Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 4.838
Filtrar
1.
Rev Assoc Med Bras (1992) ; 70(6): e20231689, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39045958

RESUMEN

OBJECTIVE: Several studies have investigated the correlation between the effects of different surgical treatments and laboratory exams for schistosomal portal hypertension, especially concerning portal system thrombosis. The etiopathogenic factors of this thrombosis are not fully understood. In this study, the correlation between surgical treatment for schistosomal portal hypertension and the occurrence of postoperative portal system thrombosis was investigated. METHODS: A total of 61 patients who underwent surgical treatment for schistosomal portal hypertension were distributed into four groups: Patients in Group 1 (n=12) underwent portal variceal disconnection associated with splenic artery ligation and spleen preservation. Patients in Group 2 (n=20) underwent portal variceal disconnection and total splenectomy. Patients in Group 3 (n=20) underwent portal variceal disconnection with subtotal splenectomy, preserving the upper splenic pole supplied by the splenogastric vessels. Patients in Group 4 (n=9) underwent portal variceal disconnection with total splenectomy and autogenous splenic implants on the greater omentum. Late postoperative portal vein thrombosis was diagnosed using Doppler ultrasound. RESULTS: Over the 10-year follow-up, portal vein thrombosis occurred in 26 operated patients (42.6%), with no significant difference observed among the four surgical groups (p=0.217). Most of the thrombi only partially occluded the portal system veins. All the patients presented with a thrombus inside the portal vein. There was no difference in hematological and biochemical tests between groups with or without portal vein thrombosis. CONCLUSIONS: Portal vein thrombosis is often observed in the late postoperative period, irrespective of the surgical treatment employed, and is not associated with patient characteristics or any hematological and biochemical tests.


Asunto(s)
Hipertensión Portal , Vena Porta , Esplenectomía , Trombosis de la Vena , Humanos , Hipertensión Portal/cirugía , Hipertensión Portal/etiología , Femenino , Masculino , Esplenectomía/efectos adversos , Esplenectomía/métodos , Vena Porta/cirugía , Vena Porta/diagnóstico por imagen , Adulto , Persona de Mediana Edad , Trombosis de la Vena/etiología , Trombosis de la Vena/cirugía , Trombosis de la Vena/diagnóstico por imagen , Resultado del Tratamiento , Adulto Joven , Esquistosomiasis/cirugía , Esquistosomiasis/complicaciones , Estudios de Seguimiento , Complicaciones Posoperatorias , Ligadura/métodos , Várices Esofágicas y Gástricas/cirugía , Várices Esofágicas y Gástricas/etiología , Adolescente , Ultrasonografía Doppler
2.
PLoS One ; 19(7): e0305725, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39028708

RESUMEN

BACKGROUND AND OBJECTIVE: The measurement of portal venous pressure (PVP) has been extensively studied, primarily through indirect methods. However, the potential of ultrasound-guided percutaneous transhepatic PVP measurement as a direct method has been largely unexplored. This study aimed to investigate the accuracy, safety, and feasibility of this approach. METHODS: In vitro, the experiment aimed to select a needle that could accurately transmit pressure, had a small inner diameter and was suitable for liver puncture, and performed on 20 healthy New Zealand white rabbits. An ultrasound-guided percutaneous transhepatic portal vein puncture was undertaken to measure PVP. Additionally, free hepatic venous pressure (FHVP) and wedged hepatic venous pressure (WHVP) were measured under digital subtraction angiography (DSA). The correlation between the two methods was assessed. Enroll study participants from October 18, 2023 to November 11, 2023 with written informed consent. Five patients were measured the PVP under ultrasound guidance before surgery to determine the feasibility of this measurement method. RESULTS: There was no significant difference in the results obtained using 9 different types of needles (P > 0.05). This demonstrated a great repeatability (P < 0.05). The 22G chiba needle with small inner diameter, allowing for accurate pressure transmission and suitable for liver puncture, was utilized for percutaneous transhepatic PVP measurement. There were positive correlations between PVP and HVPG (r = 0.881), PVP and WHVP (r = 0.709), HVPG and WHVP (r = 0.729), IVCP and FHVP (r = 0.572). The PVP was accurately and safely measured in 5 patients with segmental hepatectomy. No complications could be identified during postoperative ultrasound. CONCLUSION: Percutaneous transhepatic portal venous puncture under ultrasound guidance is accurate, safe and feasible to measure portal venous pressure. CLINICAL TRIAL REGISTRATION NUMBER: This study has been registered in the Chinese Clinical Trial Registry with registration number ChiCTR2300076751.


Asunto(s)
Estudios de Factibilidad , Presión Portal , Vena Porta , Animales , Conejos , Humanos , Masculino , Femenino , Vena Porta/diagnóstico por imagen , Persona de Mediana Edad , Ultrasonografía Intervencional/métodos , Adulto , Hígado/diagnóstico por imagen , Hígado/cirugía , Hígado/irrigación sanguínea , Punciones/métodos , Ultrasonografía/métodos , Anciano , Angiografía de Substracción Digital/métodos , Determinación de la Presión Sanguínea/métodos
3.
Surg Radiol Anat ; 46(8): 1177-1184, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38963433

RESUMEN

PURPOSES: The purpose of this study was to develop a new and more comprehensive classification system for portal vein (PV) variations using three-dimensional visualization and evaluation (3DVE) and to discuss the prevalence rates and clinical implications of the variants. METHODS: The anatomies of PVs were tracked and analyzed by using three-dimensional visualization of CT images acquired between 2013 and 2022. Scans from 200 adults were evaluated and a total of 178 patients (N = 178) were included in the study. The new classification system, named BLB classification, was developed based on the level of the absent PV branch in each variant anatomy. RESULTS: Using the BLB classification system, PVs were divided into thirteen subtypes. Only 82.6-84.8% of the portal veins of the 178 patients were depicted in Atri's, Cheng's or Covey's classification, compared with 100% identified by the BLB classification. The BLB classification was validated against external data sets from previous studies, with 97.0-98.9% of patients classified by the BLB system. CONCLUSION: Variant PV anatomies are more commonly seen based on 3DVE than in previous reports. The BLB classification covers almost all portal vein variants and may be used for planning liver surgery.


Asunto(s)
Variación Anatómica , Imagenología Tridimensional , Vena Porta , Tomografía Computarizada por Rayos X , Humanos , Vena Porta/anatomía & histología , Vena Porta/diagnóstico por imagen , Masculino , Femenino , Persona de Mediana Edad , Adulto , Anciano , Anciano de 80 o más Años , Estudios Retrospectivos , Adulto Joven
4.
Surg Endosc ; 38(7): 4085-4093, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38862823

RESUMEN

INTRODUCTION: The right intersectional plane and the right hepatic hilum were noted too often exhibit anatomical variations, making difficult the laparoscopic right anterior sectionectomy (LRAS). METHODS: We analyzed the anatomical features employing 3D-CT images of 55 patients, and evaluated these features according to the course of ventral branches of segment VI of the portal vein (PV, P6a) relative to the right hepatic vein (RHV). RESULTS: P6a run on the dorsal side of RHV in 32 patients (58%, Dorsal-P6a) and the ventral side of RHV in 23 (42%, Ventral-P6a). Ventral-P6a had more patients with S6 partially drained by middle hepatic vein (MHV, 39% vs. 0%, P < 0001), the narrower angle between the anterior and posterior branches of PV (73.1° vs. 93.8°, P = 0.006), the wider angle between the RHV and inferior vena cava  (54.3° vs. 44.3°, P < 0.001), and more steeply pitched angle between S6 and S7 along the RHV (140.6° vs. 162.0°, P < 0.001) compared to Dorsal-P6a. CONCLUSION: In LRAS for Dorsal-P6a patients, the transection surface was relatively flat. In LRAS for Ventral-P6a patients, the narrow space between anterior and posterior glissons makes difficult the glissonean approach. The transection plane was steeply pitched, and RHV was partially exposed. S6 was often partially drained to MHV in 39% of the Ventral-P6a patients, which triggers congestion during liver transection of a right intersectional plane after first splitting the confluence of this branch.


Asunto(s)
Hepatectomía , Venas Hepáticas , Imagenología Tridimensional , Laparoscopía , Vena Porta , Tomografía Computarizada por Rayos X , Humanos , Vena Porta/cirugía , Vena Porta/anatomía & histología , Vena Porta/diagnóstico por imagen , Femenino , Venas Hepáticas/diagnóstico por imagen , Venas Hepáticas/anatomía & histología , Venas Hepáticas/cirugía , Masculino , Laparoscopía/métodos , Persona de Mediana Edad , Hepatectomía/métodos , Anciano , Adulto , Estudios Retrospectivos
5.
Cardiorenal Med ; 14(1): 375-384, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38897186

RESUMEN

INTRODUCTION: Determining ultrafiltration volume in patients undergoing intermittent hemodialysis (IHD) is an essential component in the assessment and management of volume status. Venous excess ultrasound (VExUS) is a novel tool used to quantify the severity of venous congestion at the bedside. Given the high prevalence of pulmonary hypertension in patients with end-stage kidney disease (ESKD), venous Doppler could represent a useful tool to monitor decongestion in these patients. METHODS: This is a prospective observational study conducted in ESKD patients who were admitted to the hospital requiring IHD and ultrafiltration. Inferior vena cava maximum diameter (IVCd), portal vein Doppler (PVD), and hepatic vein Doppler (HVD) were performed in all patients before and after a single IHD session. RESULTS: Forty-one patients were included. The prevalence of venous congestion was 88% based on IVCd and 63% based on portal vein pulsatility fraction (PVPF). Both mean IVCd and PVPF displayed a significant improvement after ultrafiltration. The percent decrease in PVPF was significantly larger than the percent decrease in IVCd. HVD alterations did not significantly improve after ultrafiltration. CONCLUSIONS: Our study revealed a high prevalence of venous congestion in hospitalized ESKD patients undergoing hemodialysis. After a single IHD session, there was a significant improvement in both IVCd and PVPF. HVD showed no significant improvement with one IHD session. PVPF changes were more sensitive than IVCd changes during volume removal. This study suggests that, due to its rapid response to volume removal, PVD, among the various components of the VExUS grading system, could be more effective in monitoring real-time decongestion in patients undergoing IHD.


Asunto(s)
Fallo Renal Crónico , Vena Porta , Humanos , Femenino , Masculino , Vena Porta/diagnóstico por imagen , Vena Porta/fisiopatología , Fallo Renal Crónico/complicaciones , Fallo Renal Crónico/terapia , Estudios Prospectivos , Persona de Mediana Edad , Ultrasonografía Doppler/métodos , Anciano , Diálisis Renal/efectos adversos , Hiperemia/diagnóstico por imagen , Hiperemia/fisiopatología , Vena Cava Inferior/diagnóstico por imagen , Venas Hepáticas/diagnóstico por imagen , Venas Hepáticas/fisiopatología , Adulto
6.
J Investig Med High Impact Case Rep ; 12: 23247096241258063, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38828786

RESUMEN

Hepatic encephalopathy is uncommon in the absence of cirrhosis. We report a 71-year-old woman who presented with altered mental status in the setting of hyperammonemia for the second time in 6 months. Magnetic resonance imaging of the abdomen revealed an uncommon portosystemic shunt involving an enlarged posterior branch of the right portal vein and an accessory right hepatic vein, with no features of cirrhosis. Appropriate management of these patients with ammonia-lowering therapy can reduce repeat episodes and improve quality of life. This case demonstrates the importance of diagnosing non-cirrhotic hepatic encephalopathy in patients with altered mental status.


Asunto(s)
Encefalopatía Hepática , Hiperamonemia , Imagen por Resonancia Magnética , Vena Porta , Humanos , Encefalopatía Hepática/etiología , Femenino , Anciano , Vena Porta/anomalías , Vena Porta/diagnóstico por imagen , Hiperamonemia/etiología , Venas Hepáticas/anomalías , Venas Hepáticas/diagnóstico por imagen
7.
J Vet Sci ; 25(3): e37, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38834507

RESUMEN

IMPORTANCE: The portal vein to aorta (PV/Ao) ratio is used to assess the clinical significance of extrahepatic portosystemic shunt (EHPSS). Previous studies using computed tomography (CT) were conducted in dogs but not in cats. OBJECTIVE: This study aimed to establish normal reference values for PV indices (PV/Ao ratio and PV diameter) in cats and determine the usefulness of these for predicting symptomatic EHPSS. METHODS: This study included 95 dogs and 114 cats that underwent abdominal CT. The canine normal (CN) group included dogs without EHPSS. The cats were classified into feline normal (FN, 88/114), feline asymptomatic (FA, 16/114), and feline symptomatic (FS, 10/114) groups. The PV and Ao diameters were measured in axial cross-sections. RESULTS: The group FN had a higher PV/Ao ratio than the group CN (p < 0.001). Within the feline groups, the PV indices were in the order FN > FA > FS (both p < 0.001). The mean PV diameter and PV/Ao ratio for group FN were 5.23 ± 0.77 mm and 1.46 ± 0.19, respectively. The cutoff values between groups FN and FS were 4.115 mm for PV diameter (sensitivity, 100%; specificity, 97.7%) and 1.170 for PV/Ao ratio (90%, 92.1%). The cutoff values between group FA and FS were 3.835 mm (90%, 93.8%) and 1.010 (70%, 100%), respectively. CONCLUSIONS AND RELEVANCE: The results demonstrated significant differences in PV indices between dogs and cats. In cats, the PV/Ao ratio demonstrated high diagnostic performance for symptomatic EHPSS. The PV diameter also performed well, in contrast to dogs.


Asunto(s)
Enfermedades de los Gatos , Vena Porta , Tomografía Computarizada por Rayos X , Animales , Gatos , Vena Porta/diagnóstico por imagen , Vena Porta/anomalías , Enfermedades de los Gatos/diagnóstico por imagen , Masculino , Femenino , Tomografía Computarizada por Rayos X/veterinaria , Perros , Enfermedades de los Perros/diagnóstico por imagen , Valores de Referencia , Aorta/diagnóstico por imagen
8.
J Med Case Rep ; 18(1): 246, 2024 May 14.
Artículo en Inglés | MEDLINE | ID: mdl-38741148

RESUMEN

INTRODUCTION: Thrombotic events are more than twice as common in inflammatory bowel disease patients as in the general population. We report an interesting and rare case of portal vein thrombosis as a venous thromboembolic event in the context of extraintestinal manifestations of Crohn's disease. We also conducted a literature review on portal vein thrombosis associated with inflammatory bowel disease, with the following concepts: inflammatory bowel diseases, ulcerative colitis, Crohn's disease, portal vein, and thrombosis. CASE PRESENTATION: A 24-year-old Syrian female with active chronic Crohn's disease was diagnosed 11 years ago and classified as A1L3B1P according to the Montreal classification. She had no prior surgical history. Her previous medications included azathioprine and prednisolone. Her Crohn's disease activity index was 390 points. Gastroduodenoscopy revealed grade I esophageal varices, a complication of portal hypertension. Meanwhile, a colonoscopy revealed several deep ulcers in the sigmoid, rectum, and descending colon. An investigation of portal vein hypertension revealed portal vein thrombosis. We used corticosteroids to induce remission, followed by tapering; additionally she received ustekinumab to induce and maintain remission. She began on low-molecular-weight heparin for 1 week, warfarin for 3 months, and then apixaban, a novel oral anticoagulant, after excluding antiphospholipid syndrome. Primary prophylaxis for esophageal varices was not required. After 1 year, she achieved clinical, biochemical, and endoscopic remission. Despite 1 year of treatment, a computed tomography scan revealed no improvement in portal vein recanalization. CONCLUSION: Portal vein thrombosis is a rare and poorly defined complication of inflammatory bowel disease. It is usually exacerbated by inflammatory bowel disease. The symptoms are nonspecific and may mimic a flare-up of inflammatory bowel disease, making the diagnosis difficult. Portal vein Doppler ultrasound for hospital-admitted inflammatory bowel disease patients may contribute to the diagnosis and management of this complication.


Asunto(s)
Anticoagulantes , Enfermedad de Crohn , Vena Porta , Trombosis de la Vena , Humanos , Enfermedad de Crohn/complicaciones , Femenino , Vena Porta/diagnóstico por imagen , Trombosis de la Vena/etiología , Trombosis de la Vena/diagnóstico por imagen , Trombosis de la Vena/tratamiento farmacológico , Adulto Joven , Anticoagulantes/uso terapéutico , Warfarina/uso terapéutico
10.
Nucl Med Commun ; 45(8): 651-657, 2024 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-38757155

RESUMEN

Portal vein thrombosis, a relatively frequent complication associated with hepatocellular carcinoma (HCC) and liver cirrhosis, is recognized as a significant global health concern. This is mainly due to these conditions' high prevalence and potentially severe outcomes. The aim of our study was to conduct a comprehensive literature review to evaluate the efficacy, accuracy, and clinical implications of 18F-FDG PET-CT in diagnosing and managing portal vein tumor thrombosis (PVTT) in patients with HCC. HCC, which accounts for 80% of liver malignancies, ranks as the fourth most prevalent cancer globally and is a significant contributor to cancer-related mortality. The majority of HCC patients are diagnosed at an advanced stage, leading to a deterioration in patient outcomes. Involvement of the portal vein is also a significant negative factor. This review analyzes the application of 18F-FDG PET-CT in the detection and management of PVTT in patients with HCC, with an emphasis on the importance of the maximum standardized uptake value as an essential diagnostic and prognostic marker. 18F-FDG PET-CT is invaluable for detecting recurrence and guiding management strategies, particularly in patients with high-grade HCC, and plays a pivotal role in differentiating malignant portal vein thrombi from their benign counterparts.


Asunto(s)
Carcinoma Hepatocelular , Fluorodesoxiglucosa F18 , Neoplasias Hepáticas , Vena Porta , Tomografía Computarizada por Tomografía de Emisión de Positrones , Trombosis de la Vena , Humanos , Carcinoma Hepatocelular/diagnóstico por imagen , Carcinoma Hepatocelular/complicaciones , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/complicaciones , Vena Porta/diagnóstico por imagen , Vena Porta/patología , Trombosis de la Vena/diagnóstico por imagen , Trombosis de la Vena/terapia
11.
Eur Heart J Acute Cardiovasc Care ; 13(7): 570-574, 2024 Jul 24.
Artículo en Inglés | MEDLINE | ID: mdl-38734970

RESUMEN

AIMS: Renal and liver congestion are associated with adverse outcomes in patients with tricuspid regurgitation (TR). Currently, there are no valid sonographic indicators of fluid status in this population. Intra-renal venous Doppler (IRVD) is a novel method for quantifying renal congestion but its interpretation can be challenging in severe TR due to altered haemodynamics. This study explores the potential of portal vein Doppler (PVD) as an alternative marker for decongestion during volume removal in patients with severe TR. METHODS AND RESULTS: Forty-two patients with severe TR undergoing decongestive therapy were prospectively enrolled. Inferior vena cava diameter, PVD, and IRVD were sequentially assessed during volume removal. Improvement criteria were portal vein pulsatility fraction (PVPF) < 70% and renal venous stasis index (RVSI) < 0.5 for partial improvement, and PVPF < 30% and RVSI < 0.2 for complete improvement. After volume removal, PVPF significantly improved from 130 ± 39% to 47 ± 44% (P < 0.001), while IRVD improved from 0.72 ± 0.08 to 0.54 ± 0.22 (P < 0.001). A higher proportion of patients displayed improvement in PVD compared to IRVD (partial: 38% vs. 29%, complete: 41% vs. 7%) (P < 0.001). Intra-renal venous Doppler only improved in patients with concomitant improvement in severe TR. Portal vein Doppler was the only predictor of achieving ≥5 L of negative fluid balance [area under the ROC curve (AUC) 0.83 P = 0.001]. CONCLUSION: This proof-of-concept study suggests that PVD is the only sonographic marker that can track volume removal in severe TR, offering a potential indicator for decongestion in this population. Further intervention trials are warranted to determine if PVD-guided decongestion improves patient outcomes in severe TR.


Asunto(s)
Vena Porta , Prueba de Estudio Conceptual , Insuficiencia de la Válvula Tricúspide , Humanos , Vena Porta/diagnóstico por imagen , Masculino , Femenino , Insuficiencia de la Válvula Tricúspide/fisiopatología , Insuficiencia de la Válvula Tricúspide/diagnóstico , Estudios Prospectivos , Persona de Mediana Edad , Índice de Severidad de la Enfermedad , Anciano , Ultrasonografía Doppler/métodos , Hemodinámica/fisiología , Vena Cava Inferior/diagnóstico por imagen
12.
Cir Cir ; 92(2): 267-270, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38782397

RESUMEN

Hilar cavernous transformation is the formation of venous structures rich in collateral around the portal vein. Portal vein thrombosis is a rare entity. Although there are many reasons for its etiology, few cases have been reported secondary to hydatid cysts in the liver. Here, we present a 24-year-old patient with complaints of abdominal pain and swelling. Her CT and MRI scans show cholelithiasis with portal vein thrombosis and hilar cavernous transformation due to giant hydatid cyst compression in the lateral liver sector.


La transformación cavernosa hiliar es la formación de estructuras venosas ricas en colaterales alrededor de la vena porta. La trombosis de la vena porta es una afección poco frecuente. Aunque existen muchas razones en su etiología, se han descrito pocos casos secundarios a quiste hidatídico en el hígado. Aquí se presenta el caso de una paciente de 24 años con quejas de dolor abdominal e hinchazón. La tomografía computarizada y la resonancia magnética mostraron colelitiasis con trombosis de la vena porta y transformación cavernosa hiliar por compresión del quiste hidatídico gigante en el sector lateral del hígado.


Asunto(s)
Equinococosis Hepática , Vena Porta , Humanos , Equinococosis Hepática/complicaciones , Equinococosis Hepática/diagnóstico por imagen , Equinococosis Hepática/cirugía , Femenino , Vena Porta/diagnóstico por imagen , Adulto Joven , Tomografía Computarizada por Rayos X , Trombosis de la Vena/etiología , Trombosis de la Vena/diagnóstico por imagen , Colelitiasis/complicaciones , Colelitiasis/cirugía , Colelitiasis/diagnóstico por imagen , Imagen por Resonancia Magnética , Dolor Abdominal/etiología , Hígado/parasitología , Hígado/diagnóstico por imagen
13.
Ann Cardiol Angeiol (Paris) ; 73(3): 101759, 2024 Jun.
Artículo en Francés | MEDLINE | ID: mdl-38723314

RESUMEN

Leiomyosarcomas of large vessels are rare. It is a malignant tumour and the vast majority of these tumours arose from the inferior vena cava. We report a rare case of portal vein leiomyosarcoma, in a 56-years-old female patient admitted for chronic abdominal pain with abdominal mass in the right hypochondrium all evolving in a context of deterioration in general condition. We performed an abdominopelvic CT scan and then a MRI with contrast agent which objectified a large tissue mass containing areas of necrosis at the level of the duodeno-pancreatic compartment communicating at a large angle with the portal trunk over its entire length from the hepatic hilum to the spleno-mesenteric confluence responsible for a portal cavernoma downstream. This is associated with multiple secondary nodular tissue hepatic lesions. We also noted a respect for the fatty border separating the mass of the duodenal tract and the head of the pancreas, and also the absence of dilation of the pancreatic ducts making a pancreatic origin unlikely. To eliminate a duodenal origin of the mass we performed an upper digestive endoscopy which came back without any abnormality. An ultrasound-guided trans parietal biopsy of a secondary hepatic lesion was done and the pathological result of which speaks of a secondary hepatic lesion of a leiomyosarcoma.


Asunto(s)
Leiomiosarcoma , Vena Porta , Neoplasias Vasculares , Humanos , Leiomiosarcoma/diagnóstico por imagen , Leiomiosarcoma/patología , Femenino , Persona de Mediana Edad , Vena Porta/diagnóstico por imagen , Vena Porta/patología , Neoplasias Vasculares/diagnóstico por imagen , Neoplasias Vasculares/patología , Imagen por Resonancia Magnética , Tomografía Computarizada por Rayos X
14.
Vet Radiol Ultrasound ; 65(4): 359-368, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38597362

RESUMEN

The prevalence of anatomical-based subtypes of feline congenital extrahepatic portosystemic shunts (EHPSS) has not been completely elucidated. The goal of this study was to use CT angiography to create an anatomical-based nomenclature system for feline congenital EHPSS. Additionally, subjective portal perfusion scores were generated to determine if intrinsic portal vein development was associated with different shunt conformations or patient age at the time of CT. The SVSTS and VIRIES list services were used to recruit cases. Data collected included patient DOB, gender, breed, weight, CT date, and reported diagnosis. Shunts were classified based upon (1) the shunt portal vessel(s) of origin, (2) the shunt systemic vessel(s) of insertion, and (3) any substantial portal vessels contributing to the shunt. Additionally, hepatic portal perfusion was subjectively scored between 1 (poor/none) and 5 (good/normal) based on the caliber of the intrahepatic PVs. A total of 264 CT scans were submitted from 29 institutions. Due to exclusion criteria, 33 (13%) were removed, leaving 231 CT scans to be included. Twenty-five different EHPSS anatomies were identified with five classifications accounting for 78% of all shunts (LGP [53%], LGC-post [11%], LCG [7%], LGC-pre [4%], and PC [4%]). Shunt origin involved the left gastric vein in 75% of the described classifications. Significant differences were identified among the five most common shunt types with respect to age at the time of CT scan (P = .002), breed (P < .001), and subjective portal perfusion score (P < .001). This refined anatomical classification system for feline EHPSS may enable improved understanding, treatment comparisons, and outcome prediction for cats with these anomalies.


Asunto(s)
Enfermedades de los Gatos , Angiografía por Tomografía Computarizada , Vena Porta , Animales , Gatos , Angiografía por Tomografía Computarizada/veterinaria , Femenino , Masculino , Vena Porta/anomalías , Vena Porta/diagnóstico por imagen , Enfermedades de los Gatos/diagnóstico por imagen , Sistema Porta/anomalías , Sistema Porta/diagnóstico por imagen , Malformaciones Vasculares/veterinaria , Malformaciones Vasculares/diagnóstico por imagen , Malformaciones Vasculares/clasificación
16.
J Biomech ; 167: 112086, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38615481

RESUMEN

Accurate assessment of portacaval pressure gradient (PCG) in patients with portal hypertension (PH) is of great significance both for diagnosis and treatment. This study aims to develop a noninvasive method for assessing PCG in PH patients and evaluate its accuracy and effectiveness. This study recruited 37 PH patients treated with transjugular intrahepatic portosystemic shunt (TIPS). computed tomography angiography was used to create three dimension (3D) models of each patient before and after TIPS. Doppler ultrasound examinations were conducted to obtain the patient's portal vein flow (or splenic vein and superior mesenteric vein). Using computational fluid dynamics (CFD) simulation, the patient's pre-TIPS and post-TIPS PCG was determined by the 3D models and ultrasound measurements. The accuracy of these noninvasive results was then compared to clinical invasive measurements. The results showed a strong linear correlation between the PCG simulated by CFD and the clinical invasive measurements both before and after TIPS (R2 = 0.998, P < 0.001 and R2 = 0.959, P < 0.001). The evaluation accuracy of this noninvasive method reached 94 %, and the influence of ultrasound result errors on the numerical accuracy was found to be marginal if the error was less than 20 %. Furthermore, the information about the hemodynamic environment in the portal system was obtained by this numerical method. Spiral flow patterns were observed in the portal vein of some patients. In a conclusion, this study proposes a noninvasive numerical method for assessing PCG in PH patients before and after TIPS. This method can assist doctors in accurately diagnosing patients and selecting appropriate treatment plans. Additionally, it can be used to further investigate potential biomechanical causes of complications related to TIPS in the future.


Asunto(s)
Hipertensión Portal , Derivación Portosistémica Intrahepática Transyugular , Humanos , Derivación Portosistémica Intrahepática Transyugular/efectos adversos , Derivación Portosistémica Intrahepática Transyugular/métodos , Hidrodinámica , Vena Porta/diagnóstico por imagen , Hipertensión Portal/diagnóstico por imagen , Hemodinámica
17.
J Int Med Res ; 52(4): 3000605241240992, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38597115

RESUMEN

Portal vein gas accumulation and intestinal pneumatosis are uncommon signs indicating a high mortality risk in cases of intestinal ischemic necrosis. However, the widespread use of computed tomography has led to an increase in detection of benign lesions. We report a case of portal vein gas accumulation resulting from organophosphorus pesticide poisoning. A male patient was brought to the hospital in a comatose state with bilateral pupils that measured 1.0 mm, and he showed shortness of breath and wet rattles in the lungs. A cholinesterase concentration of 214 U/L was detected on an auxiliary examination. The patient was diagnosed with organophosphorus pesticide poisoning and underwent mechanical ventilation, hemoperfusion, and continuous renal replacement therapy according to the poisoning guidelines. On the fifth day, considerable abdominal distension was observed. An abdominal computed tomography scan revealed dilation of the small bowel and ascending colon with fluid and gas accumulation, as well as gas within the intestinal wall and hepatic veins. Although portal vein gas and intestinal pneumatosis are a sign of mortality requiring immediate surgical intervention, an increasing number of benign cases suggests potential benefits of conservative treatment approaches.


Asunto(s)
Enfermedades Intestinales , Plaguicidas , Neumatosis Cistoide Intestinal , Enfermedades Vasculares , Humanos , Masculino , Vena Porta/diagnóstico por imagen , Vena Porta/patología , Compuestos Organofosforados , Neumatosis Cistoide Intestinal/diagnóstico , Neumatosis Cistoide Intestinal/diagnóstico por imagen , Necrosis/patología
18.
Pediatr Transplant ; 28(3): e14737, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38602290

RESUMEN

BACKGROUND: Venous complications after pediatric liver transplantation seriously affect the survival rate of patients and grafts. At present, the diagnostic indicators have not been unified. Venous complications may cause portal hypertension, which may lead to splenomegaly and splenic vein dilatation. Therefore, the changes in spleen may be closely related to the venous complications. The purpose of this study was to explore the relationship between ultrasonic splenic parameters and venous complications and to study whether these splenic parameters can be used for the diagnosis of venous complications. METHODS: We retrospectively included pediatric patients who underwent liver transplantation and collected ultrasonic spleen parameters before, and then 1-3 days, 1-3 weeks, 1-3 months, and 4-12 months after liver transplantation. We observed whether there were portal vein or hepatic vein complications within 1 year after liver transplantation. RESULTS: Among 109 pediatric patients after liver transplantation included in our study, 11 of them suffered from portal vein complications and nine hepatic vein complications. Spleen transverse diameter, spleen longitudinal diameter, spleen portal vein diameter, spleen index, spleen transverse diameter ratio, spleen longitudinal diameter ratio, and spleen index ratio were independent risk factors of venous complications. The accuracy of spleen transverse diameter (AUROC: 0.73), spleen index (AUROC: 0.70), spleen transverse diameter ratio (AUROC: 0.71), and spleen index ratio (AUROC: 0.72) in predicting venous complications were higher than other ones. CONCLUSIONS: Ultrasonic examination is a common follow-up method for pediatric patients after liver transplantation and the application of ultrasonic spleen parameters may be helpful to monitor venous complications.


Asunto(s)
Trasplante de Hígado , Bazo , Humanos , Niño , Bazo/diagnóstico por imagen , Trasplante de Hígado/efectos adversos , Trasplante de Hígado/métodos , Estudios Retrospectivos , Vena Porta/diagnóstico por imagen , Ultrasonografía , Vena Esplénica/diagnóstico por imagen
19.
Radiographics ; 44(5): e230118, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38573815
20.
BMC Womens Health ; 24(1): 211, 2024 Apr 02.
Artículo en Inglés | MEDLINE | ID: mdl-38566064

RESUMEN

Due to the thrombohemorrhagic potential of essential thrombocythemia, pregnancy complicated by essential thrombocythemia should be recognized as a risk factor for obstetric complications. Here, we report the case of a patient with essential thrombocythemia with two significantly different pregnancy outcomes. Her first pregnancy (at 30 years of age) ended with an uneventful term delivery. However, the patient progressed to cavernous transformation of the portal vein in the period between her two pregnancies and subsequently experienced deep venous thrombosis during the first trimester of her second pregnancy (at 36 years of age). The patient's platelet count during pregnancy was within the normal range, so she ignored previous instances of essential thrombocytosis (at 26 years of age). The patient's main symptom was unrelieved pain in her leg. After that, she was successfully treated with anticoagulant throughout her entire pregnancy, resulting in a term vaginal delivery. This case highlights the importance of assessing pregnant patients with essential thrombocythemia according to their risk stratification. Specifically, risk assessments for potential pregnancy complications should take into account advanced maternal age and a previous history of thrombosis. Patients with essential thrombocythemia should be encouraged to participate in preconception counseling for risk assessment and to initiate prophylactic anticoagulation as soon as possible.


Asunto(s)
Complicaciones del Embarazo , Trombocitemia Esencial , Tromboembolia Venosa , Femenino , Humanos , Embarazo , Vena Porta/diagnóstico por imagen , Resultado del Embarazo , Trombocitemia Esencial/complicaciones , Trombocitemia Esencial/tratamiento farmacológico , Trombocitemia Esencial/diagnóstico , Tromboembolia Venosa/complicaciones , Adulto
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...