Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Heart Fail Rev ; 26(5): 1063-1080, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-32338334

RESUMO

Heart failure (HF) patients represent one of the most prevalent as well as one of the most fragile population encountered in the cardiology and internal medicine departments nowadays. Estimated to account for around 26 million people worldwide, diagnosed patients present a poor prognosis and quality of life with a clinical history accompanied by repeated hospital admissions caused by an exacerbation of their chronic condition. The frequent hospitalizations and the extended hospital stays mean an extremely high economic burden for healthcare institutions. Meanwhile, the number of chronically diseased and elderly patients is continuously rising, and a lack of specialized physicians is evident. To cope with this health emergency, more efficient strategies for patient management, more accurate diagnostic tools, and more efficient preventive plans are needed. In recent years, telemonitoring has been introduced as the potential answer to solve such needs. Different methodologies and devices have been progressively investigated for effective home monitoring of cardiologic patients. Invasive hemodynamic devices, such as CardioMEMS™, have been demonstrated to be reducing hospitalizations and mortality, but their use is however restricted to limited cases. The role of external non-invasive devices for remote patient monitoring, instead, is yet to be clarified. In this review, we summarized the most relevant studies and devices that, by utilizing non-invasive telemonitoring, demonstrated whether beneficial effects in the management of HF patients were effective.


Assuntos
Insuficiência Cardíaca , Telemedicina , Idoso , Doença Crônica , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Hospitalização , Humanos , Monitorização Fisiológica , Qualidade de Vida
2.
J Cardiovasc Magn Reson ; 22(1): 79, 2020 11 30.
Artigo em Inglês | MEDLINE | ID: mdl-33256761

RESUMO

BACKGROUND: Cardiovascular magnetic resonance (CMR) strain imaging is an established technique to quantify myocardial deformation. However, to what extent left ventricular (LV) systolic strain, and therefore LV mechanics, reflects classical hemodynamic parameters under various inotropic states is still not completely clear. Therefore, the aim of this study was to investigate the correlation of LV global strain parameters measured via CMR feature tracking (CMR-FT, based on conventional cine balanced steady state free precession (bSSFP) images) with hemodynamic parameters such as cardiac index (CI), cardiac power output (CPO) and end-systolic elastance (Ees) under various inotropic states. METHODS: Ten anaesthetized, healthy Landrace swine were acutely instrumented closed-chest and transported to the CMR facility for measurements. After baseline measurements, two steps were performed: (1) dobutamine-stress (Dobutamine) and (2) verapamil-induced cardiovascular depression (Verapamil). During each protocol, CMR images were acquired in the short axisand apical 2Ch, 3Ch and 4Ch views. MEDIS software was utilized to analyze global longitudinal (GLS), global circumferential (GCS), and global radial strain (GRS). RESULTS: Dobutamine significantly increased heart rate, CI, CPO and Ees, while Verapamil decreased them. Absolute values of GLS, GCS and GRS accordingly increased during Dobutamine infusion, while GLS and GCS decreased during Verapamil. Linear regression analysis showed a moderate correlation between GLS, GCS and LV hemodynamic parameters, while GRS correlated poorly. Indexing global strain parameters for indirect measures of afterload, such as mean aortic pressure or wall stress, significantly improved these correlations, with GLS indexed for wall stress reflecting LV contractility as the clinically widespread LV ejection fraction. CONCLUSION: GLS and GCS correlate accordingly with LV hemodynamics under various inotropic states in swine. Indexing strain parameters for indirect measures of afterload substantially improves this correlation, with GLS being as good as LV ejection fraction in reflecting LV contractility. CMR-FT-strain imaging may be a quick and promising tool to characterize LV hemodynamics in patients with varying degrees of LV dysfunction.


Assuntos
Ventrículos do Coração/diagnóstico por imagem , Hemodinâmica , Imagem Cinética por Ressonância Magnética , Função Ventricular Esquerda , Animais , Fenômenos Biomecânicos , Bloqueadores dos Canais de Cálcio/farmacologia , Cardiotônicos/farmacologia , Feminino , Ventrículos do Coração/efeitos dos fármacos , Ventrículos do Coração/fisiopatologia , Hemodinâmica/efeitos dos fármacos , Valor Preditivo dos Testes , Sus scrofa , Sístole , Fatores de Tempo , Função Ventricular Esquerda/efeitos dos fármacos
3.
Int J Cardiovasc Imaging ; 36(9): 1761-1769, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32409978

RESUMO

Right ventricular biopsy represents the gold standard for the assessment of myocardial fibrosis and collagen content. This invasive technique, however, is accompanied by perioperative complications and poor reproducibility. Extracellular volume (ECV) measured through cardiovascular magnetic resonance (CMR) has emerged as a valid surrogate method to assess fibrosis non-invasively. Nonetheless, ECV provides an overestimation of collagen concentration since it also considers interstitial space. Our study aims to investigate the feasibility of estimating total collagen volume (TCV) through CMR by comparing it with the TCV measured at histology. Seven healthy Landrace pigs were acutely instrumented closed-chest and transported to the MRI facility for measurements. For each protocol, CMR imaging at 3T was acquired. MEDIS software was used to analyze T1 mapping and ECV for both the left ventricular myocardium (LVmyo) and left ventricular septum (LVseptum). ECV was then used to estimate TCVCMR at LVmyo and LVseptum following previously published formulas. Tissues were prepared following an established protocol and stained with picrosirius red to analyze the TCVhisto in LVmyo and LVseptum. TCV measured at LVmyo and LVseptum with both histology (8 ± 5 ml and 7 ± 3 ml, respectively) and T1-Mapping (9 ± 5 ml and 8 ± 6 ml, respectively) did not show any regional differences. TCVhisto and TCVCMR showed a good level of data agreement by Bland-Altman analysis. Estimation of TCV through CMR may be a promising way to non-invasively assess myocardial collagen content and may be useful to track disease progression or treatment response.


Assuntos
Colágeno/análise , Cardiopatias/diagnóstico por imagem , Coração/diagnóstico por imagem , Imagem Cinética por Ressonância Magnética , Miocárdio/química , Animais , Biópsia , Estudos de Viabilidade , Fibrose , Cardiopatias/metabolismo , Cardiopatias/patologia , Miocárdio/patologia , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Sus scrofa
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...