Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Neurology ; 94(16): e1684-e1692, 2020 04 21.
Artículo en Inglés | MEDLINE | ID: mdl-32269116

RESUMEN

OBJECTIVE: To validate quantitative diffusion-weighted imaging (DWI) MRI thresholds that correlate with poor outcome in comatose cardiac arrest survivors, we conducted a clinician-blinded study and prospectively obtained MRIs from comatose patients after cardiac arrest. METHODS: Consecutive comatose post-cardiac arrest adult patients were prospectively enrolled. MRIs obtained within 7 days after arrest were evaluated. The clinical team was blinded to the DWI MRI results and followed a prescribed prognostication algorithm. Apparent diffusion coefficient (ADC) values and thresholds differentiating good and poor outcome were analyzed. Poor outcome was defined as a Glasgow Outcome Scale score of ≤2 at 6 months after arrest. RESULTS: Ninety-seven patients were included, and 75 patients (77%) had MRIs. In 51 patients with MRI completed by postarrest day 7, the prespecified threshold of >10% of brain tissue with an ADC <650 ×10-6 mm2/s was highly predictive for poor outcome with a sensitivity of 0.63 (95% confidence interval [CI] 0.42-0.80), a specificity of 0.96 (95% CI 0.77-0.998), and a positive predictive value (PPV) of 0.94 (95% CI 0.71-0.997). The mean whole-brain ADC was higher among patients with good outcomes. Receiver operating characteristic curve analysis showed that ADC <650 ×10-6 mm2/s had an area under the curve of 0.79 (95% CI 0.65-0.93, p < 0.001). Quantitative DWI MRI data improved prognostication of both good and poor outcomes. CONCLUSIONS: This prospective, clinician-blinded study validates previous research showing that an ADC <650 ×10-6 mm2/s in >10% of brain tissue in an MRI obtained by postarrest day 7 is highly specific for poor outcome in comatose patients after cardiac arrest.


Asunto(s)
Encéfalo/diagnóstico por imagen , Coma/diagnóstico por imagen , Paro Cardíaco/terapia , Hipoxia-Isquemia Encefálica/diagnóstico por imagen , Síndrome de Paro Post-Cardíaco/diagnóstico por imagen , Adulto , Anciano , Coma/etiología , Imagen de Difusión por Resonancia Magnética , Femenino , Escala de Consecuencias de Glasgow , Paro Cardíaco/complicaciones , Humanos , Hipoxia-Isquemia Encefálica/etiología , Masculino , Persona de Mediana Edad , Síndrome de Paro Post-Cardíaco/complicaciones , Pronóstico , Estudios Prospectivos
2.
Med Intensiva (Engl Ed) ; 44(1): 1-8, 2020.
Artículo en Inglés, Español | MEDLINE | ID: mdl-30270144

RESUMEN

OBJECTIVE: To evaluate the feasibility of using the Sentinella® portable gamma-camera for the diagnosis of brain death (BD). DESIGN: A prospective, observational feasibility study was carried out. SETTING: Intensive Care Unit of a third level hospital. PATIENTS: Consecutive recording was made of the adults diagnosed with brain death based on clinical criteria following admission to the Intensive Care Unit in the period from January to December 2017. INTERVENTIONS: The procedure was performed at the patient bedside with the intravenous administration of technetium 99 metastable hexamethylpropylene amine oxime. The absence of perfusion in the cerebral hemispheres and brainstem was described as a pattern consistent with BD. The diagnosis was correlated to the transcranial Doppler and / or electroencephalographic findings. RESULTS: A total of 66.1% of the patients were men with an average age of 60 years [IQR: 51-72]. The most frequent causes resulting in BD were hemorrhagic stroke (48.2%, n=27), followed by traumatic brain injury (30.4%, n=17), ischemic stroke (10.7%, n=6) and post-cardiac arrest anoxic encephalopathy (7.1%, n=4). A clinical diagnosis of BD was made in all cases, and the portable gamma-camera confirmed the diagnosis in 100% of the patients with a pattern characterized by the absence of brain perfusion. In addition, the results were compared with the transcranial Doppler findings in 46 patients, confirming the presence of diastolic reverberation and / or systolic peaks. The electroencephalographic tracing was obtained in 10 cases, with the appearance of electrical silence, due to the absence of an acoustic window in the transcranial Doppler study. CONCLUSIONS: A portable gamma-camera could be a useful and feasible tool for the diagnosis of BD.


Asunto(s)
Muerte Encefálica/diagnóstico por imagen , Cámaras gamma , Cintigrafía , Anciano , Lesiones Traumáticas del Encéfalo/complicaciones , Lesiones Traumáticas del Encéfalo/diagnóstico por imagen , Electroencefalografía , Estudios de Factibilidad , Femenino , Accidente Cerebrovascular Hemorrágico/complicaciones , Accidente Cerebrovascular Hemorrágico/diagnóstico por imagen , Humanos , Accidente Cerebrovascular Isquémico/complicaciones , Accidente Cerebrovascular Isquémico/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Oximas/administración & dosificación , Síndrome de Paro Post-Cardíaco/complicaciones , Síndrome de Paro Post-Cardíaco/diagnóstico por imagen , Estudios Prospectivos , Cintigrafía/instrumentación , Cintigrafía/métodos , Tecnecio/administración & dosificación , Ultrasonografía Doppler Transcraneal
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA