1.
J Chromatogr A ; 1732: 465222, 2024 Sep 13.
Artículo en Inglés | MEDLINE | ID: mdl-39111183

RESUMEN

An innovative integrated paper-based microdevice was developed for protein separation by isoelectric focusing (IEF), allowing for robust design thanks to a 3D-printed holder integrating separation channel, reservoirs, and electrodes. To reach robustness and precision, the optimization focused on the holder geometry, the paper nature, the reservoir design, the IEF medium, and various focusing parameters. A well-established and stable pH gradient was obtained on a glass-fiber paper substrate with simple sponge reservoirs, and the integration of the electrodes in the holder led to a straightforward system. The separation medium composed of water/glycerol (85/15, v/v) allowed for reducing medium evaporation while being an efficient medium for most hydrophobic and hydrophilic proteins, compatible with mass spectrometry detection for further proteomics developments. To our knowledge, this is the first report of the use of glycerol solutions as a separation medium in a paper-based microdevice. Analytical performances regarding pH gradient generation, pI determination, separation efficiency, and resolution were estimated while varying the IEF experimental parameters. The overall process led to an efficient separation within 25 min. Then, this methodology was applied to a sample composed of saliva doped with proteins. A minimal matrix effect was evidenced, underscoring the practical viability of our platform. This low-cost, versatile and robust paper-based IEF microdevice opens the way to various applications, ranging from sample pre-treatment to integration in an overall proteomic-on-a-chip device.


Asunto(s)
Glicerol , Focalización Isoeléctrica , Papel , Proteínas , Focalización Isoeléctrica/instrumentación , Focalización Isoeléctrica/métodos , Proteínas/análisis , Proteínas/aislamiento & purificación , Glicerol/química , Glicerol/análisis , Concentración de Iones de Hidrógeno , Diseño de Equipo , Humanos , Dispositivos Laboratorio en un Chip , Saliva/química , Técnicas Analíticas Microfluídicas/instrumentación , Proteómica/métodos , Interacciones Hidrofóbicas e Hidrofílicas
2.
Artículo en Inglés | MEDLINE | ID: mdl-39018990

RESUMEN

The isoelectric focusing has realized various improvements, including the protocols and creation of mIEF (microcolumn isoelectric focusing) instruments with excellent sensitivity for screening of diabetes and beta thalassemia. However, the problem of manual sample loading and hydration for the mIEF limits the operational capacity for stably detecting and quantitating most abnormal hemoglobin (Hb). Herein, we provided a high stable sample loading protocol for analysis of alpha thalassemia and Hb variants. In contrast to the previous volume of 20 µl, a 100 µl blood sample solution in this protocol was optimized with mixture of 6.4-7.5 and 3-10 pH carrier ampholytes, pI markers and loaded for 30 mins IPG microcolumn hydration. The hydrated microcolumn was then automatically loaded onto the mIEF chip array to which CH3COOH and NH4OH act as anodic and cathodic solutions. Lastly, the IEF was run for 9 mins. Hb H, Barts, A1c, F, A2 and CS were simultaneously separated and focused with higher resolution and sensitivity in quantifying H and Barts as low as 0.6 and 0.5 % respectively. Accordingly, there was an enhanced stability and linearity with a rapid assay time of 45 secs per sample. Moreover, analysis showed a fitting linear relationship with conventional technology at R2 = 0.9803 for H and R2 = 0.9728 for Barts thereby indicating greater accuracy confirmed by the AUC. Hence, the developed protocol could simply be employed for high stable and throughput batch sample loading of hydration, and accurate separation and quantitation of Hb variants for alpha and beta thalassemia.


Asunto(s)
Focalización Isoeléctrica , Talasemia alfa , Humanos , Focalización Isoeléctrica/métodos , Talasemia alfa/sangre , Hemoglobinas Anormales/análisis , Hemoglobinas Anormales/química , Adulto , Modelos Lineales , Reproducibilidad de los Resultados , Límite de Detección
3.
Biochim Biophys Acta Proteins Proteom ; 1872(5): 141032, 2024 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-39004159

RESUMEN

The discovery of a subunit exchange in some oligomeric proteins, implying short-term dissociation of their oligomeric structure, requires new insights into the role of the quaternary structure in oligomeric protein stability and function. Here we demonstrate the effect of pH, protein concentration, and urea on the efficiency of GroES heptamer (GroES7) subunit exchange. A mixture of equimolar amounts of wild-type (WT) GroES7 and its Ala97Cys mutant modified with iodoacetic acid (97-carboxymethyl cysteine or CMC-GroES7) was incubated in various conditions and subjected to isoelectric focusing (IEF) in polyacrylamide gel. For each sample, there are eight Coomassie-stained electrophoretic bands showing different charges that result from a different number of included mutant subunits, each carrying an additional negative charge. The intensities of these bands serve to analyze the protein subunit exchange. The protein stability is evaluated using the transverse urea gradient gel electrophoresis (TUGGE). At pH 8.0, the intensities of the initial bands corresponding to WT-GroES7 and CMC-GroES7 are decreased with a half-time of (23 ± 2) min. The exchange decreases with decreasing pH and seems to be strongly hindered at pH 5.2 due to the protonation of groups with pK âˆ¼ 6.3, which stabilizes the protein quaternary structure. The destabilization of the protein quaternary structure caused by increased pH, decreased protein concentration, or urea accelerates the GroES subunit exchange. This study allows visualizing the subunit exchange in oligomeric proteins and confirms its direct connection with the stability of the protein quaternary structure.


Asunto(s)
Urea , Concentración de Iones de Hidrógeno , Urea/química , Subunidades de Proteína/química , Subunidades de Proteína/metabolismo , Estabilidad Proteica , Focalización Isoeléctrica
4.
Anal Chim Acta ; 1312: 342696, 2024 Jul 11.
Artículo en Inglés | MEDLINE | ID: mdl-38834281

RESUMEN

BACKGROUND: Hemoglobin (Hb) is an important protein in red blood cells and a crucial diagnostic indicator of diseases, e.g., diabetes, thalassemia, and anemia. However, there is a rare report on methods for the simultaneous screening of diabetes, anemia, and thalassemia. Isoelectric focusing (IEF) is a common separative tool for the separation and analysis of Hb. However, the current analysis of IEF images is time-consuming and cannot be used for simultaneous screening. Therefore, an artificial intelligence (AI) of IEF image recognition is desirable for accurate, sensitive, and low-cost screening. RESULTS: Herein, we proposed a novel comprehensive method based on microstrip isoelectric focusing (mIEF) for detecting the relative content of Hb species. There was a good coincidence between the quantitation of Hb via a conventional automated hematology analyzer and the one via mIEF with R2 = 0.9898. Nevertheless, our results showed that the accuracy of disease diagnosis based on the quantification of Hb species alone is as low as 69.33 %, especially for the simultaneous screening of multiple diseases of diabetes, anemia, alpha-thalassemia, and beta-thalassemia. Therefore, we introduced a ResNet1D-based diagnosis model for the improvement of screening accuracy of multiple diseases. The results showed that the proposed model could achieve a high accuracy of more than 90 % and a good sensitivity of more than 96 % for each disease, indicating the overwhelming advantage of the mIEF method combined with deep learning in contrast to the pure mIEF method. SIGNIFICANCE: Overall, the presented method of mIEF with deep learning enabled, for the first time, the absolute quantitative detection of Hb, relative quantitation of Hb species, and simultaneous screening of diabetes, anemia, alpha-thalassemia, and beta-thalassemia. The AI-based diagnosis assistant system combined with mIEF, we believe, will help doctors and specialists perform fast and precise disease screening in the future.


Asunto(s)
Anemia , Aprendizaje Profundo , Diabetes Mellitus , Focalización Isoeléctrica , Talasemia , Humanos , Focalización Isoeléctrica/métodos , Diabetes Mellitus/diagnóstico , Diabetes Mellitus/sangre , Talasemia/diagnóstico , Talasemia/sangre , Anemia/diagnóstico , Anemia/sangre , Hemoglobinas/análisis , Adulto
5.
J Sep Sci ; 47(11): e2400174, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38867483

