Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 154
Filtrar
1.
Cont Lens Anterior Eye ; 47(4): 102155, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38609792

RESUMEN

Presbyopia is often the first sign of ageing experienced by humans. Standardising terminology and adopting it across the BCLA CLEAR Presbyopia reports, improves consistency in the communication of the evidence-based understanding of this universal physiological process. Presbyopia can be functionally and psychologically debilitating, especially for those with poor access to eyecare. Presbyopia was defined as occurring when the physiologically normal age-related reduction in the eye's focusing range reaches a point that, when optimally corrected for far vision, the clarity of vision at near is insufficient to satisfy an individual's requirements. Accommodation is the change in optical power of the eye due to a change in crystalline lens shape and position, whereas pseudo-accommodation is the attainment of functional near vision in an emmetropic or far-corrected eye without changing the refractive power of the eye. Other definitions specific to vision and lenses for presbyopia were also defined. It is recommended that these definitions be consistently adopted in order to standardise future research, clinical evaluations and education.


Asunto(s)
Acomodación Ocular , Presbiopía , Terminología como Asunto , Presbiopía/fisiopatología , Presbiopía/terapia , Presbiopía/diagnóstico , Humanos , Acomodación Ocular/fisiología , Refracción Ocular/fisiología , Agudeza Visual/fisiología , Anteojos
2.
Cont Lens Anterior Eye ; 47(4): 102156, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38641525

RESUMEN

It is important to be able to measure the range of clear focus in clinical practice to advise on presbyopia correction techniques and to optimise the correction power. Both subjective and objective techniques are necessary: subjective techniques (such as patient reported outcome questionnaires and defocus curves) assess the impact of presbyopia on a patient and how the combination of residual objective accommodation and their natural DoF work for them; objective techniques (such as autorefraction, corneal topography and lens imaging) allow the clinician to understand how well a technique is working optically and whether it is the right choice or how adjustments can be made to optimise performance. Techniques to assess visual performance and adverse effects must be carefully conducted to gain a reliable end-point, considering the target size, contrast and illumination. Objective techniques are generally more reliable, can help to explain unexpected subjective results and imaging can be a powerful communication tool with patients. A clear diagnosis, excluding factors such as binocular vision issues or digital eye strain that can also cause similar symptoms, is critical for the patient to understand and adapt to presbyopia. Some corrective options are more permanent, such as implanted inlays / intraocular lenses or laser refractive surgery, so the optics can be trialled with contact lenses in advance (including differences between the eyes) to better communicate with the patient how the optics will work for them so they can make an informed choice.


Asunto(s)
Presbiopía , Presbiopía/diagnóstico , Presbiopía/fisiopatología , Presbiopía/terapia , Humanos , Lentes de Contacto , Acomodación Ocular/fisiología , Topografía de la Córnea , Agudeza Visual/fisiología , Refracción Ocular/fisiología , Anteojos
3.
J Patient Rep Outcomes ; 8(1): 41, 2024 Apr 09.
Artículo en Inglés | MEDLINE | ID: mdl-38592339

RESUMEN

BACKGROUND: The Near Visual Acuity Questionnaire Presbyopia (NAVQ-P) is a patient-reported outcome (PRO) measure that was developed in a phakic presbyopia population to assess near vision function impacts. The study refined and explored the psychometric properties and score interpretability of the NAVQ-P and additional PRO items assessing near vision correction independence (NVCI), near vision satisfaction (NVS), and near vision correction preference (NVCP). METHODS: This was a psychometric validation study conducted using PRO data collected as part of a Phase IIb clinical trial (CUN8R44 A2202) consisting of 235 randomized adults with presbyopia from the US, Japan, Australia, and Canada. Data collected at baseline, week 2, and months 1, 2, and 3 during the 3-month trial treatment period were included in the analyses to assess item (question) properties, NAVQ-P dimensionality and scoring, reliability, validity, and score interpretation. RESULTS: Item responses were distributed across the full response scale for most NAVQ-P and additional PRO items. Confirmatory factor analysis supported the pre-defined unidimensional structure and calculation of a NAVQ-P total score as a measure of near vision function. Item deletion informed by item response distributions, dimensionality analyses, item response theory, and previous qualitative findings, including clinical input, supported retention of 14 NAVQ-P items. The 14-item NAVQ-P total score had excellent internal consistency (α = 0.979) and high test-retest reliability (Intraclass Correlation Coefficients > = 0.898). There was good evidence of construct-related validity for all PROs supported by strong correlations with concurrent measures. Excellent results for known-groups validity and ability to detect change analyses were also demonstrated. Anchor-based and distribution-based methods supported interpretation of scores through generation of group-level and within-individual estimates of meaningful change thresholds. A meaningful within-patient change in the range of 8-15-point improvement on the NAVQ-P total score (score range 0-42) was recommended, including a more specific responder definition of 10-point improvement. CONCLUSIONS: The NAVQ-P, NVCI, and NVS are valid and reliable instruments which have the ability to detect change over time. Findings strongly support the use of these measures as outcome assessments in clinical/research studies and in clinical practice in the presbyopia population.


Asunto(s)
Miopía , Presbiopía , Adulto , Humanos , Australia , Medición de Resultados Informados por el Paciente , Presbiopía/diagnóstico , Psicometría , Reproducibilidad de los Resultados
4.
J Patient Rep Outcomes ; 8(1): 16, 2024 Feb 08.
Artículo en Inglés | MEDLINE | ID: mdl-38329635

RESUMEN

BACKGROUND: Presbyopia is an age-related condition that causes a decreased ability to focus on nearby objects. Multifocal contact lenses are commonly used to address this issue. However, there seems to be a notable dissatisfaction among multifocal contact lens wearers. The absence of a reliable instrument to measure the patient's perspective, despite the widespread use of this method, highlights the need for further research in this area. OBJECTIVE: The objective of this study is to develop an item-bank integrating all domains necessary to assess the patient's perspective on multifocal contact lens performance, offering a comprehensive measure. The item-bank will ensure a high level of content validity, be self-administered, and will initially be available in Spanish. The aim of this tool is to serve as a valuable resource for research and optometric clinics, facilitating the follow-up of patients with presbyopia who wear multifocal contact lenses or those who are newly starting to use them. METHODOLOGY: The MCL-PRO item bank, followed a systematic and step-wise inductive approach to gather information, following the recommendations outlined in the COSMIN guidelines and similar studies. The process involved the following steps: (1) Literature review and relevant existing items identification (2) Social media review, (3) Semi-structured focus groups, (4) performing qualitative analysis, (5) refining and revising the items, and (6) generating the content of the item bank. RESULTS: A total of 575 items were included in the item-bank hosted under 8 different domains that were found to be important for presbyopic population: visual symptoms (213), activity limitation (111), ocular symptoms (135), convenience (36), emotional well-being (33), general symptoms (16), cognitive issues (21) and economic issues (10). CONCLUSION: The item-bank created has followed standardised methodology for its development and encloses all the aspects for MCL performance evaluation from patients perspective.


Asunto(s)
Lentes de Contacto , Presbiopía , Humanos , Presbiopía/diagnóstico , Visión Ocular , Grupos Focales , Ojo
5.
BMC Ophthalmol ; 23(1): 487, 2023 Nov 27.
Artículo en Inglés | MEDLINE | ID: mdl-38012552

RESUMEN

PURPOSE: By comparing the results of the new self-contained darkroom refractive screener (YD-SX-A) versus table-top autorefractor and cycloplegic retinoscopy, to evaluate the performance of the YD-SX-A in detecting refractive error in children and adolescents and then judge whether it can be used in refractive screening. METHODS: Cross-sectional study. 1000 participants between the ages of 6 and 18 who visited the Optometry Center of the People's Hospital of Guangxi Zhuang Autonomous Region from June to December 2022 were selected. First, participants were instructed to measure their diopter with a table-top autorefractor (Topcon KR8800) and YD-SX-A in a noncycloplegic setting. After cycloplegia, they were retinoscopy by a professional optometrist. The results measured by three methods were collected respectively. To avoid deviation, only the right eye (1000 eyes) data were used in the statistical analysis. The Bland-Altman plots were used to evaluate the agreement of diopters measured by the three methods. The receiver operating characteristic (ROC) curves was used to analysis effectiveness of detecting refractive error of YD-SX-A. RESULTS: The average age of participants was 10.77 ± 3.00 years, including 504 boys (50.4%) and 496 girls (49.6%). When YD-SX-A and cycloplegia retinoscopy (CR) were compared in the myopia group, there was no statistical difference in spherical equivalent (SE) (P > 0.05), but there was a statistical difference in diopter spherical (DS) and diopter cylinder (DC) (P < 0.05). Comparing the diopter results of Topcon KR8800 and CR, the difference between each test value in the myopia group was statistically significant (P < 0.05). In the hyperopia group, the comparison between YD-SX-A and CR showed no statistically significant differences in the DC (P > 0.05), but there were significant differences in the SE and DS (P < 0.05). In the astigmatism group, the SE, DS, and DC were statistically different, and the DC of YD-SX-A was lower than that of CR and Topcon KR8800. Bland-Altman plots indicated that YD-SX-A has a moderate agreement with CR and Topcon KR8800. The sensitivity and specificity of YD-SX-A for detecting myopia, hyperopia and astigmatism were 90.17% and 90.32%, 97.78% and 87.88%, 84.08% and 74.26%, respectively. CONCLUSION: This study has identified that YD-SX-A has shown good performance in both agreement and effectiveness in detecting refractive error when compared with Topcon KR8800 and CR. YD-SX-A could be a useful tool for large-scale population refractive screening.


Asunto(s)
Trastornos de la Pupila , Errores de Refracción , Retinoscopía , Selección Visual , Adolescente , Niño , Femenino , Humanos , Masculino , Astigmatismo/diagnóstico , China/epidemiología , Estudios Transversales , Hiperopía/diagnóstico , Miopía/diagnóstico , Optometría , Presbiopía/diagnóstico , Trastornos de la Pupila/diagnóstico , Trastornos de la Pupila/epidemiología , Refracción Ocular , Errores de Refracción/diagnóstico , Errores de Refracción/epidemiología , Retinoscopía/métodos , Selección Visual/métodos
7.
BMJ Open Ophthalmol ; 8(1)2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-37278419

RESUMEN

Presbyopia occurs when the physiologically normal age-related reduction in the eyes focusing range reaches a point, when optimally corrected for distance vision, that the clarity of vision at near is insufficient to satisfy an individual's requirements. Hence, it is more about the impact it has on an individual's visual ability to function in their environment to maintain their lifestyle than a measured loss of focusing ability. Presbyopia has a significant impact on an individual's quality of life and emotional state. While a range of amelioration strategies exist, they are often difficult to access in the developing world and prescribing is generally not optimal even in developed countries. This review identified the need for a standardised definition of presbyopia to be adopted. An appropriate battery of tests should be applied in evaluating presbyopic management options and the results of clinical trials should be published (even if unsuccessful) to accelerate the provision of better outcomes for presbyopes.


Asunto(s)
Presbiopía , Humanos , Presbiopía/diagnóstico , Calidad de Vida , Ojo , Suministros de Energía Eléctrica
8.
Graefes Arch Clin Exp Ophthalmol ; 261(7): 1923-1932, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-36826601

RESUMEN

PURPOSE: To investigate whether fundus autofluorescence (FAF) obtained using an ultra-wide field (UWF) fundus camera with an artificial opacity pattern can grade the degree of presbyopia and nuclear cataract. METHODS: Sixty eyes of 30 patients were enrolled in this prospective diagnostic study. The nuclear cataract (nuclear color/opalescence (NC/NO)) was graded according to the Lens Opacity Classification System III. The monocular near point of accommodation (NPA) was measured in eyes with NC3/NO3 or less. The mean gray value difference between the central 8 artificial opacity lesions and peripheral 8 artificial opacity lesions in the retinal AF was measured. The correlation between the mean gray value difference, NPA, and nuclear cataract grade was analyzed. RESULTS: The mean nuclear cataract grade of 60 eyes was 3.2 ± 1.6 and mean NPA of 37 eyes was 45.3 ± 16.1 cm. The mean gray value differences increased with increasing nuclear cataract grade (eyes with NC/NO grade 1, 53.3 ± 11.4; 2, 78.3 ± 13.6; 3, 95.2 ± 12.2; 4, 101.6 ± 11.9; 5, 109.0 ± 22.9; and 6, 121.1 ± 12.0; p < 0.001). The mean gray value difference was positively correlated with both the monocular NPA (R2 = 0.637; ß coefficient = 1.009; 95% CI, 0.748 to 1.271; p < 0.001) and nuclear cataract grade (R2 = 0.661; ß coefficient = 12.437; 95% CI, 10.097 to 14.778; p < 0.001). CONCLUSIONS: The FAF camera with an artificial opacity pattern attached can be used to effectively diagnose the degree of presbyopia and nuclear cataract.


Asunto(s)
Catarata , Cristalino , Presbiopía , Humanos , Presbiopía/diagnóstico , Estudios Prospectivos , Cristalino/diagnóstico por imagen , Cristalino/patología , Catarata/diagnóstico , Catarata/patología , Tecnología
10.
Jpn J Ophthalmol ; 65(5): 724-730, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-34374906

RESUMEN

PURPOSE: To investigate the prevalence and factors associated with uncorrected presbyopia among rural community dwellers in Japan. STUDY DESIGN: A population-based cross-sectional study was conducted in 2011 among community dwellers aged 40-74 years who received specific health checkups in Minamiaizu and Tadami, Fukushima Prefecture, Japan. METHODS: Uncorrected presbyopia was considered as when the distance-corrected visual acuity in the better eye was ≥0.5 and the near-presenting visual acuity in the better eye was <0.4, regardless of distance refractive status. Multiple logistic regression analysis was employed to calculate the odds ratios (ORs) for uncorrected presbyopia and to adjust for possible confounders. RESULTS: A total of 2054 individuals participated in the specific health checkups. In the 1156 individuals (response rate: 56.28%) analyzed in the study, the mean (SD) age was 63.0 (8.7) years, the percentage of women was higher (57.87%), and the prevalence of uncorrected presbyopia was 26.38% (95% CI 23.86%-29.03%). Multivariate analysis revealed that the factors associated with uncorrected presbyopia were older age (adjusted OR: 1.054 [95% CI: 1.034-1.075]), female sex (adjusted OR: 1.388 [95% CI: 1.006-1.915]), and distance-presenting vision impairment (adjusted OR: 2.651 [95% CI: 1.697-4.143]). CONCLUSION: Approximately one-quarter of the participants in this study from a rural population of Japan did not have adequate near vision. It is recommended that a public health intervention should be enacted to correct presbyopia, especially in the older age group, women, and those with uncorrected refractive errors.


Asunto(s)
Presbiopía , Población Rural , Anciano , Estudios de Cohortes , Estudios Transversales , Anteojos , Femenino , Humanos , Japón/epidemiología , Persona de Mediana Edad , Evaluación de Resultado en la Atención de Salud , Presbiopía/diagnóstico , Presbiopía/epidemiología , Prevalencia
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA