Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 54
Filtrar
1.
Acta Ortop Bras ; 32(3): e269705, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39119246

RESUMEN

Objective: Tibial plateau fractures are common intra-articular fractures that pose classification and treatment challenges for orthopedic surgeons. Objective: This study examines the value of 3D printing for classifying and planning surgery for complex tibial plateau fractures. Methods: We reviewed 54 complex tibial plateau fractures treated at our hospital from January 2017 to January 2019. Patients underwent preoperative spiral CT scans, with DICOM data processed using Mimics software. 3D printing technology created accurate 1:1 scale models of the fractures. These models helped subdivide the fractures into seven types based on the tibial plateau's geometric planes. Surgical approaches and simulated operations, including fracture reduction and plate placement, were planned using these models. Results: The 3D models accurately depicted the direction and extent of fracture displacement and plateau collapse. They facilitated the preoperative planning, allowing for precise reconstruction strategies and matching intraoperative details with the pre-printed models. Post-surgery, the anatomical structure of the tibial plateau was significantly improved in all 54 cases. Conclusion: 3D printing effectively aids in the classification and preoperative planning of complex tibial plateau fractures, enhancing surgical outcomes and anatomical restoration. Level of Evidence IV, Prospective Study.


Objetivo: As fraturas do planalto tibial são fraturas intra-articulares comuns de classificação e tratamento desafiadores aos cirurgiões ortopédicos. Objetivo: Este estudo investiga o uso de impressão 3D para classificar e planejar a cirurgia de fraturas complexas do planalto tibial. Métodos: 54 fraturas complexas do planalto tibial tratadas em nosso hospital de janeiro de 2017 a janeiro de 2019 foram revisadas. Os pacientes foram submetidos a tomografias computadorizadas em espiral pré-operatórias, com dados DICOM processados usando o software Mimics. A tecnologia de impressão 3D gerou modelos precisos em escala 1:1 das fraturas. Estes modelos ajudaram a subdividir as fraturas em sete tipos com base nos planos geométricos do planalto tibial. As abordagens cirúrgicas e as operações simuladas, incluindo a redução da fratura e a colocação de placa, foram planejadas utilizando estes modelos. Resultados: Os modelos 3D representaram com precisão a direção e a extensão da deslocação da fratura e do colapso do planalto. Os modelos facilitaram o planejamento pré-operatório, viabilizando estratégias de reconstrução precisas e a correspondência dos detalhes intraoperatórios com os modelos pré-impressos. Após a cirurgia, a estrutura anatômica do planalto tibial melhorou significativamente em todos os 54 casos. Conclusão: A impressão 3D ajuda na classificação e no planejamento pré-operatório de fraturas complexas do planalto tibial, melhorando os resultados cirúrgicos e a restauração anatômica. Nível de Evidência IV, Estudo Prospectivo.

2.
J Clin Orthop Trauma ; 54: 102491, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-39101045

RESUMEN

Background: Restoring joint congruence and maintaining reduction until healing is imperative in treating tibial plateau fractures (TPF). The main objective of this study was to evaluate the feasibility of augmentation with impacted bone allograft (IBA) to prevent loss of reduction in tibial plateau fractures during healing and to evaluate its incorporation. Methods: We retrospectively analyzed all patients with an acute, closed tibial plateau fracture (Schatzker II, III, IV) treated between 2010 and 2019 with open reduction and internal fixation (ORIF) and impacted bone allograft (IBA), with a minimum follow-up of 24 months. We evaluated the postoperative radiographs by drawing a line along the tibial axis and another perpendicular to the healthy plateau to measure the reduction and subsequent behavior. The incorporation of the allograft was evaluated by radiological analysis assessing its integration, non-union, resorption, or sclerosis. We used the clinical-radiological Rasmussen system and the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) to objectify the outcomes. Results: 78 TPFs were included, with a median age of 51.5 (40.7-62.2) years and a median follow-up of 66 (24-89) months. Two (2.5 %) patients presented loss of joint reduction (subsidence) during the follow-up regarding the achieved in the surgery. Seventy-six (94.7 %) patients presented integration, two (2.5 %) resorption, and one (1.3 %) sclerosis. Seventy-two (92.3 %) patients presented excellent and good results in the Rasmussen radiological score, and 72 (92.3 %) patients presented excellent or good clinical scores. The mean WOMAC at two years postoperatively was 15 ± 6.5. Conclusion: Our results demonstrate that allograft is an adjuvant in maintaining a reduction in type II, III, and IV Schatzker's tibial plateau fractures. Low rates of loss of reduction during follow-up can be expected with its use.

3.
Rev Bras Ortop (Sao Paulo) ; 59(2): e206-e212, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38606135

RESUMEN

Objective To compare the functional outcomes of two circular external fixation techniques to treat complex fractures of the proximal end of the tibia. Materials and Methods The present is a retrospective cohort study with 51 patients who underwent surgical treatment for complex fractures of the tibial plateau with a circular external fixator. There were two groups of patients: 12 subjects underwent treatment with the classic assembly technique, and 39 subjects underwent treatment with the simplified technique. The variables analyzed included age, sex, injury mechanism, trauma energy, associated injuries, fixator type, time of fixator use, and clinical-radiographic outcomes. The classic technique mainly uses transfixing Kirschner wires, while the simplified one replaces the Kirschner wires with Schanz pins in the distal block of the circular external fixator. Result There were no statistically significant differences ( p > 0.05) between the two groups concerning the clinical-radiographic outcomes, including fracture consolidation, quality of joint fracture reduction, range of motion, lower limbs residual discrepancy, and postoperative pain. Conclusion We suggest that the simplified technique, using Schanz pins instead of Kirschner wires, can be a viable and effective alternative to treat complex fractures of the proximal end of the tibia with a circular external fixator. This simplified approach can offer benefits, such as a lower infection rate and greater patient comfort, without compromising clinical and radiographic outcomes, thus justifying its use.

4.
Rev.Chil Ortop Traumatol ; 65(1): 9-15, abr.2024. ilus
Artículo en Español | LILACS | ID: biblio-1554939

RESUMEN

INTRODUCCION En los últimos años, se ha descrito el uso de placas horizontales para la fijación de fracturas que comprometen el reborde articular de los platillos tibiales, lo que se conoce como placa rim. La mayoría de las publicaciones al respecto describen su uso en columnas posteriores y posterolaterales de los platillos tibiales, y a la fecha hay escasos reportes del uso de este tipo de placa en la columna anteromedial y ninguno para la posteromedial. El objetivo de este artículo es presentar dos casos clínicos de fracturas conminutas del platillo tibial medial mostrando su tratamiento con el uso de placas rim. CASOS CLINICOS El primer caso presentaba compromiso anteromedial y posteromedial, y el segundo, compromiso posteromedial. En ambos casos, se logró la reducción mediante un abordaje posteromedial y su fijación con placa bloqueada de 2,7 mm como placa rim. En cada caso, se detalló la estrategia de reducción y el manejo postoperatorio. RESULTADOS Ambos pacientes consiguieron la consolidación ósea entre las semanas 14 y 18 tras la osteosíntesis definitiva, sin presentar pérdidas de reducción. Ambos lograron rango de movilidad articular completo (0°­125°), y retornaron a sus trabajos a los 4 y 6 meses respectivamente. CONCLUSIONES Estas placas ofrecen una buena opción de tratamiento para fracturas articulares conminutas del borde del platillo tibial, tanto en la columna anteromedial como en la posteromedial. A pesar de la ausencia de grandes series de pacientes con uso de placas rim mediales, el resultado de los casos presentados aquí nos permite plantear su utilidad al momento de enfrentarnos a fracturas del reborde articular


INTRODUCTION In recent years, the use of horizontal plates has been described to achieve fixation of fractures that compromise the articular ridge of the tibial plateau; these plates are known as "rim plates." Most publications report their use in the posterior and posterolateral columns of the tibial plateau, and to date there are few reports of its use for the fixation of the anteromedial column and none for the posteromedial column. The objective of the present article is to report two clinical cases of comminuted fractures of the medial tibial plateau, showing their treatment with the use of medial rim plates. CLINICAL CASES The first case presented with an anteromedial and posteromedial tibial plateau fracture, and the second, a posteromedial fracture. In both cases, reduction was achieved through a posteromedial approach, and the fixation was performed with a 2.7-mm locked rim plate. The reduction strategy and postoperative management were detailed in each case. RESULTS Both patients achieved bone consolidation during the 14th and 18th weeks after the definitive osteosynthesis, without presenting loss of reduction. Both patients achieved full range of joint motion (0°­125°) and returned to work after four and six months respectively. CONCLUSION These plates offer a good treatment option for comminuted fractures of the rim of the tibial plateau, for both the anteromedial and posteromedial columns. Despite the absence of large series of patients with the use of medial rim plates, the results of the two cases herein presented enables us to propose it as a useful tool when dealing with fractures of the medial rim of the tibial plateau


INTRODUCTION In recent years, the use of horizontal plates has been described to achieve fixation of fractures that compromise the articular ridge of the tibial plateau; these plates are known as "rim plates." Most publications report their use in the posterior and posterolateral columns of the tibial plateau, and to date there are few reports of its use for the fixation of the anteromedial column and none for the posteromedial column. The objective of the present article is to report two clinical cases of comminuted fractures of the medial tibial plateau, showing their treatment with the use of medial rim plates. CLINICAL CASES The first case presented with an anteromedial and posteromedial tibial plateau fracture, and the second, a posteromedial fracture. In both cases, reduction was achieved through a posteromedial approach, and the fixation was performed with a 2.7-mm locked rim plate. The reduction strategy and postoperative management were detailed in each case. RESULTS Both patients achieved bone consolidation during the 14th and 18th weeks after the definitive osteosynthesis, without presenting loss of reduction. Both patients achieved full range of joint motion (0°­125°) and returned to work after four and six months respectively. CONCLUSION These plates offer a good treatment option for comminuted fractures of the rim of the tibial plateau, for both the anteromedial and posteromedial columns. Despite the absence of large series of patients with the use of medial rim plates, the results of the two cases herein presented enables us to propose it as a useful tool when dealing with fractures of the medial rim of the tibial plateau


Asunto(s)
Humanos , Masculino , Persona de Mediana Edad , Fracturas de la Tibia/cirugía , Fracturas de la Tibia/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Fracturas Conminutas/cirugía , Fracturas Conminutas/diagnóstico por imagen , Fijación Interna de Fracturas/métodos , Cuidados Posteriores
5.
Eur J Orthop Surg Traumatol ; 34(4): 1831-1838, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38427052

RESUMEN

INTRODUCTION: The reported incidence of infection related with tibial plateau fractures (IRTPF) ranges from 2 to 23%. This complication can result in catastrophic consequences such as deformity, post-traumatic osteoarthritis, chronic pain, loss of function, and substantial economic burdens on healthcare systems due to extended hospital stays and the resources required for treatment. Consequently, it is imperative to emphasize the identification of infection risk factors. METHODS: A retrospective case-control study was designed, encompassing patients who underwent surgery for tibial plateau fractures between 2015 and 2020. Frequencies and measures of central tendency were compared between infected patients (cases) and non-infected patients (controls) using rank-based statistical tests. Subsequently, two logistic regression models were employed to control for potential confounding variables. RESULTS: A total of 314 patients were included, predominantly male (71.15%). Average age of 44.41 years. IRTPF were observed in 7.64% of the patients. In the univariate inferential statistical analysis, high-energy fractures (OR 6.35, p < 0.001), fractures with compartment syndrome (OR 7.10, p < 0.001), two-stage management with temporary external fixation (OR 8.18, p < 0.001), the use of 2 or more approaches in definitive surgery (OR 2.93, p = 0.011), and the use of two or more plates (OR 9.17, p < 0.001) were identified as risk factors for infection. On average, the duration of surgery in infected patients was 201.2 min, compared to 148.4 min in non-infected patients (p < 0.001). When performing two logistic regression models, the following independent risk factors were identified: high-energy fractures (OR 5.04, p = 0.012), the presence of compartment syndrome (OR 4.53, p = 0.007), and the use of two or more plates in definitive surgery (OR 5.04, p = 0.023). CONCLUSIONS: High-energy tibial plateau fractures (Schatzker IV, V, and VI), the presence of concomitant compartment syndrome, and the use of 2 or more plates in definitive surgery are associated with a higher risk of infection related to fracture following open reduction and osteosynthesis treatment. LEVEL OF EVIDENCE: Case-Control Study.


