Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Int Ophthalmol ; 44(1): 137, 2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38489070

RESUMO

PURPOSE: To evaluate the thickness of anterior sclera and corneal layers in patients with systemic sclerosis. METHODS: The present cross-sectional study included 41 patients with systemic sclerosis and 41 age- and gender-matched healthy controls. The study and control groups were compared in terms of the thickness of anterior sclera, corneal epithelium, Bowman's layer, corneal stroma, and Descemet's membrane-endothelium complex. The thickness measurements were obtained using the anterior segment module of spectral-domain optical coherence tomography. RESULTS: The thickness of anterior sclera, corneal epithelium, Bowman's layer, and Descemet's membrane-endothelium complex were similar in the patients with systemic sclerosis and healthy controls (P > 0.05). Total corneal thickness at the apex was 511.1 ± 33.5 µm in the systemic sclerosis group and 528.4 ± 29.5 µm in the control group (P = 0.015). The corneal stroma was thinner in the systemic sclerosis patients compared to the healthy controls (P = 0.02). CONCLUSIONS: The corneal stroma was thinner in the patients with systemic sclerosis compared to that of healthy controls, while the thickness of the anterior sclera was similar in both groups.


Assuntos
Epitélio Corneano , Esclera , Humanos , Estudos Transversais , Córnea , Substância Própria , Tomografia de Coerência Óptica/métodos
4.
Ocul Immunol Inflamm ; 25(3): 328-332, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26903201

RESUMO

PURPOSE: To investigate the role of CXCR4 and cyclooxygenase-2 in pterygium recurrence. METHODS: A total of 18 primary and 9 recurrent pterygium samples were analyzed. Immunohistochemical staining using primary antibodies against cyclooxygenase-2 and CXCR4 was performed. The cyclooxygenase-2 and CXCR4 expressing cells were calculated separately on the epithelium and stroma. In addition, a correlation between the area of pterygium and CXCR4 and cyclooxygenase-2 levels was investigated. RESULTS: In the primary pterygium group, cyclooxygenase-2 staining was more intense in the epithelium and more dominant in the stroma of the recurrence samples. The CXCR4 expression was more intense in the stroma of both groups. The highest CXCR4 expression was observed in the recurrent pterygium group. There was a strong correlation between the area of pterygium and CXCR4 and cyclooxygenase-2 of stroma. CONCLUSIONS: CXCR4 and cyclooxygenase-2 may play an important role in the recurrence of pterygium.


Assuntos
Ciclo-Oxigenase 2/metabolismo , Pterígio/metabolismo , Receptores CXCR4/metabolismo , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Pterígio/diagnóstico , Pterígio/cirurgia , Recidiva , Adulto Jovem
5.
Int J Ophthalmol ; 8(3): 540-3, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26086004

RESUMO

AIM: To evaluate the intraocular pressure (IOP) measurements by Icare rebound tonometer over a contact lens in comparison with Goldmann applanation tonometry (GAT). METHODS: Fifty patients using contact lens were included in this study. One of the eyes of the patients was selected randomly and their IOP were measured by rebound tonometer with and without contact lens (RTCL, RT respectively) and by GAT, as well as their central corneal thickness (CCT) by optical pachymeter. The results of both methods were compared by correlation analysis, general linear method repeated measure and Bland-Altman analysis. RESULTS: Mean IOP values measured by RTCL, RT and GAT were 15.68±3.7, 14.50±3.4 and 14.16±2.8 (P<0.001), respectively. Mean IOP by RTCL was significantly higher than the measurements implemented by RT and GAT (P<0.001), while there was no difference between the measurements by GAT and RT (P=0.629). There was a good level of positive correlation between GAT and RTCL as well as RT (r=0.786 P<0.001, r=0.833 P<0.001, respectively). We have observed that CCT increase did not show any correlation with the differences of the measurements between RTCL and RT (P=0.329), RTCL and GAT (P=0.07) as well as RT and GAT (P=0.189) in linear regression model. CONCLUSION: The average of the measurements over contact lens by rebound tonometer was found to be higher than what was measured by GAT. Although this difference is statistically significant, it may be clinically negligible in the normal population.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...