Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Clin Anesth ; 83: 110982, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36265267

RESUMO

STUDY OBJECTIVE: While supplemental O2 inhalation corrects hypoxemia, its effect on post-anesthesia ventilation remains unknown. This pilot trial tested the hypothesis that hyperoxia increases the time spent with a transcutaneous PCO2 (TcPCO2) > 45 mmHg, compared with standard O2 supplementation. DESIGN: Single-blinded, parallel two-arm randomized pilot trial. SETTING: University hospital. PATIENTS: 20 patients undergoing robotic-assisted laparoscopic nephrectomy. MEASUREMENTS: After institutional approval and informed consent, patients were randomized to receive O2 titrated to arterial saturation (SpO2): 90-94% (Conservative O2, N =10), or to SpO2 > 96% (Liberal O2, N = 10) for up to 90 min after anesthesia. Continuous TcPCO2, respiratory inductance plethysmography (RIP), and SpO2, were recorded. We calculated the percentage of time at TcPCO2 > 45 mmHg for each patient and compared the two groups using analysis of covariance, adjusting for sex, age, and body mass index. We also estimated the sample size required to detect the between-group difference observed in this pilot trial. RIP signals were used to calculate apnea/hypopnea index (AHI), which was then compared between two groups. MAIN RESULTS: The mean percentage of time with a TcPCO2 > 45 mmHg was 80.6% for the Conservative O2 (N=9) and 61.2% for the Liberal O2 (N=10) group [between-group difference of 19.4% (95% CI: -18.7% to 57.6%), P = 0.140]. With an observed effect size of 0.73, we estimated that 30 participants per group are required, to demonstrate this difference with a power of 80% at a two-sided alpha of 5%. Means SpO2 were 94.5% and 99.9% for the Conservative O2 and the Liberal O2 groups, respectively. AHI was significantly higher in the Conservative O2, compared with the Liberal O2 group (median AHI: 16 vs. 3; P = 0.0014). CONCLUSIONS: Hyperoxia in the post-anesthesia period reduced the time spent at TcPCO2 > 45 mmHg and significantly decreased AHI, while mean SpO2 ranged inside the a priori defined limits. TRIAL REGISTRATION: ClinicalTrials.gov identifier: NCT04723433.


Assuntos
Hiperóxia , Humanos , Oxigenoterapia , Projetos Piloto , Oxigênio , Anestesia Geral/efeitos adversos
2.
J Sleep Res ; 31(4): e13630, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35770626

RESUMO

Obstructive sleep apnea is linked to severe health consequences such as hypertension, daytime sleepiness, and cardiovascular disease. Nearly a billion people are estimated to have obstructive sleep apnea with a substantial economic burden. However, the current diagnostic parameter of obstructive sleep apnea, the apnea-hypopnea index, correlates poorly with related comorbidities and symptoms. Obstructive sleep apnea severity is measured by counting respiratory events, while other physiologically relevant consequences are ignored. Furthermore, as the clinical methods for analysing polysomnographic signals are outdated, laborious, and expensive, most patients with obstructive sleep apnea remain undiagnosed. Therefore, more personalised diagnostic approaches are urgently needed. The Sleep Revolution, funded by the European Union's Horizon 2020 Research and Innovation Programme, aims to tackle these shortcomings by developing machine learning tools to better estimate obstructive sleep apnea severity and phenotypes. This allows for improved personalised treatment options, including increased patient participation. Also, implementing these tools will alleviate the costs and increase the availability of sleep studies by decreasing manual scoring labour. Finally, the project aims to design a digital platform that functions as a bridge between researchers, patients, and clinicians, with an electronic sleep diary, objective cognitive tests, and questionnaires in a mobile application. These ambitious goals will be achieved through extensive collaboration between 39 centres, including expertise from sleep medicine, computer science, and industry and by utilising tens of thousands of retrospectively and prospectively collected sleep recordings. With the commitment of the European Sleep Research Society and Assembly of National Sleep Societies, the Sleep Revolution has the unique possibility to create new standardised guidelines for sleep medicine.


Assuntos
Distúrbios do Sono por Sonolência Excessiva , Apneia Obstrutiva do Sono , Humanos , Polissonografia , Estudos Retrospectivos , Sono , Apneia Obstrutiva do Sono/diagnóstico , Apneia Obstrutiva do Sono/terapia
3.
Sleep Adv ; 3(1): zpac011, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35601080

RESUMO

Study Objectives: Along with multiple chronic comorbidities, sleep disorders are prevalent in people living with human immunodeficiency virus (HIV) infection. The goal of this study was to establish methods for assessing sleep quality and breathing-related disorders using self-applied home polysomnography in people with and without HIV. Methods: Self-applied polysomnography was conducted on 960 participants in the Multicenter AIDS Cohort Study (MACS) using the Nox A1 recorder to collect data on the frontal electroencephalogram (EEG), bilateral electrooculograms, and a frontalis electromyogram during sleep. Breathing patterns were characterized using respiratory inductance plethysmography bands and pulse oximetry. Continuous recordings of the electrocardiogram were also obtained. All studies were scored centrally for sleep stages and disordered breathing events. Results: Successful home polysomnography was obtained in 807 of 960 participants on the first attempt and 44 participants on the second. Thus, a successful polysomnogram was obtained in 851 (88.6%) of the participants. Reasons for an unsuccessful study included less than 3 h of data on oximetry (34.6%), EEG (28.4%), respiratory inductance plethysmography (21.0%), or two or more of these combined (16.0%). Of the successful studies (N = 851), signal quality was rated as good, very good, or excellent in 810 (95.2%). No temporal trends in study quality were noted. Independent correlates of an unsuccessful study included black race, current smoking, and cocaine use. Conclusions: Home polysomnography was successfully completed in the MACS demonstrating its feasibility in a community cohort. Given the burden of in-lab polysomnography, the methods described herein provide a cost-effective alternative for collecting sleep data in the home.

4.
Sleep Breath ; 25(3): 1535-1541, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33411184

RESUMO

PURPOSE: Evaluate the effect of respiratory inductance plethysmography (RIP) belt design on the reliability and quality of respiratory signals. A comparison of cannula flow to disposable cut-to-fit, semi-disposable folding and disposable RIP belts was performed in clinical home sleep apnea testing (HSAT) studies. METHODS: This was a retrospective study using clinical HSAT studies. The signal reliability of cannula, thorax, and abdomen RIP belts was determined by automatically identifying periods during which the signals did not represent respiratory airflow and breathing movements. Results were verified by manual scoring. RIP flow quality was determined by examining the correlation between the RIP flow and cannula flow when both signals were considered reliable. RESULTS: Of 767 clinical HSAT studies, mean signal reliability of the cut-to-fit, semi-disposable, and disposable thorax RIP belts was 83.0 ± 26.2%, 76.1 ± 24.4%, and 98.5 ± 9.3%, respectively. The signal reliability of the cannula was 92.5 ± 16.1%, 87.0 ± 23.3%, and 85.5 ± 24.5%, respectively. The automatic assessment of signal reliability for the RIP belts and cannula flow had a sensitivity of 50% and a specificity of 99% compared with manual assessment. The mean correlation of cannula flow to RIP flow from the cut-to-fit, semi-disposable, and disposable RIP belts was 0.79 ± 0.24, 0.52 ± 0.20, and 0.86 ± 0.18, respectively. CONCLUSION: The design of RIP belts affects the reliability and quality of respiratory signals. The disposable RIP belts that had integrated contacts and did not fold on top of themselves performed the best. The cut-to-fit RIP belts were most likely to be unreliable, and the semi-disposable folding belts produced the lowest-quality RIP flow signals compared to the cannula flow signal.


Assuntos
Desenho de Equipamento , Pletismografia/instrumentação , Respiração , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...