Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 42.470
Filtrar
1.
Luminescence ; 39(7): e4819, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38956814

RESUMEN

Mefenamic acid, renowned for its analgesic properties, stands as a reliable choice for alleviating mild to moderate pain. However, its versatility extends beyond pain relief, with ongoing research unveiling its promising therapeutic potential across diverse domains. A straightforward, environmentally friendly, and sensitive spectrofluorometric technique has been developed for the precise quantification of the analgesic medication, mefenamic acid. This method relies on the immediate reduction of fluorescence emitted by a probe upon interaction with varying concentrations of the drug. The fluorescent probe utilized, N-phenyl-1-naphthylamine (NPNA), was synthesized in a single step, and the fluorescence intensities were measured at 480 nm using synchronous fluorescence spectroscopy with a wavelength difference of 200 nm. Temperature variations and lifetime studies indicated that the quenching process was static. The calibration curve exhibited linearity within the concentration range of 0.50-9.00 µg/mL, with a detection limit of 60.00 ng/mL. Various experimental parameters affecting the quenching process were meticulously examined and optimized. The proposed technique was successfully applied to determine mefenamic acid in pharmaceutical formulations, plasma, and urine, yielding excellent recoveries ranging from 98% to 100.5%. The greenness of the developed method was evaluated using three metrics: the Analytical Eco-scale, AGREE, and the Green Analytical Procedure Index.


Asunto(s)
Colorantes Fluorescentes , Ácido Mefenámico , Espectrometría de Fluorescencia , Ácido Mefenámico/análisis , Ácido Mefenámico/química , Ácido Mefenámico/orina , Colorantes Fluorescentes/química , Colorantes Fluorescentes/síntesis química , Humanos , Estructura Molecular , Preparaciones Farmacéuticas/química , Preparaciones Farmacéuticas/análisis , Límite de Detección
2.
J Agric Food Chem ; 72(26): 14967-14974, 2024 Jul 03.
Artículo en Inglés | MEDLINE | ID: mdl-38957086

RESUMEN

Nanobodies (Nbs) serve as powerful tools in immunoassays. However, their small size and monovalent properties pose challenges for practical application. Multimerization emerges as a significant strategy to address these limitations, enhancing the utilization of nanobodies in immunoassays. Herein, we report the construction of a Salmonella-specific fenobody (Fb) through the fusion of a nanobody to ferritin, resulting in a self-assembled 24-valent nanocage-like structure. The fenobody exhibits a 35-fold increase in avidity compared to the conventional nanobody while retaining good thermostability and specificity. Leveraging this advancement, three ELISA modes were designed using Fb as the capture antibody, along with unmodified Nb422 (FbNb-ELISA), biotinylated Nb422 (FbBio-ELISA), and phage-displayed Nb422 (FbP-ELISA) as the detection antibody, respectively. Notably, the FbNb-ELISA demonstrates a detection limit (LOD) of 3.56 × 104 CFU/mL, which is 16-fold lower than that of FbBio-ELISA and similar to FbP-ELISA. Moreover, a fenobody and nanobody sandwich chemiluminescent enzyme immunoassay (FbNb-CLISA) was developed by replacing the TMB chromogenic substrate with luminal, resulting in a 12-fold reduction in the LOD. Overall, the ferritin-displayed technology represents a promising methodology for enhancing the detection performance of nanobody-based sandwich ELISAs, thereby expanding the applicability of Nbs in food detection and other fields requiring multivalent modification.


Asunto(s)
Ensayo de Inmunoadsorción Enzimática , Ferritinas , Salmonella , Anticuerpos de Dominio Único , Ferritinas/inmunología , Ferritinas/química , Ferritinas/genética , Anticuerpos de Dominio Único/química , Anticuerpos de Dominio Único/genética , Anticuerpos de Dominio Único/inmunología , Salmonella/inmunología , Salmonella/genética , Ensayo de Inmunoadsorción Enzimática/métodos , Límite de Detección , Afinidad de Anticuerpos , Anticuerpos Antibacterianos/inmunología , Inmunoensayo/métodos
3.
Anal Chim Acta ; 1316: 342818, 2024 Aug 08.
Artículo en Inglés | MEDLINE | ID: mdl-38969402

RESUMEN

Interdigitated electrodes (IDEs) enable electrochemical signal enhancement through repeated reduction and oxidation of the analyte molecule. Porosity on these electrodes is often used to lower the impedance background. However, their high capacitive current and signal interferences with oxygen reduction limit electrochemical detection ability. We present utilization of alkanethiol modification on nanoporous gold (NPG) electrodes to lower their background capacitance and chemically passivate them from interferences due to oxygen reduction, while maintaining their fast electron transfer rates, as validated by lower separation between anodic and cathodic peaks (ΔE) and lower charge transfer resistance (Rct) values in comparison to planar gold electrodes. Redox amplification based on this modification enables sensitive detection of various small molecules, including pyocyanin, p-aminophenol, and selective detection of dopamine in the presence of ascorbic acid. Alkanethiol NPG arrays are applied as a multiplexed sensor testbed within a well plate to screen binding of various peptide receptors to the SARS COV2 S-protein by using a sandwich assay for conversion of PAPP (4-aminophenyl phosphate) to PAP (p-aminophenol), by the action of AP (alkaline phosphatase), which is validated against optical ELISA screens of the peptides. Such arrays are especially of interest in small volume analytical settings with complex samples, wherein optical methods are unsuitable.


Asunto(s)
Aminofenoles , Técnicas Electroquímicas , Oro , Microelectrodos , Nanoporos , Oxidación-Reducción , Oro/química , Técnicas Electroquímicas/instrumentación , Aminofenoles/química , Compuestos de Sulfhidrilo/química , Dopamina/análisis , Dopamina/química , Técnicas Biosensibles , Límite de Detección , SARS-CoV-2/aislamiento & purificación , Humanos
4.
Anal Chim Acta ; 1316: 342824, 2024 Aug 08.
Artículo en Inglés | MEDLINE | ID: mdl-38969403

RESUMEN

BACKGROUND: As is well documented, prostate cancer (PCa) being the second most prevalent cancer in men worldwide, emphasizing the importance of early diagnosis for prognosis. However, conventional prostate-specific antigen (PSA) testing lacks sufficient diagnostic efficiency due to its relatively low sensitivity and limited detection range. Mounting evidence suggests that matrix metalloproteinase 9 (MMP-9) expression increases with the aggressive behavior of PCa, highlighting the significance of detecting the serum level of MMP-9 in patients. Developing a non-immune rapid, portable MMP-9 detection strategy and investigating its representativeness of PCa serum markers hold considerable implications. RESULTS: Herein, our study developed a simple, homogeneous dual fluorescence and smartphone-assisted red-green-blue (RGB) visualization peptide sensor of MMP-9, utilizing cadmium telluride quantum dots (CdTe QDs) and calcein as signal reporters. The essence of our approach revolves around the proteolytic ability of MMP-9, exploiting the selective recognition of molecule-Cu2+ complexes with different molecular weights by CdTe QDs and calcein. Under optimized conditions, the limits of detection (LODs) for MMP-9 were 0.5 pg/mL and 6 pg/mL using fluorescence and RGB values readouts, respectively. Indeed, this strategy exhibited robust specificity and anti-interference ability. MMP-9 was quantified in 42 clinical serum samples via dual-fluorescence analysis, with 12 samples being visually identified with a smartphone. According to receiver operating characteristic curve (ROC) analysis, its sensitivity and specificity were 90 % and 100 %, respectively, with an area under curve (AUC) value of 0.903. SIGNIFICANCE AND NOVELTY: Of note, the results of the aforementioned analysis were highly consistent with the serum level of PSA, clinical color Doppler flow imaging (CDFI), and histopathological results. Therefore, this simple, rapid, homogeneous fluorescence and visualization strategy can reliably measure MMP-9 levels and exhibit promising potential in point-of-care testing (POCT) applications for PCa patients.


Asunto(s)
Compuestos de Cadmio , Colorantes Fluorescentes , Metaloproteinasa 9 de la Matriz , Puntos Cuánticos , Telurio , Humanos , Colorantes Fluorescentes/química , Telurio/química , Metaloproteinasa 9 de la Matriz/sangre , Puntos Cuánticos/química , Compuestos de Cadmio/química , Masculino , Neoplasias de la Próstata/sangre , Neoplasias de la Próstata/diagnóstico , Teléfono Inteligente , Espectrometría de Fluorescencia , Límite de Detección
5.
Anal Chim Acta ; 1316: 342827, 2024 Aug 08.
Artículo en Inglés | MEDLINE | ID: mdl-38969404

RESUMEN

BACKGROUND: In recent years, miRNAs have emerged as potentially valuable tumor markers, and their sensitive and accurate detection is crucial for early screening and diagnosis of tumors. However, the analysis of miRNAs faces significant challenges due to their short sequence, susceptibility to degradation, high similarity, low expression level in cells, and stringent requirements for in vitro research environments. Therefore, the development of sensitive and efficient new methods for the detection of tumor markers is crucial for the early intervention of related tumors. RESULTS: An ultrasensitive electrochemical/colorimetric dual-mode self-powered biosensor platform is established to detect microRNA-21 (miR-21) via a multi-signal amplification strategy. Gold nanoparticles (AuNPs) and VS4 nanosheets self-assembled 3D nanorods (VS4-Ns-Nrs) are prepared for constructing a superior performance enzyme biofuel cell (EBFC). The double-signal amplification strategy of Y-shaped DNA nanostructure and catalytic hairpin assembly (CHA) is adopted to further improve enhance the strength and specificity of the output signal. In addition, a capacitor is matched with EBFC to generate an instantaneous current that is amplified several times, and the output detection signal is improved once more. At the same time, electrochemical and colorimetric methods are used for dual-mode strategy to achieve the accuracy of detection. The linear range of detection is from 0.001 pg/mL to 1000 pg/mL, with a relatively low limit of detection (LOD) of 0.16 fg/mL (S/N = 3). SIGNIFICANCE: The established method enables accurate and sensitive detection of markers in patients with lung cancer, providing technical support and data reference for precise identification. It is anticipated to offer a sensitive and practical new technology and approach for early diagnosis, clinical treatment, and drug screening of cancer and other related major diseases.


Asunto(s)
Biomarcadores de Tumor , Técnicas Biosensibles , Colorimetría , Técnicas Electroquímicas , Oro , Neoplasias Pulmonares , Nanopartículas del Metal , MicroARNs , Humanos , Técnicas Biosensibles/métodos , Neoplasias Pulmonares/diagnóstico , Técnicas Electroquímicas/métodos , Biomarcadores de Tumor/análisis , Biomarcadores de Tumor/sangre , Oro/química , MicroARNs/análisis , Nanopartículas del Metal/química , Límite de Detección
6.
Anal Chim Acta ; 1316: 342842, 2024 Aug 08.
Artículo en Inglés | MEDLINE | ID: mdl-38969406

RESUMEN

BACKGROUND: Fluoroquinolones (FQs) are widely used in livestock and poultry industry because of their satisfactory effects in preventing and treating bacterial infection. However, due to irrational use and poor biodegradability, FQs can easily remain in food animals and further enter the human body through the food chain. Therefore, accurate and sensitive detection of FQs residues in animal-origin food is significant. The traditional methods commonly used for FQs detection have some limitations. Ratiometric fluorescence detection technology has the advantages of fast, sensitive, self-correcting, and easy visualization. However, the reports on the use of ratiometric fluorescence probes for FQs detection are limited. RESULTS: In this work, a novel probe was proposed for ratiometric fluorescent analysis of FQs. In this probe, the fluorescence of dithioerythritol stabilized copper nanoclusters (DTE-Cu NCs) was significantly enhanced due to the Tb3+ triggered aggregation-induced emission effect. FQs bound Tb3+ in Tb3+/DTE-Cu NCs through carboxyl and carbonyl groups, so that Tb3+ was effectively sensitized to emit green fluorescence. However, the red fluorescence of DTE-Cu NCs was not interfered. The fluorescence of the probe transformed from red to green with the increase of FQs concentration. Using norfloxacin (NOR), difloxacin (DIF), and enrofloxacin (ENR) as FQs simulants, this probe showed a sensitive linear response ranged from 0.025 to 22.5 µM, with the limits of detection of 9.6 nM, 9.3 nM, and 7.7 nM. The application potential for FQs detection was verified via a standard addition assay of egg samples with the recovery rate of 90.4 %-114.7 %. SIGNIFICANT: The fluorescence probe based on Tb3+/DTE-Cu NCs is expected to realize the ratiometric fluorescence sensitive detection of FQs. The establishment of this simple, effective, and rapid detection platform opens up a new way for the detection of FQs residues in animal-origin foods, and also provides a new idea for the design of rapid detection platforms for other hazard factors.


Asunto(s)
Cobre , Colorantes Fluorescentes , Fluoroquinolonas , Terbio , Cobre/química , Cobre/análisis , Fluoroquinolonas/análisis , Fluoroquinolonas/química , Colorantes Fluorescentes/química , Terbio/química , Espectrometría de Fluorescencia , Nanopartículas del Metal/química , Animales , Límite de Detección
7.
Anal Chim Acta ; 1316: 342843, 2024 Aug 08.
Artículo en Inglés | MEDLINE | ID: mdl-38969407

RESUMEN

BACKGROUND: MicroRNAs (miRNAs) are important non-coding RNA entities that affect gene expression and function by binding to target mRNAs, leading to degradation of the mRNAs or inhibiting their translation. MiRNAs are widely involved in a variety of biological processes, such as cell differentiation, development, metabolism, and apoptosis. In addition, miRNAs are associated with many diseases, including cancer. However, conventional detection techniques often suffer from shortcomings such as low sensitivity, so we need to develop a rapid and efficient detection strategy for accurate detection of miRNAs. RESULTS: We have developed an innovative homogeneous electrochemiluminescence (ECL) biosensor. This biosensor employs CRISPR/Cas12a gene editing technology for accurate and efficient detection of microRNA (miRNA). Compared to conventional technologies, this biosensor employs a unique homogeneous detection format that eliminates laborious probe fixation steps and greatly simplifies the detection process. By using two amplification techniques - isothermal amplification and T7 RNA polymerase amplification - the biosensor improves the sensitivity and specificity of the assay, providing excellent detection performance in the assay. This makes it possible to evaluate miRNA directly from a variety of biological samples such as cell lysates and diluted human serum. Experimental results convincingly demonstrate the extraordinary performance of this biosensor, including its extremely low detection limit of 1.27 aM, high sensitivity, reproducibility and stability. SIGNIFICANCE: The application of our constructed sensor in distinguishing between cancerous and non-cancerous cell lines highlights its potential for early cancer detection and monitoring. This innovative approach represents a major advancement in the field of miRNA detection, providing a user-friendly, cost-effective, and sensitive solution with broad implications for clinical diagnosis and patient care, especially in point-of-care settings.


Asunto(s)
Técnicas Biosensibles , Sistemas CRISPR-Cas , Técnicas Electroquímicas , Mediciones Luminiscentes , MicroARNs , Humanos , Técnicas Biosensibles/métodos , MicroARNs/análisis , MicroARNs/sangre , MicroARNs/genética , Sistemas CRISPR-Cas/genética , Técnicas Electroquímicas/métodos , Límite de Detección , Proteínas Asociadas a CRISPR/genética , Proteínas Bacterianas , Endodesoxirribonucleasas
8.
Anal Chim Acta ; 1316: 342861, 2024 Aug 08.
Artículo en Inglés | MEDLINE | ID: mdl-38969410

RESUMEN

BACKGROUND: The high toxicity of hexavalent chromium [Cr (VI)] could not only cause harmful effects on humans, including carcinogenicity, respiratory issues, genetic damage, and skin irritation, but also contaminate drinking water sources, aquatic ecosystems, and soil, impairing the reproductive capacity, growth, and survival of organisms. Due to these harmful effects, detecting toxic Cr (VI) is of great significance. However, the rapid, simple, and efficient detection at a low Cr (VI) concentration is extremely challenging, especially in an acidic condition (existing as HCrO4-) due to its low adsorption free energy. RESULTS: A diketopyrrolopyrrole-based small molecule (DPPT-PhSMe) is designed and characterized to act as a chemosensor, which allows a high selectivity to Cr (VI) at an acidic condition with a low limit of detection to 10-8 M that is two orders of magnitude lower than the cut of limit (1 µM) recommended by World Health Organization (WHO). Mechanism study indicates that the rich sulfur atoms enhance the affinity to HCrO4-. Combining with favorable features of diketopyrrolopyrrole, DPPT-PhSMe not only allows dual-mode detection (colorimetric and spectroscopic) to Cr (VI), but also enables disposable paper-based sensor for naked-eye detection to Cr (VI) from fully aqueous media. The investigation of DPPT-PhSMe chemosensor for the quantification of Cr (VI) in real life samples demonstrates a high reliability and accuracy with an average percentage recovery of 102.1 % ± 4 (n = 3). SIGNIFICANCE: DPPT-PhSMe represents the first diketopyrrolopyrrole-derived chemosensor for efficient detection to toxic Cr (VI), not only providing a targeted solution to the bottleneck of Cr (VI) detection in acidic conditions (existing as HCrO4-) caused by its low adsorption free energy, but also opening a new scenario for simple, selective, and efficient Cr (VI) detection with conjugated dye molecules.


Asunto(s)
Cromo , Límite de Detección , Pirroles , Contaminantes Químicos del Agua , Cromo/análisis , Pirroles/química , Contaminantes Químicos del Agua/análisis , Cetonas/química , Cetonas/análisis , Agua/química
9.
Anal Chim Acta ; 1316: 342852, 2024 Aug 08.
Artículo en Inglés | MEDLINE | ID: mdl-38969409

RESUMEN

BACKGROUND: With the advent of personalized medical approaches, precise and tailored treatments are expected to become widely accepted for the prevention and treatment of diabetes. Paper-based colorimetric sensors that function in combination with smartphones have been rapidly developed in recent years because it does not require additional equipment and is inexpensive and easy to perform. In this study, we developed a portable, low-cost, and wearable sweat-glucose detection device for in situ detection. RESULTS: The sensor adopted an integrated biomimetic nanoenzyme of glucose oxidase (GOx) encapsulated in copper 1, 4-benzenedicarboxylate (CuBDC) (GOx@CuBDC) through a biomimetic mineralization process. CuBDC exhibited a peroxide-like effect, cascade catalytic effect with the encapsulated GOx, and increased the enzyme stability. GOx@CuBDC and 3,3,5,5-tetramethylbenzidine were combined to form a hybrid membrane that achieved single-step paper-based glucose detection. SIGNIFICANCE AND NOVELTY: This GOx@CuBDC-based colorimetric glucose sensor was used to quantitatively analyze the sweat-glucose concentration with smartphone readings. The sensor exhibited a good linear relationship over the concentration range of 40-900 µM and a limit of detection of 20.7 µM (S/N = 3). Moreover, the sensor performed well in situ monitoring and in evaluating variations based on the consumption of foods with different glycemic indices. Therefore, the fabricated wearable sweat-glucose sensors exhibited optimal practical application performance.


Asunto(s)
Técnicas Biosensibles , Colorimetría , Cobre , Glucosa Oxidasa , Glucosa , Teléfono Inteligente , Sudor , Glucosa Oxidasa/química , Glucosa Oxidasa/metabolismo , Cobre/química , Sudor/química , Humanos , Glucosa/análisis , Dispositivos Electrónicos Vestibles , Límite de Detección , Enzimas Inmovilizadas/química , Enzimas Inmovilizadas/metabolismo
10.
Anal Chim Acta ; 1316: 342874, 2024 Aug 08.
Artículo en Inglés | MEDLINE | ID: mdl-38969415

RESUMEN

BACKGROUND: The rapid development of micro-solid phase extraction (µ-SPE) procedures with new sorption materials, in particular, based on using natural materials, is currently reported. The production of these sorbents and the entire extraction procedure should support the implementation of Green Analytical Chemistry (GAC) principles. Promising materials are sorbents based on paper, which can be relatively easily modified, among others: by covering it with a polymer membrane. In this work, the practical application of paper-supported polystyrene used in the analysis of urine samples containing selected date-rape drugs (DRD) substances, and evaluation of the entire procedure using GAC metrics is presented. RESULTS: The paper-supported polystyrene membranes were successfully fabricated and characterized. The successful polystyrene coating on the paper was confirmed through ATR-FTIR measurements, ensuring even coverage. The µ-SPE procedure using this material facilitated extraction with a throughput of approximately 120 samples per hour in just a few steps. Throughout the research, a mixture of 100 mM acetic acid:methanol:acetonitrile (70:15:15, v/v/v) was selected as an optimal background electrolyte for capillary electrophoresis - mass spectrometry analysis. Validation results of this method demonstrated its suitability, exhibiting good linearity (R2 > 0.95), low limits of detection (3.1-15 ng mL-1), acceptable precision (<15 %), and recovery for all tested analytes. Furthermore, the greenness evaluation conducted with six different metrics: AGREEprep, AGREE, ComplexGAPI, SPMS, hexagonal metric, and WAC indicated the overall eco-friendliness and sustainability of the method, with minor concerns regarding energy consumption. SIGNIFICANCE: The use of cellulose paper with polystyrene membranes for µ-SPE provides a versatile and eco-friendly extraction method for detecting DRDs in urine samples. The presented work is an example of the use of GAC metrics in the evaluation of the analytical procedure. The optimized PT-µ-SPE/CE-MS method allows for minimized reagent usage and waste production. Moreover, the method proves to be sustainable and efficient for forensic toxicology analysis.


Asunto(s)
Papel , Poliestirenos , Microextracción en Fase Sólida , Poliestirenos/química , Humanos , Microextracción en Fase Sólida/métodos , Membranas Artificiales , Tecnología Química Verde , Límite de Detección , Drogas Ilícitas/orina , Drogas Ilícitas/aislamiento & purificación , Drogas Ilícitas/análisis
11.
Anal Chim Acta ; 1316: 342882, 2024 Aug 08.
Artículo en Inglés | MEDLINE | ID: mdl-38969418

RESUMEN

BACKGROUND: Transition metal phosphides with properties similar to platinum metal have received increasing attention for the non-enzymatic detection of glucose. However, the requirement of highly corrosive reagent during sample pretreatment would impose a potential risk to the human body, limiting their practical applications. RESULTS: In this study, we report a self-powered microfluidic device for the non-enzymatic detection of glucose using nickel phosphide (Ni2P) hybrid as the catalyst. The Ni2P hybrid is synthesized by pyrolysis of metal-organic framework (MOF)-based precursor and in-situ phosphating process, showing two linear detection ranges (1 µM-1 mM, 1 mM-6 mM) toward glucose with the detection limit of 0.32 µM. The good performance of Ni2P hybrid for glucose is attributed to the synergistic effect of Ni2P active sites and N-doped porous carbon matrix. The microchip is integrated with a NaOH-loaded paper pad and a capillary-based micropump, enabling the automatic NaOH redissolution and delivery of sample solution into the detection chamber. Under the optimized condition, the Ni2P hybrid-based microchip realized the detection of glucose in a user-friendly way. Besides, the feasibility of using this microchip for glucose detection in real serum samples has also been validated. SIGNIFICANCE: This article presents a facile fabrication method utilizing a MOF template to synthesize a Ni2P hybrid catalyst. By leveraging the synergy between the Ni2P active sites and the N-doped carbon matrix, an exceptional electrochemical detection performance for glucose has been achieved. Additionally, a self-powered chip device has been developed for convenient glucose detection based on the pre-established high pH environment on the chip.


Asunto(s)
Técnicas Electroquímicas , Electrodos , Níquel , Níquel/química , Técnicas Electroquímicas/instrumentación , Humanos , Glucosa/análisis , Fosfinas/química , Estructuras Metalorgánicas/química , Límite de Detección , Dispositivos Laboratorio en un Chip , Glucemia/análisis , Catálisis
12.
Anal Chim Acta ; 1316: 342820, 2024 Aug 08.
Artículo en Inglés | MEDLINE | ID: mdl-38969422

RESUMEN

This research presents an innovative reflective fiber optic probe structure, mutinously designed to detect H7N9 avian influenza virus gene precisely. This innovative structure skillfully combines multimode fiber (MMF) with a thin-diameter seven-core photonic crystal fiber (SCF-PCF), forming a semi-open Fabry-Pérot (FPI) cavity. This structure has demonstrated exceptional sensitivity in light intensity-refractive index (RI) response through rigorous theoretical and experimental validation. The development of a quasi-distributed parallel sensor array, which provides temperature compensation during measurements, has achieved a remarkable RI response sensitivity of up to 532.7 dB/RIU. The probe-type fiber optic sensitive unit, expertly functionalized with streptavidin, offers high specificity in detecting H7N9 avian influenza virus gene, with an impressively low detection limit of 10-2 pM. The development of this biosensor marks a significant development in biological detection, offering a practical engineering solution for achieving high sensitivity and specificity in light-intensity-modulated biosensing. Its potential for wide-ranging applications in various fields is now well-established.


Asunto(s)
Técnicas Biosensibles , Subtipo H7N9 del Virus de la Influenza A , Temperatura , Técnicas Biosensibles/métodos , Subtipo H7N9 del Virus de la Influenza A/genética , Subtipo H7N9 del Virus de la Influenza A/aislamiento & purificación , Fibras Ópticas , Límite de Detección , Tecnología de Fibra Óptica/métodos , Animales , Genes Virales
13.
Anal Chim Acta ; 1316: 342879, 2024 Aug 08.
Artículo en Inglés | MEDLINE | ID: mdl-38969416

RESUMEN

BACKGROUND: Chirality is a ubiquitous phenomenon in nature, but enantiomers exhibit different pharmacological activities and toxicological effects. Therefore, Chiral recognition plays a pivotal role in various fields such as life sciences, chemical synthesis, drug development, and materials science. The synthesis of novel chiral composites with well-defined loading capabilities and ordered structures holds significant potential for electrochemical chiral recognition applications. However, the design of selective and stable electrochemical chiral recognition materials remains a challenging task. RESULT: In this work, we construct a simple and rapid electrochemical sensing platform for tryptophan (Trp) enantiomer recognition using cyclodextrin-modified microporous organic network as chiral recognition agent. CD-MON with chiral microenvironment was prepared by Sonogashira-Hagihara coupling reaction of the chiral molecule heptyl-6-iodo-6-deoxyß-cyclodextrin and 1, 4-Diethynylbenzene. The adhesion of BSA makes CD-MON firmly fixed on the electrode surface, and as a chiral protein, it can improve the chiral recognition ability through synergistic effect. Chiral amino acids are in full contact with the chiral microenvironment during pore conduction of MON, and L-Trp is more stably bound to CD-MON/BSA due to steric hindrance, host-guest recognition and hydrogen bonding. Therefore, the electrochemical sensor can effectively identify tryptophan enantiomers (IL-Trp/ID-Trp = 2.02), and it exhibits a detection limit of 2.6 µM for L-Trp. UV-Vis spectroscopy confirmed the adsorption capacity of CD-MON towards tryptophan enantiomers in agreement with electrochemistry results. SIGNIFICANCE: The prepared chiral sensor has excellent stability, reproducibility (RSD = 3.7%) and selectivity, realizes the quantitative detection of single isomer in tryptophan racemic and quantitative analysis in real samples with 94.0%-101.0% recovery. This work represents the first application of MON in chiral electrochemistry which expands the application scope of chiral sensors and holds great significance in separation science and electrochemical sensing.


Asunto(s)
Ciclodextrinas , Técnicas Electroquímicas , Estereoisomerismo , Técnicas Electroquímicas/métodos , Ciclodextrinas/química , Porosidad , Triptófano/análisis , Triptófano/química , Aminoácidos/análisis , Aminoácidos/química , Límite de Detección , Animales , Electrodos , Albúmina Sérica Bovina/química
14.
Anal Chim Acta ; 1316: 342836, 2024 Aug 08.
Artículo en Inglés | MEDLINE | ID: mdl-38969426

RESUMEN

BACKGROUND: As promising biomarkers of diabetes, α-glucosidase (α-Glu) and ß-glucosidase (ß-Glu) play a crucial role in the diagnosis and management of diseases. However, there is a scarcity of techniques available for simultaneously and sensitively detecting both enzymes. What's more, most of the approaches for detecting α-Glu and ß-Glu rely on a single-mode readout, which can be affected by multiple factors leading to inaccurate results. Hence, the simultaneous detection of the activity levels of both enzymes in a single sample utilizing multiple-readout sensing approaches is highly attractive. RESULTS: In this work, we constructed a facile sensing platform for the simultaneous determination of α-Glu and ß-Glu by utilizing a luminescent covalent organic framework (COF) as a fluorescent indicator. The enzymatic hydrolysis product common to both enzymes, p-nitrophenol (PNP), was found to affect the fluorometric signal through an inner filter effect on COF, enhance the colorimetric response by intensifying the absorption peak at 400 nm, and induce changes in RGB values when analyzed using a smartphone-based color recognition application. By combining fluorometric/colorimetric measurements with smartphone-assisted RGB mode, we achieved sensitive and accurate quantification of α-Glu and ß-Glu. The limits of detection for α-Glu were determined to be 0.8, 1.22, and 1.85 U/L, respectively. Similarly, the limits of detection for ß-Glu were 0.16, 0.42, and 0.53 U/L, respectively. SIGNIFICANCE: Application of the proposed sensing platform to clinical serum samples revealed significant differences in the two enzymes between healthy people and diabetic patients. Additionally, the proposed sensing method was successfully applied for the screening of α-Glu inhibitors and ß-Glu inhibitors, demonstrating its viability and prospective applications in the clinical management of diabetes as well as the discovery of antidiabetic medications.


Asunto(s)
Inhibidores de Glicósido Hidrolasas , Estructuras Metalorgánicas , alfa-Glucosidasas , beta-Glucosidasa , Estructuras Metalorgánicas/química , Humanos , Inhibidores de Glicósido Hidrolasas/farmacología , Inhibidores de Glicósido Hidrolasas/química , beta-Glucosidasa/antagonistas & inhibidores , beta-Glucosidasa/metabolismo , alfa-Glucosidasas/metabolismo , alfa-Glucosidasas/sangre , Colorimetría/métodos , Límite de Detección , Nitrofenoles/metabolismo , Nitrofenoles/química , Nitrofenoles/análisis , Evaluación Preclínica de Medicamentos , Colorantes Fluorescentes/química
15.
Anal Chim Acta ; 1316: 342838, 2024 Aug 08.
Artículo en Inglés | MEDLINE | ID: mdl-38969428

RESUMEN

The diagnosis of dengue virus (DENV) has been challenging particularly in areas far from clinical laboratories. Early diagnosis of pathogens is a prerequisite for the timely treatment and pathogen control. An ideal diagnostic for viral infections should possess high sensitivity, specificity, and flexibility. In this study, we implemented dual amplification involving Cas13a and Cas12a, enabling sensitive and visually aided diagnostics for the dengue virus. Cas13a recognized the target RNA by crRNA and formed the assembly of the Cas13a/crRNA/RNA ternary complex, engaged in collateral cleavage of nearby crRNA of Cas12a. The Cas12a/crRNA/dsDNA activator ternary complex could not be assembled due to the absence of crRNA of Cas12a. Moreover, the probe, with 5' and 3' termini labeled with FAM and biotin, could not be separated. The probes labeled with FAM and biotin, combined the Anti-FAM and the Anti-Biotin Ab-coated gold nanoparticle, and conformed sandwich structure on the T-line. The red line on the paper strip caused by clumping of AuNPs on the T-line indicated the detection of dengue virus. This technique, utilizing an activated Cas13a system cleaving the crRNA of Cas12a, triggered a cascade that amplifies the virus signal, achieving a low detection limit of 190 fM with fluorescence. Moreover, even at 1 pM, the red color on the T-line was easily visible by naked eyes. The developed strategy, incorporating cascade enzymatic amplification, exhibited good sensitivity and may serve as a field-deployable diagnostic tool for dengue virus.


Asunto(s)
Virus del Dengue , Virus del Dengue/aislamiento & purificación , Dengue/diagnóstico , Humanos , Técnicas de Amplificación de Ácido Nucleico/métodos , ARN Viral/análisis , Proteínas Asociadas a CRISPR/metabolismo , Nanopartículas del Metal/química , Límite de Detección , Oro/química , Proteínas Bacterianas , Endodesoxirribonucleasas
16.
Anal Chim Acta ; 1316: 342821, 2024 Aug 08.
Artículo en Inglés | MEDLINE | ID: mdl-38969423

RESUMEN

The monitoring of biomarkers in wound exudate is of great importance for wound care and treatment, and electrochemical biosensors with high sensitivity are potentially useful for this purpose. However, conventional electrochemical biosensors always suffer from severe biofouling when performed in the complex wound exudate. Herein, an antifouling electrochemical biosensor for the detection of involucrin in wound exudate was developed based on a wound dressing, oxidized bacterial cellulose (OxBC) and quaternized chitosan (QCS) composite hydrogel. The OxBC/QCS hydrogel was prepared using an in-situ chemical oxidation and physical blending method, and the proportion of OxBC and QCS was optimized to achieve electrical neutrality and enhanced hydrophilicity, therefore endowing the hydrogel with exceptional antifouling and antimicrobial properties. The involucrin antibody SY5 was covalently bound to the OxBC/QCS hydrogel to construct the biosensor, and it demonstrated a low limit of detection down to 0.45 pg mL-1 and a linear detection range from 1.0 pg mL-1 to 1.0 µg mL-1, and it was capable of detecting targets in wound exudate. Crucially, the unique antifouling and antimicrobial capability of the OxBC/QCS hydrogel not only extends its effective lifespan but also guarantees the sensing performance of the biosensor. The successful application of this wound dressing, OxBC/QCS hydrogel for involucrin detection in wound exudate demonstrates its promising potential in wound healing monitoring.


Asunto(s)
Técnicas Biosensibles , Celulosa , Quitosano , Técnicas Electroquímicas , Oxidación-Reducción , Quitosano/química , Celulosa/química , Incrustaciones Biológicas/prevención & control , Humanos , Hidrogeles/química , Exudados y Transudados/química , Límite de Detección
17.
Anal Chim Acta ; 1316: 342873, 2024 Aug 08.
Artículo en Inglés | MEDLINE | ID: mdl-38969432

RESUMEN

BACKGROUND: DNA walker-based strategies have gained significant attention in nucleic acid analysis. However, they face challenges related to balancing design complexity, sequence dependence, and amplification efficiency. Furthermore, most existing DNA walkers rely on walking and lock probes, requiring optimization of various parameters like DNA probe sequence, walking-to-lock probe ratio, lock probe length, etc. to achieve optimal performance. This optimization process is time-consuming and adds complexity to experiments. To enhance the performance and reliability of DNA walker nanomachines, there is a need for a simpler, highly sensitive, and selective alternative strategy. RESULTS: A sensitive and rapid miRNA analysis strategy named hairpin-shaped DNA aligner and nicking endonuclease-fueled DNA walker (HDA-NE DNA walker) was developed. The HDA-NE DNA walker was constructed by modifying hairpin-shaped DNA aligner (HDA) probe and substrate report (SR) probe on the surface of AuNPs. Under normal conditions, HDA and SR remained stable. However, in the presence of miR-373, HDA underwent a conformational transition to an activated structure to continuously cleave the SR probe on the AuNPs with the assistance of Nt.AlwI nicking endonuclease, resulting in sensitive miRNA detection with a detection limit as low as 0.23 pM. Additionally, the proposed HDA-NE DNA walker exhibited high selectivity in distinguishing miRNAs with single base differences and can effectively analyze miR-373 levels in both normal and breast cancer patient serums. SIGNIFICANCE: The proposed HDA-NE DNA walker system was activated by a conformational change of HDA probe only in the presence of the target miRNA, eliminating the need for a lock probe and without sequence dependence for SR probe. This strategy demonstrated a rapid reaction rate of only 30 min, minimal background noise, and a high signal-to-noise ratio (S/B) compared to capture/lock-based DNA walker. The method is expected to become a powerful tool and play an important role in disease diagnosis and precision therapy.


Asunto(s)
ADN , MicroARNs , MicroARNs/sangre , MicroARNs/análisis , Humanos , ADN/química , Límite de Detección , Técnicas Biosensibles/métodos , Oro/química , Nanopartículas del Metal/química , Sondas de ADN/química , Sondas de ADN/genética , Endonucleasas/metabolismo , Endonucleasas/química , Secuencias Invertidas Repetidas
18.
Anal Chim Acta ; 1316: 342837, 2024 Aug 08.
Artículo en Inglés | MEDLINE | ID: mdl-38969427

RESUMEN

Monitoring the levels of L-Tryptophan (L-Trp) in body fluids is crucial due to its significant role in metabolism and protein synthesis, which ultimately affects neurological health. Herein, we have developed a novel magneto-responsive electrochemical enantioselective sensor for the recognition of L-Trp based on oriented biochar derived from Loofah, Fe3O4 nanoparticles, and molecularly imprinted polydopamine (MIPDA) in xanthan hydrogel. The successful synthesis of these materials has been confirmed through physicochemical and electrochemical characterization. Various operational factors such as pH, response time, loading sample volume, and loading of active materials were optimized. As a result, the sensor exhibited an affordable linear range of 1.0-60.0 µM, with a desirable limit of detection of 0.44 µM. Furthermore, the proposed electrochemical sensor demonstrated good reproducibility and desirable selectivity for the determination of L-Trp, making it suitable for analyzing L-Trp levels in human plasma and serum samples. The development presented offers an appealing, easily accessible, and efficient strategy. It utilizes xanthan hydrogel to improve mass transfer and adhesion, biochar-stabilized Fe3O4 to facilitate magnetic orientation and accelerate mass transfer and sensitivity, and polydopamine MIP to enhance selectivity. This approach enables on-site evaluation of L-Trp levels, which holds significant value for healthcare monitoring and early detection of related conditions.


Asunto(s)
Técnicas Electroquímicas , Hidrogeles , Polisacáridos Bacterianos , Triptófano , Triptófano/química , Triptófano/sangre , Polisacáridos Bacterianos/química , Hidrogeles/química , Estereoisomerismo , Humanos , Impresión Molecular , Polímeros/química , Polímeros Impresos Molecularmente/química , Indoles/química , Biopolímeros/química , Límite de Detección , Nanopartículas de Magnetita/química
19.
Anal Chim Acta ; 1316: 342876, 2024 Aug 08.
Artículo en Inglés | MEDLINE | ID: mdl-38969434

RESUMEN

BACKGROUND: Ofloxacin (OFL) is often abused in medicine and animal husbandry, which poses a great threat to human health and ecological environment. Therefore, it is necessary to establish efficient method to detect OFL. Electrochemical sensor has attracted widespread attention due to the advantages of low cost and fast response. However, most electrochemical sensors usually use one response signal to detect the target, which makes it sensitive to the variable background noise in the complex environment, resulting in low robustness and selectivity. The ratio detection mode and employing molecularly imprinted polymer (MIP) are two strategies to solve these problems. RESULTS: A novel molecular imprinting polymer-ratiometric electrochemical sensor (MIP-RECS) based on Fe-MOF-NH2/CNTs-NH2/MXene composite was prepared for the rapid and sensitive detection of OFL. The positively charged Fe-MOF-NH2 and CNTs-NH2 as interlayer spacers were introduced into the negatively charged MXene through a simple electrostatic self-assembly technique, which effectively prevented the agglomeration of MXene and increased the electrocatalytic activity. A glass carbon electrode was modified by the composite and a MIP film was electropolymerized on it using o-phenylenediamine and ß-cyclodextrin as bifunctional monomers and OFL as template. Then a MIP-RECS was designed by adding dopamine (DA) into the electrolyte solution as internal reference, and OFL was quantified by the response current ratio of OFL to DA. The current ratio and the concentration of OFL displayed a satisfying linear relationship in the range of 0.1 µM-100 µM, with a limit of detection (LOD) of 13.2 nM. SIGNIFICANCE: Combining molecular imprinting strategy and ratio strategy, the MIP-RECS has impressive selectivity compared with the non-imprinted polymer-RECS, and has better repeatability and reproducibility than non-ratiometric sensor. The MIP-RECS has high sensitivity and accuracy, which was applied for the detection of OFL in four different brands of milk and was verified by HPLC method with satisfactory results.


Asunto(s)
Técnicas Electroquímicas , Estructuras Metalorgánicas , Polímeros Impresos Molecularmente , Ofloxacino , Ofloxacino/análisis , Ofloxacino/química , Técnicas Electroquímicas/métodos , Polímeros Impresos Molecularmente/química , Estructuras Metalorgánicas/química , Nanotubos de Carbono/química , Hierro/química , Hierro/análisis , Límite de Detección , Impresión Molecular , Animales , Electrodos , Leche/química
20.
Anal Chim Acta ; 1316: 342800, 2024 Aug 08.
Artículo en Inglés | MEDLINE | ID: mdl-38969435

RESUMEN

Heavy metal pollution in the environment has become a significant global concern due to its detrimental effects on human health and the environment. In this study, we report an electrochemical aptasensor for the simultaneous detection of Hg2+ and Pb2+. Gold nanoflower/polyethyleneimine-reduced graphene oxide (AuNFs/PEI-rGO) was introduced on the surface of a gold electrode to improve sensing performance. The aptasensor is based on the formation of a T-Hg2+-T mismatch structure and specific cleavage of the Pb2+-dependent DNAzyme, resulting in a dual signal generated by the Exo III specific digestion of methylene blue (MB) labeled at the 3' end of probe DNA-1 and the reduction of the substrate ascorbic acid (AA) catalyzed by the signal label. The decrease of MB signal and the increase of AA oxidation peak was used to indicate the content of Hg2+ and Pb2+, respectively, with detection limits of 0.11 pM (Hg2+) and 0.093 pM (Pb2+). The aptasensor was also used for detecting Hg2+ and Pb2+ in water samples with good recoveries. Overall, this electrochemical aptasensor shows promising potential for sensitive and selective detection of heavy metals in environmental samples.


Asunto(s)
Aptámeros de Nucleótidos , Técnicas Biosensibles , Técnicas Electroquímicas , Exodesoxirribonucleasas , Plomo , Mercurio , Estructuras Metalorgánicas , Contaminantes Químicos del Agua , Mercurio/análisis , Plomo/análisis , Plomo/química , Estructuras Metalorgánicas/química , Aptámeros de Nucleótidos/química , Exodesoxirribonucleasas/química , Exodesoxirribonucleasas/metabolismo , Contaminantes Químicos del Agua/análisis , Técnicas Biosensibles/métodos , Grafito/química , Oro/química , Límite de Detección , Electrodos , ADN Catalítico/química
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...