RESUMEN
The manufacturing processes and design of metal and alloy products can be performed over a wide range of strain rates and temperatures. To design and optimize these processes using computational mechanics tools, the selection and calibration of the constitutive models is critical. In the case of hazardous and explosive impact loads, it is not always possible to test material properties. For this purpose, this paper assesses the efficiency and the accuracy of different architectures of ANNs for the identification of the Johnson-Cook material model parameters. The implemented computational tool of an ANN-based parameter identification strategy provides adequate results in a range of strain rates required for general manufacturing and product design applications. Four ANN architectures are studied to find the most suitable configuration for a reduced amount of experimental data, particularly for cases where high-impact testing is constrained. The different ANN structures are evaluated based on the model's predictive capability, revealing that the perceptron-based network of 66 inputs and one hidden layer of 30 neurons provides the highest prediction accuracy of the effective flow stress-strain behavior of Ti64 alloy and three virtual materials.
RESUMEN
Boron nitride nanotube peapods (BNNT-peapod) are composed of linear chains of C60molecules encapsulated inside BNNTs, they were first synthesized in 2003. In this work, we investigated the mechanical response and fracture dynamics of BNNT-peapods under ultrasonic velocity impacts (from 1 km s-1up to 6 km s-1) against a solid target. We carried out fully atomistic reactive molecular dynamics simulations using a reactive force field. We have considered the case of horizontal and vertical shootings. Depending on the velocity values, we observed tube bending, tube fracture, and C60ejection. Furthermore, the nanotube unzips for horizontal impacts at certain speeds, forming bi-layer nanoribbons 'incrusted' with C60molecules. The methodology used here is applicable to other nanostructures. We hope it motivates other theoretical investigations on the behavior of nanostructures at ultrasonic velocity impacts and aid in interpreting future experimental results. It should be stressed that similar experiments and simulations were carried out on carbon nanotubes trying to obtain nanodiamonds. The present study expands these investigations to include BNNT.
RESUMEN
SUMMARY: Biomechanical factors are important factors in inducing intervertebral disc degeneration, in this paper, the nonlinear viscoelastic mechanical properties of degenerated intervertebral discs were analyzed experimentally. Firstly, the loading and unloading curves of intervertebral discs before and after degeneration at different strain rates were compared to analyze the changes of their apparent viscoelastic mechanical properties; The internal stress/strain distribution of the disc before and after degeneration was then tested by combining digital image technology and fiber grating technology. The results show that the intervertebral disc is strain-rate- dependent whether before or after degeneration; The modulus of elasticity and peak stress of the degenerated disc are significantly reduced, with the modulus of elasticity dropping to 50 % of the normal value and the peak stress decreasing by about 55 %; Degeneration will not change the distribution of the overall internal displacement of the intervertebral disc, but has a greater impact on the superficial and middle AF; The stress in the center of the nucleus pulposus decreases, and the stress in the outer AF increases after degeneration. Degeneration has a great impact on the nonlinear viscoelastic mechanical properties of intervertebral disc, which has reference value for the mechanism, treatment and prevention of clinical degenerative diseases.
RESUMEN: Los factores biomecánicos son importantes en la inducción de la degeneración del disco intervertebral. En este estudio se analizaron experimentalmente las propiedades mecánicas viscoelásticas no lineales de los discos intervertebrales degenerados. En primer lugar se compararon las curvas de carga y descarga de los discos intervertebrales, antes y después de la degeneración, a diferentes velocidades de deformación para analizar los cambios aparentes de sus propiedades mecánicas viscoelásticas. La distribución interna de tensión/deformación del disco antes y después de la degeneración se probó luego combinando tecnología de imagen digital y tecnología de rejilla de fibra. Los resultados mostraron que el disco intervertebral depende de la velocidad de deformación antes o después de la degeneración; El módulo de elasticidad y la tensión máxima del disco degenerado se reducen significativamente, cayendo el módulo de elasticidad al 50 % del valor normal y la tensión máxima disminuyendo en aproximadamente un 55 %; La degeneración no cambiará la distribución del desplazamiento interno general del disco intervertebral, pero tiene un mayor impacto en la FA superficial y media; El estrés en el centro del núcleo pulposo disminuye y el estrés en el FA externo aumenta después de la degeneración. La degeneración tiene un gran impacto en las propiedades mecánicas viscoelásticas no lineales del disco intervertebral, que tiene valor de referencia para el mecanismo, tratamiento y prevención de enfermedades clínicas degenerativas.
Asunto(s)
Estrés Mecánico , Viscosidad , Dinámicas no Lineales , Degeneración del Disco Intervertebral , Fenómenos Biomecánicos , Módulo de Elasticidad , Modelos BiológicosRESUMEN
BACKGROUND: Left ventricle (LV) global longitudinal strain (GLS) at rest has shown prognostic value in patients (pts) with severe aortic stenosis (SAS). Contractile reserve (CR) during exercise stress echo (ESE) estimated via GLS (CR-GLS) could better stratify the asymptomatic patients who could benefit from early intervention. AIMS: To determine the long-term prognostic value of CR-GLS in patients with asymptomatic SAS with an ESE without inducible ischemia. Additionally, to compare the prognostic value of CR assessed via ejection fraction (CR-EF) and CR-GLS. METHODS: In a prospective, single-center, observational study between 2013 and 2019, 101 pts with asymptomatic SAS and preserved left ventricular ejection fraction (LVEF) > 55% were enrolled. CR was considered present with an exercise-rest increase in LVEF (Simpson's rule) ≥ 5 points and > 2 absolute points in GLS. Patients were assigned to 2 groups (G): G1: 56 patients with CR-GLS present; and G2: 45 patients CR-GLS absent. All patients were followed up. RESULTS: G2 Patients were older, with lower exercise capability, less aortic valve area (AVA), a higher peak aortic gradient, and less LVEF (71.5% ± 5.9 vs. 66.8% ± 7.9; p = 0.002) and GLS (%) at exercise (G1: -22.2 ± 2.8 vs. G2: -18.45 ± 2.4; p = 0.001). During mean follow-up of 46.6 ± 3.4 months, events occurred in 45 pts., with higher incidence in G2 (G2 = 57.8% vs. G1 = 42.2%, p < 0.01). At Cox regression analysis, CR-GLS was an independent predictor of major cardiovascular events (HR: 1.98, 95% CI 1.09-3.58, p = 0.025). Event-free survival was lower for patients with CR-GLS absent (log rank test p = 0.022). CR-EF was not outcome predictive (log rank test p 0.095). CONCLUSIONS: In patients with asymptomatic SAS, the absence of CR-GLS during ESE is associated with worse prognosis. Additionally, CR-GLS was a better predictor of events than CR-EF.
