produzidos cirurgicamente em ratos, se uma prótese sintética de polipropileno sem tecelagem poderia ser utilizada como alternativa terapêutica às telas convencionais de polipropileno. MÉTODOS: Vinte e quatro ratos foram distribuídos em três grupos numericamente iguais. Grupo 1 (Simulação), no qual um defeito de 3 x 3 cm foi constituído na parede abdominal sem tratamento. Uma tela convencional de polipropileno e uma tela de polipropileno sem tecelagem foram colocadas para cobrir o defeito, nos grupos 2 e 3 , respectivamente. No 45º dia de pós-operatório foram avaliadas a área e a força das aderências, além da vascularização. Também foram analisados os preparados histológicos com Hematoxilina-eosina, Tricrômio de Masson e Picrosirius com polarização e birrefringência, além de efetuada análise estrutural da prótese mediante Termogavimetria e Colorimetria Exploratória Diferencial. RESULTADOS: Não houve diferença significante entre os grupos 2 e 3. CONCLUSÃO: Em ratos, a tela de polipropileno sem tecelagem mostrou ser segura e deve ser considerada como uma alternativa à tela convencional manufaturada por tecelagem, no tratamento dos grandes defeitos da parede abdominal.(AU)


Asunto(s)
Ratas , Mallas Quirúrgicas , Materiales Biocompatibles , Hernia Abdominal/cirugía , Pared Abdominal/cirugía , Modelos Animales , Adherencias Tisulares/prevención & control , Prótesis e Implantes , Abdomen/cirugía , Abdomen/patología
7.
Acta cir. bras ; Acta cir. bras;27(10): 671-680, Oct. 2012. ilus, tab
Artículo en Inglés | LILACS | ID: lil-650555

RESUMEN

PURPOSE: To evaluate, in large abdominal wall defects surgically shaped in rats, if a synthetic polypropylene nonwoven prosthesis could be used as a therapeutic option to conventional polypropylene mesh. METHODS: Twenty four (24) Wistar rats were enrolled into three groups. Group 1 (Simulation group) with an abdominal wall defect of 3 X 3 left untreated and Groups 2 and 3, respectively treated with a conventional polypropylene mesh and a polypropylene nonwoven (NWV) prosthesis to cover the breach. At the 45th postoperatively day, adhesion (area and strength) and vascularization of Groups 2 and 3 were evaluated. The histological preparations with Hematoxylin-Eosin, Tricromium of Masson, Pricrosirius red and polarization with birefringence, and also the structural analysis of the prostheses carried on by Thermogravimetry and Differential Scanning Calorimetry were also assessed. RESULTS: There were no significant differences between the Groups 2 and 3. CONCLUSION: In rats, the polypropylene nonwoven prosthesis showed to be safe and has to be considered as an alternative to conventional mesh manufactured by weaving in the treatment of great defects of the abdominal wall.


OBJETIVO: Avaliar, em grandes defeitos da parede abdominal produzidos cirurgicamente em ratos, se uma prótese sintética de polipropileno sem tecelagem poderia ser utilizada como alternativa terapêutica às telas convencionais de polipropileno. MÉTODOS: Vinte e quatro ratos foram distribuídos em três grupos numericamente iguais. Grupo 1 (Simulação), no qual um defeito de 3 x 3 cm foi constituído na parede abdominal sem tratamento. Uma tela convencional de polipropileno e uma tela de polipropileno sem tecelagem foram colocadas para cobrir o defeito, nos grupos 2 e 3 , respectivamente. No 45º dia de pós-operatório foram avaliadas a área e a força das aderências, além da vascularização. Também foram analisados os preparados histológicos com Hematoxilina-eosina, Tricrômio de Masson e Picrosirius com polarização e birrefringência, além de efetuada análise estrutural da prótese mediante Termogavimetria e Colorimetria Exploratória Diferencial. RESULTADOS: Não houve diferença significante entre os grupos 2 e 3. CONCLUSÃO: Em ratos, a tela de polipropileno sem tecelagem mostrou ser segura e deve ser considerada como uma alternativa à tela convencional manufaturada por tecelagem, no tratamento dos grandes defeitos da parede abdominal.


Asunto(s)
Animales , Femenino , Ratas , Pared Abdominal/cirugía , Materiales Biocompatibles/uso terapéutico , Hernia Ventral/cirugía , Prótesis e Implantes , Polipropilenos/uso terapéutico , Mallas Quirúrgicas , Modelos Animales de Enfermedad , Ensayo de Materiales , Implantación de Prótesis/métodos , Ratas Wistar , Adherencias Tisulares , Resultado del Tratamiento
8.
Rev. Col. Bras. Cir ; 39(3): 195-200, maio-jun. 2012. ilus
Artículo en Portugués | LILACS | ID: lil-643147

RESUMEN

OBJETIVO: Verificar a eficácia e complicações da correção cirúrgica de hérnias incisionais por enxerto da tela de polipropileno envolta por tecido fibroso, em comparação com a tela de polipropileno. MÉTODOS: Foram utilizados 25 ratos Wistar machos e fêmeas, distribuídos em dois grupos: controle e experimento. O grupo experimento, com 15 animais, foi submetido ao implante da tela em seu tecido subcutâneo. Após 21 dias, a tela foi removida e serviu para correção de uma hérnia abdominal induzida. Os animais foram eutanasiados após 21 dias e submetidos à análise macroscópica, tensional e microscópica. O grupo controle, foi submetido ao reparo da hérnia abdominal com a tela de polipropileno. RESULTADOS: Observou-se diferença significativa em relação à análise macroscópica de aderências. O grupo controle obteve maior grau de aderências em relação ao experimento (p= 0,003). Não foi possível afirmar que houve diferença significativa em relação à análise de força tensional e microscopia. CONCLUSÃO: A tela de polipropileno envolta por tecido fibroso mostrou-se eficaz na correção das hérnias abdominais induzidas, com menor grau de aderências macroscópicas quando comparada à tela de polipropileno.


OBJECTIVE: To assess the efficacy and complications of surgical repair of incisional hernias by grafting of polypropylene mesh surrounded by fibrous tissue, compared to polypropylene mesh. METHODS: twenty-five male and female Wistar rats were divided into two groups: control and experimental. The 15 animals of the experimental group underwent implantation of the mesh in the subcutaneous tissue. After 21 days, the screen was removed and served to correct an induced abdominal hernia. The animals were euthanized after 21 days and submitted to macroscopic, microscopic and tension analises. The control group had undergone usual abdominal hernia repair with polypropylene mesh. RESULTS: There was a significant difference in macroscopic adhesions. The control group had a higher degree of adhesions when compared to the experiment ones (p = 0.003). We could not determine whether there were significant differences in tensile strength and microscopy. CONCLUSION: The polypropylene mesh surrounded by fibrous tissue was effective in the correction of induced abdominal hernias, with a lower degree of macroscopic adhesions when compared to polypropylene mesh.


Asunto(s)
Animales , Masculino , Ratas , Hernia Ventral/cirugía , Herniorrafia/métodos , Mallas Quirúrgicas , Diseño de Equipo , Polipropilenos , Ratas Wistar , Mallas Quirúrgicas/efectos adversos
9.
Rev. Col. Bras. Cir ; 39(3): 201-206, maio-jun. 2012. ilus, tab
Artículo en Portugués | LILACS | ID: lil-643148

RESUMEN

OBJETIVO: Comparar as aderências entre dois grupos de ratas Wistar submetidas à colocação intraperitoneal da tela de polipropileno e malha leve de polipropileno revestida com ácido graxo ômega-3. MÉTODOS: Foram utilizadas 27 ratas Wistar randomizadas em três grupos. No grupo 0 não houve colocação de prótese, no grupo 1 houve implantação da prótese de polipropileno e no grupo 2, implantação de prótese de polipropileno revestida com ácido graxo ômega-3. Foi avaliadas a presença de aderências, grau, força de ruptura, percentual de área recoberta e retração das telas aferidas. RESULTADOS: O grupo 0 não apresentou aderência. Os grupos 1 e 2 apresentaram aderência na superfície da prótese, omento, fígado e alça intestinal. Foram encontradas aderências grau 1 e 2 em 100% do grupo polipropileno revestida com ácido graxo ômega-3 e em 60% do grupo polipropileno. As demais eram aderências grau 3, e diferiram significativamente entre os grupos (p< 0,001). A força de ruptura da aderência na tela polipropileno revestida com ácido graxo ômega-3 foi significativamente maior do que na tela de polipropileno (p= 0,016). Não houve diferença na retração das telas ou superfície acometida pelas telas. A análise da tela revestida com ácido graxo ômega-3 demonstrou distribuição preferencialmente nas bordas em relação ao polipropileno, com predomínio no centro. CONCLUSÃO: O tipo de aderência, percentual de superfície acometida e retração não foram significativamente diferentes entre as telas. A tela de baixo peso apresentou menor grau de aderências, e, estas, necessitaram força maior para ruptura, possivelmente pelo predomínio de sua ocorrência nas bordas da tela.


OBJECTIVE: To compare intraperitoneal adhesion formation with placement of polypropylene mesh and use of lightweight polypropylene mesh coated with omega-3 fatty in rats. METHODS: Twenty-seven Wistar rats were randomized into three groups. In group 0 no mesh was placed; in group 1 we implanted a polypropylene mesh; and in group 2 there was implantation of a polypropylene mesh coated with omega-3 fatty acid. We evaluated adhesions presence and degree, breaking strength, percentage of area covered and retraction of the implanted meshes. RESULTS: Group 0 had no adhesion. Groups 1 and 2 showed adhesions on the surface of the mesh, omentum, liver and intestinal loops. There were grades 1 and 2 adhesions in 100% of the polypropylene coated group and in 60% of the polypropylene group. The remaining were grade 3 adhesions, and differed significantly between groups (p <0.001). The breaking strength of adhesions on the polypropylene coated group was significantly higher than with the polypropylene alone (p = 0.016). There was no difference in mesh retraction or area covered by the mesh. The analysis of the mesh coated with omega-3 fatty acid distribution showed adhesions preferentially located at the edges when compared to polypropylene, predominantly in the center. CONCLUSION: The type of adhesions, percentage of surface affected and retraction were not significantly different between meshes. The fatty acids coated mesh had a lower degree of adhesions and these required a greater force to rupture, possibly by their occurrence at the edges of the mesh.


