Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Turk J Med Sci ; 51(4): 2087-2094, 2021 08 30.
Artigo em Inglês | MEDLINE | ID: mdl-33992038

RESUMO

Background/aim: The purpose of this study was to determine the effects of the supplemental feeding tube device (SFTD) and bottle methods on weight gain, transition to full breastfeeding, breastfeeding success, and duration of discharge in preterm infants. Materials and methods: This randomized controlled trial was conducted with a total of 46 preterm infants including 23 infants in study (SFTD) and control (bottle) groups. An information form, an infant follow-up form for feeding, and LATCH breastfeeding assessment instrument were used to collect the data. Results: The gestation week of the infants in the study group was 31.22 ± 2.76, and in the control group it was 30.52 ± 2.47. The birth weight of the infants in the study group was 1586.3 ± 525.35 g and 1506.09 ± 454.77 g in the control group. The daily weight gain of the infants was 24.09 ± 15.21 g in the study group and 27.17 ± 17.63 g in the control group. The infants in the study group (4.70 ± 2.44 days) transitioned to full breastfeeding earlier than those in the control group (6.00 ± 4.10 days). LATCH 2nd measurement scores were significantly higher in both groups than LATCH 1st measurement scores (p < 0.01). Although it was not statistically significant (p > 0.05), the infants in the study group (10.22 ± 5.20 days) were discharged earlier than those in the control group (13.48 ± 8.78 days). Conclusion: The SFTD and bottle methods were determined to be similar in terms of daily weight gain, transition to full breastfeeding, breastfeeding success, and duration of hospitalization.


Assuntos
Métodos de Alimentação , Recém-Nascido Prematuro , Aleitamento Materno , Estudos de Casos e Controles , Feminino , Humanos , Lactente , Recém-Nascido , Unidades de Terapia Intensiva Neonatal , Masculino , Aumento de Peso
2.
J Pediatr Nurs ; 53: e156-e163, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32253092

RESUMO

PURPOSE: To conduct Turkish validity and reliability study of the MISSCARE Survey-Pediatric version identifying the missed nursing care in pediatric units and its reasons. DESIGN AND METHODS: The sample of this methodological study consisted of 222 nurses working in pediatric units. The study was conducted in three training and research hospitals and one university hospital. In the Turkish adaptation of the survey, confirmatory and explanatory factor analyses were performed within the context of language validity, content validity, and construct validity. In the reliability analyses of the survey, Cronbach's alpha for internal consistency analysis and intraclass correlation analysis for test re-test were used. RESULTS: The language validity of the survey was conducted by expert linguists. Content validity index was calculated as 0.88 for section A and 0.90 for section B. Turkish version consisting of three factors and 16 items for section B of the survey met the construct validity. In reliability analyses it was determined that Cronbach's alpha values were between 0.82 and 0.88 in subscales of the survey and Intraclass Correlation Coefficient values were between 0.52 and 0.65 in subscales of the survey and 0.64 in overall survey. CONCLUSION: In the Turkish version of MISSCARE Survey-Pediatric version, the section A with 29 items and the section B with 16 items were valid and reliable. PRACTICE IMPLICATIONS: The survey is a valid and reliable tool for intercultural studies revealing the nursing care activities missed by nurses working in pediatric clinics and the reasons for such activities.


Assuntos
Idioma , Criança , Análise Fatorial , Humanos , Reprodutibilidade dos Testes , Inquéritos e Questionários
3.
J Pediatr Nurs ; 44: e13-e19, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30360938

RESUMO

PURPOSE: To test the validity and reliability of an infiltration scale in infants that was adapted for the pediatric population. DESIGN AND METHODS: The present study is an observational prospective study. The study was conducted in a NICU of a training and research hospital in Istanbul. Data were obtained from131 infants who were <4 kg. Language validity of the scale was tested by expert linguists. The comments of fourteen experts were taken for content validity. For reliability testing, three observers independently evaluated the scale. RESULTS: Infiltration developed in 28.72% of infants who were examined and grade 2 infiltration was detected at rate of 58%. The content validity index of the scale was 0.93. The Cronbach's alpha was calculated as 0.96 in the agreement of the three observer nurses' evaluations. A highly significant association was detected between the coherence of Cohen's kappa values and Intra-Class Correlation coefficient (ICC) (p < 0.01). CONCLUSIONS: The infiltration scale is a valid and reliable scale in infants. The validity and reliability of the scale has been verified and may be used in the identification of infiltration in infant gestational age between 24 and 39 weeks and weighing <4 kg. PRACTICE IMPLICATIONS: The infiltration scale for infants is a valid and reliable tool for monitoring catheter sites in the prevention of complications such as infiltration due to PIV therapy practices in neonatal intensive care units.


Assuntos
Peso ao Nascer , Cateterismo Periférico , Cateteres de Demora , Nutrição Parenteral/métodos , Feminino , Hospitais de Ensino , Humanos , Recém-Nascido , Infusões Intravenosas , Unidades de Terapia Intensiva Neonatal , Masculino , Estudos Prospectivos , Reprodutibilidade dos Testes , Medição de Risco , Resultado do Tratamento , Turquia
4.
J Spec Pediatr Nurs ; 22(3)2017 07.
Artigo em Inglês | MEDLINE | ID: mdl-28407443

RESUMO

PURPOSE: Noise, an environmental stimulus, is especially important in the neurobehavioral development of newborns and brain development of infants at high risk. Conditions in the neonatal intensive care units (NICUs) may cause certain sensory stimuli that are not appropriate for the development of newborns, especially preterm infants. This study was conducted in order to determine noise levels in the NICU and to evaluate the effect of training provided for noise control. DESIGN AND METHODS: This study was conducted as a pretest-posttest quasiexperimental design between September and November 2014 in a 30-bed NICU of a tertiary hospital in Istanbul. A sample group consisting of 30 people (26 nurses, 4 care workers). Noise measurement devices were used in the Training Program of Noise Control. RESULTS: Of the health professionals, 96.7% were women, 86.7% were nurses, and 63.3% were university graduates. Some 36.7% of the health professionals had worked within the unit for more than 5 years. Noise measurements of full implementations were made over three 24-h periods. Noise measurements were taken before and after the training on Monday, Friday, and Sunday. Noise levels after training diminished in all three measurements, and the decrease was found statistically significant (P < 0.01). PRACTICE IMPLICATIONS: Planned Noise Control Training for health professionals who work in NICUs is an effective way of reducing noise. We recommend that this training should be given to NICU health professionals and noise levels should be determined through measurements at specific times.


Assuntos
Atitude do Pessoal de Saúde , Desenvolvimento Infantil/fisiologia , Pessoal de Saúde/educação , Pessoal de Saúde/psicologia , Recém-Nascido Prematuro/crescimento & desenvolvimento , Unidades de Terapia Intensiva Neonatal/organização & administração , Ruído/prevenção & controle , Adulto , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Pessoa de Meia-Idade , Turquia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...