Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 5.497
Filtrar
1.
Arq. bras. oftalmol ; Arq. bras. oftalmol;88(2): e2023, 2025. tab, graf
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1574023

RESUMEN

ABSTRACT Purpose: To evaluate the predictive value of initial intraocular pressure difference of the detached and fellow eyes of patients with complex rhegmatogenous retinal detachment on postoperative persistent ocular hypotony. Methods: This retrospective observational study included 538 eyes of 538 unilateral complex rhegmatogenous retinal detachment patients with a proliferative vitreoretinopathy grade of C-1 or higher, treated with silicone oil endotamponade following pars plana vitrectomy. The patients were divided into Group A (patients having silicone oil removal without ocular hypotony; n=504) and Group B (patients with persistent ocular hypotony following silicone oil removal [n=8, 23.5%] and with retained silicone oil [n=26, 76.5%] due to the risk of persistent ocular hypotony; total n=34). Ocular hypotony was defined as an intraocular pressure of <6 mmHg on two or more occasions. Patients' demographics, including age, sex, and follow-up time, and ocular characteristics, including ocular surgical and trauma history, initial and final best-corrected visual acuity, intraocular pressure and initial intraocular pressure difference of the detached and fellow eyes, and anatomical success rates and postoperative complications, were retrospectively collected from the electronic patient files. Results: The initial intraocular pressure was significantly lower in the detached eyes of Group B than in Group A (8.3 ± 3.5 vs. 12.9 ± 3.3, p<0.001). Also, the initial intraocular pressure difference was significantly higher in Group B than in Group A (8.9 ± 3.2 vs. 2.2 ± 2.7mmHg, p<0.001). The receiver operating characteristic curve analysis showed that the cutoff value of the initial intraocular pressure difference was 7.5mmHg for the risk of persistent ocular hypotony. The most influential factors on postoperative persistent ocular hypotony in the binary logistic regression analysis were the initial intraocular pressure difference and the need for a retinectomy. Conclusion: In eyes with complex rhegmatogenous retinal detachment treated with pars plana vitrectomy and silicone oil tamponade, the initial intraocular pressure difference could be of value in predicting postoperative persistent ocular hypotony and could guide surgeons on the decision of silicone oil removal.

2.
Arq. bras. oftalmol ; Arq. bras. oftalmol;88(1): e2023, 2025. tab, graf
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1568843

RESUMEN

ABSTRACT Purpose: This study aimed to compare the safety and effectiveness of intraocular pressure reduction between micropulse transscleral cyclophotocoagulation and "slow cook" transscleral cyclophotocoagulation in patients with refractory primary open-angle glaucoma. Methods: We included patients with primary open angle glaucoma with at least 12 months of follow-up. We collected and analyzed data on the preoperative characteristics and postoperative outcomes. The primary outcomes were a reduction of ≥20% of the baseline value (criterion A) and/or intraocular pressure between 6 and 21 mmHg (criterion B). Results: We included 128 eyes with primary open-angle glaucoma. The preoperative mean intraocular pressure was 25.53 ± 6.40 and 35.02 ± 12.57 mmHg in the micropulse- and "slow cook" transscleral cyclophotocoagulation groups, respectively (p<0.001). The mean intraocular pressure was reduced significantly to 14.33 ± 3.40 and 15.37 ± 5.85 mmHg in the micropulse- and "slow cook" transscleral cyclophotocoagulation groups at the last follow-up, respectively (p=0.110). The mean intraocular pressure reduction at 12 months was 11.20 ± 11.46 and 19.65 ± 13.22 mmHg in the micropulse- and "slow cook" transscleral cyclophotocoagulation groups, respectively (p<0.001). The median preoperative logMAR visual acuity was 0.52 ± 0.69 and 1.75 ± 1.04 in the micropulse- and "slow cook" transscleral cyclophotocoagulation groups, respectively (p<0.001). The mean visual acuity variation was −0.10 ± 0.35 and −0.074 ± 0.16 in the micropulse- and "slow cook" transscleral cyclophotocoagulation, respectively (p=0.510). Preoperatively, the mean eye drops were 3.44 ± 1.38 and 2.89 ± 0.68 drugs in the micropulse- and "slow cook" transscleral cyclophotocoagulation groups, respectively (p=0.017), but those were 2.06 ± 1.42 and 1.02 ± 1.46 at the end of the study in the "slow cook" and micropulse transscleral cyclophotocoagulation groups, respectively (p<0.001). The success of criterion A was not significant between both groups. Compared with 11 eyes (17.74%) in the "slow cook" transscleral cyclophotocoagulation group, 19 eyes (28.78%) in the micropulse transscleral cyclophotocoagulation group showed complete success (p=0.171). For criterion B, 28 (42.42%) and 2 eyes (3.22%) showed complete success after micropulse- and "slow cook" transscleral cyclophotocoagulation, respectively (p<0.001). Conclusion: Both techniques reduced intraocular pressure effectively.

3.
Arq. bras. oftalmol ; Arq. bras. oftalmol;88(1): e2023, 2025. tab, graf
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1568846

RESUMEN

ABSTRACT Purpose: This study aimed to determine whether early-stage intraocular pressure can be modulated using a thermal face mask. Methods: In this prospective clinical study, healthy participants were randomized on a 1:1:1 allocation ratio to three mask groups: hypothermic (G1), normothermic (G2), and hyperthermic (G3). After randomization, 108 eyes from 108 participants were submitted to clinical evaluations, including measurement of initial intraocular pressure (T1). The thermal mask was then applied for 10 minutes, followed by a second evaluation of intraocular pressure (T2) and assessment of any side effects. Results: The hypothermic group (G1) showed a significant reduction in mean intraocular pressure between T1 (16.97 ± 2.59 mmHg) and T2 (14.97 ± 2.44 mmHg) (p<0.001). G2 showed no significant pressure difference between T1 (16.50 ± 2.55 mmHg) and T2 (17.00 ± 2.29 mmHg) (p=0.054). G3 showed a significant increase in pressure from T1 (16.53 ± 2.69 mmHg) to T2 (18.58 ± 2.95 mmHg) (p<0.001). At T1, there was no difference between the three study groups (p=0.823), but at T2, the mean values of G3 were significantly higher than those of G1 and G2 (p<0.00). Conclusion: Temperature was shown to significantly modify intraocular pressure. Thermal masks allow the application of temperature in a controlled, reproducible manner. Further studies are needed to assess the duration of these effects and whether they are reproducible in patients with pathologies that affect intraocular pressure.

4.
Arq. bras. oftalmol ; Arq. bras. oftalmol;88(1): e2022, 2025. tab, graf
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1568854

RESUMEN

ABSTRACT Purpose: This study investigated the relationship between blood pressure and intraocular pressure in treatmentnaive, non-glaucoma patients with different blood pressure statuses, focusing on the 24-h ocular volume and nocturnal blood pressure decline. Methods: Treatment-naive, non-glaucoma patients undergoing hypertension evaluation were enrolled as study participants. Simultaneous 24-h ambulatory blood pressure measurement and 24-h ocular volume recording with a contact lens sensor. We also compared ocular volume curve parameters between normotensive and hypertensive patients, as well as between those with and without nocturnal blood pressure decline. Results: A total of 21 patients, including 7 normotensive and 14 treatment-naive hypertensive individuals, were included in the study. of them, 11 were dippers and 10 were non-dippers. No significant difference in the 24-h ocular volume slope was observed between the hypertensive and normotensive patients (p=0.284). However, dippers had a significantly higher 24-h ocular volume slope (p=0.004) and nocturnal contact lens sensor output (p=0.041) than non-dippers. Conclusion: Nocturnal blood pressure decline, rather than the blood pressure level, is associated with the increased 24-h ocular volume slope and nocturnal ocular volume. Further studies are required to determine whether the acceleration of glaucoma progression in dippers is primarily due to low blood pressure, high intraocular pressure, or a combination of both.

5.
Neurocrit Care ; 2024 Oct 02.
Artículo en Inglés | MEDLINE | ID: mdl-39358503

RESUMEN

In the management of traumatic brain injury (TBI), intracranial pressure monitoring (ICPm) is crucial for the timely management of severe cases that show rapid neurological deterioration. External ventricular drains (EVDs) and intraparenchymal pressure monitors (IPMs) are the primary methods used in this setting; however, the debate over their comparative efficacy persists, primarily because of reliance on observational study data. This underscores the need for a meta-analysis to guide clinical decision-making. This study-level meta-analysis aims to assess and compare the efficacy and safety of EVDs versus IPMs in the management of TBI. A database search was conducted until February 13, 2024, to identify studies reporting clinical outcomes of patients with TBI who underwent ICPm with either EVD or IPM. Primary outcomes included mortality, ICPm duration, length of stay, and complications. From an initial pool of 537 articles, eight studies (six retrospective cohort studies and two prospective cohort studies), encompassing 7080 patients, met our inclusion criteria. Mortality rates showed no significant difference between groups (risk ratio 1.11 [95% confidence interval (CI) 0.86 to 1.42], p = 0.42). Patients monitored with IPM had shorter intensive care unit length of stay (mean difference 0.90 [95% CI 0.21 to 1.59], p = 0.01) and ICPm duration (mean difference 0.79 [95% CI 0.33 to 1.24], p = 0.0007), with a higher risk of requiring surgical decompression. Monitoring-related complications were similar across the two groups. Our findings suggest that EVD and IPM provide similar outcomes in terms of mortality. However, IPM may offer significant advantages in reducing the duration of ICPm and intensive care unit length of stay. EVD may be preferable for certain mid-term to long-term monitoring. The predominance of observational studies in the current literature highlights the need for further clinical trials to compare these interventions.

6.
J Mol Model ; 30(11): 368, 2024 Oct 04.
Artículo en Inglés | MEDLINE | ID: mdl-39365492

RESUMEN

CONTEXT: We perform density functional theory calculations to study the dependence of the structural and electronic properties of the amino acid sarcosine crystal structure on hydrostatic pressure application. The results are analyzed and compared with the available experimental data. Our findings indicate that the crystal structure and properties of sarcosine calculated using the Grimme dispersion-corrected PBE functional (PBE-D3) best agree with the available experimental results under hydrostatic pressure of up to 3.7 GPa. Critical structural rearrangements, such as unit cell compression, head-to-tail compression, and molecular rotations, are investigated and elucidated in the context of experimental findings. Band gap energy tuning and density of state shifts indicative of band dispersion are presented concerning the structural changes arising from the elevated pressure. The calculated properties indicate that sarcosine holds great promise for application in electronic devices that involve pressure-induced structural changes. METHODS: Three widely used generalized gradient approximation functionals-PBE, PBEsol, and revPBE-are employed with Grimme's D3 dispersion correction. The non-local van der Waals density functional vdW-DF is also evaluated. The calculations are performed using the projector-augmented wave method in the Quantum Espresso software suite. The geometry optimization results are visualized using VMD. The Multiwfn and NCIPlot programs are used for wavefunction and intermolecular interaction analyses.

7.
J Diet Suppl ; 21(6): 868-880, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39385595

RESUMEN

BACKGROUND: Citrulline malate (CM), especially when used in conjunction with physical exercise, has demonstrated potential as a non-pharmacological adjunct in the management of hypertension. Nevertheless, its impact on nocturnal blood pressure dipping remains unexplored. OBJECTIVE: Evaluate the impact of a single dose of CM on nocturnal blood pressure dipping after exercise in hypertensive individuals. METHODS: In a double-blind, placebo-controlled, parallel-group clinical trial, twenty hypertensive adults (55 ± 16 years) were randomly assigned to either a CM (6 g) or placebo (6 g of corn starch) group (PLA). Resting blood pressure was measured after a 20-min period of comfortable seating in a calm environment. Both groups underwent 40 min of treadmill running/walking at an intensity of 60-70% of their reserve heart rate, 120 min after ingesting the substances. Ambulatory blood pressure monitoring was employed to measure blood pressure over 24 h. RESULTS: No significant differences in systolic blood pressure values were observed between the CM and PLA groups at rest, during wakefulness, sleep, or over a 24-h period. However, CM exhibited a significant reduction in diastolic blood pressure in several metrics: delta 24 h (-14 mmHg vs -6 mmHg, p = 0.047), delta wakefulness (-12 mmHg vs -4 mmHg, p = 0.024), percent delta 24 h (-16% vs -6%, p = 0.024), and percent delta wakefulness (-14% vs -4%, p = 0.013). No significant differences were found between CM and PLA in terms of systolic and diastolic nocturnal absolute reductions (-13 mmHg vs -12 mmHg, p = 0.808, and -13 mmHg vs -8 mmHg, p = 0.273, respectively) or nocturnal percentage decrease (-9.9% vs -9.4%, p = 0.844, and -15.3% vs -11.7%, p = 0.399, respectively). CONCLUSIONS: The study found no significant changes in the post-exercise nocturnal blood pressure dip following a single dose of CM supplementation. However, a notable reduction in diastolic blood pressure was observed during the waking period and over the average 24-h monitoring period. CLINICAL TRIAL REGISTRY NUMBER AND WEBSITE: ClinicalTrials.gov platform (NCT03378596).


Asunto(s)
Monitoreo Ambulatorio de la Presión Arterial , Presión Sanguínea , Citrulina , Suplementos Dietéticos , Ejercicio Físico , Hipertensión , Malatos , Humanos , Persona de Mediana Edad , Citrulina/farmacología , Citrulina/administración & dosificación , Citrulina/análogos & derivados , Método Doble Ciego , Masculino , Femenino , Hipertensión/tratamiento farmacológico , Hipertensión/fisiopatología , Hipertensión/terapia , Presión Sanguínea/efectos de los fármacos , Anciano , Malatos/administración & dosificación , Adulto , Ritmo Circadiano , Frecuencia Cardíaca/efectos de los fármacos , Sueño/efectos de los fármacos
8.
Glob Chang Biol ; 30(10): e17534, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-39412116

RESUMEN

Recent decades have witnessed substantial changes in freshwater biodiversity worldwide. Although research has shown that freshwater biodiversity can be shaped by changes in habitat diversity and human-induced pressure, the potentials for interaction between these drivers and freshwater biodiversity at large spatial extents remain unclear. To address these issues, we employed a spatially extensive multitrophic fish and insect database from 3323 stream sites across the United States, to investigate the ability of habitat diversity to modulate the effect of human pressure on the richness and abundance of fish and insects. We found evidence that high levels of habitat diversity were associated with increased richness and abundance of fish and insects (including whole-assemblage and individual trophic guilds). We also show that the effects of human pressure on the richness and abundance of fish and insects tend to become positive at high levels of habitat diversity. Where habitat diversity is low, human pressure strongly reduces insect richness and abundance, whereas these reductions are attenuated at high levels of habitat diversity. Structural equation modeling revealed that human pressure reduced habitat diversity, indirectly negatively affecting the richness and abundance of fish and insects. These findings illustrate that, in addition to promoting greater fish and insect biodiversity, habitat diversity may mitigate the deleterious effects of human pressures on these two stream assemblages. Overall, our study suggests that maintaining high levels of habitat diversity is a useful way to protect freshwater biodiversity from ongoing increases in human pressure. However, if human pressures continue to increase, this will reduce habitat diversity, further threatening stream assemblages.


Asunto(s)
Biodiversidad , Ecosistema , Peces , Insectos , Ríos , Animales , Insectos/fisiología , Peces/fisiología , Estados Unidos , Humanos , Actividades Humanas
9.
Animals (Basel) ; 14(19)2024 Oct 05.
Artículo en Inglés | MEDLINE | ID: mdl-39409816

RESUMEN

Marek's disease is caused by Mardivirus gallidalpha2, commonly known as Marek's disease virus (MDV). This pathogen infects various bird species resulting in a range of clinical manifestations. The meq gene, which is crucial for oncogenesis, has been extensively studied, but molecular investigations of MDV in noncommercial South American birds are limited. This study detected MDV in backyard and ornamental birds from Brazil and Peru and characterized the meq gene. MDV was confirmed in all seven outbreaks examined. Three isoforms of meq (S-meq, meq, and L-meq) and two to seven proline repeat regions (PRRs) were detected among the sequenced strains. At the amino acid level, genetic profiles with low and high virulence potential were identified. Phylogenetic analysis grouped the sequences into three distinct clusters. Selection pressure analysis revealed 18 and 15 codons under positive and negative selection, respectively. The results demonstrate significant MDV diversity in the studied birds, with both high and low virulence potentials. This study highlights the importance of monitoring and characterizing circulating MDV in backyard and ornamental birds, as they can act as reservoirs for future epidemiological outbreaks.

10.
Artículo en Inglés | MEDLINE | ID: mdl-39382637

RESUMEN

PURPOSE: To investigate the risk factors related to decrease in vessel density (VD) observed in primary open-angle glaucoma (POAG), due to acute increase in intraocular pressure (IOP) by an ophthalmodynamometer (OPD). METHODS: This cross-sectional study involved 42 eyes of participants (22 Controls and 20 POAG patients) that underwent optical coherence tomography angiography (OCT-A) to assess VD in the peripapillary region in three examination sets: primary gaze position (1), 25-degree adduction (2) and 25-degree adduction with OPD compression (3). Individual relationships between IOP levels and changes in the superficial complex VD were evaluated after image processing and exclusion of large retinal vessels. Multivariable regression analysis was used to verify factors associated with differences in VD induced by IOP elevation. RESULTS: A significant increase in IOP was induced by OPD compression during adduction (mean ± SD, Control: + 13.8 ± 2.8; POAG: + 13.4 ± 2.1 mmHg). Only during IOP elevation (set 3), a significant VD decrease was observed both in POAG eyes (p = 0.008) and controls (p = 0.022). Baseline IOP (p = 0.022), maximum IOP (p = 0.003), and scleral rigidity (p = 0.029) were significantly associated with VD decreases in eyes with POAG. No changes were observed in VD during adduction gaze exclusively. CONCLUSION: Acute IOP elevation induced with OPD, but not adduction gaze, decreased peripapillary VD measured with OCT-A imaging. IOP levels and scleral rigidity significantly affected VD reduction in POAG patients. Thus, high scleral rigidity may decrease the ability of the globe to dampen the well-known effects of IOP fluctuation on glaucoma onset and progression. KEY MESSAGES: What is known Decrease vascular density in the peripapillary retina was associated with POAG, but factors related to the vascular response to elevated IOP are unexplored. What is new OCT-A quantification shows decreases in vascular density of the superficial layers of the peripapillary retina during an acute elevation in IOP. High IOP levels and scleral rigidity significantly affected vascular density reduction in POAG patients.

11.
Artículo en Inglés | MEDLINE | ID: mdl-39395908

RESUMEN

INTRODUCTION: Renal denervation has been associated with substantial and sustained blood pressure reduction and is considered to serve as an alternative treatment for patients with resistant hypertension. However, the first published SHAM-controlled trial assessing RDN safety and efficacy showed no difference between groups. AIM: We aimed to perform a meta-analysis quantifying the magnitude of blood pressure decrease secondary to renal denervation in patients with resistant hypertension. METHODS: Databases were searched for RCTs that compared RDN therapy to SHAM procedure and reported the outcomes of (1) 24-hour ambulatory blood pressure; (2) Office systolic blood pressure; (3) Daytime systolic blood pressure; and (4) Night-time systolic blood pressure. Mean differences with 95% confidence intervals (CIs) were calculated using a random-effects model. Heterogeneity was examined with I² statistics. P values of < 0.05 were considered statistically significant. Statistical analyses were performed using RStudio 4.2.3. RESULTS: Nine studies and 1622 patients were included. The AMBP [MD -3.72 95%CI -5.44, -2.00 p < 0.001; I²=34%] and DSBP [MD -4.10 95%CI -5.84, -2.37 p < 0.001; I²=0%] were significantly reduced in the RDN arm. ODBP [MD -6.04 95%CI -11.31, -0.78 p = 0.024; I²=90%] and NSBP [MD -1.81 95%CI -3.90, 0.27 p = 0.08; I²=0%] did not reach a statistically significant difference between groups. CONCLUSION: Renal denervation demonstrates greater efficacy in reducing 24-hour ambulatory and daytime systolic blood pressure in patients diagnosed with resistant hypertension.

13.
Endocrinol Diabetes Nutr (Engl Ed) ; 71(8): 340-347, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-39374996

RESUMEN

INTRODUCTION: Elevated plantar pressure (PP) constitutes a risk factor for developing foot ulcers. Once present, elevated PP increases morbidity and mortality in patients with diabetes. Given the high prevalence of overweight and obesity in the Mexican population, this study aimed to describe the magnitudes and the distribution of the PP observed in a sample of newly diagnosed patients with diabetes, adjusting for body mass index (BMI) groups (normal weight, overweight, grade I obesity, and grade II and III obesity). MATERIALS AND METHODS: A total of 250 volunteers attending a comprehensive care program for the management of type 2 diabetes received foot assessments that included vascular and neurological evaluation, the identification of musculoskeletal changes, and measurements of PP. RESULTS: Diabetic neuropathy and peripheral arterial disease were present in 21.6% and 11.2% of all participants. Musculoskeletal alterations were present in 70.8% of participants. A positive and significant correlation (p<0.001) was observed between BMI and the peak PP of all anatomical regions assessed. After adjusting for BMI, significant differences (p<0.001) were seen between groups. The metatarsal region, particularly under the third metatarsal head, denoted the highest magnitudes across all BMI. CONCLUSIONS: Periodic PP assessment is recommended to identify the distribution of high-pressure points along the plantar surface. However, as a preventive measure, it is suggested to encourage patients with diabetes and overweight or obesity to wear appropriate footwear and pressure-relief insoles to relieve high-pressure areas - often seen in these populations - to help prevent foot complications.


Asunto(s)
Diabetes Mellitus Tipo 2 , Pie Diabético , Sobrepeso , Presión , Humanos , México/epidemiología , Masculino , Femenino , Sobrepeso/complicaciones , Persona de Mediana Edad , Diabetes Mellitus Tipo 2/complicaciones , Pie Diabético/prevención & control , Pie Diabético/epidemiología , Adulto , Pie , Índice de Masa Corporal , Estudios Transversales , Obesidad/complicaciones , Neuropatías Diabéticas/prevención & control , Neuropatías Diabéticas/epidemiología , Anciano
14.
Hypertens Res ; 2024 Oct 08.
Artículo en Inglés | MEDLINE | ID: mdl-39379464

RESUMEN

The association between diabetes mellitus (DM) and masked hypertension (MH) in ambulatory blood pressure (BP) monitoring is established, but its relationship with home BP monitoring (HBPM) remains uncertain. This web-based database study compared BP phenotypes in individuals using (n = 51,194; 6.05% with DM) and not using (n = 55,320; 0.63% with DM) antihypertensive medications (AH) undergoing HBPM. Multivariable logistic regression analysis revealed similar MH and white-coat hypertension (WCH) prevalence in individuals with or without DM, irrespective of AH use. However, among AH non-users, DM was associated with a higher likelihood of normotension (OR 1.35, 95%CI 1.09-1.66; p = 0.006) and a lower likelihood of sustained hypertension (OR 0.77, 95%CI 0.60-0.99; p = 0.039) compared to individuals without DM. These findings suggest that while DM does not significantly impact MH and WCH in HBPM, it may influence normotension and sustained hypertension rates in AH non-users. Likelihood of diabetes mellitus according to blood pressure phenotypes. AH - antihypertensive medications; CH - controlled hypertension; MH - masked hypertension; MUCH - masked uncontrolled hypertension; NT - normotension; SH - sustained hypertension; SUCH - sustained uncontrolled hypertension; WCH - white-coat hypertension; WUCH - white-coat uncontrolled hypertension.

15.
Braz J Anesthesiol ; 74(6): 844563, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39383993

RESUMEN

BACKGROUND: Superior Vena Cava (SVC) diameter and collapsibility index, dynamic measures of fluid responsiveness, have been successfully utilized as echocardiographic indices for fluid responsiveness in ventilated septic patients. Whether these measurements are correlated with Central Venous Pressure (CVP) measurements in liver transplant patients is unknown. We sought to assess the correlation of maximum and minimum SVC diameter and SVC collapsibility index measurements obtained intraoperatively by Transesophageal Echocardiography (TEE) with those of simultaneously recorded CVP measurements obtained through a right atrial port of a pulmonary artery catheter. The secondary aim of the study was to assess the correlation between SVC measurements and simultaneously obtained thermodilution cardiac index measurements. METHODS: Single center prospective observational trial of patients with end stage liver disease undergoing liver transplantation in an academic tertiary care center. RESULTS: The minimum SVC exhibited a mild significant correlation with CVP as did the maximum SVC. The correlation between the SVC collapsibility index and CVP was not significantly different from zero. In our secondary analysis, the correlation between minimum SVC diameter and cardiac index was determined to be weak but non-zero as was the correlation between the maximum SVC diameter and cardiac index. The correlation between SVC collapsibility index and cardiac index was not different from zero. CONCLUSION: While statistically significant, the weak clinical correlation of intraoperative SVC measurements obtained by TEE make them unsuitable as a replacement for central venous pressure or thermodilution cardiac index measurements in liver transplant recipients.


Asunto(s)
Presión Venosa Central , Ecocardiografía Transesofágica , Trasplante de Hígado , Vena Cava Superior , Humanos , Estudios Prospectivos , Trasplante de Hígado/métodos , Masculino , Femenino , Persona de Mediana Edad , Vena Cava Superior/diagnóstico por imagen , Presión Venosa Central/fisiología , Ecocardiografía Transesofágica/métodos , Termodilución/métodos , Adulto , Anciano , Enfermedad Hepática en Estado Terminal/cirugía , Enfermedad Hepática en Estado Terminal/fisiopatología , Cateterismo de Swan-Ganz
16.
Artículo en Inglés | MEDLINE | ID: mdl-39381335

RESUMEN

Effective patient positioning is a critical factor influencing surgical outcomes, mainly in minimally invasive gynecologic surgery (MIGS) where precise positioning facilitates optimal access to the surgical field. This paper provides a comprehensive exploration of the significance of strategic patient placement in MIGS, emphasizing its role in preventing intraoperative injuries and enhancing overall surgical success. The manuscript addresses potential complications arising from suboptimal positioning and highlights the essential key points for appropriate patient positioning during MIGS, encompassing what the surgical team should or shouldn't do. In this perspective, the risk factors associated with nerve injuries, sliding, compartment syndrome, and pressure ulcers are outlined to guide clinical practice. Overall, this paper underscores the critical role of precise patient positioning in achieving successful MIGS procedures and highlights key principles for the gynecological team to ensure optimal patient outcomes.


Asunto(s)
Procedimientos Quirúrgicos Ginecológicos , Procedimientos Quirúrgicos Mínimamente Invasivos , Posicionamiento del Paciente , Humanos , Procedimientos Quirúrgicos Ginecológicos/métodos , Femenino , Posicionamiento del Paciente/métodos , Procedimientos Quirúrgicos Mínimamente Invasivos/métodos , Complicaciones Intraoperatorias/prevención & control , Complicaciones Posoperatorias/prevención & control
17.
Rev. Nac. (Itauguá) ; 16(3): 85-95, sep-dec 2024.
Artículo en Español | LILACS-Express | LILACS | ID: biblio-1572549

RESUMEN

RESUMEN Introducción: la úlcera por presión es aquella lesión que se localiza a nivel de la piel y tejidos más profundos. El comienzo de la aparición de ulceras por presión puede constituir un problema importante en la salud de los pacientes, causar molestias físicas, aumentar el tiempo de hospitalización y los costos de tratamiento. Objetivos: describir la prevalencia de pacientes internados que presentan úlceras por presión en el servicio de clínica médica del bloque modular del Hospital Nacional, 2022 a 2023. Metodología: estudio de diseño observacional, descriptivo, de corte transversal, que incluyó a 223 pacientes adultos internados en el Servicio de Clínica Médica del Hospital Nacional (Itauguá, Paraguay) durante el periodo de 2022 a 2023. Resultados: la prevalencia encontrada fue de 9,4 %. La edad media fue de 64 años, con predominio del sexo masculino (58 %). La localización más frecuente de las ulceras fue a nivel sacro (64 %), fueron múltiples el 14 %. Se encontró como patología determinante para el desarrollo de ulceras por presión el accidente cerebrovascular (41 %). Las ulceras por presión grado 1 y 2 fueron las más frecuentes (41 %, ambos). Conclusión: las ulceras por presión son una patología frecuente en pacientes internados. Existen comorbilidades asociadas, siendo el accidente cerebrovascular una de las más frecuentes.