Asunto(s)
Fijación Interna de Fracturas , Infección de la Herida Quirúrgica , Fracturas de la Meseta Tibial , Adulto , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios de Casos y Controles , Síndromes Compartimentales/etiología , Fijación Interna de Fracturas/efectos adversos , Estudios Retrospectivos , Factores de Riesgo , Infección de la Herida Quirúrgica/etiología , Infección de la Herida Quirúrgica/epidemiología , Fracturas de la Meseta Tibial/complicaciones , Fracturas de la Meseta Tibial/cirugía
6.
Skeletal Radiol ; 53(6): 1091-1101, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38051424

RESUMEN

OBJECTIVES: Posterior tibial slope (PTS) is an important anatomic parameter of the knee related to anteroposterior instability. Biplanar stereoradiography allows for simultaneous low-dose acquisition of anteroposterior and lateral views with 3D capability, enabling separate lateral and medial plateau analyses. We aimed to evaluate the possibility and compare the reproducibility of measuring medial and lateral PTS on EOS® images with two different patient positionings and compare it with CT of the knees as the gold standard. METHODS: This is a retrospective study including volunteers who underwent lower limb stereoradiography and knee CT from 01/08/2016 to 07/31/2019. Sixty legs from 30 patients were studied. PTS were measured using stereoradiography and CT by two radiologists. Intraclass correlation was used to calculate intrarater and interrater reproducibilities. Pearson's correlation coefficients were used to calculate the correlation between stereoradiography and CT. We also compared the reproducibility of the stereoradiography of volunteers with 2 different positionings. RESULTS: The mean stereoradiography PTS values for right and left knees were as follows: lateral, 12.2° (SD: 4.1) and 10.1° (SD: 3.5); medial,12.2° (SD: 4.4) and 11.6° (SD: 3.9). CT PTS mean values for right and left knee are as follows: lateral, 10.3° (SD:2.5) and 10.6° (SD: 2.8); medial: 8.7° (SD: 3.7) and 10.4° (SD: 3.5). Agreement between CT and EOS for angles between lateral and medial PTS was good (right, 0.874; left, 0.871). Regarding patient positioning on stereoradiography, interrater and intrarater reproducibilities were greater for patients with nonparallel feet (0.738-0.883 and 0.870-0.975). CONCLUSIONS: Stereoradiography allows for appropriate delineation of tibial plateaus, especially in patients with nonparallel feet, for the purpose of measuring PTS. The main advantage is lower radiation doses compared to radiography and CT.


Asunto(s)
Articulación de la Rodilla , Tibia , Humanos , Estudios Retrospectivos , Reproducibilidad de los Resultados , Radiografía , Articulación de la Rodilla/diagnóstico por imagen , Tibia/diagnóstico por imagen
7.
Acta ortop. bras ; Acta ortop. bras;32(3): e269705, 2024. tab, graf
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1568749

RESUMEN

ABSTRACT Objective: Tibial plateau fractures are common intra-articular fractures that pose classification and treatment challenges for orthopedic surgeons. Objective: This study examines the value of 3D printing for classifying and planning surgery for complex tibial plateau fractures. Methods: We reviewed 54 complex tibial plateau fractures treated at our hospital from January 2017 to January 2019. Patients underwent preoperative spiral CT scans, with DICOM data processed using Mimics software. 3D printing technology created accurate 1:1 scale models of the fractures. These models helped subdivide the fractures into seven types based on the tibial plateau's geometric planes. Surgical approaches and simulated operations, including fracture reduction and plate placement, were planned using these models. Results: The 3D models accurately depicted the direction and extent of fracture displacement and plateau collapse. They facilitated the preoperative planning, allowing for precise reconstruction strategies and matching intraoperative details with the pre-printed models. Post-surgery, the anatomical structure of the tibial plateau was significantly improved in all 54 cases. Conclusion: 3D printing effectively aids in the classification and preoperative planning of complex tibial plateau fractures, enhancing surgical outcomes and anatomical restoration. Level of Evidence IV, Prospective Study.


RESUMO Objetivo: As fraturas do planalto tibial são fraturas intra-articulares comuns de classificação e tratamento desafiadores aos cirurgiões ortopédicos. Objetivo: Este estudo investiga o uso de impressão 3D para classificar e planejar a cirurgia de fraturas complexas do planalto tibial. Métodos: 54 fraturas complexas do planalto tibial tratadas em nosso hospital de janeiro de 2017 a janeiro de 2019 foram revisadas. Os pacientes foram submetidos a tomografias computadorizadas em espiral pré-operatórias, com dados DICOM processados usando o software Mimics. A tecnologia de impressão 3D gerou modelos precisos em escala 1:1 das fraturas. Estes modelos ajudaram a subdividir as fraturas em sete tipos com base nos planos geométricos do planalto tibial. As abordagens cirúrgicas e as operações simuladas, incluindo a redução da fratura e a colocação de placa, foram planejadas utilizando estes modelos. Resultados: Os modelos 3D representaram com precisão a direção e a extensão da deslocação da fratura e do colapso do planalto. Os modelos facilitaram o planejamento pré-operatório, viabilizando estratégias de reconstrução precisas e a correspondência dos detalhes intraoperatórios com os modelos pré-impressos. Após a cirurgia, a estrutura anatômica do planalto tibial melhorou significativamente em todos os 54 casos. Conclusão: A impressão 3D ajuda na classificação e no planejamento pré-operatório de fraturas complexas do planalto tibial, melhorando os resultados cirúrgicos e a restauração anatômica. Nível de Evidência IV, Estudo Prospectivo.

8.
Rev. Bras. Ortop. (Online) ; 59(2): 206-212, 2024. tab, graf
Artículo en Inglés | LILACS | ID: biblio-1565376

RESUMEN

Abstract Objective To compare the functional outcomes of two circular external fixation techniques to treat complex fractures of the proximal end of the tibia. Materials and Methods The present is a retrospective cohort study with 51 patients who underwent surgical treatment for complex fractures of the tibial plateau with a circular external fixator. There were two groups of patients: 12 subjects underwent treatment with the classic assembly technique, and 39 subjects underwent treatment with the simplified technique. The variables analyzed included age, sex, injury mechanism, trauma energy, associated injuries, fixator type, time of fixator use, and clinical-radiographic outcomes. The classic technique mainly uses transfixing Kirschner wires, while the simplified one replaces the Kirschner wires with Schanz pins in the distal block of the circular external fixator. Result There were no statistically significant differences (p> 0.05) between the two groups concerning the clinical-radiographic outcomes, including fracture consolidation, quality of joint fracture reduction, range of motion, lower limbs residual discrepancy, and postoperative pain. Conclusion We suggest that the simplified technique, using Schanz pins instead of Kirschner wires, can be a viable and effective alternative to treat complex fractures of the proximal end of the tibia with a circular external fixator. This simplified approach can offer benefits, such as a lower infection rate and greater patient comfort, without compromising clinical and radiographic outcomes, thus justifying its use.


Resumo Objetivo Comparar os resultados funcionais entre duas técnicas de fixação externa circular utilizadas no tratamento de fraturas complexas da extremidade proximal da tíbia. Materiais e Métodos Trata-se de um estudo de coorte retrospectivo, com 51 pacientes submetidos ao tratamento cirúrgico de fraturas complexas do planalto tibial com fixador externo circular. Os pacientes foram divididos em dois grupos: 12 pacientes tratados com a técnica clássica e 39 pacientes tratados com a técnica simplificada. As variáveis analisadas incluíram idade, sexo, mecanismo da lesão, energia do trauma, lesões associadas, tipo de fixador, tempo de uso do fixador e resultados clínico-radiográficos. A técnica clássica lança mão principalmente de fios de Kirschner transfixantes, e a simplificada substitui os fios de Kirschner por pinos de Schanz no bloco distal do fixador externo circular. Resultados A partir da comparação das montagens, não encontramos diferenças estatisticamente significativas (p> 00,5) entre os dois grupos em relação aos resultados clínico-radiográficos, incluindo a consolidação da fratura, a qualidade da redução da fratura articular, a amplitude de movimento, a discrepância residual na medida dos membros inferiores e a dor do paciente no pós-operatório. Conclusão Sugerimos que a técnica simplificada, utilizando pinos de Schanz no lugar dos fios de Kirschner, pode ser uma alternativa viável e eficaz no tratamento de fraturas complexas da extremidade proximal da tíbia com fixador externo circular. Essa abordagem simplificada pode oferecer benefícios, como menor taxa de infecção e maior conforto para o paciente, sem comprometer os resultados clínicos e radiográficos, o que justifica, o seu uso.


Asunto(s)
Humanos , Hilos Ortopédicos , Fijadores Externos , Técnica de Ilizarov , Fracturas de la Meseta Tibial/terapia
9.
Injury ; 54 Suppl 6: 111021, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-38143110

RESUMEN

BACKGROUND: Posterior tibial plateau fractures, including avulsion fractures of the posterior cruciate ligament (PCL) insertion, represent a challenge for the orthopedic trauma surgeon. These injuries have gained a new perspective both diagnostically and therapeutically after the regular use of multiplanar computed tomography. In the herein study, we describe the outcome of patients sustaining a tibial plateau fracture with posterior articular involvement treated by open reduction and internal fixation (ORIF) using our modified gastrocnemius splitting anatomic approach. METHODS: This observational retrospective descriptive study was conducted at Complejo Medico de la Policia Federal Argentina Churruca-Visca. All patients were treated by ORIF by our team through our modified gastrocnemius splitting anatomic approach, and followed-up for a minimum of 12 months. RESULTS: A total of 18 patients sustaining plateau fracture were treated by this approach. Satisfactory tomographic reduction with articular gap and/or step-off <2 mm was achieved in 16. The mean time to the return to activities of daily living was 192.2 days. CONCLUSION: The modified gastrocnemius splitting anatomic approach represents a good alternative for the management of tibial plateau fractures involving the posterior quadrants.


Asunto(s)
Fracturas de la Tibia , Fracturas de la Meseta Tibial , Humanos , Estudios Retrospectivos , Actividades Cotidianas , Fijación Interna de Fracturas/métodos , Tibia/diagnóstico por imagen , Tibia/cirugía , Fracturas de la Tibia/diagnóstico por imagen , Fracturas de la Tibia/cirugía , Resultado del Tratamiento
10.
Injury ; 54 Suppl 6: 110741, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-38143118

RESUMEN

PURPOSE: Classifying tibial plateau fractures is paramount in determining treatment regimens and systemizing decision making. The original AO classification described by Müller in 1996 and the Schatzker classification of 1970 are the most cited classifications for tibial plateau fractures, demonstrating substantial to almost perfect agreement. The main problem with these classifications schemes is that they lack the detail required to convey the variety of fracture patterns encountered. In 2018, the AO foundation published a new classification system for proximal tibia fractures, highlighting a more complete and detailed number of categories and subcategories. We sought to independently determine inter and intraobserver agreement of the AO classification system, compared to the previous systems described by Müller and Schatzker. METHODS: One hundred seven consecutive tibial plateau fractures were screened, and a representative data set of 69 was created. Six independent evaluators (three knee surgeons, three senior orthopedic residents) classified the fractures using the original AO, the Schatzker and the new AO classifications. After six weeks, the 69 cases were randomized and reclassified by all evaluators. The Kappa coefficient (k) was calculated for inter- and intraobserver correlation and is expressed with 95% confidence intervals. RESULTS: interobserver agreement was moderate for all three classifications. k = 0.464 (0.383-0.560) for the original AO; k = 0.404 (0.337-0.489) for Schatzker; and k = 0.457 (0.371-0.545) for the base categories of the new AO classification. The inclusion of subcategories and letter modifiers to the new classification worsened agreement to k = 0.358 (0.302-0.423) and k = 0.174 (0.134-0.222), respectively. There were no significant differences between knee surgeons and residents for the new classification. Intra-observer correlation was also moderate for each of the scores: k = 0.630 (0.578-0.682) for the original AO; k = 0.623 (0.569-0.674) for Schatzker; and k = 0.621 (0.566-0.678) for the new AO base categories; without differences between knee surgeons or residents. CONCLUSIONS: This study demonstrated an adequate inter and intra-observer agreement for the new AO tibial plateau fractures classification system for its base categories, but not at the subcategory or letter modifier levels.


Asunto(s)
Ortopedia , Fracturas de la Tibia , Fracturas de la Meseta Tibial , Humanos , Variaciones Dependientes del Observador , Reproducibilidad de los Resultados , Fracturas de la Tibia/diagnóstico por imagen
11.
Kinesiologia ; 42(2): 127-131, 20230615.
Artículo en Español, Inglés | LILACS-Express | LILACS | ID: biblio-1552472

RESUMEN

Objetivo. Analizar el rendimiento biomecánico de las placas de tibia proximal utilizadas en fracturas de platillos tibiales evaluado a través de modelos de elementos finitos. Métodos. Se realizará una búsqueda exhaustiva en PubMed/Medline, Embase, Lilacs, Web of Science y Google Scholar. No se utilizará ninguna restricción de idioma o estado de publicación. Dos revisores examinarán de forma independiente los posibles artículos elegibles, de acuerdo con los criterios de selección predefinidos. Se incluirán los estudios que evalúen el rendimiento de los platillos tibiales proximales utilizados en las fracturas del platillo tibial evaluadas mediante el análisis de elementos finitos. La extracción de datos sobre las características del estudio, los métodos, los resultados y la evaluación del riesgo de sesgo se realizará mediante un formulario estandarizado. Considerando el diseño de estudio no se requiere evaluación por comité de ética. Los resultados de esta revisión se difundirán a través de la publicación en revistas revisadas por pares, redes sociales y congresos de la especialidad. Se espera que los resultados de esta revisión permitan optimizar los resultados del manejo quirúrgico de las fracturas de platillos tibiales. Número de registro PROSPERO: CRD42023396015.


Objetive. To analyze the biomechanical performance of proximal tibial plates used in tibial plate fractures evaluated through finite element modeling. Methods. A comprehensive search will be conducted in PubMed/Medline, Embase, Lilacs, Web of Science, and Google Scholar. No language or publication status restrictions will be used. Two reviewers will independently review potential eligible articles according to predefined selection criteria. Studies evaluating the performance of proximal tibial splints used in tibial splint fractures assessed by finite element analysis will be included. Data extraction on study characteristics, methods, results, and risk of bias assessment will be performed using a standardized form. Considering the study design, evaluation by an ethics committee is not required. The results of this review will be disseminated through publication in peer-reviewed journals, social networks and specialty congresses. It is expected that the results of this review will allow optimizing the results of the surgical management of tibial plate fractures. PROSPERO registration number: CRD42023396015.

12.
Rev. venez. cir. ortop. traumatol ; 55(1): 20-28, jun. 2023. graf, tab, ilus
Artículo en Español | LILACS, LIVECS | ID: biblio-1512025

RESUMEN

Las fracturas de meseta tibial compleja se asocian a traumatismo de alta energía, principalmente en accidentes de motocicleta, siendo un desafío para el cirujano ortopedista. En la década de 1970, Schatzker propuso una clasificación radiológica para las fracturas de la meseta tibial, que destacaba la morfología de los seis tipos principales. Las imágenes de tomografía computarizada y tridimensional, han cambiado la comprensión y el tratamiento de las fracturas de la meseta tibial. Recientemente, esa clasificación original se complementó con una más amplia; puesto que, se introdujo el fragmento en cuña dividida y la continuidad de la columna posterior como determinantes de la estabilidad articular y el papel fundamental que desempeña en el tratamiento de las fracturas de la meseta tibial, con ellos también la importancia de abordajes quirúrgicos que permitan la visualización posterior para una adecuada reducción. El estudio documenta las técnicas de fijación interna y abordajes posteriores realizadas en el IAHULA, valorando los resultados clínicos en cuanto a dolor y satisfacción del paciente, como consolidación, pseudoartrosis o falla en la técnica de osteosíntesis realizada. El resultado a partir de las escalas de evaluación de la AO y KOOS, arrojaron que, con un efecto excelentes se agrupa un 28,6% y bueno a un 42,9%, indicando la importancia de la fijación de la columna posterior, para prevenir artrosis postraumática temprana e inestabilidad articular(AU)


A complex fracture of the posterior tibial plateau are related to high energy traumatisms, mainly during motorcycle accidents, becoming a challenge to the ortopedic surgen. During the seventies, Stchatzker proposed a radiologic classification for the tibial plateau fractures that pointed the morphology of six main types. The computarized and tridimensional tomographic images have changed the comprehension and treatment of these fractures. Recently, the original classification was complemented with a more broaded approach due to the introduction of the fragment in divided crib and the continuity of the posterior column as factors determining the articular stability and the fundamental roll played in the treatment of fractures of the tibial plateau, as well as the important roll of surgical approaches that allow the posterior visualization for a correct reduction. This research documents the technics of internal fixation and posterior approach developed in the IAHULA, evaluating the clinic results about patients' pain level and comfort, as well as the radiologic findings of consolidation, pseudoarthrosis, or fail in the technic of osteosynthesis developed. The results from a point of view of the evaluation scales of the AO and KOOS, show 28.6% with excellent outcomes, and 42.9% with good outcomes, indicating the importance of the fixation of the posterior column to prevent early start of posttraumatic arthrosis and articular instability(AU)


Asunto(s)
Humanos , Masculino , Femenino , Adolescente , Adulto , Recolección de Datos , Fijación Interna de Fracturas , Accidentes de Transporte Terrestre , Fracturas de la Meseta Tibial
13.
Injury ; 2023 Mar 02.
Artículo en Inglés | MEDLINE | ID: mdl-36894468

RESUMEN

Tibial plateau fractures with significant joint depression and metaphyseal comminution pose a challenge. In order to prevent the collapse of the articular surface, some authors propose filling the subchondral void created during reduction with bone graft/substitute, which can add further complications. We present two cases of tibial plateau fractures with severe joint depression of the lateral condyle; both treated with a periarticular rafting construct, in one caseadditional bone substitute was used and in the other case no bone graft/substitute was used; their final outcomes were reported. The treatment of joint depression in tibial plateau fractures using periarticular rafting constructs without bone graft, may be also a valid option, to achieve good final results without the morbidity associated with the use of bone graft/substitutes.

14.
Rev. med. Urug ; 39(1): e401, 2023.
Artículo en Español | LILACS, BNUY | ID: biblio-1431903

RESUMEN

Objetivo: comparar si existe diferencia en resultados clínicos, radiológicos y funcionales con el uso de diferentes tipos de injertos óseos o sustitutos sintéticos, así como tiempo quirúrgico y consolidación para el tratamiento de fracturas de platillo tibial con hundimiento articular en pacientes mayores de 18 años. Material y método: se realizó una búsqueda sistematizada en bases de datos de literatura médica, PubMed, Lilacs, Scielo, Cochrane y portal Timbó. Se utilizaron términos "tibial plateau fracture", "bone grafting", "bone substitutes". Se incluyeron estudios comparativos en seres humanos, pacientes mayores de 18 años, fracturas de platillo tibial que asociaron hundimiento articular, en los cuales se realizó aporte de injerto óseo o material sintético. Artículos en español, inglés, portugués. Publicaciones enero 1980 y diciembre 2021. Se obtuvieron 10 artículos. Resultados: los tipos de injertos y sustitutos óseos encontrados fueron 10. Las muestras en sumatoria total 524 pacientes. La edad promedio fue 49 años. El promedio de seguimiento fue de 12 meses. Se dividieron los estudios en tres grupos: comparación entre injerto autólogo (IOA) e injerto alogénico, IOA con sustitutos sintéticos, y los que comparan sustitutos sintéticos entre sí. El aloinjerto y los sustitutos sintéticos demostraron no ser inferiores en resultados clínicos, funcionales e imagenológicos, mejorando los tiempos intraoperatorios y disminuyendo complicaciones en el sitio donante con respecto al IOA. Conclusiones: el IOA continúa siendo el gold standard a pesar de sus posibles complicaciones vinculadas al sitio donante. El aloinjerto y los sustitutos sintéticos representan una opción válida para tratar estas lesiones.


Objective: to find out whether there are clinical, radiological and functional differences when using different types of bone grafts or synthetic substitutes, as well as surgical times and consolidation to treat depressed tibial-plateau fractures in patients older than 18 years old. Method: a systematized search was conducted in medical literature, PubMed, Lilacs, Scielo, Cochrane and Timbó portal databases using the following terms: "tibial plateau fracture", "bone grafting", "bone substitutes". The study included comparative studies in human patients older than 18 years old with depressed tibial-plateau fractures who were treated with bone grafts or synthetic materials. Publications in Spanish, English and Portuguese, between January, 1980 and December, 2021 were included in the search, what resulted in 10 articles found. Results: there were 10 kinds of bone grafts and bone substitutes found. Samples added up to 524 patients. Average age was 49 years old. Average follow up was 12 months. Studies were divided into 3 groups: comparison between autologous bone grafts and allogenic bone grafts, comparison between autologous grafts and synthetic substitutes and studies comparing synthetic substitutes with one another. Allogenic grafts and synthetic grafts proved at least equivalent in terms of clinical, functional and imaging studies results, improving intraoperative times and reducing complications in donor site when compared to autologous grafts. Conclusions: autologous grafts continue to be the gold standard despite possible complications associated to the donor site, and allogenic grafts and synthetic substitutes constitute a valid option to treat these lesions.


