Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 33
Filtrar
1.
Artículo en Inglés | MEDLINE | ID: mdl-39230718

RESUMEN

BACKGROUND: Stem anteversion (SA) in total hip arthroplasty (THA) is crucial for postoperative outcomes, affecting dislocation risk and hip function. Accurate SA placement is challenged by intraoperative estimation methods, with discrepancies reported between predicted and true SA. This study investigates the effect of conventional methods and intraoperative fluoroscopic confirmation on SA accuracy in THA performed with a direct anterior approach using a traction table. METHODS: This involves 200 patients undergoing primary THA from August 2019 to January 2023, divided into a conventional group (n = 100) and a fluoroscopic group (n = 100). Postoperative SA measurements were conducted using computed tomography scans. Statistical analysis focused on comparing the SA angles and the prevalence of excessive SA (≥>35° and ≥>40°) between the groups. RESULTS: The fluoroscopic group showed a lower average SA angle (24.3° ± 8.3°) compared to the conventional group (30.0° ± 11.3°), with a statistically significant difference (p < 0.01). Excessive SA (≥>40°) was found in 17% of the conventional group, significantly reduced to 5% in the fluoroscopic group (p < 0.01). Similarly, SA exceeding 35° was present in 39% of the conventional group, compared to only 11% in the fluoroscopic group (p < 0.01), indicating a substantial reduction in excessive SA placements with fluoroscopic guidance. DISCUSSION: The study demonstrates that intraoperative fluoroscopic guidance significantly enhances the accuracy of SA placement in THA, reducing the variability and proportion of excessive SA. This suggests a critical reevaluation of conventional estimation methods in favor of fluoroscopic confirmation to improve surgical outcomes. CONCLUSION: Intraoperative fluoroscopic confirmation of knee external rotation angle markedly decreases the proportion of excessive SA and enhances the precision of stem placement in THA with a direct anterior approach. This technique represents a significant advancement in surgical practice, offering a simple and effective method to achieve optimal postoperative results.

2.
Arthroplast Today ; 28: 101458, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39100413

RESUMEN

Background: Stem anteversion plays a crucial role in mitigating postoperative complications in total hip arthroplasty (THA). The application of the combined-anteversion theory in THA necessitates the intraoperative measurement of the stem anteversion angle (SAA). However, estimating SAA intraoperatively poses challenges for surgeons lacking a computer-assisted navigation system. In this study, we assessed the precision of intraoperative SAA measurements using a recently developed device, comparing them with 3-dimensional measurements obtained from postoperative computed tomography. Methods: We examined 127 hips in 127 patients who underwent unilateral THA at our institution. Employing our newly constructed device, attachable to rasping broach handles, we measured the SAA intraoperatively. This process involved incorporating the correction angle derived from the preoperative epicondylar view. We then compared the postoperative SAA with the intraoperative measurements, both with and without the correction angle, to ascertain the device's utility. Results: The device yielded an intraoperative SAA measurement of 17.93 ± 7.53°. In contrast, the true SAA measured on postoperative computed tomography was 26.40 ± 9.73°. The discrepancy between intraoperative and true SAA was 8.94 ± 5.44° (without the correction angle) and 4.93 ± 3.85° (with the correction angle). Accuracy within a discrepancy of <5° was achieved in 77 cases (60.6%), and <10° was achieved in 113 cases (89.0%). The accuracy remained consistent regardless of the stem-placement angle (varus/valgus, or flexion/extension) or the presence of ipsilateral knee osteoarthritis. Conclusions: The SAA-measuring device, attachable to various rasping handles, proves useful for straightforward, cost-effective, and noninvasive intraoperative SAA measurement during THA.

3.
Arthroplasty ; 6(1): 27, 2024 Jun 02.
Artículo en Inglés | MEDLINE | ID: mdl-38824601

RESUMEN

BACKGROUND: In the present study, the surgeon aimed to align the stem at 5° to 25° in anteversion. The robotic technology was used to measure stem anteversion with respect to proximal femur anteversion at different levels down the femur. METHODS: A total of 102 consecutive patients underwent robotic-arm-assisted total hip arthroplasty (RTHA). 3D CT-based preoperative planning was performed to determine femoral neck version (FNV), posterior cortex anteversion (PCA), anterior cortex anteversion (ACA), and femoral metaphyseal axis anteversion (MAA) at 3 different levels: D (10 mm above lesser trochanter), E (the midpoint of the planned neck resection line) and F (head-neck junction). The robotic system was used to define and measure stem anteversion during surgery. RESULTS: Mean FNV was 6.6° (SD: 8.8°) and the mean MAA was consistently significantly higher than FNV, growing progressively from proximal to distal. Mean SV was 16.4° (SD: 4.7°). There was no statistically significant difference (P = 0.16) between SV and MAA at the most distal measured level. In 96.1% cases, the stem was positioned inside the 5°-25° anteversion range. CONCLUSIONS: Femoral anteversion progressively increased from neck to proximal metaphysis. Aligning the stem close to femoral anteversion 10 mm above the lesser trochanter often led to the desired component anteversion.