RESUMEN

The review provides an overview of recent developments and applications of capillary electromigration (CE) methods for the determination of important physicochemical parameters of various (bio)molecules and (bio)particles. These parameters include actual and limiting (absolute) ionic mobilities, effective electrophoretic mobilities, effective charges, isoelectric points, electrokinetic potentials, hydrodynamic radii, diffusion coefficients, relative molecular masses, acidity (ionization) constants, binding constants and stoichiometry of (bio)molecular complexes, changes of Gibbs free energy, enthalpy and entropy and rate constants of chemical reactions and interactions, retention factors and partition and distribution coefficients. For the determination of these parameters, the following CE methods are employed: zone electrophoresis in a free solution or in sieving media, isotachophoresis, isoelectric focusing, affinity electrophoresis, electrokinetic chromatography, and electrochromatography. In the individual sections, the procedures for the determination of the above parameters by the particular CE methods are described.


Asunto(s)
Electroforesis Capilar , Proteínas/análisis , Proteínas/química , Termodinámica , Focalización Isoeléctrica/métodos , Peso Molecular , Humanos
6.
Electrophoresis ; 45(15-16): 1339-1355, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38700202

RESUMEN

Current postexposure prophylaxis of rabies includes vaccines, human rabies immunoglobulin (RIG), equine RIG, and recombinant monoclonal antibodies (mAb). In the manufacturing of rabies recombinant mAb, charge variants are the most common source of heterogeneity. Charge variants of rabies mAb were isolated by salt gradient cation exchange chromatography (CEX) to separate acidic and basic and main charge variants. Separated variants were further extensively characterized using orthogonal analytical techniques, which include secondary and tertiary structure determination by far and near ultraviolet circular dichroism spectroscopy. Charge and size heterogeneity were evaluated using CEX, isoelectric focusing (IEF), capillary-IEF, size exclusion chromatography, sodium dodecyl sulfate polyacrylamide gel electrophoresis, and western blotting. Antigen binding affinity was assessed by enzyme linked immuno-sorbent assay and rapid florescence foci inhibition test. Results from structural and physicochemical characterizations concluded that charge variants are formed due to posttranslational modification demonstrating that the charge heterogeneity, these charge variants did neither show any considerable physicochemical change nor affect its biological function. This study shows that charge variants are effective components of mAb and there is no need of deliberate removal, until biological functions of rabies mAb will get affected.


Asunto(s)
Anticuerpos Monoclonales , Focalización Isoeléctrica , Anticuerpos Monoclonales/química , Anticuerpos Monoclonales/aislamiento & purificación , Animales , Focalización Isoeléctrica/métodos , Cromatografía por Intercambio Iónico/métodos , Humanos , Anticuerpos Antivirales/inmunología , Anticuerpos Antivirales/aislamiento & purificación , Dicroismo Circular , Electroforesis en Gel de Poliacrilamida , Virus de la Rabia/inmunología , Cromatografía en Gel/métodos , Rabia , Western Blotting
7.
Anal Chem ; 96(21): 8648-8656, 2024 05 28.
Artículo en Inglés | MEDLINE | ID: mdl-38716690

RESUMEN

Microfluidic analytical tools play an important role in miniaturizing targeted proteomic assays for improved detection sensitivity, throughput, and automation. Microfluidic isoelectric focusing (IEF) can resolve proteoforms in lysate from low-to-single cell numbers. However, IEF assays often use carrier ampholytes (CAs) to establish a pH gradient for protein separation, presenting limitations like pH instability in the form of cathodic drift (migration of focused proteins toward the cathode). Immobilized pH gradient (IPG) gels reduce cathodic drift by covalently immobilizing the pH buffering components to a matrix. To our knowledge, efforts to implement IPG gels at the microscale have been limited to glass microdevices. To adapt IEF using IPGs to widely used microfluidic device materials, we introduce a polydimethylsiloxane (PDMS)-based microfluidic device and compare the microscale pH gradient stability of IEF established with IPGs, CAs, and a hybrid formulation of IPG gels and CAs (mixed-bed IEF). The PDMS-based IPG microfluidic device (µIPG) resolved analytes differing by 0.1 isoelectric point within a 3.5 mm separation lane over a 20 min focusing duration. During the 20 min duration, we observed markedly different cathodic drift velocities among the three formulations: 60.1 µm/min in CA-IEF, 2.5 µm/min in IPG-IEF (∼24-fold reduction versus CA-IEF), and 1.4 µm/min in mixed-bed IEF (∼43-fold reduction versus CA-IEF). Lastly, mixed-bed IEF in a PDMS device resolved green fluorescent protein (GFP) proteoforms from GFP-expressing human breast cancer cell lysate, thus establishing stability in lysate from complex biospecimens. µIPG is a promising and stable technique for studying proteoforms from small volumes.


Asunto(s)
Dimetilpolisiloxanos , Focalización Isoeléctrica , Focalización Isoeléctrica/métodos , Humanos , Dimetilpolisiloxanos/química , Concentración de Iones de Hidrógeno , Electrodos , Técnicas Analíticas Microfluídicas/instrumentación , Fuerza Protón-Motriz , Dispositivos Laboratorio en un Chip , Geles/química
8.
Int J Mol Sci ; 25(10)2024 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-38791450

RESUMEN

Multiple sclerosis is a chronic immune-mediated disorder of the central nervous system with a high heterogeneity among patients. In the clinical setting, one of the main challenges is a proper and early diagnosis for the prediction of disease activity. Current diagnosis is based on the integration of clinical, imaging, and laboratory results, with the latter based on the presence of intrathecal IgG oligoclonal bands in the cerebrospinal fluid whose detection via isoelectric focusing followed by immunoblotting represents the gold standard. Intrathecal synthesis can also be evidenced by the measurement of kappa free light chains in the cerebrospinal fluid, which has reached similar diagnostic accuracy compared to that of oligoclonal bands in the identification of patients with multiple sclerosis; moreover, recent studies have also highlighted its value for early disease activity prediction. This strategy has significant advantages as compared to using oligoclonal band detection, even though some issues remain open. Here, we discuss the current methods applied for cerebrospinal fluid analysis to achieve the most accurate diagnosis and for follow-up and prognosis evaluation. In addition, we describe new promising biomarkers, currently under investigation, that could contribute both to a better diagnosis of multiple sclerosis and to its monitoring of the therapeutic treatment response.


Asunto(s)
Biomarcadores , Esclerosis Múltiple , Bandas Oligoclonales , Humanos , Bandas Oligoclonales/líquido cefalorraquídeo , Esclerosis Múltiple/líquido cefalorraquídeo , Esclerosis Múltiple/diagnóstico , Esclerosis Múltiple/inmunología , Biomarcadores/líquido cefalorraquídeo , Pronóstico , Focalización Isoeléctrica
9.
Methods Mol Biol ; 2787: 281-291, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38656497

RESUMEN

This chapter provides a description of the procedure for two-dimensional electrophoresis that can be performed for any given gel size and isoelectric focusing range. This will enable the operator to recognize critical steps and gain sufficient information to generate 2D images suitable for computer-assisted analysis of 2D-gel, as well as mass spectrometry analysis for protein identification and characterization.


Asunto(s)
Electroforesis en Gel Bidimensional , Focalización Isoeléctrica , Proteínas de Plantas , Electroforesis en Gel Bidimensional/métodos , Proteínas de Plantas/aislamiento & purificación , Proteínas de Plantas/análisis , Focalización Isoeléctrica/métodos , Proteómica/métodos , Plantas/química , Espectrometría de Masas/métodos
10.
Eur J Pharm Biopharm ; 198: 114248, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38467335

