Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Int J Nanomedicine ; 15: 3843-3850, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32581534

RESUMEN

PURPOSE: Despite tremendous results achieved by immune checkpoint inhibitors, most patients are not responders, mainly because of the lack of a pre-existing anti-tumor immune response. Thus, solutions to efficiently prime this immune response are currently under intensive investigations. Radiotherapy elicits cancer cell death, generating an antitumor-specific T cell response, turning tumors in personalized in situ vaccines, with potentially systemic effects (abscopal effect). Nonetheless, clinical evidence of sustained anti-tumor immunity as abscopal effect are rare. METHODS: Hafnium oxide nanoparticles (NBTXR3) have been designed to increase energy dose deposit within cancer cells. We examined the effect of radiotherapy-activated NBTXR3 on anti-tumor immune response activation and abscopal effect production using a mouse colorectal cancer model. RESULTS: We demonstrate that radiotherapy-activated NBTXR3 kill more cancer cells than radiotherapy alone, significantly increase immune cell infiltrates both in treated and in untreated distant tumors, generating an abscopal effect dependent on CD8+ lymphocyte T cells. CONCLUSION: These data show that radiotherapy-activated NBTXR3 could increase local and distant tumor control through immune system priming. Our results may have important implications for immunotherapeutic agent combination with radiotherapy.


Asunto(s)
Antineoplásicos Inmunológicos/farmacología , Neoplasias Colorrectales/tratamiento farmacológico , Neoplasias Colorrectales/radioterapia , Hafnio/farmacología , Óxidos/farmacología , Animales , Antineoplásicos Inmunológicos/química , Antineoplásicos Inmunológicos/farmacocinética , Disponibilidad Biológica , Linfocitos T CD8-positivos/inmunología , Neoplasias Colorrectales/inmunología , Femenino , Hafnio/química , Hafnio/farmacocinética , Nanopartículas del Metal/administración & dosificación , Nanopartículas del Metal/química , Ratones Endogámicos BALB C , Neoplasias Experimentales/tratamiento farmacológico , Neoplasias Experimentales/inmunología , Neoplasias Experimentales/radioterapia , Óxidos/química , Óxidos/farmacocinética
2.
Invest Radiol ; 51(12): 776-785, 2016 12.
Artículo en Inglés | MEDLINE | ID: mdl-27299578

RESUMEN

OBJECTIVE: Characterization of BAY-576, a new x-ray contrast agent which is not based on iodine, but rather on the heavy metal hafnium. Compared with iodine, hafnium provides better x-ray absorption in the energy range of computed tomography (CT) and allows images of comparable quality to be acquired at a significantly reduced radiation dose. MATERIALS AND METHODS: A range of standard methods were used to explore the physicochemistry of BAY-576 as well as its tolerability in in vitro assays, its pharmacokinetics and toxicology in rats, and its performance in CT imaging in rabbits. RESULTS: BAY-576 is an extraordinarily stable chelate with a metal content of 42% (wt/wt) and with excellent water solubility. Formulations of 300 mg Hf/mL exhibited viscosity (3.3-3.6 mPa) and osmolality (860-985 mOsm/kg) in the range of nonionic x-ray agents. No relevant effects on erythrocytes, the coagulation, or complement system or on a panel of 87 potential biological targets were observed. The compound did not bind to plasma proteins of a number of species investigated. After intravenous injection in rats, it was excreted fast and mainly via the kidneys. Its pharmacokinetics was comparable to known extracellular contrast agents. A dose of 6000 mg Hf/kg, approximately 10 to 20 times the expected diagnostic dose, was well tolerated by rats with only moderate adverse effects. Computed tomography imaging in rabbits bearing a tumor in the liver demonstrated excellent image quality when compared with iopromide at the same contrast agent dose in angiography during the arterial phase. At 70% of the radiation dose, BAY-576 provided a contrast-to-noise ratio of the tumor, which was equivalent to iopromide at 100% radiation dose. CONCLUSIONS: The profile of BAY-576 indicates its potential as the first compound in a new class of noniodine x-ray contrast agents, which can contribute to the reduction of the radiation burden in contrast-enhanced CT imaging.


Asunto(s)
Medios de Contraste/farmacocinética , Hafnio/farmacocinética , Neoplasias Hepáticas Experimentales/diagnóstico por imagen , Intensificación de Imagen Radiográfica/métodos , Tomografía Computarizada por Rayos X/métodos , Animales , Medios de Contraste/toxicidad , Modelos Animales de Enfermedad , Hafnio/toxicidad , Hígado/diagnóstico por imagen , Fantasmas de Imagen , Conejos , Ratas , Ratas Wistar
3.
Future Oncol ; 8(9): 1167-81, 2012 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-23030491

RESUMEN

AIM: There is considerable interest in approaches that could improve the therapeutic window of radiotherapy. In this study, hafnium oxide nanoparticles were designed that concentrate in tumor cells to achieve intracellular high-energy dose deposit. MATERIALS & METHODS: Conventional methods were used, implemented in different ways, to explore interactions of these high-atomic-number nanoparticles and ionizing radiation with biological systems. RESULTS: Using the Monte Carlo simulation, these nanoparticles, when exposed to high-energy photons, were shown to demonstrate an approximately ninefold radiation dose enhancement compared with water. Importantly, the nanoparticles show satisfactory dispersion and persistence within the tumor and they form clusters in the cytoplasm of cancer cells. Marked antitumor activity is demonstrated in human cancer models. Safety is similar in treated and control animals as demonstrated by a broad program of toxicology evaluation. CONCLUSION: These findings, supported by good tolerance, provide the basis for developing this new type of nanoparticle as a promising anticancer approach in human patients.


Asunto(s)
Hafnio/administración & dosificación , Nanopartículas/administración & dosificación , Neoplasias/radioterapia , Óxidos/administración & dosificación , Fármacos Sensibilizantes a Radiaciones/administración & dosificación , Animales , Línea Celular Tumoral , Supervivencia Celular/efectos de la radiación , Simulación por Computador , Endosomas/metabolismo , Endosomas/patología , Femenino , Hafnio/efectos adversos , Hafnio/farmacocinética , Humanos , Ratones , Ratones Desnudos , Modelos Biológicos , Método de Montecarlo , Nanopartículas/efectos adversos , Neoplasias/diagnóstico por imagen , Neoplasias/patología , Óxidos/efectos adversos , Óxidos/farmacocinética , Fármacos Sensibilizantes a Radiaciones/efectos adversos , Fármacos Sensibilizantes a Radiaciones/farmacocinética , Radiografía , Carga Tumoral/efectos de la radiación , Ensayos Antitumor por Modelo de Xenoinjerto
4.
Health Phys ; 84(4): 469-76, 2003 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-12705445

RESUMEN

Internal radiation from inhalation of hafnium tritide aerosols may be a significant radiation protection problem encountered by nuclear facility workers. Based on experimental results of the rat intratracheally instilled with hafnium tritide particles and on a self-absorption factor of beta particles determined by a numerical method, a biokinetic model was developed for inhaled particles of hafnium tritide. Results show that lung burdens of the tritide are well represented by a two-component exponential equation; biological half-lives derived for the retention of 3H in lung were 4.9 d and 1,257 d for the short- and long-term clearance, respectively. The tritium clearance rate via urine or feces was described by bi-phase exponential components. At the end of the experiment (180 d after instillation), only approximately 30% of the initial lung burden of 3H had been eliminated, of which approximately 98% was excreted via feces and 2% in urine, but none through exhaled air. Results also showed that a large percentage (70%) of the hafnium tritide initially present in lung still remained in the organ 6 mo after the exposure. The calculation of the radiation dose indicates that the cumulative dose to the lung directly from the tritide particles was approximately 10(6) times the lung dose from the dissolved tritium in the lung region. The committed effective dose to the lung was estimated to be 5.41 x 10(-10) Sv Bq(-1), which is over 99% of that to the whole body. The dose to the liver was 6.00 x 10(-15) Sv Bq(-1). This information will be useful in developing new guidelines for radiation protection purposes.


Asunto(s)
Hafnio/farmacocinética , Exposición por Inhalación , Pulmón/metabolismo , Modelos Biológicos , Radiometría/métodos , Administración por Inhalación , Aerosoles/farmacocinética , Animales , Carga Corporal (Radioterapia) , Semivida , Humanos , Masculino , Tasa de Depuración Metabólica , Especificidad de Órganos , Tamaño de la Partícula , Dosis de Radiación , Ratas , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
5.
Health Phys ; 82(6): 817-24, 2002 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-12046753

RESUMEN

Metal tritide is widely used for research, purification, compression, and storage of tritium. The current understanding of metal tritide and its radiation dosimetry for internal exposure is limited, and ICRP publications do not provide the tritium dosimetry for hafnium tritide. The current radiation protection guidelines for metal tritide particles (including hafnium tritide) are based on the assumption that their biological behavior is similar to tritiated water, which is completely absorbed by the body. However, the solubility of metal tritide particles depends on the chemical form of the material. The biological half-live of hafnium tritide particles and the dosimetry of an inhalation exposure to those particles could be quite different from tritiated water. This paper describes experiments on the dissolution rate of hafnium tritide particles in a simulated lung fluid. The results showed that less than 1% of the tritium was dissolved in the simulated lung fluid for hafnium tritide particles after 215 d. The short-term and long-term dissolution half times were 46 and 4.28 x 10(5) d, respectively. This indicates that hafnium tritide is an extremely insoluble material. Self-absorption of beta rays in the hafnium tritide particles was estimated by a numerical method. The dose coefficients were calculated as a function of particle size using in vitro solubility data and a calculated self-absorption factor. The dose coefficient decreased with aerodynamic diameters in the range of 0.25 to 10 microm, mainly because the self-absorption factor decreased with increasing particle size. For a particle 1 microm in aerodynamic diameter, the dose coefficient of a hafnium tritide particle was about 10 times higher than that of tritiated water but was about 1.4 times lower than that calculated by ICRP Publication 71 for Type S tritiated particles. The ICRP estimate did not include a self-absorption factor and thus might have overestimated the dose. This finding has significant implications for current health protection guidelines.


Asunto(s)
Contaminantes Radiactivos del Aire/farmacocinética , Hafnio/farmacocinética , Pulmón/efectos de la radiación , Modelos Biológicos , Tritio/farmacocinética , Humanos , Exposición por Inhalación , Pulmón/anatomía & histología , Pulmón/fisiología , Microscopía Electrónica , Tamaño de la Partícula , Dosis de Radiación , Protección Radiológica , Radiometría , Solubilidad
6.
Radiat Prot Dosimetry ; 93(1): 55-60, 2001.
Artículo en Inglés | MEDLINE | ID: mdl-11548328

RESUMEN

Metal tritides with low dissolution rates may have residence times in the lungs which are considerably longer than the biological half-time normally associated with tritium in body water, resulting in long-term irradiation of the lungs by low energy beta particles and bremsstrahlung X rays. Samples of hafnium tritide were placed in a lung simulant fluid to determine approximate lung dissolution rates. Hafnium hydride samples were analysed for particle size distribution with a scanning electron microscope. Lung simulant data indicated a biological dissolution half-time for hafnium tritide on the order of 10(5) d. Hafnium hydride particle sizes ranged between 2 and 10 microns, corresponding to activity median aerodynamic diameters of 5 to 25 microns. Review of in vitro dissolution data, development of a biokinetic model, and determination of secondary limits for 1 micron AMAD particles are presented and discussed.


Asunto(s)
Hafnio/análisis , Exposición por Inhalación , Pulmón/efectos de la radiación , Tritio/análisis , Aerosoles , Hafnio/farmacocinética , Humanos , Microscopía Electrónica de Rastreo , Modelos Biológicos , Modelos Teóricos , Tamaño de la Partícula , Dosis de Radiación , Tritio/farmacocinética
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA