Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Micromachines (Basel) ; 14(11)2023 Oct 30.
Artigo em Inglês | MEDLINE | ID: mdl-38004875

RESUMO

The rapid growth of wireless communication systems has led to high demand for the design of microwave/millimeter components with multiband characteristics, high performance, and ease of integration with other devices [...].

2.
Micromachines (Basel) ; 14(7)2023 Jul 16.
Artigo em Inglês | MEDLINE | ID: mdl-37512743

RESUMO

This article presents an application of a grounded substrate-based metasurface for hosting dielectric resonators (DRs), enabling a wide dual-band circularly polarized (CP) operation. The antenna structure comprises centrally positioned rectangular DRs, one above the other, along with a 7 × 7 square-slotted metasurface. The metasurface and DRs are hosted above a grounded substrate, which is fed through a single coaxial feed placed at a specific angle, employing a modified upper probe of the coaxial feed. The proposed hybrid technique utilizes the combined benefits of the feed angle and a well-matched metasurface, resulting in performance improvement. Notably, a measured impedance bandwidth of 88.1% for |S11| is achieved within the frequency range of 4.0 GHz to 10.3 GHz. Furthermore, the antenna design exhibits two overlapping measured 3-dB axial ratio (AR) bandwidths: 23.62% from 4.25 GHz to 5.4 GHz and 5.12% from 7.6 GHz to 8 GHz. The peak gain of the antenna is measured at 8.4 dBic. Consequently, this innovative single-feed antenna design, characterized by its compact profile, holds significant potential for realizing multi-band operations. Furthermore, the developed antenna is well-suited for deployment in indoor radio links and INSAT applications.

3.
Sensors (Basel) ; 23(12)2023 Jun 10.
Artigo em Inglês | MEDLINE | ID: mdl-37420650

RESUMO

A split-aperture array (SAA) is an array of sensors or antenna elements in which the array is split into two or more sub-arrays (SAs). Recently proposed SAAs, namely coprime and semi-coprime arrays, offer to attain a small half-power beamwidth (HPBW) with a small number of elements, compared to most conventional unified-aperture arrays, at the cost of reduced peak-to-side-lobe ratio (PSLR). To reduce HPBW and increase PSLR, non-uniform inter-element spacing and excitation amplitudes have proven helpful. However, all the existing arrays and beam-formers suffer increased HPBW, degraded PSLR or both when the main beam is steered away from the broadside. In this paper, we propose staggered beam-steering of SAs, a novel technique for decreasing HPBW. In this technique, we steer the main beams of the SAs of a semi-coprime array to angles slightly different from the desired steering angle. In conjunction with staggered beam-steering of SAs, we have utilized Chebyshev weights to suppress the side lobes. The results show that the beam-widening effect of Chebyshev weights can be mitigated considerably by staggered beam-steering of the SAs. Ultimately, the unified beam-pattern of the whole array offers HPBW and PSLR better than the existing SAAs, uniform and non-uniform linear arrays, especially when the desired steering angle is away from the broadside direction.

4.
Micromachines (Basel) ; 14(6)2023 Jun 13.
Artigo em Inglês | MEDLINE | ID: mdl-37374829

RESUMO

The three-dimensional printed wideband prototype (WBP) was proposed, which is able to enhance the horn feed source by generating a more uniform phase distribution that is obtained after correcting aperture phase values. The noted phase variation obtained without the WBP was 163.65∘ for the horn source only, which was decreased to 19.68∘, obtained after the placement of the WBP at a λ/2 distance above the feed horn aperture. The corrected phase value was observed at 6.25 mm (0.25λ) above the top face of the WBP. The use of a five-layer cubic structure is able to generate the proposed WBP with dimensions of 105 mm × 105 mm × 37.5 mm (4.2λ× 4.2λ× 1.5λ), which can improve directivity and gain by 2.5 dB throughout the operating frequency range with a lower side lobe level. The overall dimension of the 3D printed horn was 98.5 mm × 75.6 mm × 192.6 mm (3.94λ× 3.02λ× 7.71λ), where the 100 % infill value was maintained. The horn was painted with a double layer of copper throughout its surface. In a design frequency of 12 GHz, the computed directivity, gain, side lobe level in H- and E- planes were 20.5 dB, 20.5 dB, -26.5 dB, and -12.4 dB with only a 3D printed horn case and, with the proposed prototype placed above this feed source, these values improved to 22.1 dB, 21.9 dB, -15.5 dB, and -17.5 dB, respectively. The realized WBP was 294 g and the overall system was 448 g in weight, which signifies a light weight condition. The measured return loss values were less than 2, which supports that the WBP has matching behavior over the operating frequency range.

5.
Sensors (Basel) ; 23(6)2023 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-36991594

RESUMO

This paper proposes a concept of dielectric characterization of low-volume liquid samples using the coupling coefficient of filters. The concept is validated through a two-pole substrate integrated waveguide filter in which the liquid under test is mounted on the coupling section between the two resonators. Unlike the conventional resonator perturbation method reported many times in the literature, this technique uses the coupling coefficient for sensing. The liquid sample is collected in a capillary tube and carefully positioned on the coupling section of the filter; the coupling coefficient of the two resonators varies compared to the relative permittivity of the sample; thus, an empirical model is established. The proposed sensor has been tested to compute the permittivity of different alcohols. Binary solutions of ethanol and water have also been characterized to calculate the volume ratio and relative permittivity as a proof-of-concept. The obtained results show that the proposed sensing technique is capable of characterizing a low quantity of liquids (≈44 µL) with good accuracy, and a worst case measured error of only 6.8% is noted. The ease of integration with other circuitry, low cost, reusability with no deterioration, and adaptability of the proposed sensor makes it a suitable choice for the chemical as well as for the pharmaceutical industry.

6.
Micromachines (Basel) ; 13(6)2022 Jun 17.
Artigo em Inglês | MEDLINE | ID: mdl-35744573

RESUMO

This study provides an eight-component multiple-input multiple-output (MIMO) antenna architecture for fifth-generation (5G) mobile communication systems. The single antenna element is comprised of an L-shaped radiating component, an L-shaped parasitic element, and a ground plane with a rectangular slot. The main element with a slot-loaded ground plane helps to draw current from a coaxial feed from the other side of the board, while the parasitic element helps to elongate the current path and improve the impedance of the system. This enables the system to radiate at two different frequency ranges: 3.34-3.7 GHz and 4.67-5.08 GHz, with 360 MHz and 410 MHz bandwidths, respectively. For MIMO configuration, the radiating elements are designed on either side of a 0.8 mm thick FR-4 substrate, allowing space to accommodate a battery, radio frequency (RF) systems and subsystems, and camera and sensor modules. The corner and the middle elements are arranged in such a manner so that they can provide spatial and pattern diversity. Furthermore, at least 12 dB of isolation is established between any two radiating elements. Various MIMO performance parameters were evaluated, e.g., mean effective gain (MEG), channel capacity (CC), envelope correlation coefficient (ECC), realized gain, far-field characteristics, and efficiency. Single- and double-hand mode evaluations were performed to further demonstrate the capability of the proposed MIMO antenna. A prototype of the proposed MIMO antenna was manufactured and assessed to verify the simulated data. The measured and simulated results were found to be in good agreement. On the basis of its performance characteristics, the designed MIMO system could be used in 5G communication systems.

7.
Sensors (Basel) ; 22(12)2022 Jun 13.
Artigo em Inglês | MEDLINE | ID: mdl-35746243

RESUMO

A circularly polarized (CP) multi-input multioutput (MIMO) dielectric resonator (DR) antenna (DRA) with compact size and four ports is implemented. CP radiation was achieved using the deformed DR geometry excited with aperture coupled feeding. A CPDRA with a single and two ports is investigated. The defected ground structure (DGS) was incorporated into the antenna for improving the isolation between the ports. The DGS was incorporated in such a way that the required phase difference between the generated orthogonal degenerate modes is preserved. This concept could be utilized in implementing a compact four-port CP antenna. The MIMO antenna provides a 10 dB impedance bandwidth of 38% (8.5-12.5 GHz) and a 3 dB AR bandwidth of 9.32% (9.2-10.1 GHz). The gain of the implemented antenna was around 6 dBi in the band where CP radiation was achieved. The MIMO performance parameters were calculated, and their values remained within the acceptable limits. The implemented antenna could suitably be used in X-band applications.


Assuntos
Tecnologia sem Fio , Impedância Elétrica , Desenho de Equipamento
8.
Sensors (Basel) ; 22(5)2022 Mar 04.
Artigo em Inglês | MEDLINE | ID: mdl-35271147

RESUMO

This paper presents a metamaterial sensor using a double slit complementary square ring resonator (DS-CSRR) that has been utilized for the measurement of dielectric materials, especially coal powder. The design is optimized for best performance of deep notch depth in transmission coefficient (Magnitude of S21). Sensitivity analysis of transmission coefficient with respect to structure dimensions has been carried out. Metamaterial properties of double negative permitivity and permeability were extracted from the S-parameters of this sensor. The optimized structure is fabricated using low cost FR-4 PCB board. Measured result shows resonance frequency of 4.75 GHz with a deep notch up to -41 dB. Simulated and measured results show good agreement in desired frequency band. For material characterization, first, two known materials are characterized using this metamaterial sensor. Their respective resonances and dielectric constants are known, so the transcendental equation of the sensor is formulated. Afterwards, the proposed sensor is used for dielectric measurement of two types of coal powder, i.e., Anthracite and Bituminous. The measured value of dielectric constant of Anthracite coal is 3.5 and of Bituminous coal is 2.52. This is a simple and effective nondestructive measurement technique for material testing applications.

9.
Micromachines (Basel) ; 13(3)2022 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-35334763

RESUMO

A wideband antenna is proposed based on three-dimensional printing technology. The antenna was designed using the PREPERM 10 material, with permittivity ϵr = 10, where the overall height of the proposed prototype was maintained as 12.83 mm (0.51λ), having a lateral dimension of 60 mm × 60 mm, at an operating frequency of 12 GHz (λ = 25 mm). The proposed antenna achieved a wide frequency bandwidth with a voltage standing-wave ratio (VSWR) of less than two, from 10 GHz to 15 GHz in the Ku-band, where the maximum directivity was 20 dBi over a reflection coefficient bandwidth of 50%. It showed a miniaturized non-uniform metasurface of 2.4λ × 2.4λ × 0.51λ that was placed at 16.5 mm (0.66λ) above the ground plane, which was 2.4λ × 2.4λ × 0.04λ in dimension. Thus, the overall height of the proposed antenna system from the feed source was 29.33 mm (1.17λ). The total weight of the system including the designed structures made of PREPERM 10 and ABS with copper-painted prototypes was 96 g and 79 g, respectively. The measured results were consistent with the simulated results, demonstrating the feasibility and effectiveness of the proposed method.

10.
Micromachines (Basel) ; 14(1)2022 Dec 28.
Artigo em Inglês | MEDLINE | ID: mdl-36677139

RESUMO

In this article, a coding metasurface is specifically designed to switch transmission and reflection functionalities between two different frequency bands for linearly polarized waves within wide incidence angles. A metasurface consists of four metallic patterns, where the middle two structures are inserted to ensure effective performance of transmission and reflection, while the top and bottom patterns are designed based on simultaneously controlling the reflection phase for both polarization states. It has been experimentally demonstrated that the proposed metasurface can convert a transmission band into a complete reflection band (meanwhile, the reflection band is translated into a complete transmission band) by changing the incident polarization state. Highly efficient transmission and reflection characteristics have been achieved from 21.1 to 24.5 GHz as well as from 33.3 to 38.3 GHz, whereas more than 10 dB radar cross-section (RCS) reduction has also been obtained for both TE and TM modes in their respective reflection bands. The performance of the proposed metasurface is well sustained up to 40° oblique incidence. This work will help to open a new aspect in metasurfaces to manipulate the electromagnetic waves at preferable frequency bands to achieve desirable functionalities.

11.
Artigo em Inglês | MEDLINE | ID: mdl-26737528

RESUMO

This paper presents electronically reconfigurable antenna options in healthcare applications. They are suitable for wireless body area network devices operating in the industrial, scientific, and medical (ISM) band at 2.45 GHz and IEEE 802.11 Wireless Local Area Network (WLAN) band at 5 GHz (5.15-5.35 GHz, 5.25-5.35 GHz). Two types of antennas are investigated: Antenna-I has a full ground plane and Antenna-II has a partial ground plane. The proposed antennas provide ISM operation in one mode while in another mode they support 5 GHz WLAN band. Their performance is assessed for body centric wireless communication using a simplified human body model. Antenna sensitivity to the gap between the antenna and the human body is investigated for both modes of each antenna. The proposed antennas exhibit a wide radiation pattern along the body surface to provide wide coverage and their small width (14 mm) makes them suitable for on-body communication in healthcare applications.


Assuntos
Redes de Comunicação de Computadores/instrumentação , Atenção à Saúde/métodos , Modelos Biológicos , Tecnologia sem Fio/instrumentação , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...