Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
J. optom. (Internet) ; 15(1): 1-7, January-March 2022. tab, graf
Artigo em Inglês | IBECS | ID: ibc-204385

RESUMO

Purpose: To evaluate the agreement of dry, and cycloplegic autorefraction and wavefront-based refraction with subjective refraction.Method: 83 subjects aged 19–57 years were included in this cross-sectional study. Refractive status was determined using four methods including subjective refraction, wavefront-based refraction, dry and cycloplegic autorefraction. Refractive data were recorded as sphere, cylinder and spherical equivalent (SE). Power vector components were used to compare the astigmatism obtained using the different methods of refraction.Results: The more negative spherical, cylindrical and SE components were obtained using dry autorefraction, wavefront-based refraction and dry autorefraction, respectively. The less negative spherical, cylindrical and SE components were obtained using cycloplegic autorefraction, subjective refraction and cycloplegic autorefraction, respectively. Considering the spherical component, there was a statistically significant hyperopic shift (0.12 ± 0.29 D, p = 0.001) with cycloplegic autorefraction and a significant myopic shift (−0.17 ± 0.32 D, p < 0.001) with dry autorefraction compared to subjective refraction, while the difference between wavefront-based and subjective refraction was not significant statistically (p = 0.145). The calculated cylindrical component using subjective refraction showed statistically significant difference with dry auto-refraction (p < 0.001), cycloplegic auto-refraction (p = 0.041) and wavefront refraction (p < 0.001). The highest correlation with subjective refraction in sphere, cylinder and SE was observed for cycloplegic auto-refraction (rs = 0.967), dry auto-refraction (rs = 0.983) and cycloplegic auto-refraction (rs = 0.982), respectively.Conclusions: As subjective refraction is gold standard in our study, sphere in cycloplegic auto-refraction and astigmatism in dry auto-refraction showed better agreement and correlation. (AU)


Assuntos
Humanos , Adulto Jovem , Adulto , Miopia , Refração Ocular , Testes Visuais , Midriáticos , Estudos Transversais
2.
J Optom ; 15(1): 100-106, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-32896507

RESUMO

PURPOSE: To evaluate the agreement of dry, and cycloplegic autorefraction and wavefront-based refraction with subjective refraction. METHOD: 83 subjects aged 19-57 years were included in this cross-sectional study. Refractive status was determined using four methods including subjective refraction, wavefront-based refraction, dry and cycloplegic autorefraction. Refractive data were recorded as sphere, cylinder and spherical equivalent (SE). Power vector components were used to compare the astigmatism obtained using the different methods of refraction. RESULTS: The more negative spherical, cylindrical and SE components were obtained using dry autorefraction, wavefront-based refraction and dry autorefraction, respectively. The less negative spherical, cylindrical and SE components were obtained using cycloplegic autorefraction, subjective refraction and cycloplegic autorefraction, respectively. Considering the spherical component, there was a statistically significant hyperopic shift (0.12 ±â€¯0.29 D, p = 0.001) with cycloplegic autorefraction and a significant myopic shift (-0.17 ±â€¯0.32 D, p < 0.001) with dry autorefraction compared to subjective refraction, while the difference between wavefront-based and subjective refraction was not significant statistically (p = 0.145). The calculated cylindrical component using subjective refraction showed statistically significant difference with dry auto-refraction (p < 0.001), cycloplegic auto-refraction (p = 0.041) and wavefront refraction (p < 0.001). The highest correlation with subjective refraction in sphere, cylinder and SE was observed for cycloplegic auto-refraction (rs = 0.967), dry auto-refraction (rs = 0.983) and cycloplegic auto-refraction (rs = 0.982), respectively. CONCLUSIONS: As subjective refraction is gold standard in our study, sphere in cycloplegic auto-refraction and astigmatism in dry auto-refraction showed better agreement and correlation.


Assuntos
Midriáticos , Miopia , Estudos Transversais , Humanos , Refração Ocular , Testes Visuais
3.
J Ophthalmic Vis Res ; 16(2): 151-157, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34055251

RESUMO

PURPOSE: To evaluate the long-term outcomes of collagen crosslinking in early keratoconus. METHODS: Thirty eyes of twenty patients with early keratoconus were enrolled. Uncorrected visual acuity (UCVA), best spectacle corrected visual acuity (BSCVA), objective refraction, subjective refraction, corneal topography and pachymetry were assessed before and 3, 6, 12 months and 9 years after performing collagen crosslinking surgery. RESULTS: The patients' mean age was 31.2 ± 5.59 years at nine-year follow-up (range, 25-44 years). The means of preoperative UCVA and BSCVA were 0.57 ± 0.34 and 0.15 ± 0.12 logMAR, respectively, and these values remained stable at the final follow-up (P = 0.990 and P = 0.227, respectively). The mean objective spherical equivalent decreased considerably from -6.00 ± 4.05 D preoperatively to -5.22 ± 3.71 D at the final follow-up (P < 0.05). The mean subjective spherical equivalent was -4.25 ± 2.87 D preoperatively and this value was stable at the last follow-up (P = 0.92). No considerable difference was found between the post- and preoperative mean objective cylinder values (P = 0.34). The mean subjective cylinder value changed significantly from -4.05 ± 1.85 D preoperatively to -3.1 ± 1.42 D at the final follow-up (P < 0.05). The mean central corneal thickness was 496.97 ± 45.95 µm preoperatively and this value was stable at nine-year follow-up (P = 0.183). No significant difference was found between the pre- and postoperative mean maximum and mean minimum corneal curvature values (P = 0.429 and P = 0.248, respectively). There were no significant postoperative complications. CONCLUSION: Corneal crosslinking in early keratoconus seems to be a safe procedure that can effectively stabilize UCVA, BSCVA, subjective SE and CCT, while improving objective spherical equivalent.

4.
J Ophthalmol ; 2021: 8810782, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33884203

RESUMO

It is important to predict which astigmatic patients require separate refraction for near vision. This study compared cylindrical components changes by cyclopentolate 1% for the low and high amount of astigmatism. The right eyes of 1014 healthy individuals (307 males and 707 females) with cylindrical refractive power more than -0.5 diopter on autorefractometer were selected. Both male and female patients in the age range of 17-45 years were refracted before and after cycloplegia, using 1% cyclopentolate. All volunteers were classified into 2 subgroups including the lower astigmatism group (-2.25 to -0.50) and the higher astigmatic group (-2.50 to over). Alpines' method was used to compare the effect of cycloplegic drop on cylindrical power. The mean age in the lower astigmatism group (29.58; 95% CI: 29.18 to 29.99 years) was not significantly different from the higher astigmatic group (29.85; 95% CI: 29.07 to 30.62) and there were no significant differences in gender between these two groups (P=0.54). Differences between wet and dry refraction in J0 (-0.03; 95% CI:-0.06 to -0.008) and J45 (-0.03; 95% CI:-0.06 to -0.01) were significant only in the higher astigmatic group. Axis changes by the cycloplegic drop in the lower astigmatism group were 3.51 (CI: 3.22 to 3.81) and axis changes by the cycloplegic drop in the higher astigmatism group were 2.21 (CI: 1.73 to 2.49). In patients with a lower amount of astigmatism (-2.25 to -0.50), additional near subjective refraction could be done for precise determination of axis and in patients with a higher amount of astigmatism (-2.50 to over), near subjective refraction might be done for precise determination of power.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...