ABSTRACT Introduction: a pressure ulcer is an injury that is located at the level of the skin and deeper tissues. The beginning of the appearance of pressure ulcers can constitute a major problem in the health of patients, causing physical discomfort, increasing hospitalization time and treatment costs. Objectives: describe the prevalence of hospitalized patients with pressure ulcers in the medical clinic service of the modular block of the National Hospital, 2022 - 2023. Methodology: observational, descriptive, prospective design study, which included 223 adult patients admitted to the medical clinic service of the Hospital Nacional (Itauguá, Paraguay) during the period from 2022 to 2023. Results: the prevalence found was 9.4 %. The average age was 64 years, with a predominance of males (58 %). The most frequent location of the ulcers was at the sacral level (64 %), 14 % were multiple. Cerebrovascular accident was found as a determining pathology for the development of pressure ulcers (41 %). Pressure ulcers grade 1 and 2 were the most frequent (41 % both). Conclusion: pressure ulcers are a common pathology in hospitalized patients. There are associated comorbidities, stroke being one of the most frequent.

18.
Rev. argent. cardiol ; 92(4): 269-276, set. 2024. tab, graf
Artículo en Español | LILACS-Express | LILACS | ID: biblio-1575935

RESUMEN

RESUMEN Introducción: En el diagnóstico y seguimiento de la hipertensión arterial (HTA) la mayoría de las guías de práctica recomiendan el monitoreo ambulatorio de la presión arterial (MAPA). En este sentido, existe cada vez más evidencia que respalda la superioridad de la hipertensión arterial nocturna (HTAN) como predictor de eventos cardiovasculares. Se sabe poco sobre la relación con los eventos cardiovasculares según la gravedad de la HTAN. Además, no está claro a partir de qué valor de presión arterial nocturna comienza a aumentar el riesgo. Objetivos: Conocer si la presencia de HTAN y sus niveles de gravedad se asocian con resultados cardiovasculares adversos durante el seguimiento. Material y métodos: Estudio observacional. Realizamos un análisis de los datos obtenidos en un centro médico de alta complejidad de Buenos Aires, recopilados a partir de estudios de MAPA de 24 horas. Examinamos las características clínicas de los pacientes, los resultados de laboratorio, los estudios de imagen y sus resultados durante el período de seguimiento. Nuestro estudio incluyó personas de 18 años o más a las que se les había diagnosticado hipertensión. Definimos HTAN como aquellos casos con valores de presión arterial ≥ 120/70 mmHg durante el periodo nocturno. Resultados: Fueron incluidos 981 pacientes en el análisis final. De ellos, el 53 % eran hombres; la edad media era de 59,4 años. Presentaban HTAN 63,6 % (n=624). Clasificamos la HTAN en cuatro estratos de gravedad para comparar, según el valor de presión arterial sistólica nocturna: 83-119 mmHg, 120-139 mmHg, 140-159 mmHg y 160-220 mmHg. Se registraron eventos adversos cardiovasculares mayores en 8 (2,2 %), 17 (4,1 %), 8 (5,6 %) y 7 (11,3 %) sujetos, respectivamente, y esta diferencia entre grupos fue estadísticamente significativa (p=0,007). El análisis multivariado de regresión de Cox demostró que la presencia de HTAN fue un predictor independiente de eventos cardiovasculares adversos (HR 3,60; IC 95% 1,12-11,5; p=0,033), incluso al considerar la presencia de hipertensión arterial diurna. Conclusión: En esta cohorte contemporánea, la HTAN y su gravedad se asociaron independientemente con la incidencia de eventos cardiovasculares adversos.


ABSTRACT Background: In the diagnosis and follow-up of arterial hypertension (HTN) most practice guidelines recommend ambulatory blood pressure monitoring (ABPM). In this regard, there is increasing evidence supporting the superiority of nocturnal hy pertension (NHTN) as a predictor of cardiovascular events. Little is known about the relationship with cardiovascular events according to the severity of NHTN. Furthermore, it is unclear from what nighttime pressure value the risk begins to increase. Objectives: The aim of this study was to determine whether the presence of NHTN and its severity levels are associated with adverse cardiovascular outcomes during follow-up. Methods: An observational study was performed analyzing data collected from 24-hour ABPM studies obtained in a high complexity medical center in Buenos Aires. We examined patients' clinical characteristics, laboratory findings, imaging studies and their results during the follow-up period. Our study included ≥18 year-old persons who had been diagnosed with hypertension. We defined NHTN as those cases with blood pressure values ≥120/70 mmHg during the nighttime period. Results: The final analysis included 981 patients. Among these, 53% were men, mean age was 59.4 years and NHTN was present in 63.6% of cases (n=624). Nocturnal HTN was classified into four severity strata for comparison, according to the nighttime systolic blood pressure value: 83-119 mmHg, 120-139 mmHg, 140-159 mmHg and 160-220 mmHg. Major adverse cardiovascular events were recorded in 8 (2.2%), 17 (4.1 %), 8 (5.6%) and 7 (11.3%) subjects, respectively, and this differ ence between groups was statistically significant (p=0.007). Multivariate Cox regression analysis showed that the presence of NHTN was an independent predictor of adverse cardiovascular events (HR 3.60; 95% CI 1.12-11.5; p=0.033), even when considering the presence of daytime hypertension. Conclusion: In this contemporary cohort, NHTN and its severity were independently associated with the incidence of adverse cardiovascular events.

19.
Neumol. pediátr. (En línea) ; 19(3): 103-109, sept. 2024. ilus
Artículo en Español | LILACS | ID: biblio-1572078

RESUMEN

La tomografía por impedancia eléctrica (TIE) es una modalidad de monitorización funcional respiratoria por imagen, no invasiva y libre de radiación, que permite visualizar en tiempo real la ventilación pulmonar regional y global en pacientes adultos y pediátricos conectados a Ventilación Mecánica (VM). OBJETIVO: Se describe la utilidad de la TIE en dos pacientes críticos pediátricos, en quienes no fue factible realizar medición de mecánica pulmonar, como herramienta para el ajuste de parámetros ventilatorios. CASOS CLÍNICOS: Se presentan dos pacientes pediátricos de 27 y 11 meses con condiciones clínicas diferentes, conectados a VM, en quienes se utilizó la TIE como método de monitoreo de la distribución pulmonar y titulación de la presión positiva al final de la espiración (PEEP) óptima, con el objetivo de obtener una ventilación pulmonar más homogénea. Se presentan mediciones funcionales con diferentes niveles de PEEP y valores de distribución en las distintas regiones de interés (ROI), además de un flujograma de situaciones en las que la TIE podría resultar útil para el ajuste ventilatorio. CONCLUSIÓN: La información funcional proporcionada por la TIE, permitió monitorizar de forma dinámica la VM y optimizar los parámetros ventilatorios, facilitando la implementación de estrategias de protección pulmonar en ambos pacientes, imposibilitados de realizar una medición estática de la mecánica respiratoria.


The Electrical Impedance Tomography (EIT) is a non-invasive and radiation-free respiratory functional imaging monitoring modality that allows real-time visualization of regional and global lung ventilation in adult and pediatric patients connected to mechanical ventilation (MV). OBJECTIVE: This paper describes the utility of EIT in two critical pediatric patients for whom measuring pulmonary mechanics was not feasible. EIT is used as a tool for adjusting ventilatory parameters. CLINICAL CASES: Two pediatric patients aged 27 and 11 months, with different clinical conditions, connected to MV are presented. EIT was used to monitor lung distribution and titrate the optimal Positive End-Expiratory Pressure (PEEP), to achieve more homogeneous lung ventilation. Functional measurements are presented with different PEEP levels and distribution values in different regions of interest (ROI), along with a flowchart illustrating situations where EIT could be useful for ventilatory adjustment. CONCLUSION: The functional information provided by EIT, allowed dynamic monitoring of MV, optimizing ventilatory parameters and facilitating the implementation of lung protective strategies in both patients, unable to undergo static respiratory mechanics measurements.


Asunto(s)
Humanos , Masculino , Lactante , Preescolar , Respiración Artificial/métodos , Pruebas de Función Respiratoria , Tomografía Computarizada por Rayos X/métodos , Impedancia Eléctrica , Respiración con Presión Positiva , Cuidados Críticos , Monitoreo Fisiológico
20.
Explor Res Clin Soc Pharm ; 16: 100502, 2024 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-39308553

RESUMEN

Objective: To validate the General Medication Adherence Scale (GMAS) in Brazilian Portuguese for hypertensive patients. Methods: The GMAS-English was translated into Brazilian Portuguese and adapted for cultural appropriateness by a translation process and expert panel. A cross-sectional study was conducted in northeast Brazilian cardiology divisions of public and private hospitals, interviewing hypertensive patients. Reliability was assessed using Cronbach's alpha, intraclass correlation, and Pearson's correlation. Convergent validity was tested against the BMQ using chi-square. Criterion validity was assessed by comparing GMAS with blood pressure control using chi-square. Results: The GMAS was translated and adapted according to standard procedures. In a validation study with 167 hypertensive patients, Cronbach's alpha was 0.79, and Pearson's correlation showed significant test-retest reliability (p < 0.001). Convergent validity with BMQ was significant (p < 0.001), with 89.4 % sensitivity for behaviors considered adherent (High adherence and good adherence), but between the strata that measure low adherence (Partial adherence, low adherence and very low adherence), the specificity rate was 50 %. Criterion validity between GMAS and blood pressure control was not observed. Conclusion: The Brazilian Portuguese version of the GMAS exhibited good consistency and reproducibility, modest agreement with BMQ scale and did not demonstrate acceptable criterion validity for hypertensive patients.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA