Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Biosens Bioelectron ; 109: 123-131, 2018 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-29547773

RESUMO

A new portable electrochemical sensor based on 4-aminobenzoic acid-modified herringbone carbon nanotubes (hCNTs-4ABA/Au-IDA) has been developed for the simultaneous determination of ascorbic acid (AA) and uric acid (UA) in physiological fluids. AA and UA were quantified by chronoamperometry at 0.1 and 0.32 V, respectively, in phosphate buffer solution (PBS 0.25 M, pH 7.0). Significant results were obtained for the separate quantification of AA and UA, with a limit of detection (LOD) of 0.65 µM for both analytes, and sensitivities of (9.0 ±â€¯0.4) A g-1 mM-1 and (8.8 ±â€¯0.3) A g-1 mM-1 for AA and UA, respectively. Repeatability was studied at 50 µM for AA and UA, providing relative standard deviations (RSD) lower than 9%. Additions of glucose, dopamine and epinephrine did not interfere with the AA and UA determination. Furthermore, UA did not interfere with AA determination at 0.1 V, although AA additions increased the current recorded at 0.32 V. The method has been successfully applied to human urine, perspiration and serum samples, without significant matrix effects, which allows for the use of an external calibration and the analysis of all the matrices investigated.


Assuntos
Ácido Ascórbico/isolamento & purificação , Técnicas Biossensoriais , Ácido Úrico/isolamento & purificação , Ácido 4-Aminobenzoico/química , Ácido Ascórbico/química , Dopamina , Eletroquímica , Humanos , Limite de Detecção , Nanotubos de Carbono/química , Polímeros , Ácido Úrico/química
2.
Biosens Bioelectron ; 91: 885-891, 2017 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-28167366

RESUMO

Here we present two types of all-printable, highly stretchable, and inexpensive devices based on platinum (Pt)-decorated graphite for glucose determination in physiological fluids. Said devices are: a non-enzymatic sensor and an enzymatic biosensor, the latter showing promising results. Glucose has been quantified by measuring hydrogen peroxide (H2O2) reduction by chronoamperometry at -0.35V (vs pseudo-Ag/AgCl) using glucose oxidase immobilized on Pt-decorated graphite. The sensor performs well for the quantification of glucose in phosphate buffer solution (0.25M PBS, pH 7.0), with a linear range between 0 mM and 0.9mM, high sensitivity and selectivity, and a low limit of detection (LOD). Thus, it provides an alternative non-invasive and on-body quantification of glucose levels in human perspiration. This biosensor has been successfully applied on real human perspiration samples and results also show a significant correlation between glucose concentration in perspiration and glucose concentration in blood measured by a commercial glucose meter.


Assuntos
Técnicas Biossensoriais/instrumentação , Técnicas Eletroquímicas/instrumentação , Glucose/análise , Suor/química , Adulto , Elasticidade , Eletrodos , Enzimas Imobilizadas/química , Desenho de Equipamento , Feminino , Glucose Oxidase/química , Grafite/química , Humanos , Peróxido de Hidrogênio/análise , Limite de Detecção , Masculino , Platina/química , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...