Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Materials (Basel) ; 15(16)2022 Aug 17.
Artigo em Inglês | MEDLINE | ID: mdl-36013785

RESUMO

Buildings and other infrastructure should be designed to withstand impact loads in terrorist attacks or industrial catastrophes. Fibrous concrete is utilized in a variety of ways in the construction of structures to resist impact loads. Preplaced aggregate fibrous concrete (PAFC) has a different production method than traditional fibrous concrete. Although PAFC offers several benefits over standard fibers in the construction of protective structures, there are relatively few investigations on the behavior of PAFC when exposed to impact loads. This research investigated the impact response of PFAC with the combined action of steel fibers and glass fiber mesh (GFM). Twenty-two mixtures were prepared and divided into two groups in which there were fibrous and non-fibrous specimens. The specimens from the first group comprised various diameters (ratio of reinforcement surface to total sample surface) of GFM and were provided in two and four layers. The second group of specimens is the same as the first group, including a 3% dosage of steel fibers. All specimens were subjected to a drop-weight impact test and the key parameters examined were cracking and failure impact energies, ductility index and failure pattern. The results indicated that the incorporation of GFM increased the impact performance and impact ductility, where the retained impact energies and the ductility index increased by increasing the ratio of reinforcement surface (diameter) of GFM and its number of layers. However, the positive influence of SF in enhancing the impact performance was way higher than that of GFM. The use of 3% hooked-end SF improved the failure impact energy by more than 3000%, while the maximum improvement gained by using four layers of 150 mm diameter (full reinforcement surface) GFM was approximately 400%.

2.
Materials (Basel) ; 15(15)2022 Jul 30.
Artigo em Inglês | MEDLINE | ID: mdl-35955217

RESUMO

With the aim of investigating the response of concrete to the dual effect of accidental fire high temperatures and possible induced impacts due to falling fragmented or burst parts or objects, an experimental work is conducted in this study to explore the influence of exposure to temperatures of 200, 400 and 600 °C on the responses of concrete specimens subjected to impact loads. Cylindrical specimens are tested using the recommended repeated impact procedure of the ACI 544-2R test. Three concrete mixtures with concrete nominal design strengths of 20, 40 and 80 MPa are introduced to represent different levels of concrete strength. From each concrete mixture, 24 cylinders and 12 cubes are prepared to evaluate the residual impact resistance and compressive strength. Six cylindrical specimens and three cubes from each concrete mixture are heated to each of the three levels of high temperatures, while the other six cylinders and three cubes are tested without heating as reference specimens. The test results show that the behavior of impact resistance is completely different from that of compressive strength after exposure to high temperatures; the cylindrical specimens lose more than 80% of the cracking and failure impact resistance after exposure to 200 °C, while impact resistance almost vanishes after exposure to 400 and 600 °C. Concrete compressive strength is found to be effective on the unheated impact specimens, where the higher-strength cylinders retain significantly higher impact numbers. This effect noticeably decreases after exposure to 200 and 400 °C, and vanishes after exposure to 600 °C.

3.
Materials (Basel) ; 15(15)2022 Jul 25.
Artigo em Inglês | MEDLINE | ID: mdl-35897586

RESUMO

The proper disposal of used rubber tires has emerged as a primary concern for the environment all over the globe. Millions of tires are thrown away, buried and discarded every year, posing a major environmental concern owing to their slow decomposition. As a result, it is advantageous to use recycled waste rubber aggregates as an additional building resource. Recycling crushed rubber would lead to a long-term solution to the problem of decreasing natural aggregate resources while conserving the environment. This study examines the impact strength variability and reliability of preplaced aggregate concrete containing crumped rubber and fibres. Ten different mixtures were prepared by replacing natural aggregate with crumped rubber (5, 10, 15 and 20%). The crumped rubber was pretreated by the water with sodium hydroxide dilution for 30 min before usage. Hooked-end steel fibres were used at a dosage of 1.5%. The compressive strength, impact strength, impact ductility index and failure pattern were examined and discussed. In addition, a statistical method called Weibull distribution is used to analyze the scattered experimental results. The results showed that when the crumb rubber content was raised, the retained first cracking and failure impact numbers increased. As a result of substituting crumb rubber for 20% of the coarse aggregate in plain and fibrous mixes, the percentage development in first crack and failure was between 33% and 76% and 75% to 129%, respectively.

4.
Materials (Basel) ; 15(11)2022 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-35683244

RESUMO

The ACI 544-2R introduced a qualitative test to compare the impact resistance of fibrous concretes under repeated falling-mass impact loads, which is considered to be a low-cost, quick solution for material-scale impact tests owing to the simplified apparatus, test setup and procedure, where none of the usual sophisticated sensors and data acquisition systems are required. However, previous studies showed that the test results are highly scattered with noticeably unacceptable variations, which encouraged researchers to try to use statistical tools to analyze the scattering of results and suggest modifications to reduce this unfavorable disadvantage. The current article introduces a state-of-the-art literature review on the previous and recent research on repeated impact testing of different types of fibrous concrete using the ACI 544-2R test, while focusing on the scattering of results and highlighting the adopted statistical distributions to analyze this scattering. The influence of different mixture parameters on the variation of the cracking and failure impact results is also investigated based on data from the literature. Finally, the article highlights and discusses the literature suggestions to modify the test specimen, apparatus and procedure to reduce the scattering of results in the ACI 544-2R repeated impact test. The conducted analyses showed that material parameters such as binder, aggregate and water contents in addition to the maximum size of aggregate have no effect on the variation of test results, while increasing the fiber content was found to have some positive influence on decreasing this variation. The survey conducted in this study also showed that the test can be modified to lower the unfavorable variations of impact and failure results.

5.
Materials (Basel) ; 15(7)2022 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-35407930

RESUMO

The brittleness of plain concrete represents a significant issue to the integrity of concrete structures when subjected to impact loading. Recent rapid industrialization has attracted researchers to find a solution for concrete brittleness and enhance its ductility. In light of this, the prepacked aggregate fibrous concrete (PAFC) with single and double precoated coarse aggregates using asphalt is proposed and examined. Nine different mixtures were designed using polypropylene and steel fibre of 3% dosage with single and double asphalt-coated aggregates. Specimens were prepared with natural aggregate and 100% C-graded asphalt-coated aggregate to evaluate their impact strength. The ACI Committee 544 drop-weight impact standard was followed in the testing of all specimens. Results indicated that using asphalt-coated aggregate can improve the impact energies of concrete. The impact energy at cracking and failure of the single asphalt-coated aggregate specimen was 1.55 and 2.11 times higher, while the double-coated aggregate specimens exhibited 1.73 and 2.56 times greater than the natural aggregate specimen, respectively. The contribution of fibres in enhancing the impact resistance is remarkable compared to the single- and double-coated aggregates used in PAFC.

6.
Materials (Basel) ; 15(1)2022 Jan 04.
Artigo em Inglês | MEDLINE | ID: mdl-35009486

RESUMO

It appears that the awareness and intentions to use recycled concrete aggregate (RCA) in concrete are expanding over the globe. The production of self-compacting concrete (SCC) using RCA is an emerging field in the construction sector. However, the highly porous and absorptive nature of adhered mortar on RCA's surface leads to reduced concrete strength, which can be removed with the application of various techniques, such as acid treatment. This study investigated the effect of the partial replacement of silica fume by cement and natural aggregate (NA) by RCA with and without steel fibre. The used RCA was treated with magnesium sulphate solution. It was immersed in solutions with different concentrations of 10%, 15% and 20% and for different periods of 5, 10 and 15 days. Sixteen mixes were prepared, which were divided into six groups with or without 1% of steel fibre content. The fresh properties, compressive strength, split tensile strength and impact resistance were examined. The results revealed that the strengths of the mixes with 20% RCA were marginally better than those of the control mixes. The compressive strength and split tensile strength were reduced by 34% and 35% at 60% RCA content, respectively, as compared to the control mixes.

7.
Materials (Basel) ; 14(2)2021 Jan 12.
Artigo em Inglês | MEDLINE | ID: mdl-33445781

RESUMO

This research aims to examine the fracture toughness of hybrid fibrous geopolymer composites under mode II. For this purpose, eight geopolymer mixtures were cast and tested to evaluate the influence of steel and synthetic fiber hybridization on mode II fracture response. The first mixture was plain and was kept as a reference, while steel, polypropylene and glass fibers were used in the rest seven mixtures. The first three of which were mono-reinforced with one of the three fibers, while the rest of the four were hybrids reinforced with combinations of steel and synthetic fibers. The Brazilian center notched disc and the double notched cube test configurations were used to evaluate the mode II fracture toughness of the eight mixtures. The results of the tests showed that steel fibers played the vital role in enhancing the fracture toughness, where the mixtures S1.6 and S1.3G0.3 showed the best performance. The results also showed that increasing the notch depth decreased the fracture toughness with an approximate linear decrement fashion. It was found that the use of double-notched cubes resulted in much higher fracture toughness than the Brazilian notched discs, where the ratio of normalized fracture toughness of the disc specimens to cube specimens was approximately 0.37 to 0.47. This is attributed to the concentration of stresses along one defined path in the disc specimens compared to the multi-path stresses in the cube specimens. In addition, the accompanied tensile stresses in the disc specimens may lead to a mode I fracture before the designed mode II fracture.

8.
Heliyon ; 6(1): e03198, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31956719

RESUMO

Steel fiber has become a proven material that can significantly alter the behavior of different types of concrete mixtures from brittle to more ductile ones. Rich literature is currently available on the mechanical properties of steel fiber-reinforced self-compacting concrete. However, the investigation of the impact resistance of this material to drop weight is still required to enrich the knowledge about its behavior under different loading conditions. An experimental work was conducted in this research to evaluate the performance of steel fiber-reinforced self-compacting concrete under repeated impact loading using the repeated blows test recommended by ACI 544-2R. The tests investigated the effect of drop weight and drop height in addition to fiber content. Straight micro-steel fibers were incorporated in three volumetric contents of 0.5, 0.75 and 1.0% and were compared with a similar plain mixture. The test equipment was adjusted to conduct repeated impact loading from different drop-heights and using different drop-weights. The adopted drop-heights were 450, 575 and 700 mm, while the adopted drop-weights were 4.5, 6.0 and 7.5 kg. The combination of the adopted drop-heights and weights composes four loading cases in addition to the standard loading case with a drop-weight and drop-height of 4.5 kg and 450 mm. The inclusion of micro steel fiber was found to significantly increase the impact resistance of self-compacting concrete with percentage developments ranging from 150 to 860% compared to plain samples. The specimens tested under 4.5 kg and 450 mm drop weight and height exhibited the highest percentage improvement in impact resistance among the five loading cases. The results also showed that the impact ductility of fibrous specimens was up to 24% higher than that of plain specimens.