Phys Med Biol ; 58(18): 6279-97, 2013 Sep 21.
Artigo em Inglês | MEDLINE | ID: mdl-23965895

RESUMO

Previous research on optical computed tomography (CT) microscopy in the context of the synchrotron microbeam has shown the potential of the technique and demonstrated high quality images, but has left two questions unanswered: (i) are the images suitably quantitative for 3D dosimetry? and (ii) what is the impact on the spatial resolution of the system of the limited depth-of-field of the microscope optics? Cuvette and imaging studies are reported here that address these issues. Two sets of cuvettes containing the radiochromic plastic PRESAGE® were irradiated at the ID17 biomedical beamline of the European Synchrotron Radiation facility over the ranges 0-20 and 0-35 Gy and a third set of cuvettes was irradiated over the range 0-20 Gy using a standard medical linac. In parallel, three cylindrical PRESAGE® samples of diameter 9.7 mm were irradiated with test patterns that allowed the quantitative capabilities of the optical CT microscope to be verified, and independent measurements of the imaging modulation transfer function (MTF) to be made via two different methods. Both spectrophotometric analysis and imaging gave a linear dose response, with gradients ranging from 0.036-0.041 cm(-1) Gy(-1) in the three sets of cuvettes and 0.037 (optical CT units) Gy(-1) for the imaging. High-quality, quantitative imaging results were obtained throughout the 3D volume, as illustrated by depth-dose profiles. These profiles are shown to be monoexponential, and the linear attention coefficient of PRESAGE® for the synchrotron-generated x-ray beam is measured to be (0.185 ± 0.02) cm(-1) in excellent agreement with expectations. Low-level (<5%) residual image artefacts are discussed in detail. It was possible to resolve easily slit patterns of width 37 µm (which are smaller than many of the microbeams used on ID-17), but some uncertainty remains as to whether the low values of MTF for the higher spatial frequencies are scanner related or a result of genuine (but non-ideal) dose distributions. We conclude that microscopy images from our scanner do indeed have intensities that are proportional to spectrophotometric optical density and can thus be used as the basis for accurate dosimetry. However, further investigations are necessary before the microscopy images can be used to make the quantitative measures of peak-to-valley ratios for small-diameter microbeams. We suggest various strategies for moving forward and are optimistic about the future potential of this system.


Assuntos
Microscopia/métodos , Radiometria/métodos , Síncrotrons , Tomografia Óptica/métodos , Tomografia Computadorizada por Raios X/métodos , Relação Dose-Resposta à Radiação , Desenho de Equipamento , Humanos , Imageamento Tridimensional , Imagens de Fantasmas , Plásticos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Reprodutibilidade dos Testes , Espectrofotometria/métodos , Raios X
2.
Appl Radiat Isot ; 70(7): 1158-61, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22309632

RESUMO

This study aims to establish the sensitive, ∼120 µm high spatial resolution, high dynamic range Ge-doped optical fibres as thermoluminescence (TL) dosimeters for brachytherapy dose distribution. This requires investigation to accommodate sensitivity of detection, both for the possibility of short range dose deposition from beta components as well as gamma/x-mediated dose. In-air measurements are made at distances close to radionuclide sources, evaluating the fall off in dose along the transverse axis of 133Ba and 60Co radioactive sources, at distances from 2 mm up to 20 mm from their midpoints. Measurements have been compared with Monte Carlo code DOSRZnrc simulations for photon-mediated dose only, agreement being obtained to within 3% and 1% for the 133Ba and 60Co sources, respectively. As such, in both cases it is determined that as intended, beta dose has been filtered out by source encapsulation.


Assuntos
Braquiterapia , Germânio/química , Fibras Ópticas , Dosagem Radioterapêutica , Dosimetria Termoluminescente/instrumentação , Humanos
3.
Appl Radiat Isot ; 70(7): 1436-41, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22154388

RESUMO

We investigate the ability of high spatial resolution (∼120 µm) Ge-doped SiO2 TL dosimeters to measure photoelectron dose enhancement resulting from the use of a moderate to high-Z target (an iodinated contrast media) irradiated by 90 kVp X-rays. We imagine its application in a novel radiation synovectomy technique, modelled by a phantom containing a reservoir of I2 molecules at the interface of which the doped silica dosimeters are located. Measurements outside of the iodine photoelectron range are provided for using a stepped-design that allows insertion of the fibres within the phantom. Monte Carlo simulation (MCNPX) is used for verification. At the phantom medium I2-interface additional photoelectron generation is observed, ∼60% above that in the absence of the I2, simulations providing agreement to within 3%. Percentage depth doses measured away from the iodine contrast medium reservoir are bounded by published PDDs at 80 kVp and 100 kVp.

4.
Phys Med Biol ; 56(14): 4177-99, 2011 Jul 21.
Artigo em Inglês | MEDLINE | ID: mdl-21701054

RESUMO

Optical computed tomography (CT), in conjunction with radiochromic gels and plastics, shows great potential for radiation therapy dose verification in 3D. However, an effective quality assurance (QA) regime for the various scanners currently available still remains to be developed. We show how the favourable properties of the PRESAGE® radiochromic polymer may be exploited to create highly sophisticated QA phantoms. Five 60 mm diameter cylindrical PRESAGE® samples were irradiated using the x-ray microbeam radiation therapy facility on the ID-17 biomedical beamline at the European Synchrotron Radiation Facility. Samples were then imaged on the University of Surrey parallel-beam optical CT scanner. The sample irradiations were designed to allow a variety of tests to be performed, including assessments of linearity, modulation transfer function (three independent measurements), geometric distortion and the effect of treatment fractionation. It is clear that, although the synchrotron method produces extremely high-quality test objects, it is not practical on a routine basis, because of its reliance on a highly specialized radiation source. Hence, we investigated a second possibility: three PRESAGE® samples were illuminated with ultraviolet light of wavelength 365 nm, using cheap masks created by laser-printing patterns onto overhead projector acetate sheets. There was good correlation between optical densities measured by the CT scanner and the expected UV 'dose' delivered. The results are encouraging and a proposal is made for a scanner test regime based on calibrated and well-characterized PRESAGE® samples.


Assuntos
Fenômenos Ópticos , Tomografia Computadorizada por Raios X/instrumentação , Tomografia Computadorizada por Raios X/normas , Modelos Lineares , Controle de Qualidade , Doses de Radiação , Radioterapia , Síncrotrons , Raios Ultravioleta