Asunto(s)
Animales , Ratas , Materiales Biocompatibles Revestidos , Polipropilenos , Enfermedades Peritoneales/etiología , Mallas Quirúrgicas/efectos adversos , Diseño de Equipo , Ratas Wistar , Adherencias Tisulares/etiología
10.
Acta cir. bras ; Acta cir. bras;27(4): 300-305, Apr. 2012. ilus
Artículo en Inglés | LILACS | ID: lil-622354

RESUMEN

PURPOSE: To evaluate the healing process of a defect in the ventral abdominal wall of rats, comparing the polypropylene and polypropylene/poliglecaprone meshes on the 30th and 60th postoperative day. METHODS: Thirty two Wistar rats were submitted to a ventral abdominal wall defect, with integrity of the parietal peritoneum. In the repair, were used polypropylene (group A) and polypropylene/poliglecaprone (group B) meshes. The groups were subdivided into four subgroups of eight animals euthanized on the 30th (A30 and B30) and 60th postoperative day (A60 and B60). Fragments of the abdominal wall of the animals were submitted to macroscopic, tensiometric and histological evaluations. RESULTS: The tensiometry on subgroup A30 showed a mean average break point of 0.78 MPa and in A60, 0.66 Mpa. In subgroup B30 it was 0.84 MPa and in B60, 1.27 Mpa. The score of the inflammatory process showed subacute phase on A30 and B30 sub-groups and chronic inflammatory process in subgroups A30 and 60B. CONCLUSIONS: The tensile strength was higher on the wall repaired by polypropylene/poliglecaprone mesh in the 60th post-operative day. Histology showed higher concentration of fibrosis on the surface of the polypropylene mesh with a tendency to encapsulation. In polypropylene/poliglecaprone subgroups the histology showed higher concentration of fibrosis on the surface of mesh filaments.


OBJETIVO: Avaliar a cicatrização de um defeito, na parede abdominal ventral de ratos, comparando-se as telas de polipropileno e polipropileno/poliglecaprone no 30º e 60º dia do pós-operatório. MÉTODOS: Trinta e dois ratos Wistar foram submetidos à produção de defeito na parede abdominal ventral, com integridade do peritônio parietal. Na correção foram utilizadas as telas de polipropileno (grupo A) e polipropileno/poliglecaprone (grupo B). Houve subdivisão em quatro subgrupos (A30, A60, B30 e B60) de oito animais que foram submetidos à eutanásia no 30º e 60º dia do pós-operatório. Fragmentos da parede abdominal foram submetidos à análise macroscópica, tensiométrica e histológica. RESULTADOS: A tensiometria no subgrupo A30 mostrou tensão média de ruptura de 0,78 Mpa e no subgrupo A60 de 0,66 MPa. No subgrupo B30 foi de 0,84 MPa e no B60 de 1,27 MPa. O escore do processo inflamatório mostrou fase subaguda nos subgrupos A30 e B30 e processo inflamatório crônico no subgrupo A60 e B60. CONCLUSÕES: A resistência à tensão foi maior na parede reparada pela tela de polipropileno/poliglecaprone no 60º dia pós-operatório. Na análise histológica houve maior concentração da fibrose na superfície da tela de polipropileno com tendência ao encapsulamento. Nos subgrupos polipropileno/poliglecaprone a análise histológica mostrou maior fibrose entre os filamentos da tela.


Asunto(s)
Animales , Masculino , Ratas , Pared Abdominal/cirugía , Materiales Biocompatibles , Dioxanos , Poliésteres , Polipropilenos , Mallas Quirúrgicas , Pared Abdominal/patología , Microscopía Electrónica de Rastreo , Ratas Wistar , Factores de Tiempo
11.
Acta cir. bras ; Acta cir. bras;27(3): 251-255, Mar. 2012. ilus, tab
Artículo en Inglés | LILACS | ID: lil-617965

RESUMEN

PURPOSE: To compare sutures with polypropylene and poliglecaprone 25 after partial cecotomy in rats. METHODS: Thirty six rats divided into two groups, A and B, of 18 animals; each group was also divided into three subgroups of six animals sacrificed at 4th, 7th and 14th days after surgery. Were studied the mortality, morbidity, complications attributable to sutures, macroscopy, optical microscopy and measurement of hydroxyproline at the level of the suture. RESULTS: There were no deaths or wound complications such as hematoma, seroma, abscess, evisceration or eventration. On microscopic evaluation reepithelization, coaptation and inflammation in both groups did not differ significantly. The average rate of tissue hydroxyproline found in the samples on the 4th day after surgery, was 21.38 mg/g tissue for group A and 16.68 mg/g for group B; on day 7 after surgery, the average was 15.64 mg/g tissue for group A and 26.53 mg/g for group B; on day 14, the average was 8.09 mg/g tissue for group A and 25.07 mg/g for group B. CONCLUSION: There were no differences on clinical evolution, macroscopic aspect, microscopic data and hydroxyproline concentration on both sutures.


OBJETIVO: Comparar a sutura com fio de polipropileno e poliglecaprone 25 após cecotomia parcial em ratos. MÉTODOS: Trinta e seis ratos foram distribuídos em dois grupos A e B de 18 animais, e cada grupo foi dividido em três subgrupos de seis, sacrificados no 4º, 7º e 14º dias do pós-operatório. Estudou-se a mortalidade, morbidade, complicações atribuíveis às suturas, macroscopia, microscopia ótica e dosagem de hidroxiprolina no nível da sutura. RESULTADOS: Não houve mortalidade ou complicações da ferida operatória como hematoma, seroma, abscesso, evisceração ou eventração. Na avaliação microscópica os critérios de re-epitelização, coaptação e processo inflamatório ambos os grupos não apresentaram diferença significativa. A taxa tecidual média da hidroxiprolina encontrada nas amostras no 4º dia de pós-operatório foi de 21,38 mg/g de tecido para o grupo A e 16,68 mg/g para o grupo B; no 7º dia a média foi de 15,64 mg/g de tecido para o grupo A e 26,53 mg/g para o grupo B; no 14º dia ela foi de 8,09 mg/g de tecido para o grupo A e 25,07 mg/g para o grupo B. CONCLUSÃO: Não houve diferença estatística entre a evolução clínica, avaliação macroscópica, microscopia e dosagem de hidroxiprolina entre as suturas realizadas com os fios estudados.


Asunto(s)
Animales , Masculino , Ratas , Ciego/cirugía , Dioxanos/efectos adversos , Hidroxiprolina/análisis , Polipropilenos , Poliésteres/efectos adversos , Técnicas de Sutura/instrumentación , Ciego/ultraestructura , Modelos Animales , Periodo Posoperatorio , Distribución Aleatoria , Ratas Wistar , Suturas/efectos adversos
12.
Acta cir. bras. ; 27(4): 300-305, 2012. ilus
Artículo en Inglés | VETINDEX | ID: vti-3992

RESUMEN

PURPOSE: To evaluate the healing process of a defect in the ventral abdominal wall of rats, comparing the polypropylene and polypropylene/poliglecaprone meshes on the 30th and 60th postoperative day. METHODS: Thirty two Wistar rats were submitted to a ventral abdominal wall defect, with integrity of the parietal peritoneum. In the repair, were used polypropylene (group A) and polypropylene/poliglecaprone (group B) meshes. The groups were subdivided into four subgroups of eight animals euthanized on the 30th (A30 and B30) and 60th postoperative day (A60 and B60). Fragments of the abdominal wall of the animals were submitted to macroscopic, tensiometric and histological evaluations. RESULTS: The tensiometry on subgroup A30 showed a mean average break point of 0.78 MPa and in A60, 0.66 Mpa. In subgroup B30 it was 0.84 MPa and in B60, 1.27 Mpa. The score of the inflammatory process showed subacute phase on A30 and B30 sub-groups and chronic inflammatory process in subgroups A30 and 60B. CONCLUSIONS: The tensile strength was higher on the wall repaired by polypropylene/poliglecaprone mesh in the 60th post-operative day. Histology showed higher concentration of fibrosis on the surface of the polypropylene mesh with a tendency to encapsulation. In polypropylene/poliglecaprone subgroups the histology showed higher concentration of fibrosis on the surface of mesh filaments.(AU)


OBJETIVO: Avaliar a cicatrização de um defeito, na parede abdominal ventral de ratos, comparando-se as telas de polipropileno e polipropileno/poliglecaprone no 30º e 60º dia do pós-operatório. MÉTODOS: Trinta e dois ratos Wistar foram submetidos à produção de defeito na parede abdominal ventral, com integridade do peritônio parietal. Na correção foram utilizadas as telas de polipropileno (grupo A) e polipropileno/poliglecaprone (grupo B). Houve subdivisão em quatro subgrupos (A30, A60, B30 e B60) de oito animais que foram submetidos à eutanásia no 30º e 60º dia do pós-operatório. Fragmentos da parede abdominal foram submetidos à análise macroscópica, tensiométrica e histológica. RESULTADOS: A tensiometria no subgrupo A30 mostrou tensão média de ruptura de 0,78 Mpa e no subgrupo A60 de 0,66 MPa. No subgrupo B30 foi de 0,84 MPa e no B60 de 1,27 MPa. O escore do processo inflamatório mostrou fase subaguda nos subgrupos A30 e B30 e processo inflamatório crônico no subgrupo A60 e B60. CONCLUSÕES: A resistência à tensão foi maior na parede reparada pela tela de polipropileno/poliglecaprone no 60º dia pós-operatório. Na análise histológica houve maior concentração da fibrose na superfície da tela de polipropileno com tendência ao encapsulamento. Nos subgrupos polipropileno/poliglecaprone a análise histológica mostrou maior fibrose entre os filamentos da tela.(AU)


Asunto(s)
Animales , Ratas/clasificación , Hernia Abdominal/veterinaria , Mallas Quirúrgicas , Polipropilenos
13.
Acta cir. bras. ; 27(3): 251-255, 2012. ilus, tab
Artículo en Inglés | VETINDEX | ID: vti-3983

RESUMEN

PURPOSE: To compare sutures with polypropylene and poliglecaprone 25 after partial cecotomy in rats. METHODS: Thirty six rats divided into two groups, A and B, of 18 animals; each group was also divided into three subgroups of six animals sacrificed at 4th, 7th and 14th days after surgery. Were studied the mortality, morbidity, complications attributable to sutures, macroscopy, optical microscopy and measurement of hydroxyproline at the level of the suture. RESULTS: There were no deaths or wound complications such as hematoma, seroma, abscess, evisceration or eventration. On microscopic evaluation reepithelization, coaptation and inflammation in both groups did not differ significantly. The average rate of tissue hydroxyproline found in the samples on the 4th day after surgery, was 21.38 mg/g tissue for group A and 16.68 mg/g for group B; on day 7 after surgery, the average was 15.64 mg/g tissue for group A and 26.53 mg/g for group B; on day 14, the average was 8.09 mg/g tissue for group A and 25.07 mg/g for group B. CONCLUSION: There were no differences on clinical evolution, macroscopic aspect, microscopic data and hydroxyproline concentration on both sutures.(AU)


OBJETIVO: Comparar a sutura com fio de polipropileno e poliglecaprone 25 após cecotomia parcial em ratos. MÉTODOS: Trinta e seis ratos foram distribuídos em dois grupos A e B de 18 animais, e cada grupo foi dividido em três subgrupos de seis, sacrificados no 4º, 7º e 14º dias do pós-operatório. Estudou-se a mortalidade, morbidade, complicações atribuíveis às suturas, macroscopia, microscopia ótica e dosagem de hidroxiprolina no nível da sutura. RESULTADOS: Não houve mortalidade ou complicações da ferida operatória como hematoma, seroma, abscesso, evisceração ou eventração. Na avaliação microscópica os critérios de re-epitelização, coaptação e processo inflamatório ambos os grupos não apresentaram diferença significativa. A taxa tecidual média da hidroxiprolina encontrada nas amostras no 4º dia de pós-operatório foi de 21,38 mg/g de tecido para o grupo A e 16,68 mg/g para o grupo B; no 7º dia a média foi de 15,64 mg/g de tecido para o grupo A e 26,53 mg/g para o grupo B; no 14º dia ela foi de 8,09 mg/g de tecido para o grupo A e 25,07 mg/g para o grupo B. CONCLUSÃO: Não houve diferença estatística entre a evolução clínica, avaliação macroscópica, microscopia e dosagem de hidroxiprolina entre as suturas realizadas com os fios estudados.(AU)


Asunto(s)
Animales , Ratas/clasificación , Técnicas de Sutura/veterinaria , Ciego/anatomía & histología , Polipropilenos/efectos adversos , Anastomosis Quirúrgica/veterinaria
14.
Rev. Col. Bras. Cir ; 38(1): 24-27, jan.-fev. 2011. ilus, tab
Artículo en Portugués | LILACS | ID: lil-584123

RESUMEN

OBJETIVO: Aferir complicações pós-operatórias imediatas e tardias em pacientes portadores de hérnia inguinal, submetidos à correção cirúrgica pela técnica de Gilbert1, com utilização do Sistema Prolene de Hérnia (SPH). MÉTODOS: Foram pesquisados todos os pacientes submetidos à herniorrafia inguinal com tela PHS no Hospital São Lucas da PUCRS no período de janeiro de 2001 até ourubro de 2006. As informações foram coletadas de modo retrospectivo, através de contato telefônico e revisão de prontuários. O protocolo de coleta de dados contemplou os aspectos epidemiológicos, bem como as complicações imediatas e tardias. RESULTADOS: Foram incluídos 96 pacientes. Foram identificadas seis (6,25 por cento) complicações, em pacientes distintos; nenhuma complicação com óbito. Dois pacientes (2,08 por cento) apresentaram seroma; hematoma foi identificado em um paciente (1,04 por cento); um paciente (1,04 por cento) apresentou infecção de ferida operatória. Dois pacientes (2,08 por cento) apresentaram edema escrotal. Após seguimento médio de 49,25 meses (16-86,12) dois pacientes (2,08 por cento) apresentaram dor crônica e um paciente (1,04 por cento) apresentou recorrência, com vinte e seis meses de pós-operatório. CONCLUSÃO: O reparo de hérnias inguinais com tela PHS é um método seguro, eficaz, facilmente reprodutível e com baixas taxas de complicações, recorrência ou sintomas em longo prazo.


OBJECTIVE: To assess immediate postoperative and late complications in patients with inguinal hernia undergoing surgical correction by Gilbert¹ technique, using the Prolene Hernia System (HPS). METHODS: We surveyed all patients undergoing inguinal hernia repair with PHS mesh at The Sao Lucas Hospital - PUCRS, from January 2001 to october 2006. Information was retrospectively collected through telephone calls and chart review. The protocol for data collection included epidemiological aspects, as well as immediate and late complications. RESULTS: ninety-six patients were enrolled. We identified six (6.25 percent) complications in different patients, none of which resulting in death. Two patients (2.08 percent) had seroma; hematoma was identified in one patient (1.04 percent); one patient (1.04 percent) had wound infection. Two patients (2.08 percent) had scrotal edema. After a mean follow up of 49.25 months (range 16 to 86.12) two patients (2.08 percent) had chronic pain and one patient (1.04 percent) had hernia recurrence twenty-six months after surgery. CONCLUSION: The repair of inguinal hernia with PHS is a safe, effective and reproducible method, with low complication and recurrence rates or long term symptoms.


Asunto(s)
Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Adulto Joven , Hernia Inguinal/cirugía , Polipropilenos , Mallas Quirúrgicas , Diseño de Equipo , Polipropilenos/efectos adversos , Complicaciones Posoperatorias/epidemiología , Estudios Retrospectivos , Mallas Quirúrgicas/efectos adversos , Procedimientos Quirúrgicos Operativos/efectos adversos , Procedimientos Quirúrgicos Operativos/métodos
15.
Acta cir. bras. ; 25(5): 423-427, Sept.-Oct. 2010. tab
Artículo en Inglés | VETINDEX | ID: vti-7747

RESUMEN

PURPOSE: To compare two different incisional hernia repair techniques (repair with a polypropylene mesh reinforcement on the peritonium-aponeurosis versus polypropylene mesh sutured to the borders of the hernial ring as a bridge) in rabbits. METHODS: Incisional hernia was experimentally developed through a 4-cm median incision in 60 rabbits. After 30 days, half of the animals were operated for primary wall closure and placement of a polypropylene mesh reinforcement, while the other half had a polypropylene mesh sutured to the borders of the hernial ring as a bridge. Clinical development, scar breaking strength, as well as gross, microscopic and morphometric parameters were evaluated in all animals 30, 60, and 90 days after repair. RESULTS: No significant differences in breaking strength or histological parameters were observed between groups at any time point studied. No statistical difference regarding complications was detected, although denser and firmer adhesions to the abdominal wall were seen after the mesh was placed as a " bridge" . CONCLUSIONS: No significant differences between the incisional hernia repair techniques assessed were observed regarding breaking strength, and histological and morphometric parameters. The number of complications was similar in both study groups. However, adhesion of abdominal cavity organs to the scar area was much denser after the placement of a mesh to bridge the defect.(AU)


OBJETIVO: Comparar duas técnicas de tratamento da hérnia incisional em coelhos utilizando a tela de polipropileno apoiando um reforço peritônio - aponeurótico ou suturada nas bordas do anel herniário 'em ponte" . MÉTODOS: Foram operados 60 coelhos para a produção de hérnia incisional, em uma incisão mediana de 4 centímetros. Após 30 dias, metade dos animais foram operados com o fechamento primário da parede, com colocação de uma tela de polipropileno apoiando o reforço e a outra metade dos animais com a colocação da tela suturada nas bordas do anel herniário " em ponte" . Os animais foram avaliados com 30 (M1), 60 (M2)e 90 (M3) dias de pós-operatório. Os parâmetros analisados foram a evolução clínica, análise da força de ruptura da cicatriz, estudo macroscópico, análise microscópica e morfométrica. RESULTADOS: Não foram observadas diferenças significantes com relação a força de ruptura e estudos histológicos nos dois grupos e vários momentos estudados. Não houve diferença estatística com relação às complicações, embora os animais que receberam a tela " em ponte" tiveram aderências mais firmes e intensas à parede abdominal. CONCLUSÕES: As duas técnicas utilizadas para correção da hérnia incisional em coelhos não mostraram diferenças significantes quanto a força de ruptura, análise histológica e morfométrica. O número de complicações foi semelhante, porém a aderência de órgãos da cavidade abdominal à área de cicatriz foi muito mais intensa no grupo em que a tela foi colocada " em ponte" .(AU)


Asunto(s)
Animales , Conejos , Hernia Ventral/rehabilitación , Hernia Ventral/cirugía , Mallas Quirúrgicas/clasificación , Polipropilenos/efectos adversos , Resultado del Tratamiento , Hernia Ventral/etiología , Mallas Quirúrgicas
16.
Acta cir. bras ; Acta cir. bras;25(5): 423-427, Sept.-Oct. 2010. tab
Artículo en Inglés | LILACS | ID: lil-558728

RESUMEN

PURPOSE: To compare two different incisional hernia repair techniques (repair with a polypropylene mesh reinforcement on the peritonium-aponeurosis versus polypropylene mesh sutured to the borders of the hernial ring as a bridge) in rabbits. METHODS: Incisional hernia was experimentally developed through a 4-cm median incision in 60 rabbits. After 30 days, half of the animals were operated for primary wall closure and placement of a polypropylene mesh reinforcement, while the other half had a polypropylene mesh sutured to the borders of the hernial ring as a bridge. Clinical development, scar breaking strength, as well as gross, microscopic and morphometric parameters were evaluated in all animals 30, 60, and 90 days after repair. RESULTS: No significant differences in breaking strength or histological parameters were observed between groups at any time point studied. No statistical difference regarding complications was detected, although denser and firmer adhesions to the abdominal wall were seen after the mesh was placed as a " bridge" . CONCLUSIONS: No significant differences between the incisional hernia repair techniques assessed were observed regarding breaking strength, and histological and morphometric parameters. The number of complications was similar in both study groups. However, adhesion of abdominal cavity organs to the scar area was much denser after the placement of a mesh to bridge the defect.


OBJETIVO: Comparar duas técnicas de tratamento da hérnia incisional em coelhos utilizando a tela de polipropileno apoiando um reforço peritônio - aponeurótico ou suturada nas bordas do anel herniário 'em ponte" . MÉTODOS: Foram operados 60 coelhos para a produção de hérnia incisional, em uma incisão mediana de 4 centímetros. Após 30 dias, metade dos animais foram operados com o fechamento primário da parede, com colocação de uma tela de polipropileno apoiando o reforço e a outra metade dos animais com a colocação da tela suturada nas bordas do anel herniário " em ponte" . Os animais foram avaliados com 30 (M1), 60 (M2)e 90 (M3) dias de pós-operatório. Os parâmetros analisados foram a evolução clínica, análise da força de ruptura da cicatriz, estudo macroscópico, análise microscópica e morfométrica. RESULTADOS: Não foram observadas diferenças significantes com relação a força de ruptura e estudos histológicos nos dois grupos e vários momentos estudados. Não houve diferença estatística com relação às complicações, embora os animais que receberam a tela " em ponte" tiveram aderências mais firmes e intensas à parede abdominal. CONCLUSÕES: As duas técnicas utilizadas para correção da hérnia incisional em coelhos não mostraram diferenças significantes quanto a força de ruptura, análise histológica e morfométrica. O número de complicações foi semelhante, porém a aderência de órgãos da cavidade abdominal à área de cicatriz foi muito mais intensa no grupo em que a tela foi colocada " em ponte" .


Asunto(s)
Animales , Masculino , Conejos , Hernia Abdominal/cirugía , Polipropilenos , Mallas Quirúrgicas , Modelos Animales de Enfermedad , Mallas Quirúrgicas/efectos adversos , Adherencias Tisulares/patología , Cicatrización de Heridas/fisiología
17.
Acta cir. bras. ; 25(4): 342-346, July-Aug. 2010. ilus, graf, tab
Artículo en Inglés | VETINDEX | ID: vti-7655

RESUMEN

PURPOSE: To evaluate whether the lining facing the visceral side of polypropylene mesh made with 2-hydroxyethyl methacrylate (p(HEMA)) hydrogel could avoid peritoneal adhesion in female dogs. METHODS: Eight animals (group PP) had a polypropylene mesh implanted to correct a defect in the rectal abdominal muscle, whereas in the other group (group PH) the polypropylene mesh was coated with p(HEMA) composite on the surface facing the peritoneal area. RESULTS: Adhesions were observed on the mesh in 62.5 percent of the PP group. In the PH group adhesions were present only on the suture lines. CONCLUSION: p(HEMA) hydrogel was well tolerated and effective in avoiding visceral and omental adhesions on the surface of the polypropylene mesh.(AU)


OBJETIVO: Avaliar se o revestimento da face visceral de uma tela de polipropileno com 2-hidroxietil dimetacrilato (p(HEMA)) poderia evitar aderências peritoniais em cadelas. MÉTODOS: Em oito animais (Grupo PP) foram implantadas telas de polipropileno para correção de um defeito do músculo reto abdominal, enquanto em outro grupo (Grupo PH) fez-se a implantação de uma tela de polipropileno cuja face peritonial foi revestida por 2-hidroxietil dimetacrilato (p(HEMA)). RESULTADOS: Foram observados 62,5 por cento de aderências peritoniais sobre a tela nos animais do Grupo PP, enquanto que no Grupo PH estas não ocorreram, exceto sobre a linha se sutura. CONCLUSÃO: O hidrogel de p(HEMA) foi bem tolerado pelos animais e mostrou-se efetivo na prevenção das aderências viscerais e omentais sobre a tela de polipropileno.(AU)


Asunto(s)
Animales , Femenino , Perros , Hernia Abdominal/cirugía , Materiales Biocompatibles/uso terapéutico , Mallas Quirúrgicas , Polipropilenos
18.
Acta cir. bras. ; 25(4): 337-341, July-Aug. 2010. ilus
Artículo en Inglés | VETINDEX | ID: vti-7654

RESUMEN

PURPOSE: To verify if the composit poli (2-hydroxyethyl methacrylate)-PolyHEMA/polypropylene mesh implanted in the female rat's abdominal wall could be suitable for the prevention of peritoneal adhesions, and for the evaluation of the tecidual response produced by this biomaterial. METHODS: Polypropylene meshes (Group PP, n=20) and polypropylene meshes coated with a layer of poli (2-hydroxyethyl methacrylate)-PolyHEMA (Group PH, n=20) were implanted on the abdominal wall of Wistar female rats. Ten animals from each group were submitted to euthanasia at 15 and 30 days of the postoperative period. RESULTS: The animals from the group PP presented visceral adhesions on the mesh surface, which was not observed in the ones from group PH. At the histopathological examination foreign body response was observed in both groups, whilst there was a greater intensity of inflammatory response in group PH on both moments. CONCLUSION: The poli (2-hydroxyethyl methacrylate) polyHEMA hydrogel associated to polypropylene mesh reduces visceral adhesion formation in rats, although it may be associated to greater inflammatory reaction.(AU)


OBJETIVO: Verificar se compósito poli 2-hidroxietil dimetacrilato (PoliHEMA) / tela de polipropileno implantado na parede abdominal de ratas seria adequado para prevenção de aderências peritoneais e avaliar a resposta tecidual desencadeada por este biomaterial. MÉTODOS: Foram implantadas telas de polipropileno - Grupo PP (n=20) e telas de polipropileno revestidas por uma camada de poli 2 (hidroxietil dimetacrilato)-PolyHEMA - Grupo PH (n=20) na parede abdominal de ratas da linhagem Wistar. Dez animais de cada grupo foram submetidos à eutanásia aos 15 e 30 dias de pós-operatório. RESULTADOS: Os animais do grupo PP apresentaram aderências viscerais na superfície da tela, o que não foi observado nos do grupo PH. Observou-se no exame histopatológico resposta tipo corpo estranho nos dois grupos sendo que no grupo PH houve maior intensidade de resposta inflamatória nos dois momentos. CONCLUSÃO: O hidrogel de poliHEMA quando associado à tela de polipropileno reduz a formação de aderências viscerais em ratos, embora possa estar associado à reação inflamatória mais intensa.(AU)


Asunto(s)
Animales , Femenino , Ratas , Hernia Abdominal/cirugía , Materiales Biocompatibles/uso terapéutico , Mallas Quirúrgicas , Polipropilenos
19.
Acta cir. bras ; Acta cir. bras;25(4): 337-341, July-Aug. 2010. ilus
Artículo en Inglés | LILACS | ID: lil-553240

RESUMEN

PURPOSE: To verify if the composit poli (2-hydroxyethyl methacrylate)-PolyHEMA/polypropylene mesh implanted in the female rat's abdominal wall could be suitable for the prevention of peritoneal adhesions, and for the evaluation of the tecidual response produced by this biomaterial. METHODS: Polypropylene meshes (Group PP, n=20) and polypropylene meshes coated with a layer of poli (2-hydroxyethyl methacrylate)-PolyHEMA (Group PH, n=20) were implanted on the abdominal wall of Wistar female rats. Ten animals from each group were submitted to euthanasia at 15 and 30 days of the postoperative period. RESULTS: The animals from the group PP presented visceral adhesions on the mesh surface, which was not observed in the ones from group PH. At the histopathological examination foreign body response was observed in both groups, whilst there was a greater intensity of inflammatory response in group PH on both moments. CONCLUSION: The poli (2-hydroxyethyl methacrylate) polyHEMA hydrogel associated to polypropylene mesh reduces visceral adhesion formation in rats, although it may be associated to greater inflammatory reaction.


OBJETIVO: Verificar se compósito poli 2-hidroxietil dimetacrilato (PoliHEMA) / tela de polipropileno implantado na parede abdominal de ratas seria adequado para prevenção de aderências peritoneais e avaliar a resposta tecidual desencadeada por este biomaterial. MÉTODOS: Foram implantadas telas de polipropileno - Grupo PP (n=20) e telas de polipropileno revestidas por uma camada de poli 2 (hidroxietil dimetacrilato)-PolyHEMA - Grupo PH (n=20) na parede abdominal de ratas da linhagem Wistar. Dez animais de cada grupo foram submetidos à eutanásia aos 15 e 30 dias de pós-operatório. RESULTADOS: Os animais do grupo PP apresentaram aderências viscerais na superfície da tela, o que não foi observado nos do grupo PH. Observou-se no exame histopatológico resposta tipo corpo estranho nos dois grupos sendo que no grupo PH houve maior intensidade de resposta inflamatória nos dois momentos. CONCLUSÃO: O hidrogel de poliHEMA quando associado à tela de polipropileno reduz a formação de aderências viscerais em ratos, embora possa estar associado à reação inflamatória mais intensa.


Asunto(s)
Animales , Femenino , Ratas , Pared Abdominal/cirugía , Implantes Experimentales , Enfermedades Peritoneales/prevención & control , Peritoneo/efectos de los fármacos , Polipropilenos/efectos adversos , Mallas Quirúrgicas/efectos adversos , Pared Abdominal/patología , Materiales Biocompatibles , Reacción a Cuerpo Extraño/etiología , Reacción a Cuerpo Extraño/patología , Inflamación/patología , Enfermedades Peritoneales/etiología , Peritoneo/patología , Polihidroxietil Metacrilato/efectos adversos , Ratas Wistar , Técnicas de Sutura , Adherencias Tisulares/patología , Adherencias Tisulares/prevención & control
20.
Acta cir. bras ; Acta cir. bras;25(4): 342-346, July-Aug. 2010. ilus, graf, tab
Artículo en Inglés | LILACS | ID: lil-553241

RESUMEN

PURPOSE: To evaluate whether the lining facing the visceral side of polypropylene mesh made with 2-hydroxyethyl methacrylate (p(HEMA)) hydrogel could avoid peritoneal adhesion in female dogs. METHODS: Eight animals (group PP) had a polypropylene mesh implanted to correct a defect in the rectal abdominal muscle, whereas in the other group (group PH) the polypropylene mesh was coated with p(HEMA) composite on the surface facing the peritoneal area. RESULTS: Adhesions were observed on the mesh in 62.5 percent of the PP group. In the PH group adhesions were present only on the suture lines. CONCLUSION: p(HEMA) hydrogel was well tolerated and effective in avoiding visceral and omental adhesions on the surface of the polypropylene mesh.


OBJETIVO: Avaliar se o revestimento da face visceral de uma tela de polipropileno com 2-hidroxietil dimetacrilato (p(HEMA)) poderia evitar aderências peritoniais em cadelas. MÉTODOS: Em oito animais (Grupo PP) foram implantadas telas de polipropileno para correção de um defeito do músculo reto abdominal, enquanto em outro grupo (Grupo PH) fez-se a implantação de uma tela de polipropileno cuja face peritonial foi revestida por 2-hidroxietil dimetacrilato (p(HEMA)). RESULTADOS: Foram observados 62,5 por cento de aderências peritoniais sobre a tela nos animais do Grupo PP, enquanto que no Grupo PH estas não ocorreram, exceto sobre a linha se sutura. CONCLUSÃO: O hidrogel de p(HEMA) foi bem tolerado pelos animais e mostrou-se efetivo na prevenção das aderências viscerais e omentais sobre a tela de polipropileno.


Asunto(s)
Animales , Perros , Femenino , Músculos Abdominales/cirugía , Materiales Biocompatibles/uso terapéutico , Hidrogeles/uso terapéutico , Enfermedades Peritoneales/prevención & control , Complicaciones Posoperatorias/prevención & control , Mallas Quirúrgicas , Resinas Compuestas/química , Implantes Experimentales , Ensayo de Materiales , Adherencias Tisulares/prevención & control
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA