Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
J Prosthodont ; 22(7): 556-560, 2013 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-23387934

RESUMEN

PURPOSE: Edentulism has been decreasing in the US elderly population; however, due to the increasing number of elderly, the need for prostheses has been projected to rise over the next several decades. One of the aims of the Puerto Rican Elderly Dental Health Study (PREDHS) was to assess the quality of removable prostheses (RP) in the Puerto Rican (PR) elderly (>69 years of age) population. METHODS: A cross-sectional design, using a subgroup from the Puerto Rican Elderly: Health Conditions (PREHCO) study of dentate, community-dwelling older adults from the greater San Juan area was employed. Eligible participants were administered structured questionnaires and examined in their homes by three trained and calibrated dentists using National Institute of Dental and Craniofacial Research (NIDCR) criteria. RESULTS: One hundred and eighty three (183) participants were examined (61 males, 122 females) (p < 0.001). Overall, 64% were found to have a prosthetic problem with no statistical difference between genders. Unadjusted and age-adjusted logistic models were employed. Increasing age was associated with both upper and lower clinically defined abraded prostheses, (p = 0.007; p = 0.041, respectively). Maxillary (23%) and mandibular (27%) prostheses needed replacement due to deficiencies. CONCLUSION: RP deficiencies were found in almost two-thirds of a representative sample of dentate 70+ year-old people residing in PR. There was no difference in the proportion of deficiencies between elderly who reported a dental visit in the preceding year or not having seen a dentist. A quarter of the prostheses required replacement. The findings from this and the NHANES studies demonstrate that an engaged and recognized prosthodontic dental school faculty continues to be as important now as it was a generation ago.


Asunto(s)
Dentadura Parcial Removible/normas , Vida Independiente , Factores de Edad , Anciano , Anciano de 80 o más Años , Estudios Transversales , Abrazadera Dental/normas , Fracaso de la Restauración Dental/estadística & datos numéricos , Alisadura de la Restauración Dental/estadística & datos numéricos , Rebasado de Dentaduras/estadística & datos numéricos , Retención de Dentadura/normas , Femenino , Evaluación Geriátrica , Humanos , Masculino , Puerto Rico , Retratamiento/estadística & datos numéricos , Salud Urbana
2.
Gen Dent ; 60(2): 122-7; quiz 128-9, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-22414505

RESUMEN

The aim of this study was to evaluate the precision of three different mold filling techniques in order to obtain a cast simulating a three-unit, implant-retained, fixed prosthesis. Thirty casts (n = 10) were obtained using three different mold filling techniques. Group 1 used a unique fulfillment technique, Group 2 used a two-step fulfillment technique, and Group 3 used a latex cylinder technique. Using a metallic matrix, a titanium substructure was created to simulate a three-unit fixed prosthesis used as reference to evaluate the marginal misfit and tension forces in each cast. The vertical misfit was measured by an optical microscope with an increase of 120X and by an analysis unit using the one-screw test. The tension was quantified using strain gauges. The strain results showed a statistical difference between Group 3 and the other groups. The Tukey test showed no difference between the different treatment groups (p = 0.05). All three techniques were deemed efficient; however, considering that the cylinder latex technique induced less force toward the implants, it is the preferable technique for daily clinical practice.


Asunto(s)
Técnica de Colado Dental/normas , Prótesis Dental de Soporte Implantado/normas , Retención de Dentadura/normas , Dentadura Parcial Fija/normas , Sulfato de Calcio/química , Revestimiento para Colado Dental/química , Técnica de Colado Dental/instrumentación , Materiales de Impresión Dental/química , Técnica de Impresión Dental/instrumentación , Adaptación Marginal Dental/normas , Materiales Dentales/química , Diseño de Dentadura , Humanos , Ensayo de Materiales , Modelos Dentales , Estrés Mecánico , Propiedades de Superficie , Titanio/química
3.
Braz Oral Res ; 22(1): 43-7, 2008.
Artículo en Inglés | MEDLINE | ID: mdl-18425244

RESUMEN

Cyanocrylates have been widely used in the medical and dental fields for several years. In Dentistry, cyanoacrylates have been used for suturing, pulp capping, as retrofilling material in endodontic surgeries, and as cervical plug for pulpless teeth bleaching. The biocompatibility of these adhesives has been the topic of many researches and subcutaneous implantation is an effective methodology for these studies. The present study evaluated the biocompatibility of three different cyanoacrylate-based adhesives. Thirty-six Wistar rats were used, divided into four groups of 9 animals each: A (control)--distilled water, B--cyanoacrylate ester (Super Bonder), C - n-butyl-cyanoacrylate (Histoacryl) and D--alpha-cyanoacrylate (Three Bond). The materials were dispensed in sponges of polyvinyl chloride, the animals were incised and the sponges were inserted in the subcutaneous tissue and sutured. Each group was sub-divided according to the time of sacrifice of the animals: 7, 21 and 45 days. Subjective analysis of the histologic material showed that all groups presented some degree of irritability, but the inflammatory reaction decreased with the experimental time in all groups. Group D showed an inflammatory reaction which was closer to that of the control group and was considered to have good biocompatibility. Groups B and C were similar and presented more aggressive inflammatory reactions when compared to the control group. Based on the results, it was concluded that alpha-cyanoacrylate (Three Bond) was the most biocompatible adhesive because it caused the lowest levels of inflammation.


Asunto(s)
Adhesivos/efectos adversos , Materiales Biocompatibles/efectos adversos , Cianoacrilatos/efectos adversos , Retención de Dentadura/normas , Materiales de Obturación del Conducto Radicular/efectos adversos , Tejido Subcutáneo , Animales , Materiales Biocompatibles/normas , Evaluación Preclínica de Medicamentos , Inflamación/etiología , Inflamación/patología , Prótesis e Implantes/efectos adversos , Ratas , Ratas Wistar , Obturación Retrógrada , Tejido Subcutáneo/patología
4.
Braz. oral res ; 22(1): 43-47, Jan.-Mar. 2008. ilus, tab
Artículo en Inglés | LILACS | ID: lil-480582

RESUMEN

Cyanocrylates have been widely used in the medical and dental fields for several years. In Dentistry, cyanoacrylates have been used for suturing, pulp capping, as retrofilling material in endodontic surgeries, and as cervical plug for pulpless teeth bleaching. The biocompatibility of these adhesives has been the topic of many researches and subcutaneous implantation is an effective methodology for these studies. The present study evaluated the biocompatibility of three different cyanoacrylate-based adhesives. Thirty-six Wistar rats were used, divided into four groups of 9 animals each: A (control) - distilled water, B - cyanoacrylate ester (Super Bonder), C - n-butyl-cyanoacrylate (Histoacryl) and D - alpha-cyanoacrylate (Three Bond). The materials were dispensed in sponges of polyvinyl chloride, the animals were incised and the sponges were inserted in the subcutaneous tissue and sutured. Each group was sub-divided according to the time of sacrifice of the animals: 7, 21 and 45 days. Subjective analysis of the histologic material showed that all groups presented some degree of irritability, but the inflammatory reaction decreased with the experimental time in all groups. Group D showed an inflammatory reaction which was closer to that of the control group and was considered to have good biocompatibility. Groups B and C were similar and presented more aggressive inflammatory reactions when compared to the control group. Based on the results, it was concluded that alpha-cyanoacrylate (Three Bond) was the most biocompatible adhesive because it caused the lowest levels of inflammation.


Asunto(s)
Animales , Ratas , Adhesivos/efectos adversos , Materiales Biocompatibles/efectos adversos , Cianoacrilatos/efectos adversos , Retención de Dentadura/normas , Materiales de Obturación del Conducto Radicular/efectos adversos , Tejido Subcutáneo , Materiales Biocompatibles/normas , Evaluación Preclínica de Medicamentos , Inflamación/etiología , Inflamación/patología , Prótesis e Implantes/efectos adversos , Ratas Wistar , Obturación Retrógrada , Tejido Subcutáneo/patología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA