Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 21
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Luminescence ; 39(7): e4819, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38956814

RESUMO

Mefenamic acid, renowned for its analgesic properties, stands as a reliable choice for alleviating mild to moderate pain. However, its versatility extends beyond pain relief, with ongoing research unveiling its promising therapeutic potential across diverse domains. A straightforward, environmentally friendly, and sensitive spectrofluorometric technique has been developed for the precise quantification of the analgesic medication, mefenamic acid. This method relies on the immediate reduction of fluorescence emitted by a probe upon interaction with varying concentrations of the drug. The fluorescent probe utilized, N-phenyl-1-naphthylamine (NPNA), was synthesized in a single step, and the fluorescence intensities were measured at 480 nm using synchronous fluorescence spectroscopy with a wavelength difference of 200 nm. Temperature variations and lifetime studies indicated that the quenching process was static. The calibration curve exhibited linearity within the concentration range of 0.50-9.00 µg/mL, with a detection limit of 60.00 ng/mL. Various experimental parameters affecting the quenching process were meticulously examined and optimized. The proposed technique was successfully applied to determine mefenamic acid in pharmaceutical formulations, plasma, and urine, yielding excellent recoveries ranging from 98% to 100.5%. The greenness of the developed method was evaluated using three metrics: the Analytical Eco-scale, AGREE, and the Green Analytical Procedure Index.


Assuntos
Corantes Fluorescentes , Ácido Mefenâmico , Espectrometria de Fluorescência , Ácido Mefenâmico/análise , Ácido Mefenâmico/química , Ácido Mefenâmico/urina , Corantes Fluorescentes/química , Corantes Fluorescentes/síntese química , Humanos , Estrutura Molecular , Preparações Farmacêuticas/química , Preparações Farmacêuticas/análise , Limite de Detecção
2.
J Proteome Res ; 23(7): 2386-2396, 2024 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-38900499

RESUMO

Tyrosine sulfation, an understudied but crucial post-translational modification, cannot be directly detected in conventional nanoflow liquid chromatography-tandem mass spectrometry (nanoLC-MS/MS) due to the extreme sulfate lability. Here, we report the detection of sulfate-retaining fragments from LC-electron capture dissociation (ECD) and nanoLC-electron transfer higher energy collision dissociation (EThcD). Sulfopeptide candidates were identified by Proteome Discoverer and MSFragger analysis of nanoLC-HCD MS/MS data and added to inclusion lists for LC-ECD or nanoLC-EThcD MS/MS. When this approach failed, targeted LC-ECD with fixed m/z isolation windows was performed. For the plasma protein fibrinogen, the known pyroglutamylated sulfopeptide QFPTDYDEGQDDRPK from the beta chain N-terminus was identified despite a complete lack of sulfate-containing fragment ions. The peptide QVGVEHHVEIEYD from the gamma-B chain C-terminus was also identified as sulfated or phosphorylated. This sulfopeptide is not annotated in Uniprot but was previously reported. MSFragger further identified a cysteine-containing peptide from the middle of the gamma chain as sulfated and deamidated. NanoLC-EThcD and LC-ECD MS/MS confirmed the two former sulfopeptides via sulfate-retaining fragment ions, whereas an unexpected fragmentation pattern was observed for the third sulfopeptide candidate. Manual interpretation of the LC-ECD spectrum revealed two additional isobaric identifications: a trisulfide-linked cysteinyl-glycine or a carbamidomethyl-dithiothreiotol covalent adduct. Synthesis of such adducts confirmed the latter identity.


Assuntos
Fibrinogênio , Espectrometria de Massas em Tandem , Tirosina , Tirosina/química , Tirosina/análogos & derivados , Espectrometria de Massas em Tandem/métodos , Fibrinogênio/química , Fibrinogênio/metabolismo , Cromatografia Líquida/métodos , Humanos , Processamento de Proteína Pós-Traducional , Tripsina/química , Tripsina/metabolismo , Sulfatos/química , Sequência de Aminoácidos , Peptídeos/química , Peptídeos/análise , Elétrons
3.
BMC Chem ; 17(1): 170, 2023 Nov 28.
Artigo em Inglês | MEDLINE | ID: mdl-38017490

RESUMO

Environmental appearance of antimicrobials due to frequent use of personal care products as recommended by WHO can cause serious flare-up of antimicrobial resistance. In this work, three eco-friendly microfabricated copper solid-state sensors were developed for measuring triclosan in water. Multi-walled carbon nanotubes were incorporated in sensor 2 and 3 as hydrophobic conductive inner layer. Meanwhile, ß-cyclodextrin was incorporated in sensor 3 as an ionophore for selective binding of TCS in presence of interfering compounds. The obtained linear responses of sensors 1, 2 and 3 were (1 × 10- 8-1 × 10- 3 M), (1 × 10- 9-1 × 10- 3 M) and (1 × 10- 10- 1 × 10- 3 M), respectively. Limit of detection was 9.87 × 10- 9 M, 9.62 × 10- 10 M, and 9.94 × 10- 11 M, respectively. The miniaturized sensors were utilized for monitoring of triclosan in water samples.

4.
Sci Rep ; 13(1): 20187, 2023 11 18.
Artigo em Inglês | MEDLINE | ID: mdl-37980444

RESUMO

Analysis of drugs clinically and their identification in biological samples are of utmost importance in the process of therapeutic drug monitoring, also in pharmacokinetic investigations and tracking of illicit medications. These investigations are carried out using a variety of analytical methods, including potentiometric electrodes. Potentiometric electrodes are a wonderful solution for researchers because they outperform other methods in terms of sustainability, greenness, and cost effectiveness. In the current study, ion-selective potentiometric sensors were assembled for the aim of quantification of the anticancer drug Letrozole (LTZ). The first step was fabrication of a conventional sensor based on the formation of stable host-guest inclusion complex between the cationic drug and 4-tert-butylcalix-8-arene (TBCAX-8). Two additional sensors were prepared through membrane modification with graphene nanocomposite (GNC) and polyaniline (PANI) nanoparticles. Linear responses of 1.00 × 10-5-1.00 × 10-2, 1.00 × 10-6-1.00 × 10-2 and 1.00 × 10-8-1.00 × 10-3 with sub-Nernstian slopes of 19.90, 20.10 and 20.30 mV/decade were obtained for TBCAX-8, GNC, and PANI sensors; respectively. The developed sensors were successful in determining the drug LTZ in bulk powder and dosage form. PANI modified sensor was used to determine LTZ in human plasma with recoveries ranging from 88.00 to 96.30%. IUPAC recommendations were followed during the evaluation of the electrical performance of the developed sensors. Experimental conditions as temperature and pH were studied and optimized. Analytical Eco-scale and Analytical GREEness metric were adopted as the method greenness assessment tools.


Assuntos
Grafite , Eletrodos Seletivos de Íons , Humanos , Letrozol , Eletrodos , Potenciometria/métodos
5.
Anal Bioanal Chem ; 415(22): 5451-5462, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37389600

RESUMO

One of the most important reasons for an increased mortality rate of cancer is late diagnosis. Point-of-care (POC) diagnostic sensors can provide rapid and cost-effective diagnosis and monitoring of cancer biomarkers. Portable, disposable, and sensitive sarcosine solid-contact ion-selective potentiometric sensors (SC-ISEs) were fabricated as POC analyzers for the rapid determination of the prostate cancer biomarker sarcosine. Tungsten trioxide nanoparticles (WO3 NPs), polyaniline nanoparticles (PANI NPs), and PANI-WO3 nanocomposite were used as ion-to-electron transducers on screen-printed sensors. WO3 NPs and PANI-WO3 nanocomposite have not been investigated before as ion-to-electron transducer layers in potentiometric SC sensors. The designated sensors were characterized using SEM, XRD, FTIR, UV-VIS spectroscopy, and EIS. The inclusion of WO3 and PANI in SC sensors enhanced the transduction at the interface between the screen-printed SC and the ion-selective membrane, offering lower potential drift, a longer lifetime, shorter response time, and better sensitivity. The proposed sarcosine sensors exhibited Nernstian slopes over linear response ranges 10-3-10-7 M, 10-3-10-8 M, 10-5-10-9 M, and 10-7-10-12 M for control, WO3 NPs, PANI NPs, and PANI-WO3 nanocomposite-based sensors, respectively. From a comparative point of view between the four sensors, PANI-WO3 nanocomposite inclusion offered the lowest potential drift (0.5 mV h-1), the longest lifetime (4 months), and the best LOD (9.95 × 10-13 M). The proposed sensors were successfully applied to determine sarcosine as a potential prostate cancer biomarker in urine without prior sample treatment steps. The WHO ASSURED criteria for point-of-care diagnostics are met by the proposed sensors.


Assuntos
Nanocompostos , Neoplasias da Próstata , Masculino , Humanos , Biomarcadores Tumorais , Sarcosina , Próstata , Polímeros/química , Óxidos/química , Neoplasias da Próstata/diagnóstico , Testes Imediatos , Nanocompostos/química
6.
J AOAC Int ; 104(1): 103-112, 2021 Mar 05.
Artigo em Inglês | MEDLINE | ID: mdl-33751067

RESUMO

BACKGROUND: Nowadays, emergence of unexpected contaminants in drinking water is a challenging environmental problem facing humanity. OBJECTIVE: Two eco-friendly spectrofluorimetric methods were proposed for the determination of three unexpected contaminants in drinking tap water. METHODS: The first method is first derivative synchronous spectrofluorimetric method which was developed for simultaneous determination of atenolol (ATN) and diclofenac (DCF) without prior separation at Δλ = 70 nm and at Δλ = 80 nm for ATN and DCF, respectively. The second method was based on using sodium dodecyl sulfate (SDS) as fluorescent enhancer of triclosan (TCS) native fluorescence. TCS exhibits enhanced fluorescence at λ emission = 600 nm upon excitation at λ excitation = 299.4 nm. Solid phase extraction was carried out in both methods. RESULTS: Linear calibration curves were obtained in concentration range of (4-3000 ng/mL) for ATN and (4-2000 ng/mL) for DCF, by measuring first derivative signal of fluorescence at 300 nm and 375.2 nm, respectively. TCS exhibits linear range (0.1-1 ng/mL) at 600 nm. Mean percentage recoveries were 101.04 ± 0.571, 99.66 ± 1.443, and 99.73 ± 0.566 for ATN, DCF, and TCS, respectively. CONCLUSIONS: Validation of both methods were performed according to the International Conference on Harmonization guidelines. Results obtained were statistically compared with published methods and no significant differences were found. The proposed methods' greenness is evaluated using analytical Eco-scale and Green Analytical Procedure Index. A greenness comparison with previously published methods has been performed. HIGHLIGHTS: Both methods were found to be eco-friendly and were successfully applied for the determination of the emerging contaminants in drinking tap water.


Assuntos
Água Potável , Triclosan , Atenolol , Diclofenaco , Micelas , Espectrometria de Fluorescência
7.
Environ Sci Process Impacts ; 23(3): 457-466, 2021 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-33555283

RESUMO

The environmental emergence of unexpected contaminants has gained the attention of the scientific community. A broad spectrum antimicrobial compound named triclosan (TCS) was detected in the environment as an emerging contaminant. Owing to its inherent toxicity, we have proposed eco-friendly potentiometric liquid state sensors to be used for monitoring and quantifying TCS in environmental water samples. The proposed sensors have been optimized by modifying the inner filling solution using hydrophilic 2-hydroxypropyl ß-cyclodextrin as a complexing agent to be capable of minimizing the trans-membrane ion flux and hence improving the selective and sensitive determination of TCS in environmental matrices with low LOD values. The obtained linear response of the optimized sensor was (1 × 10-9 to 1 × 10-5 M) compared to the control sensor (1 × 10-8 to 1 × 10-4 M). The obtained limit of detection (LOD) value was found to be 9.86 × 10-10 M compared to 9.78 × 10-9 M of the control sensor. The modification of the inner filling solution of the sensor with 2-hydroxypropyl ß-cyclodextrin improves not only its sensitivity but also its response time to be only 5 seconds. The electrical performance of the proposed sensor was evaluated following IUPAC recommendations. Both the pH and temperature effects were studied and optimized. Two different greenness assessment tools, Analytical Eco-scale and Green Procedure Index, were adopted upon the evaluation of the proposed sensors' greenness.


Assuntos
Ciclodextrinas , Triclosan , 2-Hidroxipropil-beta-Ciclodextrina , Limite de Detecção , Água
8.
Luminescence ; 33(5): 919-932, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-29737023

RESUMO

Stability-indicating high-performance liquid chromatography (HPLC) and spectrofluorimetric methods were developed for determination of empagliflozin (EGF). EGF was subjected to oxidation, wet heat, photo-degradation, acid hydrolysis and alkali hydrolysis. The alkaline degradation pathway was subjected to a kinetics study as the major product obtained after stress conditions. Arrhenius plots were constructed and the activation energies of the degradation process were calculated. HPLC was used for the kinetic study as it enabled simultaneous determination of EGF and the degradation product while the spectrofluorimetric assay was applied to content uniformity testing due to its higher sensitivity and lower limit of detection (LOD). Isocratic chromatographic elution was attained for HPLC on a Intersil® C18 column (150 mm × 4 mm, 5 µm), using a mobile phase of acetonitrile-potassium dihydrogen phosphate buffer pH 4, (50:50, v/v) at a flow rate of 1 ml/min with ultraviolet (UV) detection at 225 nm. The relative fluorescence intensity was recorded by spectrofluorimeter applying synchronous mode using ∆λ = 70 nm at 297.6 nm. Linearity ranges were found to be 5-50 µg/ml and 50-1000 ng/ml for HPLC and spectrofluorimetric methods, respectively.


Assuntos
Compostos Benzidrílicos/análise , Cromatografia Líquida de Alta Pressão/métodos , Glucosídeos/análise , Espectrometria de Fluorescência/métodos , Compostos Benzidrílicos/química , Compostos Benzidrílicos/farmacocinética , Soluções Tampão , Estabilidade de Medicamentos , Glucosídeos/química , Glucosídeos/farmacocinética , Concentração de Íons de Hidrogênio , Hidrólise , Cinética , Limite de Detecção , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Inibidores do Transportador 2 de Sódio-Glicose/análise , Inibidores do Transportador 2 de Sódio-Glicose/química , Inibidores do Transportador 2 de Sódio-Glicose/farmacocinética , Tensoativos/química , Comprimidos/análise , Temperatura , Fatores de Tempo
9.
J Fluoresc ; 28(2): 491-504, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29344769

RESUMO

Synchronous spectrofluorimetric methods could be successfully adopted for simultaneous determination of Octinoxate (OMC), Avobenzone (AVO), Octyltriazone (OT), and Phenyl benzimidazole sulfonic acid (PBSA) in moisturizing sunscreen lotion, utilizing ß-CD as fluorescence enhancer, and determination of Avobenzone (AVO), Homosalate, Tinosorb M and Phenyl benzimidazole sulfonic acid (PBSA) in presence of Octocrylene (OCR) in whitening sunscreen cream, using micellar medium of Sodium Dodecyl Sulfate (SDS) to enhance fluorescence intensity. For first product, zero order synchronous spectrofluorimetric method was used for determination of OMC and AVO, and derivative synchronous spectrofluorimetric technique was utilized for OT and PBSA in quaternary mixture. Linear calibration curves were obtained in a concentration range of 0.5-8 µg mL- 1 for OMC and AVO, and in range of 0.05-3 µg mL- 1 for OT and 0.001-5 µg mL- 1 for PBSA, by measuring the fluorescence at 370, 405, 333.2 and 340.6 nm, respectively. For second product, first derivative synchronous fluorescence method was used for each UV-filter. A linear calibration curves were obtained in a concentration range of 0.5-8 µg mL- 1 for AVO, in range of 0.1-8 µg mL- 1 for Homosalate, 2-10 µg mL- 1 for Tinosorb M and 0.001-5 µg mL- 1 for PBSA, by measuring the fluorescence at 409.8, 373, 307.2 and 316.8 nm, respectively. The detection limits are well below the maximum admissible concentration. The proposed methods were validated according to ICH guidelines and successfully applied to determine sunscreens in pure form and in Cosmeceutical formulations. All the results obtained were compared with those of published methods, where no significant difference was observed.


Assuntos
Corantes Fluorescentes/química , Protetores Solares/química , Composição de Medicamentos , Micelas , Espectrometria de Fluorescência , Tensoativos/química
10.
Artigo em Inglês | MEDLINE | ID: mdl-28528664

RESUMO

A new fast LC-MS/MS method was developed for determination of alogliptin and pioglitazone in human plasma. Linearity ranges of 10-400ngmL-1 for alogliptin and 25-2000ngmL-1 for pioglitazone, were found to be suitable for their bioanalysis covering the Cmin and Cmax values of the drugs. Direct precipitation technique was used for simultaneous extraction of the drugs successfully from human plasma samples. Chromatographic separation was achieved on a BEH C18 column (50mm×2.1mm, 1.7µm) with 0.1% aqueous formic acid: acetonitrile (40:60, v/v) at a flow rate of 0.3mLmin-1. The validated method was applied to a preliminary pharmacokinetic study on human volunteers. Monitoring the transition pairs of m/z 340.18 to 116.08 for alogliptin and m/z 356.99 to 133.92 for pioglitazone, using triple quadrupole mass spectrometer with multiple reaction monitoring, was achieved in the positive mode. The validated method is accurate and suitable for further clinical applications and possible bioequivalence studies.


Assuntos
Cromatografia Líquida/métodos , Piperidinas/sangue , Piperidinas/farmacocinética , Espectrometria de Massas em Tandem/métodos , Tiazolidinedionas/sangue , Tiazolidinedionas/farmacocinética , Uracila/análogos & derivados , Adulto , Estabilidade de Medicamentos , Humanos , Modelos Lineares , Pioglitazona , Piperidinas/química , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Tiazolidinedionas/química , Uracila/sangue , Uracila/química , Uracila/farmacocinética
11.
J AOAC Int ; 100(5): 1379-1391, 2017 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-28421983

RESUMO

New multivariate and univariate methods were developed for the analysis of two novel gliptin combinations by manipulating the zero-order and ratio spectra of empagliflozin and linagliptin in combination, with application on Glyxambi® tablets, and of alogliptin and pioglitazone in combination, with application on Oseni® tablets. Linearity ranges for chemometric approaches using principal component regression and partial least-squares were found to be 2-10, 2.5-12.5, 5-15, and 5-25 µg/mL for empagliflozin, linagliptin, alogliptin, and pioglitazone, respectively, whereas the respective linearity ranges for the spectrophotometric approaches were found to be 5-15, 2-12, 5-15, and 5-15 µg/mL. The proposed spectrophotometric methods included ratio subtraction coupled with extended ratio subtraction, spectrum subtraction coupled with constant multiplication, and mean centering. Acceptable LOD and LOQ values were obtained by all methods. Statistical analysis showed no significant difference between multivariate and univariate methods in comparison with the reference methods. The optimized methods provide fast and economic determination of the recently approved antidiabetic combinations without the complex instrumentation or time-consuming mobile phase preparations that were used in the chromatographic techniques reported in the literature.


Assuntos
Combinação de Medicamentos , Hipoglicemiantes/análise , Análise dos Mínimos Quadrados , Análise Multivariada , Espectrofotometria , Comprimidos
12.
Talanta ; 164: 518-528, 2017 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-28107966

RESUMO

Five new potentiometric membrane sensors for the determination of the dinotefuran levels in cucumber and soil samples have been developed. Four of these sensors were based on a newly designed molecularly imprinted polymer (MIP) material consisting of acrylamide or methacrylic acid as a functional monomer in a plasticized PVC (polyvinyl chloride) membrane before and after elution of the template. A fifth sensor, a carboxylated PVC-based sensor plasticized with dioctyl phthalate, was also prepared and tested. Sensor 1 (acrylamide washed) and sensor 3 (methacrylic acid washed) exhibited significantly enhanced responses towards dinotefuran over the concentration range of 10-7-10-2molL-1. The limit of detection (LOD) for both sensors was 0.35µgL-1. The response was near-Nernstian, with average slopes of 66.3 and 50.8mV/decade for sensors 1 and 3 respectively. Sensors 2 (acrylamide non-washed), 4 (methacrylic acid non-washed) and 5 (carboxylated-PVC) exhibited non-Nernstian responses over the concentration range of 10-7-10-3molL-1, with LODs of 10.07, 6.90, and 4.30µgL-1, respectively, as well as average slopes of 39.1, 27.2 and 33mV/decade, respectively. The application of the proposed sensors to the determination of the dinotefuran levels in spiked soil and cucumber samples was demonstrated. The average recoveries from the cucumber samples were from 7.93% to 106.43%, with a standard deviation of less than 13.73%, and recoveries from soil samples were from 97.46% to 108.71%, with a standard deviation of less than 10.66%. The sensors were applied successfully to the determination of the dinotefuran residue, its rate of disappearance and its half-life in cucumbers in soil in which a safety pre-harvest interval for dinotefuran was suggested.


Assuntos
Cucumis sativus/química , Guanidinas/análise , Inseticidas/análise , Neonicotinoides/análise , Nitrocompostos/análise , Resíduos de Praguicidas/análise , Folhas de Planta/química , Potenciometria/instrumentação , Solo/química , Análise de Alimentos , Contaminação de Alimentos/análise , Concentração de Íons de Hidrogênio , Fatores de Tempo
13.
Spectrochim Acta A Mol Biomol Spectrosc ; 171: 236-245, 2017 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-27541796

RESUMO

New, simple, accurate and sensitive UV spectrophotometric and chemometric methods have been developed and validated for determination of Entacapone (ENT), Levodopa (LD) and Carbidopa (CD) in ternary mixture. Method A is a derivative ratio spectra zero-crossing spectrophotometric method which allows the determination of ENT in the presence of both LD and CD by measuring the peak amplitude at 249.9nm in the range of 1-20µgmL-1. Method B is a double divisor-first derivative of ratio spectra method, used for determination of ENT, LD and CD at 245, 239 and 293nm, respectively. Method C is a mean centering of ratio spectra which allows their determination at 241, 241.6 and 257.1nm, respectively. Methods B and C could successfully determine the studied drugs in concentration ranges of 1-20µgmL-1 for ENT and 10-90µgmL-1 for both LD and CD. Methods D and E are principal component regression and partial least-squares, respectively, used for the simultaneous determination of the studied drugs by using seventeen mixtures as calibration set and eight mixtures as validation set. The developed methods have the advantage of simultaneous determination of the cited components without any pre-treatment. All the results were statistically compared with the reported methods, where no significant difference was observed. The developed methods were satisfactorily applied to the analysis of the investigated drugs in their pure form and in pharmaceutical dosage forms.


Assuntos
Carbidopa/análise , Catecóis/análise , Levodopa/análise , Nitrilas/análise , Espectrofotometria/métodos , Calibragem , Carbidopa/química , Catecóis/química , Análise dos Mínimos Quadrados , Levodopa/química , Limite de Detecção , Nitrilas/química , Análise de Componente Principal , Reprodutibilidade dos Testes
14.
J AOAC Int ; 100(1): 176-188, 2017 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-27765084

RESUMO

A sensitive, selective, and validated HPLC-diode-array detection method was developed for the simultaneous determination of five neonicotinoid insecticides-acetamiprid, imidacloprid, nitenpyram, flonicamid, and thiacloprid-and their primary metabolite, 6-chloronicotinic acid, in cucumbers and soil based on the quick, easy, cheap, effective, rugged, and safe (QuEChERS) technique as a pretreatment procedure. In the QuEChERS procedure, cucumber samples were extracted with acetonitrile and cleaned using C18, whereas soil samples were extracted with an acetonitrile-dichloromethane mixture (1 + 2). The HPLC conditions were optimized by separating neonicotinoids using an acetonitrile-water mixture (25 + 75) and a Synergi Hydro RP C18 column. Matrix-matched calibration standards were prepared in cucumber and soil to eliminate any matrix interference. RSDs were ≤9% in all recovery tests. LODs and LOQs for the five neonicotinoids were in the ranges of 0.006-0.122 and 0.018-0.366 µg/g, respectively. This method was successfully applied to determine residues, the rate of disappearance of the five neonicotinoids from cucumber and soil, and the half-lives of the neonicotinoids.


Assuntos
Cromatografia Líquida de Alta Pressão , Cucumis sativus/química , Neonicotinoides/análise , Resíduos de Praguicidas/análise , Poluentes do Solo/análise , Solo/química , Inseticidas/análise , Espectrometria de Massas em Tandem
15.
Artigo em Inglês | MEDLINE | ID: mdl-27447929

RESUMO

A new, rapid, sensitive, precise and validated high performance liquid chromatography coupled to tandem mass spectrometry (HPLC-MS/MS) method was developed for the simultaneous determination of eight neonicotinoid insecticides with their two primary metabolites in cucumbers and soil based on QuEChERS as a pretreatment procedure. In QuEChERS procedure, cucumber samples were extracted with acetonitrile and cleaned using (C18 sorbent material), while soil samples were extracted with a mixture of acetonitrile:dichloromethane (8.3:16.7v:v). The LC-MS/MS conditions were optimized to provide good selectivity and specificity of the developed method where neonicotinoids were separated using gradient elution of water and acetonitrile both containing 0.1% formic acid with Gemini C18 column where the last compound was eluted at 9.5min. Average recoveries of the eight neonicotinoids and their metabolites ranged between 81.6% and 95.7% in fortified cucumber samples with relative standard deviations (RSDs) lower than 13.18% and between 80.3% and 104% in fortified soil samples with relative standard deviations (RSDs) lower than 8.44%. The limits of detection (LODs) and quantification (LOQs) for the ten compounds were in the ranges of (0.08-6.06ng/g) and (0.26-20ng/g), respectively. The method was applied successfully to determine residues and rate of disappearance of the eight neonicotinoids from cucumber and soil and their half-lives where a safety pre-harvest interval of 5days for acetampirid, 12days for imidacloprid, 15days for nitenpyram, 12days for thiamethoxam, 5days for flonicamid, 8days for clothianidin, 2days for Dinotefuran, and 1day for thiacloprid were suggested.


Assuntos
Anabasina/análise , Cromatografia Líquida de Alta Pressão/métodos , Cucumis sativus/metabolismo , Inseticidas/análise , Espectrometria de Massas em Tandem/métodos , Anabasina/metabolismo , Inseticidas/metabolismo , Limite de Detecção , Reprodutibilidade dos Testes
16.
Spectrochim Acta A Mol Biomol Spectrosc ; 157: 251-257, 2016 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-26779820

RESUMO

Three spectrophotometric methods have been developed and validated for determination of indacaterol (IND) and glycopyrronium (GLY) in their binary mixtures and novel pharmaceutical dosage form. The proposed methods are considered to be the first methods to determine the investigated drugs simultaneously. The developed methods are based on different signal processing techniques of ratio spectra namely; Numerical Differentiation (ND), Savitsky-Golay (SG) and Fourier Transform (FT). The developed methods showed linearity over concentration range 1-30 and 10-35 (µg/mL) for IND and GLY, respectively. The accuracy calculated as percentage recoveries were in the range of 99.00%-100.49% with low value of RSD% (<1.5%) demonstrating an excellent accuracy of the proposed methods. The developed methods were proved to be specific, sensitive and precise for quality control of the investigated drugs in their pharmaceutical dosage form without the need for any separation process.


Assuntos
Agonistas de Receptores Adrenérgicos beta 2/análise , Glicopirrolato/análise , Indanos/análise , Antagonistas Muscarínicos/análise , Quinolonas/análise , Cápsulas , Análise de Fourier , Limite de Detecção , Espectrofotometria/métodos
17.
J AOAC Int ; 98(5): 1215-25, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26525239

RESUMO

Accurate, reliable, and sensitive spectrophotometric and chemometric methods were developed for simultaneous determination of octinoxate (OMC), oxybenzone (OXY), and octocrylene (OCR) in a sunscreen formulation without prior separation steps, including derivative ratio spectra zero crossing (DRSZ), double divisor ratio spectra derivative (DDRD), mean centering ratio spectra (MCR), and partial least squares (PLS-2). With the DRSZ technique, the UV filters could be determined in the ranges of 0.5-13.0, 0.3-9.0, and 0.5-9.0 µg/mL at 265.2, 246.6, and 261.8 nm, respectively. By utilizing the DDRD technique, UV filters could be determined in the above ranges at 237.8, 241.0, and 254.2 nm, respectively. With the MCR technique, the UV filters could be determined in the above ranges at 381.7, 383.2, and 355.6 nm, respectively. The PLS-2 technique successfully quantified the examined UV filters in the ranges of 0.5-9.3, 0.3-7.1, and 0.5-6.9 µg/mL, respectively. All the methods were validated according to the International Conference on Harmonization guidelines and successfully applied to determine the UV filters in pure form, laboratory-prepared mixtures, and a sunscreen formulation. The obtained results were statistically compared with reference and reported methods of analysis for OXY, OMC, and OCR, and there were no significant differences with respect to accuracy and precision of the adopted techniques.


Assuntos
Acrilatos/análise , Benzofenonas/análise , Cinamatos/análise , Protetores Solares/análise , Calibragem , Guias como Assunto , Humanos , Sensibilidade e Especificidade , Espectrofotometria Ultravioleta/métodos , Raios Ultravioleta , Estudos de Validação como Assunto
18.
Artigo em Inglês | MEDLINE | ID: mdl-25942082

RESUMO

Four simple, specific, accurate and precise spectrophotometric methods were developed and validated for simultaneous determination of Domperidone (DP) and Ranitidine Hydrochloride (RT) in bulk powder and pharmaceutical formulation. The first method was simultaneous ratio subtraction (SRS), the second was ratio subtraction (RS) coupled with zero order spectrophotometry (D(0)), the third was first derivative of the ratio spectra ((1)DD) and the fourth method was mean centering of ratio spectra (MCR). The calibration curve is linear over the concentration range of 0.5-5 and 1-45 µg mL(-1) for DP and RT, respectively. The proposed spectrophotometric methods can analyze both drugs without any prior separation steps. The selectivity of the adopted methods was tested by analyzing synthetic mixtures of the investigated drugs, also in their pharmaceutical formulation. The suggested methods were validated according to International Conference of Harmonization (ICH) guidelines and the results revealed that; they were precise and reproducible. All the obtained results were statistically compared with those of the reported method, where there was no significant difference.


Assuntos
Domperidona/análise , Ranitidina/análise , Espectrofotometria/métodos , Análise de Variância , Química Farmacêutica , Domperidona/química , Limite de Detecção , Pós , Ranitidina/química , Padrões de Referência , Análise de Regressão
19.
Spectrochim Acta A Mol Biomol Spectrosc ; 139: 449-55, 2015 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-25576942

RESUMO

The present work is concerned with simultaneous determination of cefepime (CEF) and the co-administered drug, levofloxacin (LEV), in spiked human plasma by applying a new approach, Savitzky-Golay differentiation filters, and combined trigonometric Fourier functions to their ratio spectra. The different parameters associated with the calculation of Savitzky-Golay and Fourier coefficients were optimized. The proposed methods were validated and applied for determination of the two drugs in laboratory prepared mixtures and spiked human plasma. The results were statistically compared with reported HPLC methods and were found accurate and precise.


Assuntos
Cefalosporinas/sangue , Análise de Fourier , Levofloxacino/sangue , Modelos Moleculares , Cefepima , Humanos , Soluções , Espectrofotometria Ultravioleta
20.
J Chromatogr Sci ; 53(4): 554-64, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25060753

RESUMO

A new, simple, selective, reproducible and sensitive stability-indicating liquid chromatographic method was developed and subsequently validated for the determination of saxagliptin (SXG). SXG was subjected to oxidation, thermal, acid hydrolysis, alkali hydrolysis and photodegradation according to ICH guidelines. The major degradation products were separated from the pure drug and the proposed structures' elucidation was performed, using an LC-MS technique. Isocratic chromatographic elution was achieved on a Symmetry(®) C18 column (150 × 4.6 mm, 5 µm), using a mobile phase of potassium dihydrogen phosphate buffer (pH 4.6)-acetonitrile-methanol (40 : 30 : 30, v/v/v) at a flow rate of 1 mL min(-1) with UV detection at 208 nm. Linearity, accuracy and precision were found to be acceptable over the concentration range of 25-400 µg mL(-1). All the results were statistically compared with the reference method, using one-way analysis of variance. The developed method was validated and proved to be specific and accurate for quality control of SXG in pharmaceutical dosage form.


Assuntos
Adamantano/análogos & derivados , Cromatografia Líquida de Alta Pressão/métodos , Dipeptídeos/análise , Dipeptídeos/química , Espectrometria de Massas/métodos , Adamantano/análise , Adamantano/química , Análise de Variância , Estabilidade de Medicamentos , Limite de Detecção , Modelos Lineares , Modelos Moleculares , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...