RESUMEN
An electrochemical study of stress corrosion cracking (SCC) of API X70 steel in a simulated soil solution at different pH values (3, 8 and 10) was carried out. The stress conditions were implemented by slow strain rate stress test (SSRT) and the SCC process was simultaneously monitored by electrochemical impedance spectroscopy (EIS). Fracture surface analysis and corrosion product analysis were performed by scanning electron microscopy (SEM) and X-ray diffraction (XRD), respectively. The results show that the susceptibility to SCC was higher as the pH decreases. In the acid solution, hydrogen evolution can occur by H+ and H2CO3 reduction, and more atomic hydrogen can diffuse into the steel, producing embrittlement. EIS results indicated that the anodic dissolution contributed to SCC process by reducing the charge transfer resistances during the SSRT test. While SEM micrographs shown a general corrosion morphology on the longitudinal surface of samples. At higher pH (pH 8 and pH 10), the SCC susceptibility was lower, which it is attributed to the presence of corrosion products film, which could have limited the process. Using the angle phase (φ) value it was determined that the cracking process started at a point close to the yield strength (YS).
RESUMEN
PURPOSE: This paper presents CardIAc, an open-source application designed as an alternative to commercial software for left ventricle myocardial strain quantification in short-axis cardiac magnetic resonance images. The aim is to provide a useful extension for myocardial strain analysis that can be easily adapted to incorporate different strategies of motion tracking to improve the strain accuracy. In this way, users with programming skills can easily modify the code and adjust the program's performance according to their own scientific or clinical requirements. The software is intended for research and clinical use is not advised. METHODS: CardIAc was developed as a 3D Slicer extension for an easy installation and usability. The main contribution of this article is to provide a general workflow, going from data and segmentation loading, 3D heart modeling, analysis and several options for visualization of the myocardial strain. RESULTS: CardIAc strain feature was evaluated on a public dataset (Cardiac Motion Analysis Challenge-STACOM 2011) of 15 volunteers, and a synthetic one generated from this real dataset. Results on the real dataset show that cardIAc achieves suitable accuracy for myocardial motion estimation with a median error of 3.66 mm. In particular, global strain curves show strong correlation with the bibliography for healthy patients and similar approaches. On the other hand, results on the synthetic dataset show a mean global error of 4.07%, 7.76% and 8.18% for circumferential, radial and longitudinal strain. CONCLUSION: This paper introduces a new open-source application for strain analysis distributed under a BSD-style open-source license. Results demonstrate the capability and merits of the proposed application for strain analysis.
Asunto(s)
Corazón/diagnóstico por imagen , Imagen por Resonancia Cinemagnética/métodos , Miocardio , Programas Informáticos , Función Ventricular Izquierda/fisiología , Ventrículos Cardíacos/diagnóstico por imagen , Humanos , Imagen por Resonancia Magnética , Modelos Cardiovasculares , Reproducibilidad de los ResultadosRESUMEN
Background: Non-specific phenotype feline cardiomyopathy (CFNE) is one that does not fit properly in the other categories, and it is necessary to describe in detail the morphology and cardiac function. The causes of CFNE is not very clear, and it may be due to congenital or acquired disease, or also to primary or secondary myocardial dysfunction associated with other conditions. In symptomatic cases, the clinical signs observed are compatible with left congestive heart failure (ICCE). This study reports a CFNE case in an asymptomatic cat, in order to demonstrate the importance of echocardiographic examination in the early diagnosis of the disease. Case: A 6.5-year-old non-neutered crossbred cat weighing 3.1 kg was seen at the institutions veterinary hospital for routine cardiac evaluation. No clinical signs were reported in the history. On physical examination, the animal presented calm behavior, body score 5/9, heart rate 200 bpm, systolic blood pressure of 102 mmHg, respiratory rate 64 mrp, and other normal parameters. CBC and urinalysis laboratory tests were requested, which were unchanged. The electrocardiogram showed normal patterns. In the conventional echocardiographic examination, a significant increase in the left atrium (LA) was observed, and the LA/Ao ratio was 2.05 and the diastolic function was abnormal. There was no presence of concentric hypertrophy of the left ventricle (LV), the thickness of the ventricular wall measured at different points, in the two-dimensional mode and the M mode, was less than 5 millimeters. Other parameters of conventional echocardiography were within the normal range. Through these echocardiographic findings, the suggestive diagnosis was non-specific phenotype cardiomyopathy, with a significant increase in LA. For the...(AU)
Asunto(s)
Animales , Femenino , Gatos , Cardiomiopatías/diagnóstico por imagen , Cardiomiopatías/veterinaria , Disfunción Ventricular Izquierda/diagnóstico por imagen , Disfunción Ventricular Izquierda/veterinaria , Ecocardiografía/veterinariaRESUMEN
BACKGROUND: Strain Rate Imaging (SRI) is one of the most used techniques to study left atrial (LA) and diastolic function. Its availability in low-income countries is diminished since it requires additional expensive software, among other limitations. In contrast, Tissue Doppler Imaging (TDI) is widely available and easy to use. We hypothesize TDI could detect changes in LA and diastolic function associated with age similarly to SRI. The aim of this study is to evaluate the effects of age on LA and diastolic function assessed by LA lateral wall TDI online by spectral pulse, and to compare them with age-related variations of LA SRI and other parameters of diastolic function in a population of healthy adults. MATERIALS AND METHODS: Ninety-one healthy adults were prospectively evaluated. In apical four - chamber view the LA lateral wall was divided in three portions. Peak velocities of basal and mid portions were measured with TDI online by spectral pulse and with SRI by speckle tracking. A first positive wave (S'la and SRS) and two negative waves (E'la and SRE, and A'la and SRA respectively) were obtained. E'la/A'la ratio and SRE/SRA ratio were analyzed. The distribution of the variables by age subgroups was described and analyzed. Correlation analyses were performed. RESULTS: The median age was 42 years old and 54.9% were female. E'la/A'la showed a negative good correlation with age. E'la/A'la and SRE/SRA ratios changed from > 1 to < 1 in the age group of 41-50 years old, while this occurred in the group of 51-60 years old for the E/A ratio. Lateral and septal mitral annulus E´ showed decrease with age and prolongation of E-wave deceleration time was observed in the age group over 61 years old. CONCLUSION: Normal valuesââ according to age group of TDI of the LA lateral wall were obtained. Age-related changes in LA and diastolic function could be detected as early with TDI as with SRI. Future studies are required to explore if this method could be used to address in part LA or diastolic function in other populations with established cardiovascular disease or at risk of presenting it, which could be useful in low-income settings, where SRI is not available.
Asunto(s)
Ecocardiografía Doppler en Color , Voluntarios Sanos , Atrios Cardíacos/diagnóstico por imagen , Adulto , Factores de Edad , Diástole , Femenino , Humanos , Interpretación de Imagen Asistida por Computador , Masculino , Estudios ProspectivosRESUMEN
O desenvolvimento de novas ferramentas, como a ecocardiografia bidimensional feature tracking (2D-FTI), permite diagnosticar, de forma precoce, se há disfunção miocárdica em doenças cardíacas, inclusive as congênitas. O defeito septal ventricular (DSV) é a alteração congênita mais observada em felinos, no entanto pouco se sabe sobre a disfunção cardíaca nessa cardiopatia, especialmente em animais assintomáticos. O objetivo deste estudo foi avaliar, por meio do 2D-FTI, a deformação miocárdica ventricular esquerda pela mensuração dos índices ecocardiográficos strain (St) e strain rate (StR) radial, circunferencial e longitudinal, em gatos saudáveis e com DSV. Foram avaliados 12 gatos saudáveis e seis gatos com DSV para obtenção de St e StR em diversos segmentos miocárdicos. No sentido longitudinal, houve diferença estatística (P<0,05) para os segmentos septal basal, mediano e apical epicárdicos (P=0,0017; P<0,0001; P=0,0288), lateral mediano epicárdico (P=0,0327), septal mediano endocárdico (P=0,0035), lateral mediano endocárdico (P=0,0461), St epicárdico (P=0,0250) e St global (P=0,0382). Também houve diferença no segmento lateral mediano circunferencial endocárdico (P=0,0248), lateral mediano radial (St: P=0,0409; StR: P=0,0166) e posterior mediano radial (P=0,0369). O estudo evidenciou que, mesmo em animais assintomáticos com DSV, há redução na deformação miocárdica ventricular principalmente no sentido longitudinal, demonstrando maior vulnerabilidade dessas fibras.(AU)
The development of new tools, such as two-dimensional feature tracking (2D-FTI), allows early diagnosis of myocardial dysfunction in heart diseases including congenital heart disease. The ventricular septal defect (VSD) is the most frequently observed congenital abnormality in cats, however, little is known about cardiac dysfunction, especially in asymptomatic animals. The objective of this study was to evaluate the left ventricular myocardial deformation through 2D-FTI by the measurement of the radial, circumferential and longitudinal echocardiographic strain (St) and strain rate (StR) indices. Twelve healthy cats and six cats with VSD were evaluated to obtain St and StR in several myocardial segments. In the longitudinal direction, there was a statistical difference (P<0.05) for the epimyocardial basal septal, mid-septal, apical septal (P=0.0017; P<0.0001; P=0.0288), epimyocardial mid-lateral (P=0.0327), endomyocardial mid-septal (P=0.0035), endomyocardial mid-lateral (P=0.0461), St epimyocardial (P=0.0250) and St global (P=0.0382). There was also difference in the circumferential endomyocardial mid-lateral segment (P=0.0248), radial mid-lateral (St: P=0.0409; StR: P=0.0166) and radial mid-posterior (P=0.0369). The study showed that even in asymptomatic animals with VSD there is a reduction in ventricular myocardial deformation mainly in the longitudinal direction, demonstrating the fragility of these fibers.(AU)
Asunto(s)
Animales , Gatos , Cardiopatías Congénitas/veterinaria , Defectos del Tabique Interventricular/veterinaria , Defectos del Tabique Interventricular/diagnóstico por imagen , Ecocardiografía/veterinariaRESUMEN
