Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Catheter Cardiovasc Interv ; 82(2): 292-7, 2013 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-23554013

RESUMEN

AIM: To assess the results of transcatheter aortic valve implantation (TAVI) using the Medtronic CoreValve prosthesis (Medtronic, Minneapolis, MN), without balloon predilation, in high-risk patients with degenerated severe aortic stenosis. METHODS AND RESULTS: Fifty-one consecutive patients who underwent direct TAVI, 98% through a transfemoral approach. Patients were 79 ± 8 years of age, 74% in New York Heart Association classes III or IV and at high risk for surgical valve replacement (mean logistic EuroScore 20 ± 15). Mean aortic valve area was 0.7 ± 0.2 cm(2). Procedural success rate was 94.2%. In-hospital, there were 2 deaths, 1 minor stroke with minimal sequelae, and 14 (28%) pacemaker implantation. At 30 days, there was one additional stroke and no new deaths. The mean postprocedural transprosthetic gradient was 15 ± 5 mm Hg; periprosthetic severe regurgitation was absent and moderate in one case. After a median follow-up of 7 months, there were five additional deaths (two cardiac), while 84% of survivors were in New York Heart Association classes I or II. CONCLUSIONS: These results suggest that direct CoreValve implantation in patients with severe aortic stenosis is feasible and may lead to hemodynamic and clinical improvement in patients who are poor candidates for aortic valve surgery, pending confirmation in larger series with longer follow-up.


Asunto(s)
Estenosis de la Válvula Aórtica/terapia , Válvula Aórtica/patología , Calcinosis/terapia , Cateterismo Cardíaco , Implantación de Prótesis de Válvulas Cardíacas/métodos , Anciano , Anciano de 80 o más Años , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/fisiopatología , Argentina , Calcinosis/diagnóstico , Calcinosis/mortalidad , Calcinosis/fisiopatología , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/instrumentación , Cateterismo Cardíaco/mortalidad , Ecocardiografía Transesofágica , Femenino , Prótesis Valvulares Cardíacas , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Hemodinámica , Mortalidad Hospitalaria , Humanos , Masculino , Persona de Mediana Edad , Proyectos Piloto , Estudios Prospectivos , Diseño de Prótesis , Sistema de Registros , Índice de Severidad de la Enfermedad , Factores de Tiempo , Tomografía Computarizada por Rayos X , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA