1.
ISA Trans ; 52(4): 525-38, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23615169

RESUMO

This paper presents a modulated hysteresis direct torque control (MHDTC) applied to an induction generator (IG) used in wind energy conversion systems (WECs) connected to the electrical grid through a back-to-back converter. The principle of this strategy consists in superposing to the torque reference a triangular signal, as in the PWM strategy, with the desired switching frequency. This new modulated reference is compared to the estimated torque by using a hysteresis controller as in the classical direct torque control (DTC). The aim of this new approach is to lead to a constant frequency and low THD in grid current with a unit power factor and a minimum voltage variation despite the wind variation. To highlight the effectiveness of the proposed method, a comparison was made with classical DTC and field oriented control method (FOC). The obtained simulation results, with a variable wind profile, show an adequate dynamic of the conversion system using the proposed method compared to the classical approaches.


Assuntos
Algoritmos , Fontes de Energia Elétrica , Eletricidade , Retroalimentação , Modelos Teóricos , Simulação por Computador , Transferência de Energia