O desenvolvimento de novas ferramentas, como a ecocardiografia bidimensional feature tracking (2D-FTI), permite diagnosticar, de forma precoce, se há disfunção miocárdica em doenças cardíacas, inclusive as congênitas. O defeito septal ventricular (DSV) é a alteração congênita mais observada em felinos, no entanto pouco se sabe sobre a disfunção cardíaca nessa cardiopatia, especialmente em animais assintomáticos. O objetivo deste estudo foi avaliar, por meio do 2D-FTI, a deformação miocárdica ventricular esquerda pela mensuração dos índices ecocardiográficos strain (St) e strain rate (StR) radial, circunferencial e longitudinal, em gatos saudáveis e com DSV. Foram avaliados 12 gatos saudáveis e seis gatos com DSV para obtenção de St e StR em diversos segmentos miocárdicos. No sentido longitudinal, houve diferença estatística (P<0,05) para os segmentos septal basal, mediano e apical epicárdicos (P=0,0017; P<0,0001; P=0,0288), lateral mediano epicárdico (P=0,0327), septal mediano endocárdico (P=0,0035), lateral mediano endocárdico (P=0,0461), St epicárdico (P=0,0250) e St global (P=0,0382). Também houve diferença no segmento lateral mediano circunferencial endocárdico (P=0,0248), lateral mediano radial (St: P=0,0409; StR: P=0,0166) e posterior mediano radial (P=0,0369). O estudo evidenciou que, mesmo em animais assintomáticos com DSV, há redução na deformação miocárdica ventricular principalmente no sentido longitudinal, demonstrando maior vulnerabilidade dessas fibras.(AU)
The development of new tools, such as two-dimensional feature tracking (2D-FTI), allows early diagnosis of myocardial dysfunction in heart diseases including congenital heart disease. The ventricular septal defect (VSD) is the most frequently observed congenital abnormality in cats, however, little is known about cardiac dysfunction, especially in asymptomatic animals. The objective of this study was to evaluate the left ventricular myocardial deformation through 2D-FTI by the measurement of the radial, circumferential and longitudinal echocardiographic strain (St) and strain rate (StR) indices. Twelve healthy cats and six cats with VSD were evaluated to obtain St and StR in several myocardial segments. In the longitudinal direction, there was a statistical difference (P<0.05) for the epimyocardial basal septal, mid-septal, apical septal (P=0.0017; P<0.0001; P=0.0288), epimyocardial mid-lateral (P=0.0327), endomyocardial mid-septal (P=0.0035), endomyocardial mid-lateral (P=0.0461), St epimyocardial (P=0.0250) and St global (P=0.0382). There was also difference in the circumferential endomyocardial mid-lateral segment (P=0.0248), radial mid-lateral (St: P=0.0409; StR: P=0.0166) and radial mid-posterior (P=0.0369). The study showed that even in asymptomatic animals with VSD there is a reduction in ventricular myocardial deformation mainly in the longitudinal direction, demonstrating the fragility of these fibers.(AU)
Asunto(s)
Animales , Gatos , Cardiopatías Congénitas/veterinaria , Defectos del Tabique Interventricular/veterinaria , Defectos del Tabique Interventricular/diagnóstico por imagen , Ecocardiografía/veterinariaRESUMEN
The present study evaluated the volume and function of the left atrium by two-dimensional echocardiographic feature-tracking imaging (2D-FTI) and Simpson's monoplanar modeling in dogs with asymptomatic degenerative mitral valve disease (DMVD). The study consisted of 80 dogs that were divided into the following three groups: Group 1, 21 dogs (A); Group 2, 30 dogs (B1) and Group 3, 29 dogs (B2). The variable strain (contraction phase) was significantly lower in Group 3 than in Group 1 (12.92±4.54 x 16.69±5.74, p=0.014), and significant differences in the contraction strain index (CSI) were observed between all of the groups that were evaluated (1 = 46.82±8.10, 2 = 39.88±8.03, 3 = 35.25±5.64, p<0.0001). The atrial diastolic volume index (AdVi) that was measured by 2D-FTI was significantly higher in Group 3 than in Group 1 (1.31±0.95 x 0.96±0.31, p=0.038), and the atrial cardiac index (ACI) was also higher in Group 3 than in Group 1 (102.38±80.18 x 78.19±33.38, p=0.030). Atrial function was assessed by Simpson's monoplanar method, which demonstrated an increase in the left atrial systolic volume, while the contractile function decreased with an increasing disease severity (Group 1 0.21±0.06; Group 2 0.25±0.06; Group 3 0.32±0.08, p<0.0001). The intraobserver and interobserver assessments showed low to moderate variability; most of the values for the coefficient of variation for the variables that were analysed with each method were below 25%. Thus, DMVD was determined to cause an alteration in atrial function, especially in the contraction phase, and even in asymptomatic animals, and the methods of 2D-FTI echocardiography and Simpson's monoplanar evaluation are sensitive and early methods for the detection of left atrial dysfunction.(AU)
O presente estudo avaliou o volume e a função atrial esquerda obtidos por meio da ecocardiografia bidimensional feature tracking (2D-FTI) e pelo método monoplanar de Simpson em cães saudáveis e cães com DMVD assintomáticos. Foram avaliados 80 cães distribuídos em três grupos: Grupo 1, 21 cães (classe A); Grupo 2, 30 cães (classe B1) e Grupo 3, 29 cães (classe B2). A variável strain (fase de contração) foi significativamente menor no Grupo 3 que no Grupo 1 (12,92±4,54 x 16,69±5,74, p=0,014) e para a variável índice de strain de contração (CSI), houve diferença estatística entre todos os grupos avaliados (1 = 46,82±8,10; 2 = 39,88±8,03; 3 = 35,25±5,64, p<0,0001). O índice de volume diastólico atrial (iVdA) mensurado por meio do 2D-FTI foi significativamente maior no Grupo 3 que no Grupo 1 (1,31±0,95 x 0,96±0,31, p=0,038), assim como para o índice cardíaco atrial (iCA) também foi maior no Grupo 3 (102,38±80,18 x 78,19±33,38, p=0,030). A função atrial avaliada pelo método monoplanar de Simpson demonstrou um aumento do volume atrial esquerdo e do volume sistólico do átrio esquerdo, enquanto que a função contrátil diminuiu com o aumento da gravidade da doença (Grupo 1 0,21±0,06; Grupo 2 0,25±0,06; Grupo 3 0,32±0,08; p<0,0001). A avaliação intraobservador e interobservador, demonstrou variabilidade baixa a moderada, uma vez que a maioria dos valores de coeficiente de variação se concentraram abaixo de 25% para as variáveis analisadas em ambos os métodos. Dessa forma, conclui-se que a DMVD causa alteração na função atrial, principalmente na fase de contração, mesmo em animais assintomáticos e que a ecocardiografia 2D-FTI e o método monoplanar de Simpson são métodos sensíveis e precoces na detecção da disfunção atrial esquerda.(AU)
Asunto(s)
Animales , Perros , Función del Atrio Izquierdo , Técnicas Electrofisiológicas Cardíacas/veterinaria , Enfermedades de las Válvulas Cardíacas/veterinaria , Válvula Mitral/diagnóstico por imagen , Ecocardiografía/métodos , Ecocardiografía/veterinariaRESUMEN
The present study evaluated the volume and function of the left atrium by two-dimensional echocardiographic feature-tracking imaging (2D-FTI) and Simpson's monoplanar modeling in dogs with asymptomatic degenerative mitral valve disease (DMVD). The study consisted of 80 dogs that were divided into the following three groups: Group 1, 21 dogs (A); Group 2, 30 dogs (B1) and Group 3, 29 dogs (B2). The variable strain (contraction phase) was significantly lower in Group 3 than in Group 1 (12.92±4.54 x 16.69±5.74, p=0.014), and significant differences in the contraction strain index (CSI) were observed between all of the groups that were evaluated (1 = 46.82±8.10, 2 = 39.88±8.03, 3 = 35.25±5.64, p<0.0001). The atrial diastolic volume index (AdVi) that was measured by 2D-FTI was significantly higher in Group 3 than in Group 1 (1.31±0.95 x 0.96±0.31, p=0.038), and the atrial cardiac index (ACI) was also higher in Group 3 than in Group 1 (102.38±80.18 x 78.19±33.38, p=0.030). Atrial function was assessed by Simpson's monoplanar method, which demonstrated an increase in the left atrial systolic volume, while the contractile function decreased with an increasing disease severity (Group 1 0.21±0.06; Group 2 0.25±0.06; Group 3 0.32±0.08, p<0.0001). The intraobserver and interobserver assessments showed low to moderate variability; most of the values for the coefficient of variation for the variables that were analysed with each method were below 25%. Thus, DMVD was determined to cause an alteration in atrial function, especially in the contraction phase, and even in asymptomatic animals, and the methods of 2D-FTI echocardiography and Simpson's monoplanar evaluation are sensitive and early methods for the detection of left atrial dysfunction.(AU)
O presente estudo avaliou o volume e a função atrial esquerda obtidos por meio da ecocardiografia bidimensional feature tracking (2D-FTI) e pelo método monoplanar de Simpson em cães saudáveis e cães com DMVD assintomáticos. Foram avaliados 80 cães distribuídos em três grupos: Grupo 1, 21 cães (classe A); Grupo 2, 30 cães (classe B1) e Grupo 3, 29 cães (classe B2). A variável strain (fase de contração) foi significativamente menor no Grupo 3 que no Grupo 1 (12,92±4,54 x 16,69±5,74, p=0,014) e para a variável índice de strain de contração (CSI), houve diferença estatística entre todos os grupos avaliados (1 = 46,82±8,10; 2 = 39,88±8,03; 3 = 35,25±5,64, p<0,0001). O índice de volume diastólico atrial (iVdA) mensurado por meio do 2D-FTI foi significativamente maior no Grupo 3 que no Grupo 1 (1,31±0,95 x 0,96±0,31, p=0,038), assim como para o índice cardíaco atrial (iCA) também foi maior no Grupo 3 (102,38±80,18 x 78,19±33,38, p=0,030). A função atrial avaliada pelo método monoplanar de Simpson demonstrou um aumento do volume atrial esquerdo e do volume sistólico do átrio esquerdo, enquanto que a função contrátil diminuiu com o aumento da gravidade da doença (Grupo 1 0,21±0,06; Grupo 2 0,25±0,06; Grupo 3 0,32±0,08; p<0,0001). A avaliação intraobservador e interobservador, demonstrou variabilidade baixa a moderada, uma vez que a maioria dos valores de coeficiente de variação se concentraram abaixo de 25% para as variáveis analisadas em ambos os métodos. Dessa forma, conclui-se que a DMVD causa alteração na função atrial, principalmente na fase de contração, mesmo em animais assintomáticos e que a ecocardiografia 2D-FTI e o método monoplanar de Simpson são métodos sensíveis e precoces na detecção da disfunção atrial esquerda.(AU)
Asunto(s)
Animales , Perros , Función del Atrio Izquierdo , Técnicas Electrofisiológicas Cardíacas/veterinaria , Enfermedades de las Válvulas Cardíacas/veterinaria , Válvula Mitral/diagnóstico por imagen , Ecocardiografía/métodos , Ecocardiografía/veterinariaRESUMEN
Sheets of 5754-aluminum alloy processed by a modified repetitive corrugation and straightening (RCS) process were tested in order to measure their formability. For this purpose, forming limit curves were derived. They showed that the material forming capacity decreased after being processed by RCS. However, they kept good formability in the initial stages of the RCS process. The formability study was complemented with microstructural analysis (derivation of texture) and mechanical tests to obtain the strain-rate sensitivity. The texture analysis was done by employing X-ray diffraction, obtaining pole figures, and the orientation distribution function. It was noticed that the initial texture was conserved after successive RCS passes, but the intensity dropped. RCS process did not induce ß-fiber, contrary to common deformation process. The strain-rate sensitivity coefficient was measured through tensile tests at different temperatures and strain rates; the coefficient of the samples processed after one and two passes were still relatively high, indicating the capacity to delay necking, in agreement with the good formability observed in the initial passes of the RCS process.
RESUMEN
Background: Non-specific phenotype feline cardiomyopathy (CFNE) is one that does not fit properly in the other categories, and it is necessary to describe in detail the morphology and cardiac function. The causes of CFNE is not very clear, and it may be due to congenital or acquired disease, or also to primary or secondary myocardial dysfunction associated with other conditions. In symptomatic cases, the clinical signs observed are compatible with left congestive heart failure (ICCE). This study reports a CFNE case in an asymptomatic cat, in order to demonstrate the importance of echocardiographic examination in the early diagnosis of the disease. Case: A 6.5-year-old non-neutered crossbred cat weighing 3.1 kg was seen at the institutions veterinary hospital for routine cardiac evaluation. No clinical signs were reported in the history. On physical examination, the animal presented calm behavior, body score 5/9, heart rate 200 bpm, systolic blood pressure of 102 mmHg, respiratory rate 64 mrp, and other normal parameters. CBC and urinalysis laboratory tests were requested, which were unchanged. The electrocardiogram showed normal patterns. In the conventional echocardiographic examination, a significant increase in the left atrium (LA) was observed, and the LA/Ao ratio was 2.05 and the diastolic function was abnormal. There was no presence of concentric hypertrophy of the left ventricle (LV), the thickness of the ventricular wall measured at different points, in the two-dimensional mode and the M mode, was less than 5 millimeters. Other parameters of conventional echocardiography were within the normal range. Through these echocardiographic findings, the suggestive diagnosis was non-specific phenotype cardiomyopathy, with a significant increase in LA. For the...
Asunto(s)
Femenino , Animales , Gatos , Cardiomiopatías/diagnóstico por imagen , Cardiomiopatías/veterinaria , Disfunción Ventricular Izquierda/diagnóstico por imagen , Disfunción Ventricular Izquierda/veterinaria , Ecocardiografía/veterinariaRESUMEN
Objective To analyze the behavior of fetal longitudinal myocardial fibers assessed by speckle tracking (STE) after fetal viability. Methods A cross-sectional study was performed in 156 women with normal singleton pregnancies from 22 to 31 weeks of gestation. Strain (S) and strain rate (SR) values were measured in both ventricles during the fetal cardiac cycle. The population was divided into five gestational age groups based on 2-week intervals. The correlations of maternal variables with the S and SR variables and intra-observer analysis were performed. Results There was a significant difference in the S and SR values of the left ventricle (LV) among the gestational age groups (P = 0.007). Significantly higher S and SR values were observed in early age groups demonstrating reductions in LV S and SR values at 26 weeks, followed by stabilization. For the right ventricle (RV), there was no significant difference between gestational age groups. Significant intra-observer agreement was observed for S values of the RV (P = 0.008) and LV (P = 0.0004) and SR values of the RV (P = 0.0001) and LV (P = 0.015). Conclusion Decreases in the S and SR values of the LV occurred after 26 weeks, followed by stabilization. No significant difference was observed in the S or SR value of the RV among the gestational age groups, and no significant association of any maternal variable evaluated with S and SR values was observed. Significant intra-observer agreement was obtained among the results.
Asunto(s)
Corazón Fetal/diagnóstico por imagen , Ultrasonografía Prenatal/métodos , Adulto , Estudios Transversales , Femenino , Corazón Fetal/fisiología , Humanos , Embarazo , Valores de Referencia , Función Ventricular Izquierda , Función Ventricular Derecha , Adulto JovenRESUMEN
ABSTRACT: The present study evaluated the volume and function of the left atrium by two-dimensional echocardiographic feature-tracking imaging (2D-FTI) and Simpsons monoplanar modeling in dogs with asymptomatic degenerative mitral valve disease (DMVD). The study consisted of 80 dogs that were divided into the following three groups: Group 1, 21 dogs (A); Group 2, 30 dogs (B1) and Group 3, 29 dogs (B2). The variable strain (contraction phase) was significantly lower in Group 3 than in Group 1 (12.92±4.54 x 16.69±5.74, p=0.014), and significant differences in the contraction strain index (CSI) were observed between all of the groups that were evaluated (1 = 46.82±8.10, 2 = 39.88±8.03, 3 = 35.25±5.64, p 0.0001). The atrial diastolic volume index (AdVi) that was measured by 2D-FTI was significantly higher in Group 3 than in Group 1 (1.31±0.95 x 0.96±0.31, p=0.038), and the atrial cardiac index (ACI) was also higher in Group 3 than in Group 1 (102.38±80.18 x 78.19±33.38, p=0.030). Atrial function was assessed by Simpsons monoplanar method, which demonstrated an increase in the left atrial systolic volume, while the contractile function decreased with an increasing disease severity (Group 1 0.21±0.06; Group 2 0.25±0.06; Group 3 0.32±0.08, p 0.0001). The intraobserver and interobserver assessments showed low to moderate variability; most of the values for the coefficient of variation for the variables that were analysed with each method were below 25%. Thus, DMVD was determined to cause an alteration in atrial function, especially in the contraction phase, and even in asymptomatic animals, and the methods of 2D-FTI echocardiography and Simpsons monoplanar evaluation are sensitive and early methods for the detection of left atrial dysfunction.
RESUMO: O presente estudo avaliou o volume e a função atrial esquerda obtidos por meio da ecocardiografia bidimensional feature tracking (2D-FTI) e pelo método monoplanar de Simpson em cães saudáveis e cães com DMVD assintomáticos. Foram avaliados 80 cães distribuídos em três grupos: Grupo 1, 21 cães (classe A); Grupo 2, 30 cães (classe B1) e Grupo 3, 29 cães (classe B2). A variável strain (fase de contração) foi significativamente menor no Grupo 3 que no Grupo 1 (12,92±4,54 x 16,69±5,74, p=0,014) e para a variável índice de strain de contração (CSI), houve diferença estatística entre todos os grupos avaliados (1 = 46,82±8,10; 2 = 39,88±8,03; 3 = 35,25±5,64, p 0,0001). O índice de volume diastólico atrial (iVdA) mensurado por meio do 2D-FTI foi significativamente maior no Grupo 3 que no Grupo 1 (1,31±0,95 x 0,96±0,31, p=0,038), assim como para o índice cardíaco atrial (iCA) também foi maior no Grupo 3 (102,38±80,18 x 78,19±33,38, p=0,030). A função atrial avaliada pelo método monoplanar de Simpson demonstrou um aumento do volume atrial esquerdo e do volume sistólico do átrio esquerdo, enquanto que a função contrátil diminuiu com o aumento da gravidade da doença (Grupo 1 0,21±0,06; Grupo 2 0,25±0,06; Grupo 3 0,32±0,08; p 0,0001). A avaliação intraobservador e interobservador, demonstrou variabilidade baixa a moderada, uma vez que a maioria dos valores de coeficiente de variação se concentraram abaixo de 25% para as variáveis analisadas em ambos os métodos. Dessa forma, conclui-se que a DMVD causa alteração na função atrial, principalmente na fase de contração, mesmo em animais assintomáticos e que a ecocardiografia 2D-FTI e o método monoplanar de Simpson são métodos sensíveis e precoces na detecção da disfunção atrial esquerda.
RESUMEN
BACKGROUND: A weak correlation has been reported between left ventricular filling pressures and the traditional echocardiographic tools for the evaluation of diastolic function in patients with coronary artery disease (CAD) and preserved left ventricular ejection fraction (LVEF). On the other hand, studies that compared invasive measurements with speckle tracking echocardiography have shown promising results, but they were not exclusively targeted on this specific population. METHODS AND RESULTS: Immediately before the left heart catheterization, a comprehensive two-dimensional Doppler echocardiography and speckle tracking analysis was prospectively performed in outpatients referred for coronary angiography. Left ventricular end-diastolic pressure (LVEDP) was measured before any contrast exposure. Eighty-one patients with coronary artery disease were studied, and the group with high LVEDP (n = 40) showed increased left atrial volume index (22 ± 6 mL/m2 vs 26 ± 8.26 mL/m2 , P = 0.04), E-wave velocity (65 ± 15 cm/s vs 78 ± 20 cm/s, P = 0.02), E/e` (average) ratio (8.14 ± 2.0 vs 11.54 ± 2.7, P = 0.03), and E/global circumferential strain rate E peak ratio (E/GCSRE ) (39 cm vs 46 cm, P < 0.01). There was a positive correlation between LVEDP and E/e` (ρ = 0.56; P = 0.03), and between LVEDP and E/GCSRE ratio (ρ = 0.43; P < 0.01). The area under the receiver operating characteristics (ROC) curve was 0.83 and 0.73, respectively (P < 0.05). E/e` and E/GCSRE were both independent predictors of elevated LVEDP (P < 0.05), with a higher C-statistic for the model including E/e` (0.89 vs 0.85). CONCLUSION: The E/e` ratio was able to identify elevated LVEDP in CAD patients with preserved LVEF with more accuracy than the E/GCSRE ratio.
Asunto(s)
Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/fisiopatología , Ecocardiografía Doppler/métodos , Disfunción Ventricular Izquierda/diagnóstico por imagen , Disfunción Ventricular Izquierda/fisiopatología , Cateterismo Cardíaco , Angiografía Coronaria , Diástole , Femenino , Hemodinámica , Humanos , Interpretación de Imagen Asistida por Computador , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Sensibilidad y Especificidad , Volumen SistólicoRESUMEN
BACKGROUND: Fabry disease (FD) and hypertrophic cardiomyopathy (HCM) are two diseases with a different pathophysiology, both cause left ventricular hypertrophy (LVH) and myocardial fibrosis. Although remodeling and systolic dysfunction of the left atrium (LA) are associated with atrial fibrillation and stroke in HCM, changes in the size and function of the LA have not been well studied in FD with LVH. METHODS: The following groups were studied prospectively, and their respective findings compared: 19 patients with non-obstructive HCM (Group I), 20 patients with a diagnosis of Fabry cardiomyopathy (Group II), and 20 normal subjects matched for sex and age (Group III). Left ventricular mass index was measured using Devereux' formula, left atrial volume with Simpson's biplane method and left atrial mechanical function, including strain and strain rate, was measured using the speckle tracking technique. Strain and strain rate of the reservoir were measured during the three phases: reservoir (SR S), passive conduit (SR E) and atrial contraction (SR A). RESULTS: Patients with HCM had a larger left atrial volume than patients with FD (48.16 ± 14.3 mL/m2 vs 38.9 ± 14.9 mL/m2 respectively, P < .001), but in both disorders there was a severe decrease in left atrial function: reservoir strain in the apical four-chamber view: 17.47% in HCM vs 22.5% in FD, P = .24), strain rate in the apical chamber view: SR A: -0.80/seconds in HCM vs -1.04/seconds in FD (P = .88), SR S: 0.69/seconds in HCM vs 0.93 in FD (P = .12), SR E: -0.80 seconds in HCM vs -0.97/seconds in FD (P = .18). CONCLUSIONS: In this echocardiographic study we used speckle tracking to assess left atrial mechanical function and showed that FD is associated to an atrial cardiomyopathy, affecting the three phasic functions of the LA. Although in patients with HCM left atrial volume is larger than in patients with FD, both disorders exhibit severe decrease in left atrial function. These findings should be considered, given the potentially serious complications that can occur with the two diseases.
Asunto(s)
Función del Atrio Izquierdo/fisiología , Cardiomiopatía Hipertrófica/complicaciones , Ecocardiografía Doppler en Color/métodos , Enfermedad de Fabry/complicaciones , Atrios Cardíacos/diagnóstico por imagen , Hipertrofia Ventricular Izquierda/complicaciones , Función Ventricular Izquierda/fisiología , Adulto , Cardiomiopatía Hipertrófica/diagnóstico , Cardiomiopatía Hipertrófica/fisiopatología , Enfermedad de Fabry/diagnóstico , Femenino , Atrios Cardíacos/fisiopatología , Humanos , Hipertrofia Ventricular Izquierda/diagnóstico , Hipertrofia Ventricular Izquierda/fisiopatología , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Reproducibilidad de los ResultadosRESUMEN
O objetivo deste estudo prospectivo foi analisar a função do ventrículo esquerdo de cadelas que apresentavam sepse ou não e diagnosticar a depressão miocárdica de forma precoce, por meio do feature tracking imaging bidimensional (FTI-2D).Vinte e nove cadelas diagnosticadas com piometra, patologia usada como modelo experimental para sepse, foram avaliadas. Os animais foram submetidos ao exame ecocardiográfico convencional e ao FTI-2D e divididos em três grupos: grupo I (controle), grupo II (piometra sepse) e grupo III (piometra não sepse). Em relação aos parâmetros da ecocardiografia convencional, não houve diferença estatística entre os grupos avaliados. Quanto ao strain radial, os grupos II e III apresentaram função ventricular inferior no momento do diagnóstico (22,805,80 grupo I; 18,455,96 grupo II; 18,719,45 grupo III; P=0,032) e o grupo III manteve essa redução no retorno. Já no strain rate radial, apenas o grupo III obteve função ventricular inferior no momento do diagnóstico (1,900,57 grupo I; 1,910,70 grupo II, 1,570,53 grupo III; P=0,021). Para o strain longitudinal, observou-se função ventricular mais baixa nos grupos II e III no momento do diagnóstico (11,043,38 grupo I; 8,593,97 grupo II; 8,211,99; P=0,048) e após 10 dias de pós-cirúrgico (11,043,38 grupo I; 9,002,16 grupo II; 8,122,27 grupo III; p=0,048). O FTI-2D foi capaz de detectar alterações precoces da função ventricular esquerda, que não foram observadas no exame ecocardiográfico convencional, sugerindo quadro de depressão miocárdica, até mesmo em cadelas com piometra sem quadro clínico evidente de sepse. Assim, essa modalidade pode ser útil no diagnóstico, pois pode detectar alterações cardíacas precoces, possibilitando uma intervenção terapêutica rápida.(AU)
The aim of this prospective study was to analyze the left ventricular function of dogs who had sepsis or not and diagnose myocardial depression early on through the two-dimensional feature tracking imaging (2D-FTI). Twenty-nine dogs diagnosed with pyometra, a pathology used as an experimental model for sepsis were evaluated. The animals were subjected to conventional echocardiography and 2D-FTI, and divided into three groups: Group I (control), group II (sepsis pyometra) and group III (no sepsis pyometra). Regarding the parameters of conventional echocardiography, there was no statistical difference between the groups. As for the radial Strain, group II and III had lower ventricular function at diagnosis (22.805.80 Group I; 18.455.96 Group II; 18.719.45 Group III; P = 0.032) and group III maintained this reduction in return. Regarding the radial Strain rate, only the III group had lower ventricular function at diagnosis (1.900.57 Group I; 1.910.70 Group II, 1.570.53 Group III; P = 0.021). For the Longitudinal Strain we observed lower ventricular function in groups II and III at diagnosis (11.043.38 Group I, Group II 8.593.97, 8.211.99; P = 0.048) and ten days after surgery (11.043.38 Group I; 9.002.16 Group II; 8.122.27 Group III; P = 0.048). The 2D-FTI was able to detect early changes in left ventricular function, suggesting myocardial depression frame, even in female dogs with pyometra without clear clinical picture of sepsis, which were not seen in conventional echocardiography. Thus, this model can be useful in diagnosis, because it can detect early cardiac changes, enabling a rapid therapeutic intervention.(AU)