Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-38388684

RESUMO

BACKGROUND AND PURPOSE: The best management of patients with persistent distal occlusion after mechanical thrombectomy with or without IV thrombolysis remains unknown. We sought to evaluate the variability and agreement in decision-making for persistent distal occlusions. MATERIALS AND METHODS: A portfolio of 60 cases was sent to clinicians with varying backgrounds and experience. Responders were asked whether they considered conservative management or rescue therapy (stent retriever, aspiration, or intra-arterial thrombolytics) a treatment option as well as their willingness to enroll patients in a randomized trial. Agreement was assessed using κ statistics. RESULTS: The electronic survey was answered by 31 physicians (8 vascular neurologists and 23 interventional neuroradiologists). Decisions for rescue therapies were more frequent (n = 1116/1860, 60%) than for conservative management (n = 744/1860, 40%; P < .001). Interrater agreement regarding the final management decision was "slight" (κ = 0.12; 95% CI, 0.09-0.14) and did not improve when subgroups of clinicians were studied according to background, experience, and specialty or when cases were grouped according to the level of occlusion. On delayed re-questioning, 23 of 29 respondents (79.3%) disagreed with themselves on at least 20% of cases. Respondents were willing to offer trial participation in 1295 of 1860 (69.6%) cases. CONCLUSIONS: Individuals did not agree regarding the best management of patients with persistent distal occlusion after mechanical thrombectomy and IV thrombolysis. There is sufficient uncertainty to justify a dedicated randomized trial.

2.
AJNR Am J Neuroradiol ; 40(9): 1557-1561, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31467241

RESUMO

BACKGROUND AND PURPOSE: Intraocular silicone oil injection has been used to treat complicated retinal detachments, and recently its retrolaminar and intracranial migration has been reported. The purpose of this study was to document the prevalence of posterior migration of intraocular silicone oil on head CT and describe the clinical and radiologic findings. MATERIALS AND METHODS: This retrospective study included 57 patients with intraocular silicone oil injection who underwent unenhanced head CT between November 2008 and July 2018. All images were visually evaluated for subretinal and retrolaminar migration of intraocular silicone oil involving the anterior visual pathway (optic nerve, optic chiasm, and optic tract) and the ventricular system. Attenuation values of those structures were measured and compared with those of the contralateral or adjacent normal structures. RESULTS: We detected subretinal and retrolaminar silicone oil migration in 7 of the 57 patients (12%), noting silicone oil at the optic nerve head (n = 2), retrolaminar optic nerve (n = 5), optic chiasm (n = 3), optic tract (n = 3), and in the lateral ventricles (n = 1). Attenuation values of the structures with silicone oil migration were significantly higher than those of the control regions (optic nerve head, 69.2 ± 12.4 vs 29.8 ± 10.2 HU, P < .001; retrolaminar optic nerve, 59.9 ± 11.6 vs 30.9 ± 8.6 HU, P < .001; optic chiasm, 74.2 ± 11.0 vs 25.6 ± 6.9 HU, P < .001; optic tract, 70.1 ± 4.7 vs 28.7 ± 7.2 HU, P < .001). No significant ophthalmic or neurologic complications were documented in the patients with silicone oil migration. CONCLUSIONS: Subretinal and retrolaminar migration of intraocular silicone oil is common. Although there were no apparent complications associated with silicone oil migration, the radiologist and clinician should be aware of this phenomenon.


Assuntos
Descolamento Retiniano/terapia , Óleos de Silicone/efeitos adversos , Adulto , Feminino , Humanos , Injeções Intraoculares , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Óleos de Silicone/administração & dosagem , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...