Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 365
Filtrar
1.
J Pharm Biomed Anal ; 246: 116224, 2024 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-38759321

RESUMEN

Cardiovascular diseases, including fatal myocardial infarctions from atheromatous plaques, are the primary global mortality cause. Detecting stenotic atheromatous plaques is possible through coronary angiography, but vulnerable plaques with eccentric remodeling are undetectable with current diagnostic methods. Addressing this challenge, our group developed a radiopharmaceutical drug targeting vascular cell adhesion molecule 1 (VCAM-1), radiolabeled with technetium-99m. Given the absence of a monograph in the European Pharmacopoeia, and in order to draft the investigational medicinal product documentation, analytical methods had to be validated by high performance liquid chromatography (HPLC) and thin layer chromatography (TLC) to determine the radiochemical purity (RCP) of 99mTc-cAbVCAM1-5. This study therefore presents the results of the validation of analytical methods obtained in this context. The method validation followed the European Association of Nuclear Medicine (EANM) recommendations adapted from ICH Q2(R1), ensuring conformity with specificity, accuracy, repeatability and intermediate precision, linearity, robustness, quantification limit (LoQ), and range criteria. Regarding the results of specificity, both HPLC and TLC methods demonstrated excellent separation of 99mTc-cAbVCAM1-5 from impurities 99mTcO4-. Accuracy results indicated recovery percentages within the range of 99.52-101.40% for the HPLC and 99.51-101.97% for TLC, ensuring reliable measurements for each concentration of 99mTcO4-. Precision of the methods was validated by assessing repeatability and intermediate precision. Linearity was determined over the usual concentrations range and the correlation coefficient was greater than 0.99 for both methods. The limit of quantification was measured by diluting the 99mTcO4- to obtain a signal-to-noise ratio of around 10:1. Under these conditions, we obtained an LOQ of 2.10 MBq/mL for HPLC and 2Mbq/mL for TLC. In conclusion, the analytical methods developed in this study comply with EANM recommendations. This therefore allows us to correctly assess the radiochemical purity of 99mTc-cAbVCAM1-5, a new radiotracer targeting inflammation in vulnerable plaques.


Asunto(s)
Radiofármacos , Cromatografía Líquida de Alta Presión/métodos , Cromatografía en Capa Delgada/métodos , Radiofármacos/química , Radiofármacos/análisis , Reproducibilidad de los Resultados , Tecnecio/química , Tecnecio/análisis , Compuestos de Organotecnecio/química , Compuestos de Organotecnecio/análisis
2.
Artículo en Inglés | MEDLINE | ID: mdl-38626842

RESUMEN

BACKGROUND AND OBJECTIVES: In a hospital radiopharmacy with 2a operational level, including the preparation of radiopharmaceuticals from prepared and approved reagent kits, it is common to have a single activimeter or dose calibrator for labeling and fractionation, and to perform the quality controls of the 99mTc-radiopharmaceuticals. In certain cases, the accumulation of radioactive material or accidental contamination of the work area causes the background to exceed the limits to carry out the radiochemical purity analyses and it is necessary to look for viable alternatives. In this work, a Geiger Müller detector (equipped with a probe for measuring surface contamination) frequently used for radioprotection purposes, was validated as an alternative and its performance was compared against the activimeter for 99mTc-radiopharmaceuticals. MATERIALS AND METHODS: Using [99mTc]pertechnetate, systematic studies of error analyses and detector response to activity concentration, activity and measurement time were carried out in liquid matrices and in paper. The results were compared against an activimeter calibrated for [99mTc]Tc. RESULTS: The developed method was used to determine the radiochemical purity of the compounds [99mTc]Tc-MDP and [99mTc]Tc-MIBI by ascending paper chromatography tests, obtaining comparable values to those measured with an activimeter in the same system (within 1% uncertainty) and using the method of vial partitioning in a dedicated equipment. CONCLUSIONS: This work demonstrates that a Geiger Müller detector with a probe for measuring surface contamination can be adequately used to replace other equipment in the control of radiochemical purity in the hospital radiopharmacy.


Asunto(s)
Control de Calidad , Radiofármacos , Radiofármacos/análisis , Tecnecio/análisis , Calibración , Pertecnetato de Sodio Tc 99m/análisis
3.
Artículo en Inglés | MEDLINE | ID: mdl-36833920

RESUMEN

The use of knowledge from technetium radiochemistry (even from nuclear medicine applications) allows us to select an sorbent for 99mTc radionuclide sorption, which is hydroxyapatite. Using radioisotope indication, the 99mTcO4- sorption process on synthetic hydroxyapatite was studied by the batch method in the presence of SnCl2 and FeSO4 reducing agents. The complexing organic ligands' effect on the 99mTcO4- sorption under reducing conditions was investigated. In the presence of Sn2+ ions without the addition of organic ligand, the sorption percentage reached above 90% independently of the environment. In the presence of Fe2+ ions without the addition of organic ligand, the sorption of 99mTcO4- was significantly lower and was at approximately 6%, depending on the concentration of Fe2+ ions in solution. The effect of complexing organic ligands on the 99mTcO4- sorption on hydroxyapatite from the aqueous solution, acetate buffer and phosphate buffer decreases in the following order for Sn2+: oxalic acid > ethylenediaminetetraacetic acid > ascorbic acid. In the presence of Fe2+ ions without organic ligands, the sorption reached up to 15% depending on the composition of the solution. The addition of oxalic acid and ascorbic acid increased the sorption up to 80%. The ethylenediaminetetraacetic acid had no significant effect on the sorption of technetium on hydroxyapatite.


Asunto(s)
Pertecnetato de Sodio Tc 99m , Tecnecio , Indicadores y Reactivos , Tecnecio/análisis , Durapatita/química , Ligandos , Ácido Edético , Agua , Ácido Oxálico , Adsorción
4.
Eur J Hosp Pharm ; 30(3): 167-171, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-34285112

RESUMEN

OBJECTIVES: Technetium-99m mercapto-acetyl-triglycine ([99mTc]Tc-MAG3) is a radiopharmaceutical diagnostic agent used in nuclear medicine intended for the exploration of nephrological and urological disorders. Patient safety and reliability of this imaging procedure especially depend on the radiochemical purity (RCP) of the [99mTc]Tc-MAG3 preparation. Recently, the Summary of Product Characteristics (SPC) of NephroMAG, a kit dedicated to [99mTc]Tc-MAG3 preparation, proposed a two-strip thin layer chromatography (TLC) based quality control (QC) method. Also, Straub et al recently proposed another TLC based QC method. We sought to evaluate the transferability of these QC methods in our hospital radiopharmacy and compared them to our currently employed TLC method and radio-HPLC (high-pressure liquid chromatography) to select the most appropriate in the context of hospital radiopharmacy. METHODS: Ten consecutive [99mTc]Tc-MAG3 preparations were controlled using: HPLC combined with a radiodetector (radio-HPLC), a single strip TLC method (method 1) in current use in our centre, a two-strip TLC method described in the SPC (method SPC) and a two-strip TLC method (method 2) described by Straub et al. Quantitative results for the four tested QC methods were measured and compared in terms of RCP (%), sodium pertechnetate ([99mTc]TcO4 -) (%) and duration of analysis (min). RESULTS: RCP was significantly different between method SPC and radio-HPLC (p<0.001) and method 2 (p<0.001). Also, the percentage of [99mTc]TcO4 - was statistically different between the radio-HPLC and the method SPC (p<0.001), but not with the method 1 and method 2 group (p>0.05). The duration of analysis (min) was significantly different between the four QC procedures (p<0.001) with method 2 and method SPC being the quickest. CONCLUSIONS: Our study showed it is possible to transfer and select a quick and reliable QC method for the preparation of NephroMAG kits in our centre. We therefore advise the widespread use of the method from Straub et al in hospital radiopharmacies.


Asunto(s)
Tecnecio Tc 99m Mertiatida , Tecnecio , Humanos , Tecnecio/análisis , Reproducibilidad de los Resultados , Radiofármacos/análisis , Radiofármacos/química , Control de Calidad
5.
Radiat Environ Biophys ; 60(2): 389-394, 2021 05.
Artículo en Inglés | MEDLINE | ID: mdl-33751179

RESUMEN

This paper presents results of measurements of 99mTc activity concentration in air and nuclear medical personnel blood during ventilation-perfusion SPECT lung scans. 99mTc activity measurements were conducted at the Nuclear Medicine Department, John Paul II Hospital, Krakow. Technicians and nurses who perform examinations were equipped with personal aspirators enabling air sampling to determine the radiation exposure at their workplaces. Measurements allowed to evaluate the concentration of 99mTc in 14 air samples and it ranged from 7800 ± 600 to 10,000 ± 1000 Bq m-3 for air samples collected by technicians and from 390 ± 30 to 600 ± 40 Bq m-3 for air samples collected by nurses. In addition 99mTc concentrations in blood of medical personnel were determined in 24 samples. For technicians the maximum 99mTc blood concentration levels reached 920 ± 70 Bq L-1 and 1300 ± 100 Bq L-1. In the case of nurses, the maximum estimated activity concentrations were about ten times lower, namely 71 ± 7 Bq L-1 and 39 ± 3 Bq L-1. Although the intakes appear to be relatively high, the resulting annual effective doses are about 34 µSv for technicians and only 2 µSv for nurses.


Asunto(s)
Exposición Profesional/análisis , Exposición a la Radiación/análisis , Tecnecio/análisis , Personal de Salud , Humanos , Pulmón/diagnóstico por imagen , Medicina Nuclear , Dosis de Radiación , Monitoreo de Radiación , Tecnecio/sangre , Tomografía Computarizada de Emisión de Fotón Único , Gammagrafía de Ventilacion-Perfusión
6.
J Nucl Med ; 62(4): 493-499, 2021 04.
Artículo en Inglés | MEDLINE | ID: mdl-32817142

RESUMEN

Radionuclide molecular imaging of human epidermal growth factor receptor type 2 (HER2) expression may help to stratify breast and gastroesophageal cancer patients for HER2-targeting therapies. Albumin-binding domain-derived affinity proteins (ADAPTs) are a new type of small (46-59 amino acids) protein useful as probes for molecular imaging. The aim of this first-in-humans study was to evaluate the biodistribution, dosimetry, and safety of the HER2-specific 99mTc-ADAPT6. Methods: Twenty-nine patients with primary breast cancer were included. In 22 patients with HER2-positive (n = 11) or HER2-negative (n = 11) histopathology, an intravenous injection of 385 ± 125 MBq of 99mTc-ADAPT6 was performed, randomized to an injected protein mass of either 500 µg (n = 11) or 1,000 µg (n = 11). Planar scintigraphy followed by SPECT imaging was performed after 2, 4, 6, and 24 h. An additional cohort (n = 7) was injected with 165 ± 29 MBq (injected protein mass, 250 µg), and imaging was performed after 2 h only. Results: Injections of 99mTc-ADAPT6 were well tolerated at all mass levels and not associated with adverse effects. 99mTc-ADAPT6 cleared rapidly from the blood and most other tissues. The normal organs with the highest accumulation were the kidney, liver, and lung. Effective doses were 0.009 ± 0.002 and 0.010 ± 0.003 mSv/MBq for injected protein masses of 500 and 1,000 µg, respectively. Injection of 500 µg resulted in excellent discrimination between HER2-positive and HER2-negative tumors as early as 2 h after injection (tumor-to-contralateral breast ratio, 37 ± 19 vs. 5 ± 2; P < 0.01). The tumor-to-contralateral breast ratios for HER2-positive tumors were significantly (P < 0.05) higher for an injected mass of 500 µg than for either 250 or 1,000 µg. Conclusion: Injections of 99mTc-ADAPT6 are safe and associated with low absorbed and effective doses. A protein dose of 500 µg is preferable for discrimination between tumors with high and low expression of HER2. Further studies are justified to evaluate whether 99mTc-ADAPT6 can be used as an imaging probe to stratify patients for HER2-targeting therapy in areas where PET imaging is not readily available.


Asunto(s)
Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/metabolismo , Regulación Neoplásica de la Expresión Génica , Receptor ErbB-2/metabolismo , Tomografía Computarizada de Emisión de Fotón Único , Adulto , Femenino , Humanos , Persona de Mediana Edad , Radiometría , Seguridad , Tecnecio/análisis
7.
Curr Radiopharm ; 14(1): 57-63, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-32720609

RESUMEN

BACKGROUND: Extremity exposures may raise the risk of cancer induction among radiographers involved in the preparation and administration of technetium-99m labelled radiopharmaceuticals. OBJECTIVE: To estimate finger doses on radiographers at a South African tertiary hospital. METHODS: Adhesive tape was used to securely fix a calibrated thermoluminescent dosimeter (TLD) on fingertips and bases of ring and index fingers of both hands of five radiographers who prepared and administered technetium-99m labelled radiopharmaceuticals. Rubber gloves were worn to avoid TLD contamination. TLDs doses were read with a Harsaw TLD Reader (Model 3500) after a week. RESULTS: Five radiographers prepared and administered technitium-99m labelled radiopharmaceuticals (activity range; 78.20 GBq - 132.78 GBq during a one-week measurement period). A radiographer handling 132.78 GBq received 4.74±0.52 mSv on both hands; 5.52, 4.55, 5.11 and 4.60 mSv on the fingertip of the index finger of the dominant hand (FIDH), fingertip of the ring finger of the dominant hand (FRDH), fingertip of the index finger of the non-dominant hand (FINDH) and fingertip of the ring finger of the non-dominant hand (FRNDH), respectively. The respective doses received on the finger bases were 4.50 mSv, 4.60, 4.21 and 3.48 mSv. The radiographer handling 78.20 GBq received 0.85±0.18 mSv on both hands, 1.04, 1.17, 0.77 and 1 mSv for the FIDH, FRDH, FINDH and FRNDH, respectively, while respective doses for the bases were 0.8, 0.9, 0.6 and 0.8 mSv. CONCLUSION: The extremity exposures were below the annual limit (500 mSv). However, the use of syringe shields could still reduce the finger doses further.


Asunto(s)
Medicina Nuclear/métodos , Exposición Profesional/análisis , Radiofármacos/análisis , Tecnecio/análisis , Dedos , Humanos , Dosis de Radiación , Sudáfrica , Dosimetría Termoluminiscente/métodos
8.
J Cancer Res Clin Oncol ; 147(6): 1813-1823, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-33230583

RESUMEN

PURPOSE: The usage of radioactive Technetium99m (Tc99m) colloid for the purpose of sentinel lymph node biopsy (SLNB) in early breast cancer is considered the gold standard in Germany. However, new tracers, such as near-infrared (NIR) imaging agents like indocyanine green (ICG) could offer an alternative in future, as they overcome drawbacks associated with radioactive Technetium99m (Tc99m) like limited availability, high costs and radioactivity exposure for both patients and surgeons. METHODS: In this double-arm retrospective study, we sought to establish the usefulness of indocyanine green as an alternative or an addition to the conventional Technetium99m (Tc99m) in the identification of the SLN in early breast cancer. RESULTS: Among the 161 patients who underwent primary SLNB, 34 patients had at least 1 SLN with metastasis. Among these patients with SLN metastasis, 33 had the SLN detected by ICG; while 31 had the SLN detected by Tc99m. The conventional Technetium99m radiotracer failed to detect 2 patients with metastasis in this Arm of the study. Among the 87 patients who underwent SLNB after NACT, 13 patients had at least 1 SLN with metastasis. Among these 13 patients with SLN metastasis, ICG and Tc99m had detected the SLN among 12 patients, while 1 patient had been detected by ICG alone. CONCLUSIONS: Our results show that ICG is as effective as the radioisotope for SLNB even among patients who have undergone NACT. This trial is registered with the German Clinical Trial Register, ID: DRKS00013606.


Asunto(s)
Protocolos de Quimioterapia Combinada Antineoplásica/farmacología , Neoplasias de la Mama/patología , Biopsia del Ganglio Linfático Centinela , Ganglio Linfático Centinela/efectos de los fármacos , Ganglio Linfático Centinela/diagnóstico por imagen , Adulto , Anciano , Anciano de 80 o más Años , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapéutico , Neoplasias de la Mama/tratamiento farmacológico , Colorantes/análisis , Colorantes/farmacocinética , Diagnóstico por Imagen/instrumentación , Diagnóstico por Imagen/métodos , Femenino , Fluorescencia , Humanos , Verde de Indocianina/análisis , Verde de Indocianina/farmacocinética , Metástasis Linfática , Persona de Mediana Edad , Terapia Neoadyuvante , Imagen Óptica/instrumentación , Imagen Óptica/métodos , Valor Predictivo de las Pruebas , Estudios Retrospectivos , Ganglio Linfático Centinela/metabolismo , Ganglio Linfático Centinela/patología , Biopsia del Ganglio Linfático Centinela/instrumentación , Biopsia del Ganglio Linfático Centinela/métodos , Tecnecio/análisis , Tecnecio/farmacocinética
9.
Artículo en Inglés, Español | MEDLINE | ID: mdl-32201272

RESUMEN

OBJECTIVE: To optimize radiolabeling with 99mTc and 67Ga of albumin nanoparticles coated with 4 differents synthetic polymers and to evaluate their stability in vivo and in vitro, as well as their biodistribution in vivo after intravenous administration. MATERIAL AND METHODS: The nanoparticles were prepared using albumin and NOTA-modified albumin by the desolvation method and coated with 4 different polymers; HPMC, GMN2, GPM2 and GTM2. They were purified, lyophilized and characterized. Radiolabelling with 99mTc was perfomed with 74 MBq of 99mTc sodium pertechnetate, previously reduced with and acid solution of tin chloride at different concentrations (0.003, 0.005, 0.007, 0.01, 0.05 and 0.1mg/ml) and at different times (5, 10, 15, 30 and 60minutes) and temperatures (room temperature, 40°C and 60°C). Radiolabelling with 67Ga was perfomed by incubation of the nanoparticles with 37 MBq of 67Gallium chloride (obtained from commercial gallium-67 citrate) at different times (10 and 30minutes) and temperatures (room temperature, 30°C and 60°C), and posterior purification with microconcentrators. The radiochemical purity was evaluated by TLC. Stability studies of radiolabeled nanoparticles in physiological serum and blood plasma were perfomed. Biodistribution studies of nanoparticles coated with GPM2 polymer were carried out in Wistar rats after intravenous administration of the nanoparticles. Control animals were carried out with 99mTc sodium pertechnetate and 67Ga chloride. To do so, the animals were killed and activity in organs was measured in a gamma counter. RESULTS: 99mTc labeling was carried out optimally with a tin concentration of 0.007mg/ ml for the GPM2 nanoparticles and 0.005mg / ml for the rest of the formulations, with a radiolabelling time of 10minutes at room temperature. In the case of 67Ga the label was optimized at 30° C temperature and 30minutes of incubation. In both cases the radiochemical purity obtained was greater than 97%. The nanoparticles showed high stability in vitro after 48hours of labeling (70% nanoparticles labeled with 99mTc and 90% those labeled with 67Ga). Biodistribution studies of nanoparticles 99mTc -GPM2 and 67Ga -NOTA-GPM2 showed a high accumulation of activity in the liver at 2 and 24hours after intravenous administration. CONCLUSION: The labeling procedure with 99mTc and 67Ga of albumin and albumin modified with NOTA nanoparticles allows obtaining nanoparticles with high labeling yields and adequate in vitro stability, allowing their use for in vivo studies.


Asunto(s)
Radioisótopos de Galio/farmacocinética , Galio/farmacocinética , Marcaje Isotópico/métodos , Nanopartículas/administración & dosificación , Poliaminas/química , Radiofármacos/farmacocinética , Albúmina Sérica Humana/farmacocinética , Tomografía Computarizada por Tomografía Computarizada de Emisión de Fotón Único/métodos , Tecnecio/farmacocinética , Tiamina/química , Animales , Cromatografía en Capa Delgada , Estabilidad de Medicamentos , Femenino , Galio/administración & dosificación , Galio/análisis , Radioisótopos de Galio/administración & dosificación , Radioisótopos de Galio/análisis , Compuestos Heterocíclicos con 1 Anillo , Derivados de la Hipromelosa , Inyecciones Intravenosas , Nanopartículas/análisis , Polietilenglicoles , Radiofármacos/administración & dosificación , Radiofármacos/análisis , Ratas , Ratas Wistar , Albúmina Sérica Humana/administración & dosificación , Albúmina Sérica Humana/análisis , Tecnecio/administración & dosificación , Tecnecio/análisis , Temperatura , Compuestos de Estaño , Distribución Tisular
10.
Sci Rep ; 10(1): 4179, 2020 03 06.
Artículo en Inglés | MEDLINE | ID: mdl-32144340

RESUMEN

This study aims to evaluate the radiation dosimetry of a new technetium-99m‒labelled small-molecule inhibitor of prostate-specific membrane antigen (HYNIC-Glu-Urea-A, 99mTc-HYNIC-PSMA) and its feasibility as a tumor-imaging agent in prostate cancer (PCa) patients. A total of 15 PCa patients were enrolled in this study. For the dosimetry study, 5 PCa patients received whole-body planar scans at 0.5 h, 1 h, 2 h, 4 h and 8 h after 99mTc-HYNIC-PSMA injection. The Dosimetry Toolkit (GE, Milwaukee) was used to process the data and segment the organs in the SPECT/CT images, which were then projected onto planar images. The organ-specific absorbed doses, total-body absorbed doses and 99mTc-HYNIC-PSMA effective doses of patients were calculated using OLINDA/EXM 1.1 software. Whole-body SPECT/CT images were also acquired from additional 10 prostate patients to investigate the feasibility of 99mTc-HYNIC-PSMA for imaging tumors by calculating the ratio of tumor-to-background tracer uptake at 2 h after 740 MBq administration. The total-body absorbed dose was 1.54E-03 ± 2.43E-04 mGy/MBq, and the effective dose was 3.72E-03 ± 4.5E-04 mSv/MBq. Compared to published studies of other similar PSMA tracers and 99mTc-targeted conventional tracers, the absorbed doses of 99mTc-HYNIC-PSMA in all organs showed that it could be used safely in the human body. In addition, 99mTc-HYNIC-PSMA showed high tracer uptake (with a tumor-to-background ratio of 9.42 ± 2.62) in the malignant lesions of PCa patients, making it a promising radiopharmaceutical imaging method for site-specific management of PCa.


Asunto(s)
Neoplasias de la Próstata/diagnóstico por imagen , Radiometría/métodos , Programas Informáticos , Tecnecio/análisis , Anciano , Humanos , Procesamiento de Imagen Asistido por Computador , Masculino , Persona de Mediana Edad , Modelos Teóricos , Tomografía Computarizada por Tomografía Computarizada de Emisión de Fotón Único
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA