Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
2.
J Cardiovasc Electrophysiol ; 33(2): 154-159, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34953099

RESUMO

BACKGROUND: Cardiac perforation during leadless pacemaker implantation is more likely to require intervention than perforation by a transvenous lead. This study reports the consequences of Micra pacemaker perforations and related device and operator use problems based on information the manufacturer has submitted to the Food and Drug Administration (FDA). METHODS: FDA's Manufacturer and User Facility Device Experience (MAUDE) database was searched for Micra perforations. Data extracted included deaths, major adverse clinical events (MACEs), and device and/or operator use problems. RESULTS: Between 2016 and July 2021, 563 perforations were reported within 30 days of implant and resulted in 150 deaths (27%), 499 cardiac tamponades (89%), 64 pericardial effusions (11%), and 146 patients (26%) required emergency surgery. Half of perforations were associated with 139 (25%) device problems, 78 (14%) operator use problems, and 62 (11%) combined device and operator use problems. Inadequate electrical measurements or difficult positioning were the most frequent device problems (n = 129); non-septal implants and perforation of other structures were the most frequent operator use problems (n = 69); a combined operator use and device problem resulted in 62 delivery system perforations. No device or operator use problem was identified for 282 perforations (50%), but they were associated with 78 deaths, 245 tamponades, and 57 emergency surgeries. CONCLUSION: The Micra perforations reported in MAUDE are often associated with death and major complications requiring emergency intervention. Device and use problems account for at least half of perforations. Studies are needed to identify who is at risk for a perforation and how MACE can be avoided or mitigated.


Assuntos
Tamponamento Cardíaco , Traumatismos Cardíacos , Marca-Passo Artificial , Tamponamento Cardíaco/etiologia , Traumatismos Cardíacos/diagnóstico por imagem , Traumatismos Cardíacos/etiologia , Traumatismos Cardíacos/terapia , Humanos , Marca-Passo Artificial/efeitos adversos , Resultado do Tratamento , Estados Unidos , United States Food and Drug Administration
3.
Heart Rhythm ; 18(7): 1132-1139, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33713856

RESUMO

BACKGROUND: Leadless intracardiac pacemakers were developed to avoid the complications of transvenous pacing systems. The Medtronic Micra™ transcatheter pacemaker is one such system. We found an unexpected number of major adverse clinical events (MACE) in the Food and Drug Administration's Manufacturers and User Facility Device Experience (MAUDE) database associated with Micra implantation. OBJECTIVE: The purpose of this study was to describe these MACE and compare them to implant procedure MACE in MAUDE for Medtronic CapSureFix™ active-fixation transvenous pacing leads. METHODS: During January 2021, we queried the MAUDE database for reports of MACE for Micra pacemakers and CapSureFix leads using the simple search terms "death," "tamponade," and "perforation." Reports from 2016-2020 were included. RESULTS: The search identified 363 MACE for Micra and 960 MACE for CapSureFix leads, including 96 Micra deaths (26.4%) vs 23 CapSureFix deaths (2.4%) (P <.001); 287 Micra tamponades (79.1%) vs 225 tamponades for CapSureFix (23.4%) (P <.001); and 99 rescue thoracotomies for Micra (27.3%) vs 50 rescue thoracotomies for CapSureFix (5.2%) (P <.001). More Micra patients required cardiopulmonary resuscitation (21.8% vs 1.1%) and suffered hypotension or shock (22.0% vs 5.8%) than CapSureFix recipients (P <.001). Micra patients were more likely to survive a myocardial perforation or tear if they had surgical repair (P = .014). CONCLUSION: Micra leadless pacemaker implantation may be complicated by myocardial and vascular perforations and tears that result in cardiac tamponade and death. We estimate the incidence is low (<1%). Rescue surgery to repair perforations may be lifesaving. MACE are significantly less for implantation of CapSureFix transvenous ventricular pacing leads.


Assuntos
Arritmias Cardíacas/terapia , Tamponamento Cardíaco/etiologia , Marca-Passo Artificial/efeitos adversos , Desenho de Equipamento , Seguimentos , Humanos , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo
4.
J Interv Card Electrophysiol ; 62(3): 507-518, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33387130

RESUMO

PURPOSE: We hypothesized that data in manufacturers' product performance reports (PPRs) can provide clinically valuable ICD and cardiac resynchronization defibrillator (CRT-D) reliability and longevity information. METHODS: Data were obtained from 2019 PPRs. Kaplan-Meier (K-M) probabilities of freedom from malfunction, normal battery depletion (NBD), and NBD + malfunction were calculated for ICD and CRT-D pulse generators (PGs) with LiMnO2 or LiSVO/CFx batteries marketed in the USA from 2010 to 2019 and compared using the log-rank test. Malfunctions (MAL) included PGs that were found outside specifications. RESULTS: Study population included 1,149,803 ICD and CRT-D PGs: Abbott (ABT; 35.1%), Biotronik (BIO; 4.6%), Boston Scientific (BSC; 23.5%), and Medtronic (MDT; 36.9%). Significant differences in reliability (p < 0.001), defined by freedom from MAL, were found between manufacturers; the majority of 6808 MAL occurred in ABT devices (n = 4045; 59.4%), followed by BSC (n = 2384; 35.0%), MDT (n = 338;5.0%), and BIO (n = 41; 0.6%). Battery failure (n = 890; 57.9%) was the most common cause of MAL compromising therapy; analysis of unique ABT battery MAL-indicated problem appeared a year prior to advisory. Significant differences (p < 0.001) in battery longevity, as defined by freedom from NBD, were found between manufacturers. Overall performance (freedom from NBD + MAL) favored BSC for CRT-D PGs and MDT and BIO for ICDs. BSC subcutaneous ICD reliability was inferior to its transvenous ICD (p < 0.001). CONCLUSION: PPRs contain valuable data that can be aggregated and analyzed to inform physicians. Differences in product reliability exist between manufacturers. Battery longevity has improved, but MAL have significantly impacted performance. PPR data may be useful for assessing product problems and new technology.


Assuntos
Desfibriladores Implantáveis , Remoção de Dispositivo , Falha de Equipamento , Humanos , Reprodutibilidade dos Testes , Fatores de Tempo
5.
Am Heart J ; 218: 128-132, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31806088

RESUMO

New-onset left bundle branch block (N-LBBB) after transcatheter aortic valve replacement (TAVR) is a challenging clinical dilemma. In our single-center study, 60 out of 172 patients who underwent permanent pacemaker implantation (PPM) after TAVR had N-LBBB (34.9%). At a median follow-up duration of 357 days (IQR, 178; 560 days), two patients (3.5%) were completely pacemaker-dependent, and four others (7%) were partially dependent. Twelve patients (24%) recovered conduction in their left bundle at a median follow-up duration of 5 weeks (IQR, 4; 14 weeks). Due to the lack of clinical predictors of pacemaker dependency, active surveillance is warranted and may be an alternative to permanent pacemaker implantation.


Assuntos
Bloqueio de Ramo/terapia , Marca-Passo Artificial , Complicações Pós-Operatórias/terapia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Bloqueio de Ramo/etiologia , Bloqueio de Ramo/mortalidade , Feminino , Seguimentos , Humanos , Masculino , Marca-Passo Artificial/estatística & dados numéricos , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/mortalidade , Implantação de Prótese/estatística & dados numéricos , Recuperação de Função Fisiológica , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/estatística & dados numéricos , Resultado do Tratamento
6.
Am J Med Genet A ; 176(7): 1622-1626, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-30160835

RESUMO

A novel autosomal-dominant in-frame deletion resulting in a nonsense mutation in the desmoplakin (DSP) gene was identified in association with biventricular arrhythmogenic cardiomyopathy across three generations of a large Caucasian family. Mutations that disrupt the function and structure of desmosomal proteins, including desmoplakin, have been extensively linked to familial arrhythmogenic right ventricular cardiomyopathy (ARVC). Analysis of data from 51 individuals demonstrated the previously undescribed variant p.Cys81Stop (c.243_251delCTTGATGCG) in DSP segregates with a pathogenic phenotype exhibiting variable penetrance and expressivity. The mutation's pathogenicity was first established due to two sudden cardiac deaths (SCDs), each with a biventricular cardiomyopathy identified on autopsy. Of the individuals who underwent genetic screening, 27 of 51 were heterozygous for the DSP mutation (29 total with two obligate carriers). Six of these were subsequently diagnosed with arrhythmogenic cardiomyopathy. An additional nine family members have a conduction disorder and/or myocardial structural changes characteristic of an evolving condition. Previous reports from both human patients and mouse studies proposed DSP mutations with a premature stop codon impart mild to no clinical symptoms. Loss of expression from the abnormal allele via the nonsense-mediated mRNA decay pathway has been implicated to explain these findings. We identified an autosomal-dominant DSP nonsense mutation in a large family that led to SCD and phenotypic expression of arrhythmogenic cardiomyopathy involving both ventricles. This evidence demonstrates the pathogenic significance of this type of desmosomal mutation and provides insight into potential clinical manifestations.


Assuntos
Displasia Arritmogênica Ventricular Direita/genética , Códon sem Sentido , Morte Súbita Cardíaca/patologia , Desmoplaquinas/genética , Genes Dominantes , Predisposição Genética para Doença , Adulto , Displasia Arritmogênica Ventricular Direita/patologia , Feminino , Humanos , Masculino , Linhagem , Prognóstico
7.
Circ Cardiovasc Qual Outcomes ; 9(5): 593-9, 2016 09.
Artigo em Inglês | MEDLINE | ID: mdl-27553597

RESUMO

Postoperative atrial fibrillation (POAF) is a frequent complication of cardiac surgery, which results in increased morbidity, mortality, length of stay, and hospital costs. We developed and followed a process map to implement a protocol to decrease POAF: (1) identify stakeholders and form a working committee, (2) formal literature and guideline review, (3) retrospective analysis of current institutional data, (4) data modeling to determine expected effects of change, (4) protocol development and implementation into the electronic medical record, and (5) ongoing review of data and protocol adjustment. Retrospective analysis demonstrated that POAF occurred in 29.8% of all cardiovascular surgery cases. Median length of stay was 2 days longer (P<0.001), and median total variable costs $2495 higher (P<0.001) in POAF patients. Modeling predicted that up to 60 cases of POAF and >$200 000 annually could be saved. A clinically based electronic medical record tool was implemented into the electronic medical record to aid preoperative clinic providers in identifying patients eligible for prophylactic amiodarone. Initial results during the 9-month period after implementation demonstrated a reduction in POAF in patients using the protocol, compared with those who qualified but did not receive amiodarone and those not evaluated (11.1% versus 38.7% and 38.8%; P=0.022); however, only 17.3% of patients used the protocol. A standardized methodological approach to quality improvement and electronic medical record integration has potential to significantly decrease the incidence of POAF, length of stay, and total variable cost in patients undergoing elective coronary artery bypass graft and valve surgeries. This framework for quality improvement interventions may be adapted to similar clinical problems beyond POAF.


Assuntos
Amiodarona/administração & dosagem , Antiarrítmicos/administração & dosagem , Fibrilação Atrial/prevenção & controle , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Protocolos Clínicos , Mineração de Dados/métodos , Registros Eletrônicos de Saúde , Pesquisa sobre Serviços de Saúde/métodos , Valvas Cardíacas/cirurgia , Melhoria de Qualidade , Indicadores de Qualidade em Assistência à Saúde , Amiodarona/efeitos adversos , Amiodarona/economia , Antiarrítmicos/efeitos adversos , Antiarrítmicos/economia , Fibrilação Atrial/economia , Fibrilação Atrial/etiologia , Fibrilação Atrial/mortalidade , Procedimentos Cirúrgicos Cardíacos/economia , Procedimentos Cirúrgicos Cardíacos/mortalidade , Ponte de Artéria Coronária/efeitos adversos , Redução de Custos , Análise Custo-Benefício , Custos de Medicamentos , Custos Hospitalares , Humanos , Incidência , Tempo de Internação , Modelos Econômicos , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Estados Unidos/epidemiologia
8.
Europace ; 15(2): 278-83, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22915789

RESUMO

AIM: The purpose of this study was to determine if Optim™, a unique copolymer of silicone and polyurethane, protects Riata ST Optim and Durata implantable cardioverter-defibrillator (ICD) leads (SJM, St Jude Medical Inc., Sylmar, CA, USA) from abrasions that cause lead failure. METHODS AND RESULTS: We searched the US Food and Drug Administration's (FDA's) Manufacturers and User Device Experience (MAUDE) database on 13 April 2012 using the simple search terms 'Riata ST Optim™ abrasion analysis' and 'Durata abrasion analysis'. Lead implant time was estimated by subtracting 3 months from the reported lead age. The MAUDE search returned 15 reports for Riata ST Optim™ and 37 reports for Durata leads, which were submitted by SJM based on its analyses of returned leads for clinical events that occurred between December 2007 and January 2012. Riata ST Optim™ leads had been implanted 29.1 ± 11.7 months. Eight of 15 leads had can abrasions and three abrasions were caused by friction with another device, most likely another lead. Four of these abrasions resulted in high-voltage failures and one death. One failure was caused by an internal insulation defect. Durata leads had been implanted 22.2 ± 10.6 months. Twelve Durata leads had can abrasions, and six leads had abrasions caused by friction with another device. Of these 18 can and other device abrasions, 13 (72%) had electrical abnormalities. Low impedances identified three internal insulation abrasions. CONCLUSIONS: Riata ST Optim™ and Durata ICD leads have failed due to insulation abrasions. Optim™ did not prevent these abrasions, which developed ≤ 4 years after implant. Studies are needed to determine the incidence of these failures and their clinical implications.


Assuntos
Arritmias Cardíacas/terapia , Desfibriladores Implantáveis/efeitos adversos , Eletrodos Implantados/efeitos adversos , Análise de Falha de Equipamento , Polietilenoglicóis/efeitos adversos , Silicones/efeitos adversos , Bases de Dados Factuais , Impedância Elétrica , Humanos , Fatores de Tempo , Estados Unidos , United States Food and Drug Administration
9.
Heart Rhythm ; 10(3): 361-5, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23128017

RESUMO

BACKGROUND: Riata and Riata ST leads (St Jude Medical, Sylmar, CA) are prone to failure. There are no independent multicenter reports regarding Riata or Riata ST lead performance. OBJECTIVE: To conduct a retrospective multicenter study of Riata and Riata ST leads that were implanted and followed at 7 centers. METHODS: The study included adults who received St Jude Medical Riata or Riata ST leads. Data for Quattro Secure leads were obtained from an earlier study. RESULTS: From 2002 to 2010, 1081 patients received a Riata (n = 774) or Riata ST (n = 307) lead. Follow-up was longer for Riata than Riata ST leads (4.2 ± 2.4 years vs 3.3 ± 1.7 years; P<.0001). During the study, 67 leads failed (6.2%), including 62 of 774 Riata (8.0%) and 5 of 307 Riata ST (1.6%) leads. Forty-seven of 67 lead failures (70.1%) were caused by electrical malfunction, and 20 lead failures (29.9%) were due to externalized conductors (ECs) that were electrically intact. Of 110 leads examined fluoroscopically, ECs were found in 26 of 81 Riata (32%) and 1 of 29 Riata ST (3.4%) leads. Of 26 Riata leads with ECs, 7 (27%) were malfunctioning. Riata leads had lower overall and malfunction free survival compared to Quattro leads (P<.0001), while Riata ST lead survival was not different (P = .422). CONCLUSIONS: The survival of Riata (but not Riata ST) leads was lower than Quattro leads; however, Riata ST leads had significantly shorter follow-up than Riata leads. ECs were common in Riata leads, and more than a quarter of Riata leads that had ECs were malfunctioning. Our observations suggest that systematic fluoroscopic examination of patients with Riata leads is appropriate.


Assuntos
Arritmias Cardíacas/terapia , Desfibriladores Implantáveis , Idoso , Desenho de Equipamento , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
10.
Am J Cardiol ; 95(4): 490-1, 2005 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-15695135

RESUMO

Hydroxymethylglutaryl coenzyme-A reductase inhibitors, or statins, have been shown to decrease mortality rates in patients who have coronary artery disease. It has been postulated that part of the mortality benefit conferred by statins is due to a decrease in ventricular arrhythmias. We assessed the effect of statin therapy on recurrent ventricular arrhythmias in 281 patients who developed coronary artery disease after implantable cardioverter-defibrillator placement. Statin therapy was associated with a significant decrease in the risk of ventricular arrhythmia that would require implantable cardioverter-defibrillator therapy.


Assuntos
Doença da Artéria Coronariana/terapia , Desfibriladores Implantáveis , Inibidores de Hidroximetilglutaril-CoA Redutases/uso terapêutico , Fibrilação Ventricular/terapia , Idoso , Feminino , Humanos , Masculino , Modelos de Riscos Proporcionais , Estudos Retrospectivos , Fatores de Risco , Prevenção Secundária
12.
Am J Cardiol ; 93(9): 1176-8, 2004 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-15110218

RESUMO

This study investigated the correlation between an elevated white blood cell (WBC) count as a marker of inflammation and the development of atrial fibrillation (AF) after cardiac surgery. WBC counts were prospectively followed in 181 consecutive patients who underwent coronary bypass or cardiac valve surgery to determine if a baseline or postoperative WBC count elevation is an independent predictor of postoperative AF.


Assuntos
Fibrilação Atrial/sangue , Fibrilação Atrial/etiologia , Ponte de Artéria Coronária , Implante de Prótese de Valva Cardíaca , Leucócitos/metabolismo , Complicações Pós-Operatórias/sangue , Complicações Pós-Operatórias/etiologia , Fatores Etários , Idoso , Fibrilação Atrial/terapia , Cardioversão Elétrica , Feminino , Seguimentos , Humanos , Incidência , Contagem de Leucócitos , Masculino , Pessoa de Meia-Idade , Ohio/epidemiologia , Complicações Pós-Operatórias/terapia , Valor Preditivo dos Testes , Estudos Prospectivos , Estatística como Assunto , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...