4.
Orthop Surg ; 16(5): 1101-1108, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38509013

RESUMEN

BACKGROUND: Preoperative evaluation of femoral anteversion to predict postoperative stem anteversion aids the selection of an appropriate prosthesis and optimizes the combined anteversion in total hip arthroplasty (THA) for developmental dysplasia of the hip (DDH). The conventional prediction methods are based on the femoral anteversion measurement at the location of the femoral head and/or neck. However, varied differences between femoral anteversion and postoperative stem anteversion were demonstrated. This study investigated the predictive role of a new method based on the principle of sagittal three-point fixation. METHODS: From January 2017 to December 2018, a total of 133 DDH hips that underwent THA were retrospectively analyzed. There were 76 Crowe type I, 27 type II, and 30 type III hips. The single-wedge stem was used in 49 hips, and the double-wedge stem was used in 84 hips. Preoperative native femoral anteversion at the femoral head-neck junction, anterior cortex anteversion at 2 levels of the lesser trochanter, posterior cortex anteversion at 5 levels of the femoral neck, and postoperative stem anteversion were measured using two-dimensional computed tomography. Predictive anteversion by the new method was calculated as the average anteversion formed by the anterior cortex at the lesser trochanter and the posterior cortex at the femoral neck. RESULTS: For hips with different neck heights, different Crowe types, different stem types, or different femoral anteversions, native femoral anteversion showed widely varied differences and correlations with stem anteversion, with differences ranging from -1.27 ± 8.33° to -13.67 ± 9.47° and correlations ranging from 0.122 (p = 0.705, no correlation) to 0.813. Predictive anteversion formed by the anterior cortex at the lesser trochanter proximal base and posterior cortex 10 mm above the lesser trochanter proximal base showed no significant difference with stem anteversion, with less varied differences (0.92 ± 7.52°) and good to excellent correlations (r = 0.826). CONCLUSION: Adopting our new method, predictive anteversion, measured as the average anteversion of the anterior cortex at the lesser trochanter proximal base and posterior cortex 10 mm above the lesser trochanter proximal base, predicted postoperative stem anteversion more reliably than native femoral anteversion.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Displasia del Desarrollo de la Cadera , Prótesis de Cadera , Humanos , Artroplastia de Reemplazo de Cadera/métodos , Femenino , Masculino , Estudios Retrospectivos , Persona de Mediana Edad , Displasia del Desarrollo de la Cadera/cirugía , Displasia del Desarrollo de la Cadera/diagnóstico por imagen , Anciano , Adulto , Tomografía Computarizada por Rayos X , Diseño de Prótesis
5.
J Orthop Surg Res ; 19(1): 47, 2024 Jan 09.
Artículo en Inglés | MEDLINE | ID: mdl-38195511

RESUMEN

BACKGROUND: High-performance total hip arthroplasty (THA) depends on the accurate position of components. However, femoral anteversion is variable, and current studies only used traditional instruments to evaluate it, such as protractor and spirit level with limited cases. This study aimed to identify the variability in the measured femoral native anteversion and intraoperative stem anteversion under different measurement methods, including intraoperative robotic method. We hypothesized that robotic technology was more accurate than traditional instruments for femoral anteversion evaluation. METHODS: This study included 117 hips of patients who underwent robotic-assisted THA between November 2019 and March 2021. Preoperative native femoral anteversion was measured using a robotic system. Intraoperative femoral stem anteversion was evaluated visually, and then measured with a goniometer and a robotic system, respectively. Variability in the measured femoral native anteversion and intraoperative femoral stem anteversion was calculated and compared. Intraclass correlation coefficient (ICC) and Pearson correlation analysis were used to assess the consistency and correlation of anteversion of different measurements and postoperative CT-measured stem anteversion, respectively. RESULTS: The result of measurement for preoperative native femoral anteversion was more variable than the intraoperative robotic-measured stem anteversion. Intraoperative robotic-measured stem version showed the highest correlation with postoperative CT measurement of stem version (r = 0.806, P < 0.001), while intraoperative surgeon estimation had the lowest correlation coefficient (r = 0.281, P = 0.025). As for the consistency with postoperative CT measurement of femoral stem anteversion, the intraoperative robotic-measured femoral stem version also had the highest value (ICC = 0.892, P < 0.001). CONCLUSION: Native femoral anteversion was variable preoperatively. Using cementless stems, anteversion was also highly variable. Robotic assessment for stem anteversion during surgery was more consistent with the final position than the preoperative assessment and conventional intraoperative estimation.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Procedimientos Quirúrgicos Robotizados , Humanos , Fémur/diagnóstico por imagen , Fémur/cirugía , Periodo Posoperatorio , Tecnología
6.
J Orthop Res ; 2023 Dec 12.
Artículo en Inglés | MEDLINE | ID: mdl-38084832

RESUMEN

To avoid dislocation after total hip arthroplasty, it is desirable to avoid implant impingement during activities of daily living. Numerous simulation studies have been performed at 30° of internal rotation (IR) with 90° of flexion. However, these studies may not reflect the impingement that occurs during activities such as floor sitting, which require a larger IR during flexion. The purpose of this study was to assess the impact of varying IR angles during flexion on the impingement-free safe zone and optimal stem anteversion. In this study, implant impingement simulation was evaluated in computer simulation. The prosthesis used a flat liner, and a 32- or 40-mm femoral head and stem. Three patterns of required IR angle (30° IR/40° IR/50° IR with 90° flexion) combined with 13 directions of the required range of motion were simulated. The optimal stem anteversion to maximize the safe zone was analyzed. Increasing the required IR at 90° flexion decreased the safe zone, particularly with small stem anteversion angles. With a 32-mm head, the desirable stem anteversion at 40° of cup inclination was 15°/25°/35° in required 30° IR/40° IR/50° IR with 90° flexion, respectively. The safe zone area of the 32-mm head was smaller than that of the 40-mm head. For patients who require a larger IR with 90° flexion, the stem and cup target anteversion should be adjusted according to the implant design, head diameter, and patient's required IR at flexion in their lifestyle.

7.
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi ; 37(9): 1075-1080, 2023 Sep 15.
Artículo en Chino | MEDLINE | ID: mdl-37718418

RESUMEN

Objective: To explore the related factors of femoral stem anteversion (FSA) after total hip arthroplasty (THA), so as to provide reference for clinical design of FSA before operation and reduce the risk of hip dislocation after arthroplasty. Methods: Ninty-three patients (103 hips) who underwent THA between October 2021 and September 2022 and met the selection criteria were selected as the study subjects. Among them, there were 48 males and 45 females with an average age of 58.5 years (range, 25-88 years). Body mass index was 18.00-37.84 kg/m 2, with an average of 24.92 kg/m 2. There were 51 cases (57 hips) of osteonecrosis of femoral head, 35 cases (39 hips) of hip osteoarthritis, and 7 cases (7 hips) of congenital hip dysplasia. Based on CT images, the following indicators were measured: preoperative femoral neck anteversion (FNA), preoperative femoral rotation angle (FRA), preoperative acetabular anteversion (AA), and preoperative combined anteversion (CA; the sum of preoperative FNA and AA); postoperative FSA and the change in femoral anteversion angle (the difference between postoperative FSA and preoperative FNA). Based on preoperative X-ray films, the following indicators were measured: femoral cortical thickness index (CTI) and canal flare index (CFI), the proximal femoral medullary cavity was classified according to Noble classification (champagne cup type, normal type, chimney type), neck-shaft angle (NSA), and femoral offset (FO). Pearson correlation analysis, one-way ANOVA, and Point-biserial correlation analysis were used to investigate the correlation between postoperative FSA, postoperative change in femoral anteversion angle, and patient diagnosis, proximal femoral medullary cavity anatomy type, gender, age, as well as preoperative FNA, FRA, AA, CA, NSA, FO, CTI, and CFI. FSA was used as the dependent variable and the independent variables that may be related to it were included for multiple linear regression analysis. Results: Based on CT image measurement, preoperative FNA was (15.96±10.01)°, FRA (3.36±10.87)°, AA (12.94±8.83)°, CA (28.9±12.6)°, postoperative FSA (16.18±11.01)°, and postoperative change in femoral anteversion angle was (0.22±9.98)°. Based on preoperative X-ray films measurements, the CTI was 0.586±0.081; the CFI was 4.135±1.125, with 23 hips classified as champagne cup type, 68 hips as normal type, and 12 hips as chimney type in the proximal femoral medullary cavity anatomy; NSA was (132.87±7.83)°; FO was (40.53±10.11) mm. There was no significant difference between preoperative FNA and postoperative FSA ( t=-0.227, P=0.821). Pearson correlation analysis showed that postoperative FSA was positively correlated with preoperative FNA, preoperative CA, postoperative change in femoral anteversion angle, and age ( P<0.05), while negatively correlated with preoperative FRA ( P<0.05). The postoperative change in femoral anteversion angle were positively correlated with preoperative FRA and postoperative FSA ( P<0.05), and negatively correlated with preoperative CA and FNA ( P<0.05). One-way ANOVA analysis showed that the above two indicators were not correlated with diagnosis and the proximal femoral medullary cavity anatomy type ( P>0.05). Multiple linear regression analysis showed a linear correlation between FSA and FNA, CA, age, and FRA ( F=10.998, P<0.001), and the best fit model was FSA=0.48×FNA-2.551. Conclusion: The factors related to FSA after THA include patient's age, preoperative FNA, CA, FRA and postoperative femoral anteversion, of which preoperative FNA is the most closely related. When designing a surgical plan before surgery, attention should be paid to the patient's preoperative FNA, and if necessary, CT around the hip joint should be scanned to gain a detailed understanding of the proximal femoral anatomical structure.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Femenino , Masculino , Humanos , Persona de Mediana Edad , Fémur/diagnóstico por imagen , Cuello Femoral , Cabeza Femoral , Articulación de la Cadera
8.
J Orthop Sci ; 2023 Aug 16.
Artículo en Inglés | MEDLINE | ID: mdl-37596167

RESUMEN

BACKGROUND: Intraoperative stem anteversion, which is the angle between the lower leg axis and the trial-stem axis with hip flexion and adduction, is generally evaluated by the surgeon's visual estimation during total hip arthroplasty (THA). However, the conventional approach can be influenced by knee osteoarthritis or uncertain surgeon's observation point. Therefore, we developed a new method for measuring the stem anteversion angle in the neutral hip position using an original rod attached to the trial-stem perpendicular to the long axis and parallel to the stem neck. This study aimed to assess the accuracy of our method in comparison with the conventional method of measuring intraoperative stem anteversion angle. METHODS: We measured the intraoperative stem anteversion angle in consecutive 106 hips of 106 patients who underwent cementless primary THA with a tapered wedge stem. Absolute error in the stem anteversion angle was expressed as the difference between intraoperative (common vs. neutral hip positions) and postoperative computed tomography measurements, i.e., true stem anteversion. Additionally, we investigated the factors affecting these errors. RESULTS: The absolute error of measurement was significantly smaller in the neutral hip position than in the common position (3.0° ± 2.5° vs. 8.0° ± 3.9°; p < 0.0001). The factor associated with the error was advanced knee osteoarthritis in the common position, whereas it was not statistically significant in the neutral hip position. CONCLUSIONS: This study suggests that the error in the intraoperative measurement of stem anteversion is decreased by measuring in the neutral hip position during THA.

9.
Artículo en Chino | WPRIM (Pacífico Occidental) | ID: wpr-1009026

RESUMEN

OBJECTIVE@#To explore the related factors of femoral stem anteversion (FSA) after total hip arthroplasty (THA), so as to provide reference for clinical design of FSA before operation and reduce the risk of hip dislocation after arthroplasty.@*METHODS@#Ninty-three patients (103 hips) who underwent THA between October 2021 and September 2022 and met the selection criteria were selected as the study subjects. Among them, there were 48 males and 45 females with an average age of 58.5 years (range, 25-88 years). Body mass index was 18.00-37.84 kg/m 2, with an average of 24.92 kg/m 2. There were 51 cases (57 hips) of osteonecrosis of femoral head, 35 cases (39 hips) of hip osteoarthritis, and 7 cases (7 hips) of congenital hip dysplasia. Based on CT images, the following indicators were measured: preoperative femoral neck anteversion (FNA), preoperative femoral rotation angle (FRA), preoperative acetabular anteversion (AA), and preoperative combined anteversion (CA; the sum of preoperative FNA and AA); postoperative FSA and the change in femoral anteversion angle (the difference between postoperative FSA and preoperative FNA). Based on preoperative X-ray films, the following indicators were measured: femoral cortical thickness index (CTI) and canal flare index (CFI), the proximal femoral medullary cavity was classified according to Noble classification (champagne cup type, normal type, chimney type), neck-shaft angle (NSA), and femoral offset (FO). Pearson correlation analysis, one-way ANOVA, and Point-biserial correlation analysis were used to investigate the correlation between postoperative FSA, postoperative change in femoral anteversion angle, and patient diagnosis, proximal femoral medullary cavity anatomy type, gender, age, as well as preoperative FNA, FRA, AA, CA, NSA, FO, CTI, and CFI. FSA was used as the dependent variable and the independent variables that may be related to it were included for multiple linear regression analysis.@*RESULTS@#Based on CT image measurement, preoperative FNA was (15.96±10.01)°, FRA (3.36±10.87)°, AA (12.94±8.83)°, CA (28.9±12.6)°, postoperative FSA (16.18±11.01)°, and postoperative change in femoral anteversion angle was (0.22±9.98)°. Based on preoperative X-ray films measurements, the CTI was 0.586±0.081; the CFI was 4.135±1.125, with 23 hips classified as champagne cup type, 68 hips as normal type, and 12 hips as chimney type in the proximal femoral medullary cavity anatomy; NSA was (132.87±7.83)°; FO was (40.53±10.11) mm. There was no significant difference between preoperative FNA and postoperative FSA ( t=-0.227, P=0.821). Pearson correlation analysis showed that postoperative FSA was positively correlated with preoperative FNA, preoperative CA, postoperative change in femoral anteversion angle, and age ( P<0.05), while negatively correlated with preoperative FRA ( P<0.05). The postoperative change in femoral anteversion angle were positively correlated with preoperative FRA and postoperative FSA ( P<0.05), and negatively correlated with preoperative CA and FNA ( P<0.05). One-way ANOVA analysis showed that the above two indicators were not correlated with diagnosis and the proximal femoral medullary cavity anatomy type ( P>0.05). Multiple linear regression analysis showed a linear correlation between FSA and FNA, CA, age, and FRA ( F=10.998, P<0.001), and the best fit model was FSA=0.48×FNA-2.551.@*CONCLUSION@#The factors related to FSA after THA include patient's age, preoperative FNA, CA, FRA and postoperative femoral anteversion, of which preoperative FNA is the most closely related. When designing a surgical plan before surgery, attention should be paid to the patient's preoperative FNA, and if necessary, CT around the hip joint should be scanned to gain a detailed understanding of the proximal femoral anatomical structure.


Asunto(s)
Femenino , Masculino , Humanos , Persona de Mediana Edad , Artroplastia de Reemplazo de Cadera , Fémur/diagnóstico por imagen , Cuello Femoral , Cabeza Femoral , Articulación de la Cadera
10.
Clin Biomech (Bristol, Avon) ; 100: 105770, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-36209568

RESUMEN

BACKGROUND: Femoral offset and anteversion have been reported to affect the incidence of dislocation following bipolar hemiarthroplasty, although the magnitudes of contributions of the femoral offset and stem anteversion on dislocation, both singly and in combination is not fully understood. METHODS: Using the CT data of 61 patients (61 hips), including 30 male and 31 female who underwent bipolar hemiarthroplasty, three-dimensional dynamic motion analysis was performed using a modular implant that enabled adjustment of femoral offset and stem anteversion independently. The pattern of impingement and relationship between femoral offset/stem anteversion and range of motion were evaluated using the software. FINDINGS: We found that a higher femoral offset and stem anteversion correlate with a greater range of motion of flexion and internal rotation. Furthermore, an increased femoral offset has a great effect on increasing range of motion of flexion than stem anteversion, and increased both femoral offset and stem anteversion have fewer effect on the flexion, whereas increasing stem anteversion has a great impact on internal rotation than offset, especially in the case with lower femoral anteversion. However, a higher stem anteversion decrease the range of motion of external rotation, whereas a higher femoral offset leads to an increased range of motion of external rotation. INTERPRETATION: We demonstrated that both a higher femoral offset and stem anteversion substantially affected the range of motion in flexion, internal rotation and external rotation. However, these are not independent, but rather mutually confounding, the surgeons should consider retaining femoral/anterior offset in bipolar hemiarthroplasty.


Asunto(s)
Humanos , Femenino , Masculino
11.
Front Surg ; 9: 966617, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36117825

RESUMEN

Background: Precise preoperative planning improves postoperative outcomes in total hip arthroplasty (THA), especially in developmental dysplasia of the hip (DDH) cases. Previous studies used the T-line and midcortical-line as preoperative landmarks to predict postoperative stem anteversion (PSA). However, the most reliable landmark in predicting PSA in DDH patients remains unclear. To find the most reliable measurement to predict the PSA in DDH patients, this study compared the midcortical-line and T-line at different femoral neck levels. Methods: Pre- and postoperative Computed Tomography (CT) scans of 28 hips in 21 DDH patients who received THA were obtained for three-dimensional femoral models. The preoperative CT scan was used to measure the anteversion of the midcortical-line on the axial cross-sectional plane images (AM-CT), the anteversion of the midcortical-line from 3D models (AM-3D), and the T-line from 3D models (AT-3D) at simulated osteotomy planes at 5 and 10 mm heights proximal to the base of the lesser trochanter. The correlation between the preoperative femoral anteversion (AM-CT, AM-3D, AT-3D) and the PSA was assessed to evaluate the prediction accuracy. Results: The correlations between the AM-CT and the PSA were 0.86 (mean difference (MD) = 1.9°) and 0.92 (MD = -3.0°) at 5 and 10 mm heights, respectively. The correlation between the AM-3D and the PSA were 0.71 (MD = -11.6°) and 0.61 (MD = -12.9°) at 5 and 10 mm heights. The AT-3D was significantly greater (MD = 15.4°) than the PSA (p-value <0.01) at 5 mm cutting height, and the correlation between the AT-3D and the PSA was 0.57 (MD = 7.8°) at 10 mm cutting height. Conclusions: The AM-CT at the 10 mm height had the strongest correlation with the PSA and was more reliable in predicting the PSA when compared with the AM-3D and the AT-3D in DDH patients.

12.
J Arthroplasty ; 37(9): 1832-1838, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-35469988

RESUMEN

BACKGROUND: Modular stems require careful follow-up, especially after any design modification. This study investigated the mid- to long-term outcomes of total hip arthroplasty in patients with developmental dysplasia of the hip using the S-ROM-A stem, a modified S-ROM stem for Asians. METHODS: We previously reported short-term outcomes for all 220 dysplastic hips that underwent primary total hip arthroplasty with the S-ROM-A stem. Here, we followed the clinical and radiological outcomes of 201 of the 220 hips (91%) for a mean 11.4 years postoperatively. We also performed multivariate analysis to determine whether large anteversion angle adjustment was associated with increased osteolysis. RESULTS: The cumulative survival rate of the stem at 168 months postoperatively was 97.4%. Two hips underwent revision surgery, including 1 due to neck trunnionosis. Characteristic distal stem fracture occurred in 3 hips (1.5%). Most partial radiolucent lines observed around the sleeve early postoperatively disappeared by 7 years, postoperatively. Mild osteolysis occurred relatively frequently (20%), but a multivariate model adjusted for polyethylene type showed no significant association between the occurrence of osteolysis and anteversion adjustment of the modular stem (stem anteversion decreased ≤-20°, P = .829; stem anteversion increased ≥+20°, P = .619). CONCLUSION: Partial radiolucent lines early postoperatively do not affect long-term outcomes. The clinical benefits of actively adjusting the stem anteversion angle outweigh the mechanical risks. Mild osteolysis, stem fracture, and trunnionosis were relatively frequent complications. Analysis with longer follow-up and more cases are necessary to clearly determine if these complications are associated with the design modification.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Displasia del Desarrollo de la Cadera , Prótesis de Cadera , Osteólisis , Artroplastia de Reemplazo de Cadera/efectos adversos , Artroplastia de Reemplazo de Cadera/métodos , Estudios de Seguimiento , Humanos , Estudios Retrospectivos , Resultado del Tratamiento
13.
Eur J Orthop Surg Traumatol ; 32(3): 497-503, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-34021789

RESUMEN

BACKGROUND: Whether different body positions during surgery affect postoperative stem alignment in total hip arthroplasty (THA) remains unclear. The purpose of this study was to clarify differences in tapered wedge stem alignment between supine and lateral positions in THA under the modified Watson-Jones anterolateral approach. METHODS: We reviewed 242 consecutive, primary cementless THAs performed with ceramic-on-cross-linked polyethylene via the modified Watson-Jones approach in either supine or lateral positions between 2009 and 2015 (supine group: 113 cases; lateral group: 129 cases). No specific reasons to select supine or lateral positions for the surgery were given during the study period. Computed tomography was performed pre- and postoperatively to measure preoperative femoral anteversion and postoperative stem anteversion, respectively. Stem alignment in coronal and sagittal planes was also evaluated. RESULTS: Mean difference in stem anteversion and femoral anteversion was 8.6 ± 9.4 in the supine position and 13.0 ± 11.4 in the lateral position (p = 0.0013). Although no significant difference was seen between groups for stem alignment in the coronal plane, flexed implantation was more likely in the supine group (46/113, 40.7%) than in the lateral group (20/129, 15.5%). A significant correlation was found between femoral anteversion and stem anteversion in both the supine and lateral groups (r = 0.68, p < 0.0001 and r = 0.52, p < 0.0001, respectively). CONCLUSION: Although stem anteversion was more strongly correlated with femoral anteversion in the supine position than in the lateral position, neutral position in the sagittal plane was more likely to be found with the lateral position than with the supine position. Surgeons can achieve ideal stem positioning by considering these results in the modified Watson-Jones approach in both the supine and lateral positions.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Artroplastia de Reemplazo de Cadera/métodos , Fémur/diagnóstico por imagen , Fémur/cirugía , Humanos , Periodo Posoperatorio , Rango del Movimiento Articular
14.
Int Orthop ; 46(4): 725-732, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-34799778

RESUMEN

INTRODUCTION: Inadequate stem version might lead to impingement and instability after cementless total hip arthroplasty (THA). We evaluated (1) the distribution of short-stem anteversion, (2) the proportion of stems with an anteversion less than 5° or larger than 25°, (3) combined cup and stem anteversion, and (4) dislocation rate. MATERIALS AND METHODS: We evaluated the native femoral anteversion and stem anteversion in 340 patients (340 THAs): 144 men and 196 women. Their mean age was 56.2 (22-87) years and mean body mass index was 25.1 (15.2-40.7) kg/m2. The femoral neck anteversion was measured on pre-operative CT scan and the stem anteversion was obtained during the operation. The safe zone of the stem anteversion was defined as 5 to 25°. RESULTS: The femoral neck anteversion ranged from -15 to 61° (mean, 15.0°; SD, ±10.6°). The stem anteversion ranged -7 to 50° (mean, 15.7°; SD, ±9.5°). It was optimal (5-25°) in 71.2% (242/340), insufficient (<5°) in 13.3% (45/340), and excessive (>25°) in 15.6% (53/340). The stem anteversion had a medium correlation with the femoral neck anteversion (correlation coefficient = 0.449). The combined anteversion was 42.0° (range, 35.2-52.3°; SD, ±2.8°). During two to four year follow-up, no hip dislocated. CONCLUSIONS: Short-length stem had a great variability in the anteversion and considerable portion (28.9%, 98/340) of stems had an anteversion outside the safe zone. Surgeons should be aware of this variability of stem anteversion to compensate for abnormal stem anteversion, which might lead to impingement and instability after THA.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Luxaciones Articulares , Artroplastia de Reemplazo de Cadera/efectos adversos , Femenino , Fémur/cirugía , Humanos , Luxaciones Articulares/cirugía , Masculino , Persona de Mediana Edad , Tomografía Computarizada por Rayos X
15.
J Orthop Surg Res ; 16(1): 582, 2021 Oct 09.
Artículo en Inglés | MEDLINE | ID: mdl-34627309

RESUMEN

BACKGROUND: Excessive external femoral rotation (FR) can functionally increase stem anteversion (SA) and is often observed at an early stage after surgery in revision total hip arthroplasty (THA). This study was conducted to investigate the prevalence of external FR, identify the factors associated with external FR, and determine the association of FR and other factors with hip dislocation in revision THA. METHODS: We enrolled 51 revision THA patients (55 hip cases). The patient background, angle of anatomical and functional SA, FR angle, sizes and densities of muscles around the hip joint, impingement distance, and consequence of postoperative hip dislocation were assessed by reviewing their medical history and imaging data that includes computed tomography (CT) scans before and after surgery. RESULTS: Forty-five hip cases (81.8%) showed external FR (mean 13.0°). External FR was significantly correlated with anatomical SA (r = - 0.54) and increase in functional SA (r = 0.36), which was significantly correlated with impingement distance (r = 0.46). The independent factors associated with external FR in multivariate analysis were the anatomical SA, CT densities of the psoas, gluteus medius and maximus muscles, and 2-stage revision (R2 = 0.559). During follow-up period, eight cases of revision THA showed hip dislocation. FR, functional SA, impingement distance, CT density of psoas and gluteus medius muscle, body mass index, number of past operation, and ratio of 2-stage revision THA were significantly different between cases with dislocation and non-dislocation. The odds ratio of FR and impingement distance for hip dislocation was identified as 1.061(95% confidence interval (CI): 1.011-1.114) and 0.901 (95% CI 0.820-0.991), respectively. CONCLUSIONS: Revision THA frequently causes an external FR that functionally increases the SA and impingement risk, particularly in hips with 2-stage revision with psoas and gluteus medius muscle atrophy. Patients who have undergone revision THA and have an excessive external FR may require careful monitoring for possible hip dislocation due to hip joint instability and impingement.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Luxación de la Cadera , Prótesis de Cadera , Artroplastia de Reemplazo de Cadera/efectos adversos , Luxación de la Cadera/diagnóstico por imagen , Luxación de la Cadera/epidemiología , Luxación de la Cadera/cirugía , Articulación de la Cadera/diagnóstico por imagen , Articulación de la Cadera/cirugía , Humanos , Debilidad Muscular , Reoperación , Estudios Retrospectivos
16.
J Arthroplasty ; 36(7): 2393-2401, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-33653630

RESUMEN

BACKGROUND: To create a safe zone, an understanding of the combined femoral and acetabular mating during hip motion is required. We investigated the position of the femoral head inside the acetabular liner during simulated hip motion. We hypothesized that cup and stem anteversions do not equally affect hip motion and combined hip anteversion. METHODS: Hip implant motion was simulated in standing, sitting, sit-to-stand, bending forward, squatting, and pivoting positions using the MATLAB software. A line passing through the center of the stem neck and the center of the prosthetic head exits at the polar axis (PA) of the prosthetic head. When the prosthetic head and liner are parallel, the PA faces the center of the liner (PA position = 0, 0). By simulating hip motion in 1-degree increments, the maximum distance of the PA from the liner center and the direction of its movement were measured (polar coordination system). RESULTS: The effect of modifying cup and stem anteversion on the direction and distance of the PA's change inside the acetabular liner was different. Stem anteversion influenced the PA position inside the liner more than cup anteversion during sitting, sit-to-stand, squatting, and bending forward (P = .0001). This effect was evident even when comparing stems with different neck angles (P = .0001). CONCLUSION: Cup anteversion, stem anteversion, and stem neck-shaft angle affected the PA position inside the liner and combined anteversion in different ways. Thus, focusing on cup orientation alone when assessing hip motion during different daily activities is inadequate.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Acetábulo/cirugía , Fémur/cirugía , Humanos , Rango del Movimiento Articular
17.
J Orthop Surg Res ; 16(1): 27, 2021 Jan 07.
Artículo en Inglés | MEDLINE | ID: mdl-33413529

RESUMEN

BACKGROUND: The femoral component anteversion during surgery is traditionally assessed by a visual assessment of the surgeon and has proven to be imprecise. We sought to determine the accuracy of a digital protractor and a spirit level to measure the stem anteversion during cementless THA. METHODS: A prospective study was conducted among 107 patients (114 hips) who underwent primary cementless THA via posterolateral approach. A pipe with a spirit level was attached to the tibial tubercle and intermalleolar midpoint. While the leg was held perpendicularly to the floor, stem anteversion was estimated by 3 methods: method A by visual assessment; method B by a digital protractor alone; and method C by a digital protractor combined with a spirit level. The angles were compared with the true anteversion measured by postoperative CT scan. RESULTS: The average anteversion by method C (22.8° ± 6.9°, range -2° to 40°) was significantly lower than method A (24.6° ± 5.2°, range 0° to 30°) (p=0.033), but not different from the true anteversion (22.1° ± 8.2°, range -5.4° to 43.1°) (p=0.445). There were no significant differences between method B (23.2° ± 8.2°, range -4° to 45°) and method A, C or the true anteversion. The mean deviation of the intraoperative estimation from the true anteversion was 0.8° ± 3.7° (range -7.1° to 8.0°) by method C; 1.2° ± 5.1° (range -8.8° to 14.3°) by method B; and 2.5° ± 7.4° (range -19.0° to 16.0°) by method A. Estimation error within 5° was found in 107 hips (93.9%) with method C; 86 hips (75.4%) with method B; and 59 hips (51.8%) with method A. CONCLUSION: Accurate estimation of stem anteversion during cementless THA can be determined intraoperatively by the use of a digital protractor and a spirit level. TRIAL REGISTRATION: Thai Clinical Trials Registry ( TCTR 20180326003 ). Registered on 20 March 2018. Retrospectively registered.


Asunto(s)
Artroplastia de Reemplazo de Cadera/métodos , Anteversión Ósea/diagnóstico , Fémur/cirugía , Prótesis de Cadera , Ajuste de Prótesis/métodos , Adulto , Anciano , Anciano de 80 o más Años , Cementos para Huesos , Femenino , Fracturas del Cuello Femoral/terapia , Humanos , Periodo Intraoperatorio , Masculino , Persona de Mediana Edad , Osteoartritis de la Cadera/cirugía , Estudios Prospectivos , Diseño de Prótesis
18.
Asian J Surg ; 44(1): 99-104, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-32312488

RESUMEN

BACKGROUND: Malposition of the femoral stem is a risk factor for dislocation after total hip arthroplasty (THA). Currently, two radiological methods are available for the measurement of stem anteversion. However, one method is not applicable in patients with a stiff hip, and the other one cannot differentiate the anteversion and retroversion of the stem. Therefore, we developed a method to measure the stem anteversion and assessed its reliability as well as validity. METHODS: Trans-lateral decubitus view of the proximal femur was taken with the patient in lateral decubitus position, the hip in extension and the knee in 90° flexion. Hip anteroposterior (AP) view, trans-lateral decubitus view and CT scan of the hip were taken in 36 patients, who underwent THA. Their mean age was 59.8 (27-84) years and the mean body mass index was 25.2 (18.8-30.9) kg/m2. The stem neck-femoral shaft angle was measured on hip AP view and the trans-lateral decubitus view. Then, the stem anteversion was calculated using the Ogata-Goldsand formula. We assessed the intra- and inter-observer reliabilities and evaluated the validity by comparing with the measurements on CT scan. RESULTS: The intra- and inter-observer reliabilities were 0.934 and 0.935, respectively. The calculated stem anteversion (23.72°±8.17°) correlated well with the stem anteversion on CT scan (23.91°±10.25°), especially when the radiological anteversion was <30° (correlation coefficient = 0.729, p = 0.001). CONCLUSION: We developed a reliable and valid method to measure stem anteversion using hip AP view and trans-lateral decubitus view of the femur. This method can replace conventional radiological methods.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Anteversión Ósea/diagnóstico por imagen , Fémur/diagnóstico por imagen , Cadera/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados
19.
Eur J Orthop Surg Traumatol ; 30(6): 1067-1074, 2020 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-32314066

RESUMEN

INTRODUCTION: Little is known about the association between well-fixed polished tapered cemented stems (PTCS) implanted by the line-to-line technique and changes of stem migration, or the change of functional anteversion of the femur after total hip arthroplasty (THA). MATERIALS AND METHODS: This retrospective study included 422 two-stage bilateral primary THAs performed using PTCS implanted by the line-to-line technique. CT scans were made on both the target side (first postoperative CT) and on the contralateral side (second postoperative CT) 1 week postoperatively. The mean follow-up was 7.8 months. CT data for each scan were transferred to 3D template software (Zed hip, Lexi, Japan). The postoperative changes of anatomical stem anteversion (ASA), functional femoral anteversion (FFA), and stem subsidence were evaluated. RESULTS: A total of 20 THAs with CT scans were available on 3D template software. The ASA and the FFA had migrated - 0.68° ± 0.62° and - 5.5° ± 9.7°, respectively, over the follow-up period. A significant positive correlation was observed between the change of subsidence and ASA (r2 = 0.34, p = 0.007), between the FFA on the second postoperative CT and ASA on the first postoperative CT (r2 = 0.26, p = 0.02) and between the FFA on the second postoperative CT and FFA on the first postoperative CT (r2 = 0.52, p = 0.0003). CONCLUSION: This study indicates that the change in axial rotation of a PTCS implanted by the line-to-line technique was less than that reported by other studies and the preoperative external rotation contracture was substantially improved after THA.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Procesamiento de Imagen Asistido por Computador/métodos , Posicionamiento del Paciente/métodos , Complicaciones Posoperatorias/prevención & control , Falla de Prótesis/etiología , Artroplastia de Reemplazo de Cadera/efectos adversos , Artroplastia de Reemplazo de Cadera/instrumentación , Artroplastia de Reemplazo de Cadera/métodos , Femenino , Fémur/diagnóstico por imagen , Fémur/fisiopatología , Prótesis de Cadera/efectos adversos , Humanos , Imagenología Tridimensional , Japón , Masculino , Persona de Mediana Edad , Cuidados Posoperatorios/métodos , Complicaciones Posoperatorias/diagnóstico , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/fisiopatología , Estudios Retrospectivos , Tomografía Computarizada por Rayos X/métodos
20.
Orthop Surg ; 12(2): 480-487, 2020 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-32202054

RESUMEN

OBJECTIVE: This study aimed to investigate the optimal level of femoral neck for measuring femoral anteversion to predict postoperative stem anteversion in Crowe type I developmental dysplasia of the hip. METHODS: This retrospective study analyzed 108 Crowe type I hips that underwent THA between January 2016 and December 2017, including 70 women and 19 men with a mean age of 63.08 ± 9.13 (range, 41-83) years. The single-wedge stem was used in 37 hips, the double-wedge stem was used in 71 hips. Computed tomography scans were performed pre- and post-operation. Femoral anteversion at six levels of the proximal femur were measured via preoperative two-dimensional computed tomography. Femoral anteversion at the level of the femoral neck osteotomy plane and postoperative stem anteversion were measured via three-dimensional reconstructed models. RESULTS: The mean follow-up period was 18.5 months (range, 12-27). The mean preoperative Harris Hip Score was 51.5 ± 8.7 and improved to 90.4 ± 7.8 (P < 0.001) by the last follow-up. There were no intraoperative fractures, and no infections occurred during the follow-up period. Two patients developed deep venous thrombosis. There was no sign of prosthetic loosening in all hips. No significant correlations were found between the height of the femoral neck osteotomy plane and postoperative stem anteversion (r = -0.119, P = 0.220). Femoral anteversion decreased gradually from 64.00° ± 10.51° at the center of lesser trochanter to 15.21° ± 13.31° at the head-neck junction, which was changed from more to less than stem anteversion (24.37° ± 13.86°). The femoral anteversion at femoral head-neck junction (15.21° ± 13.31°) was significantly less than postoperative stem anteversion (P = 0.000), with a difference of -9.16° ± 9.27°. The femoral anteversion at the level of the osteotomy plane (28.48° ± 15.34°) was significantly more than the postoperative stem anteversion (P = 0.000), with a difference of 4.11° ± 9.56°. Among all six levels and the level of osteotomy, femoral anteversion at the 10-mm level above the proximal base of lesser trochanter (22.65 ± 12.92) displayed the smallest difference (-1.72° ± 8.90°) and a good correlation (r = 0.764) with postoperative stem anteversion for all 108 hips, with a moderate correlation of 0.465 for single-wedge stem hips and an excellent correlation of 0.821 for double-wedge stem hips. CONCLUSION: For Crowe type I hips, femoral anteversion would be different if it was measured via different levels of the femoral neck. The 10-mm level above the proximal base of the lesser trochanter could be an optimum choice for measuring femoral anteversion to predict postoperative stem anteversion.


Asunto(s)
Artroplastia de Reemplazo de Cadera/métodos , Anteversión Ósea/diagnóstico por imagen , Anteversión Ósea/cirugía , Cuello Femoral/diagnóstico por imagen , Cuello Femoral/cirugía , Luxación Congénita de la Cadera/diagnóstico por imagen , Luxación Congénita de la Cadera/cirugía , Adulto , Anciano , Anciano de 80 o más Años , Evaluación de la Discapacidad , Femenino , Humanos , Imagenología Tridimensional , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Tomografía Computarizada por Rayos X
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA