Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Acta Anaesthesiol Scand ; 60(1): 26-35, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26235391

RESUMO

BACKGROUND: Venous admixture from atelectasis and airway closure impedes oxygenation during general anaesthesia. We tested the hypothesis that continuous positive airway pressure (CPAP) during pre-oxygenation and reduced fraction of inspiratory oxygen (FIO2 ) during emergence from anaesthesia can improve oxygenation in patients with obesity undergoing laparoscopic surgery. METHODS: In the intervention group (n = 20, median BMI 41.9), a CPAP of 10 cmH2 O was used during pre-oxygenation and induction of anaesthesia, but no CPAP was used in the control group (n = 20, median BMI 38.1). During anaesthesia, all patients were ventilated in volume-controlled mode with an FIO2 of 0.4 and a positive end-expiratory pressure (PEEP) of 10 cmH2 O. During emergence, before extubation, the control group was given an FIO2 of 1.0 and the intervention group was divided into two subgroups, which were given an FIO2 of 1.0 or 0.31. Oxygenation was assessed perioperatively by the estimated venous admixture (EVA). RESULTS: The median EVA before pre-oxygenation was about 8% in both groups. During anaesthesia after intubation, the median EVA was 8.2% in the intervention vs. 13.2% in the control group (P = 0.048). After CO2 pneumoperitoneum, the median EVA was 8.4% in the intervention vs. 9.9% in the control group (P > 0.05). One hour post-operatively, oxygenation had deteriorated in patients given an FIO2 of 1.0 during emergence but not in patients given an FIO2 of 0.31. CONCLUSIONS: A CPAP of 10 cmH2 O during pre-oxygenation and induction, followed by PEEP after intubation, seemed to preserve oxygenation during anaesthesia. Post-operative oxygenation depended on the FIO2 used during emergence.


Assuntos
Laparoscopia/métodos , Obesidade/fisiopatologia , Consumo de Oxigênio , Respiração Artificial , Adulto , Anestesia , Gasometria , Índice de Massa Corporal , Pressão Positiva Contínua nas Vias Aéreas , Feminino , Humanos , Cuidados Intraoperatórios , Masculino , Pessoa de Meia-Idade , Obesidade/cirurgia , Pneumoperitônio Artificial , Respiração com Pressão Positiva , Estudos Prospectivos , Método Simples-Cego , Resultado do Tratamento , Adulto Jovem
2.
Acta Anaesthesiol Scand ; 55(1): 75-81, 2011 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-21039356

RESUMO

BACKGROUND: atelectasis is a common consequence of pre-oxygenation with 100% oxygen during induction of anaesthesia. Lowering the oxygen level during pre-oxygenation reduces atelectasis. Whether this effect is maintained during anaesthesia is unknown. METHODS: during and after pre-oxygenation and induction of anaesthesia with 60%, 80% or 100% oxygen concentration, followed by anaesthesia with mechanical ventilation with 40% oxygen in nitrogen and positive end-expiratory pressure of 3 cmH(2) O, we used repeated computed tomography (CT) to investigate the early (0-14 min) vs. the later time course (14-45 min) of atelectasis formation. RESULTS: in the early time course, atelectasis was studied awake, 4, 7 and 14 min after start of pre-oxygenation with 60%, 80% or 100% oxygen concentration. The differences in the area of atelectasis formation between awake and 7 min and between 7 and 14 min were significant, irrespective of oxygen concentration (P<0.05). During the late time course, studied after pre-oxygenation with 80% oxygen, the differences in the area of atelectasis formation between awake and 14 min, between 14 and 21 min, between 21 and 28 min and finally between 21 and 45 min were all significant (P<0.05). CONCLUSION: formation of atelectasis after pre-oxygenation and induction of anaesthesia is oxygen and time dependent. The benefit of using 80% oxygen during induction of anaesthesia in order to reduce atelectasis diminished gradually with time.


Assuntos
Anestesia/efeitos adversos , Complicações Intraoperatórias/induzido quimicamente , Complicações Intraoperatórias/metabolismo , Consumo de Oxigênio/fisiologia , Oxigênio/administração & dosagem , Oxigênio/efeitos adversos , Atelectasia Pulmonar/induzido quimicamente , Adulto , Feminino , Humanos , Histerectomia , Pulmão/diagnóstico por imagem , Pessoa de Meia-Idade , Modelos Estatísticos , Respiração com Pressão Positiva , Atelectasia Pulmonar/diagnóstico por imagem , Respiração Artificial , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...