1.
J Mech Behav Biomed Mater ; 66: 1-11, 2017 02.
Artigo em Inglês | MEDLINE | ID: mdl-27825047

RESUMO

The main failure factors of cortical bone are aging or osteoporosis, accident and high energy trauma or physiological activities. However, the mechanism of damage evolution coupled with yield criterion is considered as one of the unclear subjects in failure analysis of cortical bone materials. Therefore, this study attempts to assess the structural response and progressive failure process of cortical bone using a brittle damaged plasticity model. For this reason, several compressive tests are performed on cortical bone specimens made of bovine femur, in order to obtain the structural response and mechanical properties of the material. Complementary finite element (FE) model of the sample and test is prepared to simulate the elastic-to-damage behavior of the cortical bone using the brittle damaged plasticity model. The FE model is validated in a comparative method using the predicted and measured structural response as load-compressive displacement through simulation and experiment. FE results indicated that the compressive damage initiated and propagated at central region where maximum equivalent plastic strain is computed, which coincided with the degradation of structural compressive stiffness followed by a vast amount of strain energy dissipation. The parameter of compressive damage rate, which is a function dependent on damage parameter and the plastic strain is examined for different rates. Results show that considering a similar rate to the initial slope of the damage parameter in the experiment would give a better sense for prediction of compressive failure.


Assuntos
Força Compressiva , Osso Cortical/fisiologia , Modelos Biológicos , Estresse Mecânico , Animais , Bovinos , Análise de Elementos Finitos
2.
Mater Sci Eng C Mater Biol Appl ; 60: 526-537, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26706560

RESUMO

The present study addressed the synthesis of a bi-layered nanostructured fluorine-doped hydroxyapatite (nFHA)/polycaprolactone (PCL) coating on Mg-2Zn-3Ce alloy via a combination of electrodeposition (ED) and dip-coating methods. The nFHA/PCL composite coating is composed of a thick (70-80 µm) and porous layer of PCL that uniformly covered the thin nFHA film (8-10 µm) with nanoneedle-like microstructure and crystallite size of around 70-90 nm. Electrochemical measurements showed that the nFHA/PCL composite coating presented a high corrosion resistance (R(p)=2.9×10(3) kΩ cm(2)) and provided sufficient protection for a Mg substrate against galvanic corrosion. The mechanical integrity of the nFHA/PCL composite coatings immersed in SBF for 10 days showed higher compressive strength (34% higher) compared with the uncoated samples, indicating that composite coatings can delay the loss of compressive strength of the Mg alloy. The nFHA/PCL coating indicted better bonding strength (6.9 MPa) compared to PCL coating (2.2 MPa). Immersion tests showed that nFHA/PCL composite-coated alloy experienced much milder corrosion attack and more nucleation sites for apatite compared with the PCL coated and uncoated samples. The bi-layered nFHA/PCL coating can be a good alternative method for the control of corrosion degradation of biodegradable Mg alloy for implant applications.


Assuntos
Ligas/química , Durapatita/química , Magnésio/química , Nanoestruturas/química , Poliésteres/química , Corrosão
3.
Int J Biomater ; 2015: 475435, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25838826

RESUMO

Polyether ether ketone (PEEK) is considered the best alternative material for titanium for spinal fusion cage implants due to its low elasticity modulus and radiolucent property. The main problem of PEEK is its bioinert properties. Coating with hydroxyapatite (HA) showed very good improvement in bioactivity of the PEEK implants. However the existing methods for deposition of HA have some disadvantages and damage the PEEK substrate. In our previous study a new method for deposition of HA on PEEK was presented. In this study cell proliferation of mesenchymal stem cell and apatite formation in simulated body fluid (SBF) tests were conducted to probe the effect of this new method in improvement of the bioactivity of PEEK. The mesenchymal stem cell proliferation result showed better cells proliferation on the treated layer in comparison with untreated PEEK. The apatite formation results showed the growth of the HA on the treated PEEK but there was not any sight of the growth of HA on the untreated PEEK even after 2 weeks. The results showed the new method of the HA deposition improved the bioactivity of the treated PEEK in comparison with the bare PEEK.

4.
Leg Med (Tokyo) ; 17(2): 71-8, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25456051

RESUMO

Age estimation was used in forensic anthropology to help in the identification of individual remains and living person. However, the estimation methods tend to be unique and applicable only to a certain population. This paper analyzed age estimation using twelve regression models carried out on X-ray images of the left hand taken from an Asian data set for subjects under the age of 19. All the nineteen bones of the left hand were measured using free image software and the statistical analysis were performed using SPSS. There are two methods to determine age in this study which are single bone method and all bones method. For single bone method, S-curve regression model was found to have the highest R-square value using second metacarpal for males, and third proximal phalanx for females. For age estimation using single bone, fifth metacarpal from males and fifth proximal phalanx from females can be used due to the lowest mean square error (MSE) value. To conclude, multiple linear regressions is the best techniques for age estimation in cases where all bones are available, but if not, S-curve regression can be used using single bone method.


Assuntos
Determinação da Idade pelo Esqueleto/métodos , Mãos/diagnóstico por imagem , Adolescente , Adulto , Povo Asiático , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Análise de Regressão
5.
Mater Sci Eng C Mater Biol Appl ; 36: 336-44, 2014 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-24433920

RESUMO

Biodegradable metals such as magnesium, iron and their alloys have been known as potential materials for temporary medical implants. However, most of the studies on biodegradable metals have been focusing on optimizing their mechanical properties and degradation behavior with no emphasis on improving their bioactivity behavior. We therefore investigated the possibility of improving iron biodegradation rate and bioactivity by incorporating various bioactive bioceramics. The iron-based bioceramic (hydroxyapatite, tricalcium phosphate and biphasic calcium phosphate) composites were prepared by mechanical mixing and sintering process. Degradation studies indicated that the addition of bioceramics lowered the corrosion potential of the composites and slightly increased their corrosion rate compared to that of pure iron. In vitro cytotoxicity results showed an increase of cellular activity when rat smooth muscle cells interacted with the degrading composites compared to pure iron. X-ray radiogram analysis showed a consistent degradation progress with that found in vivo and positive tissue response up to 70 days implantation in sheep animal model. Therefore, the iron-based bioceramic composites have the potential to be used for biodegradable bone implant applications.


Assuntos
Implantes Absorvíveis , Materiais Biocompatíveis/farmacologia , Osso e Ossos/efeitos dos fármacos , Cerâmica/farmacologia , Ferro/farmacologia , Animais , Sobrevivência Celular/efeitos dos fármacos , Corrosão , Impedância Elétrica , Teste de Materiais , Microscopia Eletrônica de Varredura , Miócitos de Músculo Liso/citologia , Miócitos de Músculo Liso/efeitos dos fármacos , Implantação de Prótese , Ratos , Ratos Sprague-Dawley , Ovinos , Espectrometria por Raios X , Difração de Raios X
6.
Genet Mol Res ; 11(4): 3882-8, 2012 Nov 12.
Artigo em Inglês | MEDLINE | ID: mdl-23212327

RESUMO

This study was carried out to evaluate the genetic effect of quantitative trait loci (QTLs) conferring drought tolerance in wheat. A population of 120 F(2) individuals from the cross between the drought-tolerant S-78-11 and drought-sensitive Tajan cultivars were analyzed for their segregation under drought stress conditions. The relative water content under drought stress conditions exhibited continuous variation, indicating the minor gene effects on the trait. Single-marker analysis (SMA) was carried out to detect the main QTL association with drought tolerance. The SMA results revealed that the simple sequence repeat markers GWM182 and GWM292 on chromosome 5D and GWM410 on chromosome 5A exhibited significant association with drought tolerance, accounting for 30, 22, and 21% of the total variation, respectively. The 3 genetic loci, especially GWM182, can be used in marker-assisted selection methods in drought tolerance breeding in wheat.


Assuntos
Segregação de Cromossomos/genética , Secas , Locos de Características Quantitativas/genética , Estresse Fisiológico/genética , Triticum/genética , Triticum/fisiologia , Água/metabolismo , Análise de Variância , Cruzamentos Genéticos , Marcadores Genéticos , Repetições de Microssatélites/genética
7.
Int J Biomater ; 2012: 641430, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22919393

RESUMO

Scaffolds have been utilized in tissue regeneration to facilitate the formation and maturation of new tissues or organs where a balance between temporary mechanical support and mass transport (degradation and cell growth) is ideally achieved. Polymers have been widely chosen as tissue scaffolding material having a good combination of biodegradability, biocompatibility, and porous structure. Metals that can degrade in physiological environment, namely, biodegradable metals, are proposed as potential materials for hard tissue scaffolding where biodegradable polymers are often considered as having poor mechanical properties. Biodegradable metal scaffolds have showed interesting mechanical property that was close to that of human bone with tailored degradation behaviour. The current promising fabrication technique for making scaffolds, such as computation-aided solid free-form method, can be easily applied to metals. With further optimization in topologically ordered porosity design exploiting material property and fabrication technique, porous biodegradable metals could be the potential materials for making hard tissue scaffolds.

8.
Int J Oral Maxillofac Surg ; 41(9): 1077-89, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22575179

RESUMO

The aim of this study was to compare two different types of surgical approaches, intrasinus and extramaxillary, for the placement of zygomatic implants to treat atrophic maxillae. A computational finite element simulation was used to analyze the strength of implant anchorage for both approaches in various occlusal loading locations. Three-dimensional models of the craniofacial structures surrounding a region of interest, soft tissue and framework were developed using computed tomography image datasets. The implants were modelled using computer-aided design software. The bone was assumed to be linear isotropic with a stiffness of 13.4 GPa, and the implants were assumed to be made of titanium with a stiffness of 110 GPa. Masseter forces of 300 N were applied at the zygomatic arch, and occlusal loads of 150 N were applied vertically onto the framework surface at different locations. The intrasinus approach demonstrated more satisfactory results and could be a viable treatment option. The extramaxillary approach could also be recommended as a reasonable treatment option, provided some improvements are made to address the cantilever effects seen with that approach.


Assuntos
Desenho Assistido por Computador , Implantação Dentária Endóssea/métodos , Planejamento de Prótese Dentária/métodos , Seio Maxilar/cirurgia , Zigoma/cirurgia , Fenômenos Biomecânicos , Simulação por Computador , Prótese Dentária Fixada por Implante , Análise do Estresse Dentário , Prótese Total , Análise de Elementos Finitos , Humanos , Imageamento Tridimensional , Modelos Anatômicos
SELEÇÃO DE REFERÊNCIAS