RESUMEN

Fc Fusion protein represents a versatile molecular platform with considerable potential as protein therapeutics of which the charge heterogeneity should be well characterized according to regulatory guidelines. Angiotensin-converting enzyme 2 Fc fusion protein (ACE2Fc) has been investigated as a potential neutralizing agent to various coronaviruses, including the lingering SARS-CoV-2, as this coronavirus must bind to ACE2 to allow for its entry into host cells. ACE2Fc, an investigational new drug developed by Henlius (Shanghai China), has passed the Phase I clinical trial, but its huge amount of charge isoforms and complicated charge heterogeneity posed a challenge to charge variant investigation in pharmaceutical development. We employed offline free-flow isoelectric focusing (FF-IEF) fractionation, followed by detailed characterization of enriched ACE2Fc fractions, to unveil the structural origins of charge heterogeneity in ACE2Fc expressed by recombinant CHO cells. We adopted a well-tuned 3-component separation medium for ACE2Fc fractionation, the highest allowable voltage to maximize the FF-IEF separation window and a mild Protein A elution method for preservation of protein structural integrity. Through peptide mapping and other characterizations, we revealed that the intricate profiles of ACE2Fc charge heterogeneity are mainly caused by highly sialylated multi-antenna N-glycosylation. In addition, based on fraction characterization and in silico glycoprotein model analysis, we discovered that the large acidic glycans at N36, N73, and N305 of ACE2Fc were able to decrease the binding activity towards Spike (S) protein of SARS-CoV-2. Our study exemplifies the value of FF-IEF in highly complex fusion protein characterization and revealed a quantitative sialylation-activity relationship in ACE2Fc.


Asunto(s)
Glicoproteínas , Animales , Cricetinae , Cricetulus , China , Proteínas Recombinantes , Focalización Isoeléctrica/métodos , Unión Proteica
11.
Methods Mol Biol ; 2791: 113-119, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38532098

RESUMEN

Two-dimensional gel electrophoresis (2-DE) is a proteomic tool used for the separation of protein mixtures according to protein isoelectric point and molecular mass. Although gel-free quantitative and qualitative proteomic study techniques are now available, 2-DE remains a useful analytical tool. The presented protocol was performed to analyze the flower and leaf proteome of common buckwheat using 24 cm immobilized pH gradient strips (pH 4-7) and visualization of proteins on gels via colloidal Coomassie G-250 staining.


Asunto(s)
Fagopyrum , Proteoma , Proteoma/análisis , Proteómica , Focalización Isoeléctrica/métodos , Hojas de la Planta/química , Flores , Electroforesis en Gel Bidimensional/métodos , Geles , Concentración de Iones de Hidrógeno
12.
J Pharm Biomed Anal ; 244: 116120, 2024 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-38547650

RESUMEN

Charge heterogeneity is inherent to all therapeutic antibodies and arises from post-translational modifications (PTMs) and/or protein degradation events that may occur during manufacturing. Among therapeutic antibodies, the bispecific antibody (bsAb) containing two unique Fab arms directed against two different targets presents an additional layer of complexity to the charge profile. In the context of a bsAb, a single domain-specific PTM within one of the Fab domains may be sufficient to compromise target binding and could potentially impact the stability, safety, potency, and efficacy of the drug product. Therefore, characterization and routine monitoring of domain-specific modifications is critical to ensure the quality of therapeutic bispecific antibody products. We developed a Digestion-assisted imaged Capillary isoElectric focusing (DiCE) method to detect and quantitate domain-specific charge variants of therapeutic bispecific antibodies (bsAbs). The method involves enzymatic digestion using immunoglobulin G (IgG)-degrading enzyme of S. pyogenes (IdeS) to generate F(ab)2 and Fc fragments, followed by imaged capillary isoelectric focusing (icIEF) under reduced, denaturing conditions to separate the light chains (LCs) from the Fd domains. Our results suggest that DiCE is a highly sensitive method that is capable of quantitating domain-specific PTMs of a bsAb. In one case study, DiCE was used to quantitate unprocessed C-terminal lysine and site-specific glycation of Lys98 in the complementarity-determining region (CDR) of a bsAb that could not be accurately quantitated using conventional, platform-based charge variant analysis, such as intact icIEF. Quantitation of these PTMs by DiCE was comparable to results from peptide mapping, demonstrating that DiCE is a valuable orthogonal method for ensuring product quality. This method may also have potential applications for characterizing fusion proteins, antibody-drug conjugates, and co-formulated antibody cocktails.


Asunto(s)
Anticuerpos Biespecíficos , Focalización Isoeléctrica , Procesamiento Proteico-Postraduccional , Anticuerpos Biespecíficos/inmunología , Focalización Isoeléctrica/métodos , Fragmentos Fab de Inmunoglobulinas/inmunología , Fragmentos Fab de Inmunoglobulinas/química , Humanos , Inmunoglobulina G/inmunología , Fragmentos Fc de Inmunoglobulinas/química
13.
MAbs ; 16(1): 2313737, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38332713

RESUMEN

Therapeutic mAbs show a specific "charge fingerprint" that may affect safety and efficacy, and, as such, it is often identified as a critical quality attribute (CQA). Capillary iso-electric focusing (cIEF), commonly used for the evaluation of such CQA, provides an analytical tool to investigate mAb purity and identity across the product lifecycle. Here, we discuss the results of an analysis of a panel of antibody products by conventional and whole-column imaging cIEF systems performed as part of European Pharmacopoeia activities related to development of "horizontal standards" for the quality control of monoclonal antibodies (mAbs). The study aimed at designing and verifying an independent and transversal cIEF procedure for the reliable analysis of mAbs charge variants. Despite the use of comparable experimental conditions, discrepancies in the charge profile and measured isoelectric points emerged between the two cIEF systems. These data suggest that the results are method-dependent rather than absolute, an aspect known to experts in the field and pharmaceutical industry, but not suitably documented in the literature. Critical implications from analytical and regulatory perspectives, are herein thoughtfully discussed, with a special focus on the context of market surveillance and identification of falsified medicines.


Asunto(s)
Anticuerpos Monoclonales , Electroforesis Capilar , Anticuerpos Monoclonales/uso terapéutico , Anticuerpos Monoclonales/análisis , Focalización Isoeléctrica/métodos , Electroforesis Capilar/métodos , Punto Isoeléctrico , Control de Calidad
14.
Electrophoresis ; 45(15-16): 1295-1306, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38233206

RESUMEN

Charge heterogeneity analysis of monoclonal antibodies (mAbs) and complex formats, such as bispecifics, is crucial for therapeutic applications. In this study, we developed two capillary electrophoresis (CE)-based methods, capillary zone electrophoresis (CZE) and imaged capillary isoelectric focusing (iCIEF), for analyzing a broad spectrum of mAbs and complex mAb formats. For CZE, we introduced a new buffer system and optimized the background electrolyte (BGE) with an alternative dynamic coating agent and a superior polymeric additive. The pH of the BGE was increased, leading to enhanced resolution of high pI and complex format mAbs. In iCIEF, we identified an ampholyte combination offering a highly linear pH gradient and covering a suitable pH range. We also investigated alternatives to denaturing stabilizers and found that non-detergent sulfobetaine 195 exhibited excellent properties for iCIEF applications. These optimized methods provide a framework for the charge heterogeneity analysis of therapeutic mAbs and complex formats.


Asunto(s)
Anticuerpos Monoclonales , Electroforesis Capilar , Focalización Isoeléctrica , Electroforesis Capilar/métodos , Anticuerpos Monoclonales/análisis , Anticuerpos Monoclonales/química , Focalización Isoeléctrica/métodos , Concentración de Iones de Hidrógeno , Humanos
15.
Clin Chim Acta ; 552: 117685, 2024 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-38030031

RESUMEN

Hemoglobin (Hb) abnormalities, such as thalassemia and structural Hb variants, are among the most prevalent inherited diseases and are associated with significant mortality and morbidity worldwide. However, there were not comprehensive reviews focusing on different clinical analytical techniques, research methods and artificial intelligence (AI) used in clinical screening and research on hemoglobinopathies. Hence the review offers a comprehensive summary of recent advancements and breakthroughs in the detection of aberrant Hbs, research methods and AI uses as well as the present restrictions anddifficulties in hemoglobinopathies. Recent advances in cation exchange high performance liquid chromatography (HPLC), capillary zone electrophoresis (CZE), isoelectric focusing (IEF), flow cytometry, mass spectrometry (MS) and polymerase chain reaction (PCR) etc have allowed for the definitive detection by using advanced AIand portable point of care tests (POCT) integrating with smartphone microscopic classification, machine learning (ML) model, complete blood counts (CBC), imaging-based method, speedy immunoassay, and electrochemical-, microfluidic- and sensing-related platforms. In addition, to confirm and validate unidentified and novel Hbs, highly specialized genetic based techniques like PCR, reverse transcribed (RT)-PCR, DNA microarray, sequencing of genomic DNA, and sequencing of RT-PCR amplified globin cDNA of the gene of interest have been used. Hence, adequate utilization and improvement of available diagnostic and screening technologies are important for the control and management of hemoglobinopathies.


Asunto(s)
Hemoglobinopatías , Hemoglobinas Anormales , Talasemia , Humanos , Hemoglobinas Anormales/genética , Hemoglobinas Anormales/análisis , Inteligencia Artificial , Hemoglobinopatías/diagnóstico , Hemoglobinopatías/genética , Hemoglobinas/análisis , Focalización Isoeléctrica , Cromatografía Líquida de Alta Presión
16.
Blood Cells Mol Dis ; 104: 102758, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-37246072

RESUMEN

The genetic regulation of hemoglobin is complex and there are a number of genetic abnormalities that result in clinically important hemoglobin disorders. Here, we review the molecular pathophysiology of hemoglobin disorders and review both old and new methods of diagnosing these disorders. Timely diagnosis of hemoglobinopathies in infants is essential to coordinate optimal life-saving interventions, and accurate identification of carriers of deleterious mutations allows for genetic counseling and informed family planning. The initial laboratory workup of inherited disorders of hemoglobin should include a complete blood count (CBC) and peripheral blood smear, followed by carefully selected tests based on clinical suspicion and available methodology. We discuss the utility and limitations of the various methodologies to fractionate hemoglobin, including cellulose acetate and citrate agar hemoglobin electrophoresis, isoelectric focusing, high-resolution high-performance liquid chromatography, and capillary zone electrophoresis. Recognizing that most of the global burden of hemoglobin disorders exists in low- and middle-income countries, we review the increasingly available array of point-of-care-tests (POCT), which have an increasingly important role in expanding early diagnosis programs to address the global burden of sickle cell disease, including Sickle SCAN, HemoTypeSC, Gazelle Hb Variant, and Smart LifeLC. A comprehensive understanding of the molecular pathophysiology of hemoglobin and the globin genes, as well as a clear understanding of the utility and limitations of currently available diagnostic tests, is essential in reducing global disease burden.


Asunto(s)
Anemia de Células Falciformes , Hemoglobinopatías , Humanos , Hemoglobinopatías/diagnóstico , Hemoglobinopatías/genética , Hemoglobinas/genética , Anemia de Células Falciformes/genética , Focalización Isoeléctrica/métodos
17.
Sci Rep ; 13(1): 19862, 2023 11 14.
Artículo en Inglés | MEDLINE | ID: mdl-37963965

RESUMEN

Ferritin is a ubiquitous intracellular iron storage protein that plays a crucial role in iron homeostasis. Animal tissue ferritins consist of multiple isoforms (or isoferritins) with different proportions of H and L subunits that contribute to their structural and compositional heterogeneity, and thus physiological functions. Using size exclusion and anion exchange chromatography, capillary isoelectric focusing (cIEF), and SDS-capillary gel electrophoresis (SDS-CGE), we reveal for the first time a significant variation in ferritin subunit composition and isoelectric points, in both recombinant and native ferritins extracted from animal organs. Our results indicate that subunits composition is the main determinant of the mean pI of recombinant ferritin heteropolymers, and that ferritin microheterogeneity is a common property of both natural and recombinant proteins and appears to be an intrinsic feature of the cellular machinery during ferritin expression, regulation, post-translational modifications, and post-subunits assembly. The functional significance and physiological implications of ferritin heterogeneity in terms of iron metabolism, response to oxidative stress, tissue-specific functions, and pathological processes are discussed.


Asunto(s)
Ferritinas , Hierro , Animales , Ferritinas/metabolismo , Focalización Isoeléctrica , Electroforesis en Gel de Poliacrilamida , Hierro/metabolismo , Punto Isoeléctrico
18.
Anal Methods ; 15(43): 5885-5890, 2023 11 09.
Artículo en Inglés | MEDLINE | ID: mdl-37905587

RESUMEN

The active ingredients from tobacco extracts were continuously separated and purified using a homemade free-flow electrophoresis apparatus. A rectangular free flow electrophoresis device was constructed for the continuous separation and preparation, and the operating conditions of the device were optimized. The fractions obtained from the free-flowing component collection unit were then detected by HPLC and GC-MS. The results showed that a 90% methanol-water solution could maximize the extraction of the active components from tobacco. Chlorogenic acid and nicotine were enriched in three and four of 24 fractions, respectively, after free-flow isoelectric focusing electrophoresis. 2-Hydroxy-2-cyclopentene-1-one, 1-(2-methyl-1,3-oxathiolan-2-yl) ethanone, nornicotine, cotinine, and scopolamine were separated and enriched synchronously. Overall, the use of free-flow electrophoresis technology for the separation and purification of the active substances in tobacco can improve the comprehensive utilization rate of tobacco.


Asunto(s)
Cotinina , Nicotiana , Electroforesis , Focalización Isoeléctrica/métodos , Cromatografía Líquida de Alta Presión
19.
Mult Scler Relat Disord ; 79: 105035, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37864992

RESUMEN

BACKGROUND: CSF-specific oligoclonal bands (CSF-OCBs) can be used for dissemination in time (DIT) in the 2017 multiple sclerosis (MS) diagnostic criteria. A cut-off of ≥2 CSF-OCBs was recommended but studies have suggested ≥3 CSF-OCBs may be superior. OBJECTIVES: To assess utility of ≥2 and ≥3 CSF-OCBs as a cut-off for MS diagnosis. METHODS: Paired serum and CSF-OCBs sent to the Walton Centre, UK between July 2018 and June 2020 were included. CSF-OCBs were assessed using isoelectric focussing and reviewed by two blinded raters. Case records were reviewed. RESULTS: Of 1334 paired serum and CSF-OCB requests, 945 cases had sufficient clinical information. More than 1 CSF-OCB was detected in 268/945(28%) cases. Of these, 252 had ≥2 and 230 had ≥3 CSF-OCBs. The sensitivity and specificity for MS with ≥2 and ≥3 CSF-OCBs were 91.7%, 91.2%, 90.2% and 93.8% respectively. Only 3/22 patients with 2 CSF-OCBs had MS. In 25% of patients, CSF-OCBs reduced time to MS diagnosis (median 437.5 days (28-1332)). CONCLUSION: Although cut-offs of ≥2 or ≥3 CSF-OCBs performed similarly well, 2 CSF-OCBs were frequently seen with non-inflammatory pathology. Use of ≥3 CSF-OCBs for MS diagnosis should be considered. CSF analysis reduced time to MS diagnosis by approximately 14 months.


Asunto(s)
Esclerosis Múltiple , Humanos , Esclerosis Múltiple/diagnóstico , Bandas Oligoclonales , Focalización Isoeléctrica , Sensibilidad y Especificidad , Inmunoglobulina G
20.
Anal Biochem ; 680: 115312, 2023 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-37683714

RESUMEN

Recombinant monoclonal antibodies (mAbs) have been spurring the rapid growth of commercial biotherapeutics. During production their charge heterogeneity must be assessed as a critical quality attribute to ensure safety, efficacy, and potency. Although imaged capillary isoelectric focusing (icIEF) is a powerful tool for this process, it could be improved further with tandem high-resolution mass spectrometry (HRMS). In this work, a nano-electrospray ionization (nano-ESI) apparatus was constructed to directly couple icIEF to HRMS. The system was evaluated with the standard NISTmAb, as well as more complex mAb, bi-specific antibody, and fusion protein samples. NISTmAb concentrations as low as 0.25 mg/ml demonstrated excellent sensitivity. There were good repeatabilities at 1 mg/ml with 7.58% and 8.01% RSDs for intention time and MS intensity, respectively, and the HRMS signal showed a strong linearity (R = 0.9983) across different concentrations. Meanwhile, the fingerprinting of the complex samples illustrated the versatility and potential of icIEF-HRMS. icIEF-HRMS developed can provide a comprehensive understanding of the underlying structural modifications that impact protein charge heterogeneity. Compared to the traditional ESI, nano-ESI can significantly improve sensitivity while maintaining a reasonable repeatability and throughput. Furthermore, the interface is much easier to connect, and is compatible with many commercial HRMS instruments.


Asunto(s)
Focalización Isoeléctrica Capilar , Espectrometría de Masas en Tándem , Focalización Isoeléctrica , Anticuerpos Monoclonales
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...