Objetivo: comparar os resultados clínicos, radiológicos e funcionais com o uso de diferentes tipos de enxertos ósseos ou substitutos sintéticos, bem como tempo cirúrgico e consolidação para o tratamento de fraturas do platô tibial com colapso articular em pacientes com mais de 18 anos. Material e método: foi realizada busca sistemática nas bases de dados da literatura médica, PubMed, Lilacs, SciELO, Cochrane e portal Timbó. Utilizaram-se os termos "tibial plateau fracture", "bone grafting", "bone substitutes". Foram incluídos estudos comparativos incluindo seres humanos maiores de 18 anos e fraturas do platô tibial associadas a colapso articular, nas quais foi realizado enxerto ósseo ou sintético, publicados entre janeiro de 1980 e dezembro de 2021 em espanhol, inglês e português. Foram obtidos 10 artigos. Resultados: foram identificados 10 tipos de enxertos e substitutos ósseos. 524 pacientes com idade média de 49 anos foram estudados. O seguimento médio foi de 12 meses. Os estudos foram divididos em 3 grupos: comparação entre enxerto autólogo (IOA) e enxerto alogênico, IOA com substitutos sintéticos e substitutos sintéticos entre si. O aloenxerto e os substitutos sintéticos mostraram-se não inferiores nos resultados clínicos, funcionais e de imagem, melhorando os tempos intraoperatórios e reduzindo as complicações da área doadora em relação à IOA. Conclusões: o IOA continua a ser o padrão ouro apesar de suas possíveis complicações relacionadas ao local doador; tanto o aloenxerto como os substitutos sintéticos representam uma opção válida para tratar essas lesões.


Asunto(s)
Fracturas de la Tibia/cirugía , Sustitutos de Huesos , Fracturas de la Meseta Tibial/cirugía
15.
Multimed (Granma) ; 26(3): e2241, mayo.-jun. 2022. graf
Artículo en Español | LILACS-Express | LILACS | ID: biblio-1406106

RESUMEN

RESUMEN Introducción: la artropatía enteropática representa una manifestación derivada de complicaciones inflamatorias intestinales. Presentación del caso: paciente de 53 años de edad, de piel blanca, femenina, que sufrió caída de sus pies, con trauma en rodilla izquierda que le ocasionó fractura de meseta tibial izquierda. Discusión: los estudios radiológicos fueron positivos y confirman el diagnóstico de la artropatía enteropática y fractura de platillos tibiales, se aplicaron pautas de tratamientos integradores funcionales. Conclusiones: con los tratamientos el paciente reportó efectos beneficiosos, se lograron los objetivos propuestos en la rehabilitación, así como la incorporación de la paciente a la sociedad con un mínimo de discapacidad e independencia.


ABSTRACT Introduction: enteropathic arthropathy represents a manifestation derived from intestinal inflammatory complications. Case presentation: 53-year-old white-skinned female patient who suffered a fall from her feet, with trauma to the left knee that caused a fracture of the left tibial plateau. Discussion: the radiological studies were positive and confirm the diagnosis of enteropathic arthropathy and tibial plateau fractures, functional integrative treatment guidelines were applied. Conclusions: with the treatments the patient reported beneficial effects, the objectives proposed in the rehabilitation were achieved, as well as the incorporation of the patient into society with a minimum of disability and independence.


RESUMO Introdução: a artropatia enteropática representa uma manifestação derivada de complicações inflamatórias intestinais. Apresentação do caso: Paciente do sexo feminino, 53 anos, branca, que sofreu queda dos pés, com trauma no joelho esquerdo que ocasionou fratura do platô tibial esquerdo. Discussão: os estudos radiológicos foram positivos e confirmam o diagnóstico de artropatia enteropática e fraturas do planalto tibial, foram aplicadas diretrizes de tratamento integrativo funcional. Conclusões: com os tratamentos o paciente relatou efeitos benéficos, os objetivos propostos na reabilitação foram alcançados, bem como a incorporação do paciente à sociedade com um mínimo de incapacidade e independência.

16.
Rev. Assoc. Méd. Rio Gd. do Sul ; 66(1): 01022105, 20220101.
Artículo en Portugués | LILACS | ID: biblio-1425002

RESUMEN

O presente trabalho avaliou os aspectos epidemiológicos das fraturas do platô tibial tratados cirurgicamente no Serviço de Ortopedia e Traumatologia do Hospital Santo Antônio, em Blumenau/SC. O trabalho analisou, retrospectivamente, por revisão de prontuários, 62 casos de fratura do planalto tibial tratados entre 2016-2018, nos quesitos idade, gênero, lateralidade, mecanismo lesional, lesões associadas, classificação de Schatzker e complicações. A média de idade foi de 44,8 anos ±14,4; entre os homens foi de 48 anos ±17,3; entre as mulheres de 43,7 anos ±13,3 anos. A incidência foi de 14,2 casos/105 hab/ano; por gênero, em homens 21,1 casos/105 hab/ano em relação à de mulheres, de 7,6 casos/105 hab/ano. O lado mais acometido foi o esquerdo, 57% dos casos, 40% à direita e 3% com bilateralidade. Mecanismos lesionais relatados: acidente de motocicleta 63%; queda de nível 11%; atropelamento 6%; agressão 5%; bicicleta 3%; desportivo 3%; carro 3%; própria altura 3% e quadriciclo 2%. Lesões associadas estiveram presentes em 33,9% da amostra, mais comuns nos membros inferiores, 24%. Optou-se pela classificação de Schatzker, com tipo VI 53%, tipo II 20%, tipo I 12% , tipo III 7%, tipo IV 5%, tipo V 3%. As complicações registradas nos prontuários totalizaram 43,5% da amostra. Perda parcial de amplitude de movimento foi a mais relatada, com 17,7% da amostra. Infecção da ferida operatória apresentou-se em 11,7% da amostra.


This study evaluated the epidemiological aspects of tibial plateau fractures surgically treated in the Hospital Santo Antônio orthopedics and traumatology service in Blumenau, SC, Brazil. The medical records of 62 cases of tibial plateau fracture treated between 2016 and 2018 were retrospectively analyzed regarding age, sex, laterality, mechanism of lesion, associated injuries, Schatzker classification, and complications. The mean age was 44.8 years (SD, 14.4) for the overall sample, 48 years (SD, 17.3) for men, and 43.7 years (SD, 13.3) for women. The incidence was 14.2 cases per 100,000 residents per year for the overall sample, 21.1 cases per 100,000 residents per year for men, and 7.6 cases per 100,000 residents per for women. The left side was more affected (57%) than the right (40%), and 3% were bilateral. The reported mechanisms of injury were: motorcycle accident (63%), fall from a height (11%), being run over by a vehicle (6%), assault (5%), bicycle accident (3%), sports (3%), car accident (3%), fall from standing height (3%) and quadricycle accident (2%). There were associated injuries in 33.9% of the sample, most often in the lower limbs (24%). Fracture types were classified according to the Schatzker system: type VI 53%, type II 20%, type I 12%, type III 7%, type IV 5%, type V 3%. Complications were reported in 43.5% of the sample, with partial loss of range of motion being the most common (17.7%). Surgical wound infection occurred in 11.7% of the sample.


Asunto(s)
Fracturas de la Meseta Tibial
17.
Acta Vet. Brasilica ; 16(4): 323-328, 2022. ilus
Artículo en Inglés | VETINDEX | ID: biblio-1432539

RESUMEN

One dog, Golden Retriever, 5 months old, was seen complaining of lameness and pain in the left pelvic limb. Avulsion of the tibial crest was diagnosed by radiographic means, which was corrected with a tension band. The absence of postoperative radiographic monitoring and the non-removal of the apparatus led to the early closure of the cranial tibial physis with continuous flow growth, resulting in pain, functional loss of the limb after one year and at a 13.2º tibial plateau angle negative. The biomechanical alteration of the limb was corrected using the inverted TPLO technique, converting the angle of the tibial plateau to 5.3 positive, without a rockback evidenced in 30, 60, 90 days up to four months after the operation. The objective of this case report is to describe the surgical correction with the inverted TPLO technique in a case of angle of the negative tibial plateau secondary to not removing the tension band applied in avulsion of the growing tibial crest. After 120 days, the dog was presented fully recovery and weight-bearing without any complication.


Um cão, Golden Retriever, de 5 meses de idade, foi atendido com queixa de claudicação e dor em membro pélvico esquerdo. Diagnosticou-se por meio radiográfico a avulsão da crista da tíbia, a qual foi corrigida com banda de tensão. A ausência de acompanhamento radiográfico pós-operatório e a não retirada do aparato levou ao fechamento precoce da fise tibial cranial com crescimento contínuo da caudal, resultando em dor, perda funcional do membro após um ano e em um ângulo de platô tibial de 13,2º negativos. A alteração biomecânica do membro foi corrigida por meio da técnica de TPLO invertida, convertendo o ângulo do platô tibial em 5,3º positivos, sem rockback evidenciado em 30, 60, 90 dias até quatro meses de pós-operatório. O objetivo desse relato de caso é descrever a correção cirúrgica com a técnica de TPLO invertida em um caso de ângulo do platô tibial negativo secundário a não retirada de banda de tensão aplicada em avulsão da crista da tíbia em crescimento. Após 120 dias, o paciente apresentou recuperação total com adequado suporte do peso no membro, sem qualquer complicação.


Asunto(s)
Animales , Perros , Osteotomía/veterinaria , Tibia/lesiones , Fracturas por Avulsión/veterinaria , Fracturas de la Meseta Tibial/cirugía
18.
An. Facultad Med. (Univ. Repúb. Urug., En línea) ; 8(2): e301, dic. 2021. ilus, tab
Artículo en Español | LILACS, UY-BNMED, BNUY | ID: biblio-1358052

RESUMEN

Objetivo: El objetivo del presente estudio es explorar y describir resultados y experiencias en el tratamiento de las fracturas de platillo tibial Schatzker1 I-IV con asistencia artroscópica para obtener reducción como parte de la técnica de fijación interna (ARIF). Metodología: Se realizó una búsqueda sistematizada en diferentes motores de búsqueda como Pubmed y Lilacs. Se buscó con la misma metodología por 2 revisores independientes utilizando términos MESH "Tibial Fracture", "Arthroscopic". Se incluyeron artículos publicados en los últimos 5 años (2014 a Setiembre 2020), que muestren resultados clínicos de los procedimientos, en inglés o español, en humanos y mayores de 18 años. Resultados: Siguiendo los criterios de inclusión se identificaron 114 títulos, y finalmente 9 artículos fueron incluidos en nuestra revisión sistematizada. De los 9 artículos revisados 5 corresponden a series de casos con un nivel de evidencia IV, 3 corresponden a estudios comparativos retrospectivos entre técnicas de reducción abierta y fijación interna (ORIF) y ARIF con nivel de evidencia III y un estudio corresponde a un nivel de evidencia I. Un total de 217 pacientes fueron intervenidos mediante ARIF en nuestra revisión, el tiempo promedio de seguimiento fue de 24.9 meses (12-90 m), en cuanto al tipo de fractura las más frecuentes fueron las fracturas de platillo tibial Schatzker II y III, la lesión asociada más frecuente fue la lesión meniscal seguida de la rotura del ligamento cruzado anterior. En cuanto al porcentaje total de resultados obtenidos independientemente de cada score utilizado, el 98% aproximadamente obtuvo resultados buenos o excelentes. El porcentaje de complicaciones operadas con asistencia artroscópica resultó ser aproximadamente del 6.5%, siendo la complicación más frecuente la trombosis venosa profunda con 6 casos. Conclusiones: De nuestra revisión podemos concluir que la asistencia artroscópica es útil en el tratamiento de las fracturas de platillo tibial Schatzker I-IV, siendo una técnica que provee resultados funcionales satisfactorios, sin incrementar el número de complicaciones y permite tratar lesiones asociadas en el mismo acto.


Objective: The objective of this study is to explore the experience and the results of Schatzker1 I-IV tibial plateau fractures internal fixation technique (ARIF) with arthroscopic assistance Methodology: A systematic review was carried out in different search engines such as Pubmed and Lilacs. The same methodology was applied by two independent reviewers using MESH terms "Tibial Fracture", "Arthroscopic". Articles published in the last 5 years (2014 to September 2020) were included, showing clinical results of the procedures, in English or Spanish, in humans and over 18 years of age. Results: Following the inclusion criteria, 114 titles were identified, and finally 9 articles were included in our systematic review. Of the 9 articles reviewed, 5 were case series (level of evidence IV), 3 retrospective comparative studies between open reduction and internal fixation techniques (ORIF) and ARIF with level of evidence III and one study was level of evidence I. A total of 217 patients underwent ARIF surgery in our review, the average follow-up time was 24.9 months (12-90 m), in terms of the type of fracture, the most frequent were Schatzker II tibial plateau fractures and III, the most frequent associated injury was meniscal injury followed by anterior cruciate ligament tear. Regarding the total percentage of results obtained independently of each score used, approximately 98% obtained good or excellent results. The percentage of complications with arthroscopic assistance turned out to be approximately 6.5%, the most frequent complication being deep vein thrombosis with 6 cases. Conclusions: From our review we can conclude that arthroscopic assistance is useful in the treatment of Schatzker I-IV tibial plateau fractures, since it provides satisfactory functional results, without increasing the number of complications and allows treating associated injuries simultaneously.


Objetivo: o objetivo deste estudo é explorar e descrever os resultados e experiências no tratamento das fraturas do planalto tibial de Schatzker1 I-IV com auxílio artroscópico para obter redução como parte da técnica de fixação interna (ARIF). Metodologia: : Foi realizada uma busca sistemática em diferentes motores de busca, como Pubmed e Lilacs. Foi pesquisado com a mesma metodologia por 2 revisores independentes usando os termos do MESH "Tibial Fracture", "Arthroscopic". Foram incluídos artigos publicados nos últimos 5 anos (2014 a setembro de 2020), mostrando resultados clínicos dos procedimentos, em inglês ou espanhol, em humanos e maiores de 18 anos. Resultados: Seguindo os critérios de inclusão, 114 títulos foram identificados e, finalmente, 9 artigos foram incluídos em nossa revisão sistemática. Dos 9 artigos revisados, 5 correspondem a séries de casos com nível de evidência IV, 3 correspondem a estudos comparativos retrospectivos entre técnicas de redução aberta e fixação interna (ORIF) e ARIF com nível de evidência III e um estudo corresponde a nível de evidência . evidências I. Um total de 217 pacientes foram submetidos a ARIF em nossa revisão, o tempo médio de acompanhamento foi de 24,9 meses (12-90 m), em termos do tipo de fratura, as mais frequentes foram as fraturas do planalto tibial de Schatzker II e III , a lesão associada mais frequente foi a lesão meniscal seguida de ruptura do ligamento cruzado anterior. Em relação ao percentual total de resultados obtidos independentemente de cada escore utilizado, aproximadamente 98% obtiveram resultados bons ou excelentes. O percentual de complicações operadas com assistência artroscópica revelou-se em torno de 6,5%, sendo a complicação mais frequente a trombose venosa profunda com 6 casos. Conclusões: Da nossa revisão podemos concluir que a assistência artroscópica é útil no tratamento das fraturas do planalto tibial de Schatzker I-IV, sendo uma técnica que fornece resultados funcionais satisfatórios, sem aumentar o número de complicações e permite tratar lesões associadas no mesmo ato.


Asunto(s)
Humanos , Masculino , Femenino , Adulto , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Artroscopía/métodos , Fracturas de la Tibia/cirugía , Artroscopía/efectos adversos , Fracturas de la Tibia/clasificación
19.
Acta ortop. mex ; 35(4): 322-326, jul.-ago. 2021. graf
Artículo en Español | LILACS-Express | LILACS | ID: biblio-1374194

RESUMEN

Resumen: Introducción: Las fracturas de platillo tibial por mecanismos de alta energía son lesiones graves que ocurren sobre una articulación de carga. Son difíciles de abordar, ya que además de afectar la estructura ósea de la pierna suelen tener lesiones de partes blandas asociadas. Objetivo: Evaluar los resultados radiológicos y funcionales de las fracturas de platillo tibial de alta energía con un mínimo seguimiento de un año. Material y métodos: Estudio retrospectivo, observacional y multicéntrico. Análisis de los resultados radiológicos y funcionales en el tratamiento de fracturas de platillo tibial de alta energía tratadas mediante reducción abierta y fijación interna (RAFI) entre 2014 y 2019. Resultados: 54 fracturas tratadas mediante RAFI. Seguimiento un año, 98.1% de consolidación en 13 semanas de promedio, 83.4% sin alteraciones del eje en plano coronal, 74% sin ensanchamiento articular postoperatorio. Escalas funcionales: Lysholm 82.1 puntos promedio y Oxford Knee Score (OKS) 39.5 puntos promedio. Conclusión: El rango de movilidad articular se redujo luego de una fractura de platillos tibiales de alta energía, pero con buenos resultados funcionales. Cuanto menor deseje y menor ensanchamiento radiográfico postoperatorio, se obtienen mejores resultados.


Abstract: Introduction: The tibial plateau fractures due to high-energy mechanisms are serious injuries that occur on a load bearing joint. These are difficult to approach because, also affect the bone structure of the leg, they usually have associated soft tissue injuries. Objective: To evaluate the radiological and functional results of high-energy tibial plateau fractures with a minimum follow-up of one year. Material and methods: Retrospective, observational and multicenter study. Analysis of radiological and functional outcomes in the treatment of high-energy tibial plateau fractures, treated by open reduction and internal fixation (ORIF) between 2014 and 2019. Results: 54 fractures treated by ORIF. Follow-up one year. 98.1% consolidation in 13 weeks on average. 83.4% without alterations of the axis in the coronal plane. 74% without postoperative joint widening. Functional scores: Lysholm 82.1 average points and Oxford Knee Score (OKS) 39.5 average points. Conclusion: The joint range of motion was reduced after a high-energy tibial plateau fracture, but with good functional results. The less off axis and less post-operative radiographic widening, the better results are obtained.

20.
Rev. chil. ortop. traumatol ; 62(1): 39-45, mar. 2021. ilus
Artículo en Español | LILACS | ID: biblio-1342670

RESUMEN

Los fragmentos posterolaterales (FPLs) en fracturas de platillo tibial son frecuentes, pero difíciles de reducir y estabilizar. Actualmente existe controversia sobre cómo deben ser abordados; si bien un abordaje anterolateral es más seguro, este puede ser insuficiente para lograr una correcta reducción. Los abordajes posterolaterales y posteriores ofrecen una visión directa y permiten una fijación con ventaja biomecánica; sin embargo, son más demandantes y exponen al paciente a una mayor morbilidad. A continuación, se presenta una nota técnica sobre la reducción y fijación de FPLs con una placa rim por medio de un abordaje anterolateral extendido a través del espacio paraligamento colateral lateral.


Posterolateral fragments (PLFs) are commonly seen in tibial plateau fractures, but their reduction and fixation are challenging. There is no consensus about the ideal approach to fix this particular fragment. Even though an anterolateral approach is a safe option, it may impair a correct reduction. The posterolateral and posterior approaches offer direct visualization of the fragment, and enable a fixation with a biomechanical advantage; however, they are more demanding and expose the patient to a higher risk if morbidity. The following technical note describes the reduction and fixation of PLFs with a rim plate through an extended anterolateral approach using the paralateral collateral ligament space.


Asunto(s)
Humanos , Masculino , Anciano , Fracturas de la Tibia/cirugía , Placas Óseas , Fijación Interna de Fracturas/métodos , Fracturas de la Tibia/rehabilitación , Ligamentos Colaterales , Fijación Interna de Fracturas/instrumentación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA