Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Pharm Pharm Sci ; 27: 12398, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38577255

RESUMO

Bioequivalence (BE) studies are considered the standard for demonstrating that the performance of a generic drug product in the human body is sufficiently similar to that of its comparator product. The objective of this article is to describe the recommendations from participating Bioequivalence Working Group for Generics (BEWGG) members of the International Pharmaceutical Regulators Programme (IPRP) regarding the conduct and acceptance criteria for BE studies of immediate release solid oral dosage forms. A survey was conducted among BEWGG members regarding their BE recommendations and requirements related to study subjects, study design, sample size, single or multiple dose administration, study conditions (fasting or fed), analyte to be measured, selection of product strength, drug content, handling of endogenous substances, BE acceptance criteria, and additional design aspects. All members prefer conducting single dose cross-over designed studies in healthy subjects with a minimum of 12 subjects and utilizing the parent drug data to assess BE. However, differences emerged among the members when the drug's pharmacokinetics and pharmacodynamics become more complex, such that the study design (e.g., fasting versus fed conditions) and BE acceptance criteria (e.g., highly variable drugs, narrow therapeutic index drugs) may be affected. The survey results and discussions were shared with the ICH M13 Expert Working Group (EWG) and played an important role in identifying and analyzing gaps during the harmonization process. The draft ICH M13A guideline developed by the M13 EWG was endorsed by ICH on 20 December 2022, under Step 2.


Assuntos
Medicamentos Genéricos , Projetos de Pesquisa , Humanos , Equivalência Terapêutica
2.
J Pharm Pharm Sci ; 25: 323-339, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36251699

RESUMO

The safety and efficacy of a generic product are partly based on demonstrating bioequivalence to the innovator product; however, when the innovator product is no longer available as a comparator product, a survey conducted within the Bioequivalence Working Group for Generics (BEWGG) of the International Pharmaceutical Regulators Programme (IPRP) indicated that the criteria for selecting an alternative comparator product varies. For most members of the BEWGG, an existing marketed generic that was approved based on a comparison with the locally registered innovator product can be used, contingent on criteria that ranges from allowing any generic to be used, to allowing only specific criteria-defined generics to be used. Notwithstanding the acceptability of a generic as an alternative comparator, it is not always the preferred comparator for several jurisdictions. Some jurisdictions require the use of a locally sourced alternative innovator comparator (e.g., the same medicinal ingredient manufactured by a different company) or a foreign innovator comparator. Unlike the other members of the BEWGG, the European Union (EU) has no such options available, rather mechanisms are in place to allow manufacturers to develop a new comparator. The criteria described herein regarding the use of an alternative comparator product can also be applied to scenarios where a specific strength of a series of strengths or an innovative fixed dose combination are discontinued. The results of the survey demonstrate that while criteria for selecting alternative comparator products are not harmonized among the BEWGG participants, the common concern for all jurisdictions is to select a comparator product that meets the safety and efficacy standards of the original innovator product.


Assuntos
Medicamentos Genéricos , Humanos , Inquéritos e Questionários , Equivalência Terapêutica
3.
J Pharm Pharm Sci ; 24: 548-562, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34706215

RESUMO

This article describes an overview of waivers of in vivo bioequivalence studies for additional strengths in the context of the registration of modified release generic products and is a follow-up to the recent publication for the immediate release solid oral dosage forms. The current paper is based on a survey among the participating members of the Bioequivalence Working Group for Generics (BEWGG) of the International Pharmaceutical Regulators Program (IPRP) regarding this topic. Most jurisdictions consider the extrapolation of bioequivalence results obtained with one (most sensitive) strength of a product series as less straightforward for modified release products than for immediate release products. There is consensus that modified release products should demonstrate bioequivalence not only in the fasted state but also in the fed state, but differences exist regarding the necessity of additional multiple dose studies. Fundamental differences between jurisdictions are revealed regarding requirements on the quantitative composition of different strengths and the differentiation of single and multiple unit dosage forms. Differences in terms of in vitro dissolution requirements are obvious, though these are mostly related to possible additional comparative investigations rather than regarding the need for product-specific methods. As with the requirements for immediate release products, harmonization of the various regulations for modified release products is highly desirable to conduct the appropriate studies from a scientific point of view, thus ensuring therapeutic equivalence.


Assuntos
Administração Oral , Aprovação de Drogas , Medicamentos Genéricos/normas , Equivalência Terapêutica , Preparações de Ação Retardada , Aprovação de Drogas/métodos , Medicamentos Genéricos/administração & dosagem , Medicamentos Genéricos/uso terapêutico , Humanos
4.
J Pharm Pharm Sci ; 24: 113-126, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33734975

RESUMO

The requirements to waive in vivo bioequivalence studies for immediate release solid oral dosage forms based on the Biopharmaceutics Classifications System (BCS) are well known, and biowaivers[1] for other types of oral dosage forms based on pre-defined criteria may also be acceptable. Similarly, biowaivers for dosage forms such as injectable products may also be allowed if certain criteria are met. The current paper summarises the biowaiver requirements for oral solutions and suspensions, soft gelatin capsules and injectable products (intravenous injections, subcutaneous and intramuscular injections, emulsions for injection and micellar solutions for injection) among the participants of the Bioequivalence Working Group for Generics (BEWGG) of the International Pharmaceutical Regulators Programme (IPRP). A review of the requirements indicated that there was a trend towards convergence when the dosage form became less complex; however, the most common approach used by each of the jurisdictions was a case-by-case approach given that most jurisdictions do not have well defined guidelines to support all possible scenarios. Even in the simplest case of intravenous solutions, the acceptability of qualitative changes in excipients differ between the IPRP members.  Notwithstanding the differences, the dissemination of the information is a first step towards regulatory convergence regarding biowaivers for certain dosage forms and should be useful for pharmaceutical companies currently developing generic medicinal products for IPRP jurisdictions.


Assuntos
Medicamentos Genéricos/administração & dosagem , Administração Oral , Humanos , Soluções , Inquéritos e Questionários , Equivalência Terapêutica
5.
Environ Toxicol Pharmacol ; 34(2): 223-227, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22554863

RESUMO

The aim of this research has been to determine the biperiden hydrochloride permeability in Caco-2 model, in order to classify it based on the Biopharmaceutics Classification System (BCS). The World Health Organization (WHO) as well as many other authors have provisionally assigned the drug as BCS class I (high solubility-high permeability) or III (high solubility-low permeability), based on different methods. We determined biperiden BCS class by comparing its permeability to 5 pre-defined compounds: atenolol and ranitidine hydrochloride (low permeability group) and metoprolol tartrate, sodium naproxen and theophylline (high permeability group). Since biperiden permeability was higher than those obtained for high permeability drugs, we classified it as a BCS class I compound. On the other hand, as no differences were obtained for permeability values when apical to basolateral and basolateral to apical fluxes were studied, this drug cannot act as a substrate of efflux transporters. As a consequence of our results, we suggest that the widely used antiparkinsonian drug, biperiden, should be candidate for a waiver of in vivo bioequivalence studies.


Assuntos
Antiparkinsonianos/metabolismo , Biperideno/metabolismo , Antiparkinsonianos/classificação , Transporte Biológico , Biofarmácia/classificação , Biperideno/classificação , Células CACO-2 , Humanos , Permeabilidade , Solubilidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...